Abstract

Objective. To explore the effects of transcranial direct current stimulation (tDCS) on the motor recovery of stroke patients and the effect differences between the upper limb and lower limb. Methods. Randomized control trials published until January 2019 were searched from PubMed, Embase, ScienceDirect, and Cochrane Library databases. The standardized mean difference (SMD) with 95% confidence interval (CI) was estimated separately for upper and lower limb motor outcomes to understand the mean effect size. Results. Twenty-nine studies with 664 subjects were included in this meta-analysis. The overall analyses of tDCS demonstrated significant effect size both for the upper limb (, ) and the lower limb (, ). Compared with acute and subacute stroke patients, chronic stroke patients obtained significant effects after tDCS (, ) in upper limb function. Furthermore, both anode and cathode stimulations produced significant effect size for stroke patients after ≤10 sessions of tDCS (anode: , ; cathode: , ) with >0.029 mA/cm2 of density (anode: , ; cathode: , ). But for lower limb function, more prominent effects were found in subacute stroke patients (, ) with bilateral tDCS (, ). Conclusion. tDCS is effective for the recovery of stroke patients with motor dysfunction. In addition, upper limb and lower limb functions obtain distinct effects from different therapeutic parameters of tDCS at different stages, respectively.

1. Introduction

Stroke, a kind of cerebral blood circulation disorder disease which can cause neurological deficits, is one of the leading causes of disability in the world’s elderly population [1]. Studies have predicted that stroke will occupy an undeniable proportion of the global burden of disease by 2020 reaching to 6.2% [2]. It is, therefore, very necessary to find a useful way to recover the motor function of paretic limb after stroke. The interhemispheric competition mechanism shows a reciprocal inhibition of the neural activity between bilateral hemispheres in a healthy brain, which is realized by the transcallosal fibers [3]. The balance is broken after a unilateral stroke resulting in excessive excitation of the unaffected hemisphere and increased inhibition to the affected hemisphere [4]. Therefore, rebalance of the brain is the key for the recovery of function [5]. In addition to competition mechanism, a recent, bimodal balance-recovery model has been proposed which holds that the competition and vicariation model combined to regulate the balance between the hemispheres [6].

Conventional therapies including constraint-induced movement therapy [7, 8], robotic training [9], and occupational therapy [10] play an important role for the recovery of motor function after stroke, but these physiotherapies have some limitations which make researchers intend to seek more effective ways to boost limb function recovery by reinforcing cortical plasticity [6]. Noninvasive brain stimulation has been prevalent in recent years. These mainly include tDCS and repetitive transcranial magnetic stimulation (rTMS). Compared with rTMS and traditional treatment methods, tDCS has the characteristics of feasibility, cost-effectiveness, convenience, etc. Also, a review [11] and two meta-analyses [12, 13] have indicated that tDCS is safe and tolerable. Up to now, a large number of studies on tDCS applied to neurological diseases have been published, such as stroke [14], depression [15, 16], and Parkinson’s disease [17]. Noninvasive tDCS regulates motor cortex excitability mainly by influencing the polarity of the membrane [18]. Anode increases excitability and cathode reduces excitability [19]. Therefore, when the anode is applied to the ipsilesional cerebral hemisphere or the cathode to the contralesional hemisphere, the balance between the interhemispheres could be restored. Someone had described that cortical electrical stimulation combined with a motor training was better in improving motor function of the affected hand than a motor training alone [20]. And early intervention reduces the likelihood of functional disability [21].

Several reviews and meta-analyses had previously investigated the recovery of tDCS to upper limb motor function in survivors of stroke [20, 2225]. However, opinions were varied. The majority of researches showed a beneficial effect to a paretic upper limb in stroke patients by tDCS [20, 24, 25], but in another two studies, one showed a tiny, nonsignificant effect on the impairment of upper extremity [22], and the other indicated that tDCS had no effect on the recovery of the arm function [23]. It was precisely because of the disagreements that further exploration was required. Furthermore, few articles discuss the specific parameters of tDCS to the upper limb. We would explore these in this article. Before our study, few reviews had researched the effect of tDCS on the lower limb function. Only one meta-analysis denoted that tDCS improved the lower limb muscle strength [26]. It is valuable to do something in lower limb function after stroke.

To sum up, the main purpose of this meta-analysis was to obtain different therapeutic effects of tDCS on upper and lower limb recovery of stroke patients with motor dysfunction. First, we need to confirm whether tDCS is beneficial to upper and lower limb function after first unilateral stroke and then to further explore the optimal parameters of tDCS and which stage of stroke is more effective by tDCS.

