Skip to main content
  • Research article
  • Open access
  • Published:

The mid-long term results of reconstructional cage and morselized allografts combined application for the Paprosky type III acetabular bone defects in revision hip arthroplasty

Abstract

Background

Severe acetabular bone defects is a complex problem in revision hip arthroplasty, cage is one of the reconstruction options. The purpose of this study is to report the mid-long term clinical and radiographic results of Paprosky type III acetabular bone defects revised with reconstructional cage and morselized allogeneic cancellous bone graft without impaction.

Methods

We retrospectively analyzed 28 patients who underwent revision hip arthroplasty with reconstructional cage and allogeneic cancellous bone graft between January 2007 and January 2016. There were 13 Paprosky type IIIA bone defect patients and 15 Paprosky type IIIB bone defect patients and 4 patients of the 15 were also with pelvic discontinuity. Clinical assessment included Harris Hip Score (HHS) and Short Form-12 (SF-12). Radiographic assessment included center of rotation, cage migration, and bone graft incorporation.

Results

All patients were followed up with a mean follow-up of 79.5 months (range 38–141), HHS improved from 31.4 (13–43) points preoperatively to 84.6 (55–94) points at last follow-up and SF-12 also improved significantly. There was 1 re-revision for the cage loosening and screw breakage at 61 months after surgery, and 2 patients had nonprogressive radiolucency in zone III and the junction of zone II and zone III at the bone implant interface.

Conclusion

The reconstructional cage combining with morselized allografts without impaction achieves a good result with a high complete allograft incorporation rate in Paprosky type III acetabular bone defects.

Peer Review reports

Introduction

In revision hip arthroplasty, severe acetabular bone defect is a complex problem with the goals of achieving stable and durable fixation of the acetabular component, restoring acetabular bone stock and reconstructing the hip rotation center [1]. There are several reconstruction options to choose, including impaction bone grafting and cemented cup [2], hemispheric acetabular component [3, 4], porous metal augments [5,6,7], ring and reconstruction cage [8, 9], oblong components [10], cup-cage reconstruction [11,12,13], and custom triflange implants [14, 15].

The porous hemispherical components provide structure for the bone ingrowth in order to achieve firmly fixation and have satisfactory follow-up results [5,6,7]. But when the acetabular bone defect is severe, placing the acetabular components to anatomical position and simultaneously achieving stable fixation may be difficult. In this situation, reconstructional cage is an alternative option [16].

Previous reports of reconstructional cage show a good mid to long-term results in acetabular revision arthroplasty [8, 9, 17, 18]. When combining with bone allografts, cage can bridge the bone defect to protect the underlying allograft during the bone remodeling phase. This may contribute to restoring acetabular bone stock and further revision surgery [19]. However, these studies mixed the results of Paprosky type II and III bone defects [8, 17, 18], and the result of reconstructional cage in Paprosky type III bone defects was not very clear.

Gamma irradiation is wildly used for allograft sterilization in tissue banks, and its effectiveness and safety has been confirmed. But it can result in a decrement in the mechanical strength of the allograft and affect the biological performance of allograft [20]. Povidone-iodine has good sterilization ability, and it has advantages in maintaining the tissue viability of allograft when used for allograft sterilization [21,22,23]. At the same time, the process of allograft sterilization with povidone-iodine is relatively simple comparing with gamma irradiation. Therefore povidone-iodine may be an alternative option for allograft sterilization.

The purpose of this study is to report the mid-long term clinical and radiographic results of using reconstructional cage and morselized allogeneic cancellous bone graft without impaction for Paprosky type III acetabular bone defects in acetabular revision and introduce our experience in bone allografts sterilization.

Methods and patients

This study was approved by the Ethics Committee of our institution. We systematically searched the patients whose diagnosis included acetabular bone defects in the joint replacement registration system of our hospital from January 2006 to January 2016. There were 158 patients diagnosed with type III acetabular bone defects according to the Paprosky classification [24], 28 of whom underwent revision hip arthroplasty with reconstructional cage and morselized allogeneic cancellous bone graft. The preoperative and postoperative clinical and radiographic examinations and surgical data of these 28 patients were available.

