High-Compton-frequency, parity-independent, mesoscopic Schrödinger-cat-state atom interferometer with Heisenberg-limited sensitivity

Resham Sarkar, Renpeng Fang, and Selim M. Shahriar
Phys. Rev. A 98, 013636 – Published 31 July 2018

Abstract

We present a protocol for an atomic interferometer that reaches the Heisenberg limit (HL), within a factor of 2, via collective state detection and critical tuning of one-axis twist spin squeezing. It generates a Schrödinger cat state, as a superposition of two extremal collective states. When this Schrödinger-cat-state interferometer is used as a gyroscope, the interference occurs at an ultrahigh Compton frequency, corresponding to a mesoscopic single object with a mass of Nm, where N is the number of particles in the ensemble, and m is the mass of each particle. For Rb87 atoms, with N=106, for example, the interference would occur at a Compton frequency of 2×1031 Hz. Under this scheme, the signal is found to depend critically on the parity of N. We present two variants of the protocol. Under protocol A, the fringes are narrowed by a factor of N for one parity, while for the other parity the signal is zero. Under protocol B, the fringes are narrowed by a factor of N for one parity, and by a factor of N for the other parity. Both protocols can be modified in a manner that reverses the behavior of the signals for the two parities. Over repeated measurements under which the probability of being even or odd is equal, the averaged sensitivity is smaller than the HL by a factor of 2 for both versions of the protocol. We describe an experimental scheme for realizing such an atomic interferometer, and discuss potential limitations due to experimental constraints imposed by the current state of the art, for both collective state detection and one-axis-twist squeezing. We show that when the Schrödinger-cat-state interferometer is configured as an accelerometer, the effective two-photon wave vector is enhanced by a factor of N, leading to the same degree of enhancement in sensitivity. We also show that such a mesoscopic single object can be used to increase the effective base frequency of an atomic clock by a factor of N, with a sensitivity that is equivalent to the HL, within a factor of 2.

  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Received 22 June 2018

DOI:https://doi.org/10.1103/PhysRevA.98.013636

©2018 American Physical Society

Physics Subject Headings (PhySH)

Atomic, Molecular & OpticalQuantum Information, Science & Technology

Authors & Affiliations

Resham Sarkar1, Renpeng Fang1, and Selim M. Shahriar1,2,*

  • 1Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, USA
  • 2Department of EECS, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, USA

  • *shahriar@northwestern.edu

Article Text (Subscription Required)

Click to Expand

References (Subscription Required)

Click to Expand
Issue

Vol. 98, Iss. 1 — July 2018

Reuse & Permissions
Access Options
CHORUS

Article Available via CHORUS

Download Accepted Manuscript
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review A

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×