2. Methods

2.1. Search Strategy

We have searched clinical trials published before January 12, 2019, from PubMed, Embase, ScienceDirect, and Cochrane Library databases. The keywords were “tDCS” or “transcranial direct current stimulation,” “stroke,” or “cerebrovascular accident”.

2.2. Inclusion and Exclusion Criteria

In order to guarantee the quality of articles, we unified the inclusion criteria. The details were as follows: (1) all patients were adults (≥18 years) and were diagnosed with a first stroke; (2) the articles were focused on the effect of tDCS on the recovery of motor function in stroke patients; (3) the stimulation sites were located in the primary motor cortex (M1); (4) all experiments were randomized control trials including crossover and parallel design; (5) ≥5 patients were enrolled, and all control groups were sham tDCS; (6) all included articles were peer-reviewed and published in English; and (7) the results were measured with scales. The exclusion criteria were as follows: (1) patients who had other diseases that could cause motor dysfunction; (2) articles that had been published but did not provide raw data, such as reviews, meta-analysis, or case reports; (3) animal experiments; and (4) results that were not expressed as or , but as median or interquartile range.

2.3. Literature Quality Assessment

Two reviewers independently completed the methodological quality assessment of the included articles by using a modified checklist from Moher et al. [27]. If the opinions were inconsistent, a third reviewer reevaluated the articles and discussed with the two reviewers to reach an agreement. The specific criteria were as follows: (1) randomization; (2) blind procedure; (3) baseline data description; (4) control study; (5) dropout number; and (6) side effects. Randomization was recorded as “1” if the random distribution method was used in the study and “0” if not. For the blinded method, “0” represented the nonblinded procedure, and “1” and “2” represented the single and double-blind procedures, respectively. If baseline data was given, it was denoted as “1” and was denoted as “0” if not. The control design was recorded as “1” if the experiment was designed with a healthy control group, “2” with a patient control group, and “3” with both control groups. Dropout number and side effects were recorded as a number of events.

2.4. Data Extraction and Analyses

Two experienced reviewers completed the data extraction independently. The basic information included sample size, mean age, time of poststroke, study design, stimulation parameters (current density, session), stimulation site, and outcome measurements. If no change data was given in the article, the data of prestimulation and poststimulation was extracted. If only the graph was given in the article, we used the software of GetData Graph Digitizer 2.25 (http://getdata-graph-digitizer.com/) to get useful data.

An immediate effect was performed to investigate the curative effect on motor function recovery of stroke patients between real and sham tDCS. The following subgroup analyses were performed: polarity (anode vs. cathode vs. bilateral), stroke stage (acute vs. subacute vs. chronic), current density (≤0.029 mA/cm2 vs. >0.029 mA/cm2), and treatment sessions (≤10 sessions vs. >10 sessions).

Review Manager Software version 5.3 (Cochrane Collaboration, Oxford, England) was used to analyze data in this meta-analysis. The effect of tDCS was expressed as the standardized mean difference (SMD) with 95% confidence interval (CI). The heterogeneity was estimated by using Cochran’s test and test. If the value was smaller than 50%, the fixed effects model was used; otherwise, a random effects model was used. View publication bias with a funnel plot. A statistically significant value was set to 0.05.

3. Result

3.1. Literature Selection

By searching the four databases mentioned above, a total of 2,197 articles were found. Finally, only 29 studies were included in this meta-analysis based on the inclusion and exclusion criteria. The specific flow chart is shown in Figure 1.

3.2. Literature Characteristics

In the final included articles, stroke patients enrolled in two articles were in the acute phase [10, 28], 11 in the subacute phase, and 13 in the chronic phase. The remaining three papers recruited both subacute and chronic stroke patients. With regard to the experimental method, all the included studies were randomized control trials. As for the treatment parameters of tDCS, the current density ranged from 0.014 mA/cm2 to 0.28 mA/cm2. For sessions, at least one session up to 40 sessions of tDCS were performed. The stimulation sites of all included articles were M1. All included subjects suffered their first ever unilateral stroke. The main characteristics and the quality assessment of the included studies are shown in Tables 1 and 2, respectively.

3.3. Adverse Effect

A total of 11 articles showed side effects; three studies reported a tingling sensation under the electrodes [10, 28, 29]. Fleming et al. reported one patient quit due to a headache after the first intervention [30]. Triccas et al. mentioned one patient dropped out due to a skin reaction after receiving treatment and other side effects could be accepted by the remaining patients [31]. In the experiment of Kim et al., two subjects discontinued tDCS, one was due to headache and the other was because of dizziness [32]. Pain occurred in both groups in the study of Fusco et al. [33]. Light flashes, fatigue or warmth, etc. occurred in another four studies, but all subjects could endure and complete treatments. The remaining 18 articles either had not side effects or were not mentioned in the articles.

4. Results of Meta-Analysis

4.1. Overall Effect of tDCS

The pooled results showed that tDCS was effective to upper limb (, 95% CI: 0.09-0.42, , ) and lower limb (, 95% CI: 0.17-0.77, , ) function in stroke patients (Figure 2). The corresponding funnel plots above were approximately symmetrical and closed to the center line which indicated very small publication bias (Figure 3).

4.2. Upper Limb: Immediate Effect of tDCS to Different Stages of Stroke Patients

According to the duration of stroke, the included studies were divided into the acute, subacute, and chronic groups. The comparison of the pooled results showed that the tDCS only revealed a significant effect (, 95% CI: 0.02-0.47, , ) in the patients of the chronic group (Figure 4).

4.3. Upper Limb: The Parameters of tDCS

The subgroup analysis of polarity showed that both the anode tDCS (, 95% CI: 0.06-0.43, , ) and cathode tDCS (, 95% CI: 0.15-0.67, , ) were significantly effective on upper limb function recovery (Figure 5). Therefore, further subgroup analyses of sessions and current density were conducted based on the anode and cathode tDCS studies separately.

The subgroup analysis of sessions revealed that the significant mean effect sizes were observed when ≤10 sessions of tDCS were given in both the anode tDCS (, 95% CI: 0.16-0.65, , ) (Figure 6(a)) and cathode tDCS groups (, 95% CI: 0.43-1.16, , ) (Figure 6(b)).

For the stimulation current density, we observed that the mean effect sizes were more significant when the current density of tDCS was more than 0.029 mA/cm2 on the basis of ≤10 sessions also in both the anode tDCS (, 95% CI: 0.17-0.74, , ) (Figure 7(a)) and cathode tDCS groups (, 95% CI: 0.40-1.18, , ) (Figure 7(b)).

4.4. Lower Limb: Immediate Effect of tDCS to Stroke Patients

The data of six studies were summarized and found that tDCS had a better significant effect on the recovery of lower limb function in sub-acute stroke patients (, 95% CI: 0.22-0.90, , ) (Figure 8), especially bihemispheric tDCS stimulation (, 95% CI: 0.14-1.03, , ) (Figure 9).

5. Discussion

Although many articles have proved that tDCS was beneficial to motor function recovery after stroke, few have analyzed the specific parameters. In this meta-analysis, we observed the positive effects of tDCS on the recovery of limb motor function after stroke. This was consistent with Edwardson et al. [34], but some differences existed between upper and lower limbs in tDCS parameters.

In terms of tDCS stimulation mode, we found that both the anode and cathode were beneficial to the recovery of upper limb motor function after stroke, which is in accordance with a previous review by Lüdemann-Podubecká et al. [25]. Two other papers had a similar conclusion that tDCS was beneficial to upper limb function in stroke patients [20, 24]. Although another meta-analysis reported that the effect of anode tDCS on stroke patients with motor dysfunction was not significant, it was positive for the motor recovery [19]. Furthermore, the increased corticomotor excitability was also observed in both stroke and healthy subjects in this study. Therefore, tDCS has a positive effect on the motor recovery of stroke patients, and its therapeutic effect may be related to the modulation of the neural activity between interhemispheres. The motor cortical excitability was imbalanced after stroke, due to the overactive unaffected hemisphere which increased the inhibition to the affected hemisphere [35]. The cathode or anode tDCS could promote the recovery of motor function by inhibiting the hyperactivity of the unaffected motor cortex or activating the injured motor cortex [36].

In further subgroup analysis on stroke stages, we found that the therapeutic effect of tDCS was better in chronic stroke patients than acute and subacute patients with upper limb disorder. This is consistent with the results in Jodie Marquez et al. [37]. Lüdemann-Podubecká et al. also held the same view that tDCS existed a positive effect in chronic stroke with upper limb dysfunction [25]. The excitability of the corticospinal is different in the subacute and chronic phases during stroke rehabilitation. Several functional magnetic resonance imaging studies of the brain have shown that the unaffected hemisphere is overactive after stroke. The hyperactivity leads to a less effect on the recovery of affected hand function in the subacute phase, but a better effect on the chronic phase [20, 38, 39]. However, the specific mechanism in this phenomenon was not very clear. It may be due to that after three to six months, neural recovery reached peak and remained stable [40, 41]. In addition, a study reported that short latency afferent inhibition (a marker of central cholinergic activity) was suppressed at the acute phase, but increased at six months, which was associated with better recovery of motor function [42].

One previous meta-analysis demonstrated that a positive dose-response relationship existed between current density and recovery of motor function after stroke [43]. This is in line with the results of our meta-analysis. Nitsche et al. found that the membrane depolarization or hyperpolarization induced by tDCS was determined by the current density. The larger the current density, the better the effect of tDCS [44]. Another systematic review and meta-analysis indicated that the efficacy of anode tDCS depended on the current density and duration of stimulation [19]. They observed that the effect of current density above 0.029 mA/cm2 was more significant than that below 0.029 mA/cm2. However, they subsequently found that the changes in corticospinal excitability caused by the current density of anode tDCS at 0.013 mA/cm2 were significantly larger than that at 0.029 mA/cm2 [45]. They believed that the current density at 0.013 mA/cm2 is sufficient to activate calcium channels and increase intracellular calcium content, which leads to neuron depolarization. But they also found that when the current density was above 0.029 mA/cm2, there was a direct relationship between the current density and the corticospinal excitability changes. This finding is partially in agreement with Nitsche et al. The difference could be explained in two aspects. On the one hand, the stimulation duration of this study was longer than that of Nitsche et al.’s. On the other hand, different electrode sizes were used in the studies of Bastani et al. (24cm2) and Nitsche et al. (35cm2), respectively. In addition, the higher the current density, the deeper the electrical field penetrated, which could change the excitability of the undamaged neurons. If the electrode size was too large, it not only stimulated the target region but also influenced the adjacent cortex. Moreover, there is a direct relationship between current density and side effects [45]. The accumulated toxic substance in sponge electrodes may also cause anodal skin lesions [40]. Therefore, an optimal but not maximum current density may exist, which could produce the best therapeutic effect for stroke patients. This is an issue that should be resolved in the future studies.

The same as the current density, the treatment session also influences the effect of tDCS. In this study, we found that the effect of on upper limb function recovery in stroke patients was significantly higher than that of other sessions both with anode and cathode stimulation. This coincided with the conclusion of Chhatbar et al., in which a dose-response relationship was not found in the number of session [43]. Lindenberg et al. also showed that the linear response was not necessarily existed between session and tDCS effect [46]. Therefore, it is not that the number of sessions the patient accepted, but the better the outcome will be. In terms of session, few researches have discussed it. Therefore, more studies are needed to explore this question further.

Prior to this study, a few meta-analyses were published on the recovery of lower extremity motor function after stroke. In our study, we found that bilateral tDCS significantly improved lower limb function in subacute stroke, as reported in the studies of Saeys et al. and Tahtis et al. They both suggested that bihemispheric stimulation made a good effect to lower limb function in subacute stroke [47, 48]. Bilateral tDCS reduces the excitability of the contralesional cortex and improves that of the ipsilesional cortex by placing anode on the affected side and cathode on the unaffected side. Therefore, bilateral tDCS is more conductive to reaching balance between the cerebral hemispheres. Feng et al. and Vines et al. also suggested that tDCS stimulated motor cortex simultaneously which was ideal to improve motor function [36, 49]. A suggestion about tDCS montage was put forward, prompting that bilateral stimulation was better than anode or cathode alone [11, 49, 50]. In a recent meta-analysis of lower extremities, tDCS performed well in mobility and muscle strength in patients with subacute stroke, but poorly in walking speed and balance function [26]. This was consistent with a part of our results. In our study, we also analyzed the polarity of tDCS but did not carry out a more detailed subgroup analysis. Several papers have mentioned that tDCS could increase the neural plasticity, improve motor function during spontaneous recovery, and reach maximum recovery in the first three months [34, 51]. This coincides with our results; that is, tDCS has a better therapeutic effect on subacute stage.

5.1. Limitation

There are still many details that could be improved in our meta-analysis. For example, only English studies were included in this study that may lead to publication bias. We did not limit the lesion of stroke (cortical or subcortical), nor did we summarize the follow-up results. In addition, most of the included studies enrolled ischemic stroke patients; whether these results are suitable for patients with hemorrhagic stroke still needs to be discussed further. In future studies, these mentioned aspects should be paid more attention.

6. Conclusion

tDCS is effective for the recovery of stroke patients with limb dysfunction after the first unilateral stroke, but the optimal parameters of tDCS for the upper and lower limbs are different. tDCS has a great impact on the recovery of upper limb function in chronic stroke patients. In addition, stroke patients with upper limb hemiplegia recover better by using anode or cathode tDCS with above 0.029 mA/cm2 current density and ≤10 sessions of treatment. But for the recovery of lower limb function, subacute stroke patients benefit more from bilateral tDCS.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Authors’ Contributions

XB and ZG designed and wrote this study. XB, ZG, and LH performed the statistical analysis and analyzed the data. LR, ZG, and MM contributed in modifying the article. QM reviewed and contributed to the full manuscript. Xi Bai and Zhiwei Guo contributed equally to this work.

Acknowledgments

This work was supported by the National Natural Science Foundation of China (no. 81271559).