Twenty-eight patients had 28 revision hips. Thirteen patients had a type IIIA bone defect and 15 patients had a type IIIB bone defect (4 of these 15 patients had pelvic discontinuity). The type of the acetabular defects was determined by preoperative radiographic examination and intraoperative assessments. There were 13 males and 15 females whose average age at revision was 56.4 years (range 36–75) and their average body mass index was 23.9 kg/m2 (range 18.3–29.6). Twenty-three had left hip involvement and 5 had right hip involvement. Twenty-one were total hip revision and 7 were acetabular revision, and 5 had primary total hip replacement or hip revision on the opposite side. The main cause of revision was aseptic loosening (AL) including 25 patients and 3 of periprosthetic infection. The initial diagnosis of these patients was osteoarthritis in 23 cases, posttraumatic osteoarthritis in 1 case, femoral head necrosis in 2 cases, osteoarthritis secondary to tuberculosis of the hip in 1 case, and osteoarthritis secondary to hip pyogenic infection in 1 case. In this operation, 23 hips had first revision, 4 had second revision, one had third revision, and one had fourth revision arthroplasties (Table 1). Before surgery, C-reactive protein, Interleukin-6 and erythrocyte sedimentation rate were obtained for every patient. If the infection can’t be ruled out, hip aspiration would be performed. If the acetabular component enters into the pelvis, the iliac artery angiography would be performed.

Table 1 Demographics of Patients

Surgical technique

The revision arthroplasty was performed by 5 senior surgeons in a laminar flow operating room. The posterolateral approach was used in all patients. First, the original acetabular component was exposed and removed. Curets, osteotomes, and hemispherical reamers were used to debride cement and scarred capsular tissue to fully expose the acetabulum and achieve a well-vascularized bone bed, at this point surgeon would assess whether hemispheric and augments or other materials can be used to complete the revision. In this step, attention should be paid to preserve the bone stock. At the same time, in other aseptic table, assistants started preparing the cryopreserved allogeneic cancellous bone which was previously stored at − 80 °C for at least 3 months. First, assistants soaked the bone in 5% povidone-iodine solution for 30 min and then made it into morselized bones with a diameter of about 0.5 cm–1 cm. Second, the bones were soaked in 5% povidone-iodine solution for 15 min again. Third, assistants washed the morselized bones with normal saline and then dipped them in 5 mg/ml vancomycin solution for 10 min. After that, the morselized bones were mixed with 500 mg vancomycin to spare. The amount of cancellous bone used from femoral heads or tibial plateau depends on the defect size. When the bone bed was ready, the morselized bones were filled into the cavitary defects and the surgeon reversely reamed them not very tightly. The flanges of the reconstruction cage (Zimmer Inc., Warsaw, IN, USA) were bent and shaped to fit the specific anatomy of the grafted acetabulum. The superior flange was fixed to the iliac bone with cancellous bone screws, and the inferior flanges were fixed to the ischium and the pubis. The cement was placed in the cage and pressed to make it exude on the edge of cage, which was to ensure that the cement penetrated uniformly into the gap between allograft bone bed and cage. Polyethylene cup was then cemented into the cage with an appropriate anteversion and abduction angle. Fifty-two mm (range 52–64) cages were most commonly used and the 28-mm metal femoral heads were used in all cases. Average of 7.2 (range 5–10) screws per cage were used.

Postoperative management

All patients received cefuroxime and vancomycin to 3 days after operation. Enoxaparin was used to discharge followed by rivaroxaban for 3 weeks and pneumatic compression device was used to 24 h after operation. Patients began training the quadriceps femoris strength, hip flexion and hip abduction at the first day after operation and making touch-down weight bearing at two or 3 days after operation. Partial weight bearing began at 6 weeks after the operation and then transfers to full weight-bearing gradually. The patients were advised to avoid forced internal rotation and keep slight abduction with use of a wedged pillow for 3 months. Clinical and radiographic evaluation were performed at 3 months, 6 months, and 1 year after the operation, and then once a year until last follow-up.

Clinical assessment included Harris Hip Score (HHS) [25], Short Form-12 (SF-12) [26], and complications. For HHS, both pre and postoperative were obtained, 90 to 100 points were defined as “excellent”, 80 to 89 points were defined as “good”, 70 to 79 points were defined as “fair”, and lower than 70 points were defined as “poor”. For SF-12, physical and mental component were evaluated independently.

Radiographic assessment was accomplished by taking standard anteroposterior radiographs of pelvis and anteroposterior and lateral radiographs of the hip at each follow-up of all patients, and if necessary, 3-dimensional computed tomography of the hip would be obtained. We measured the hip center of rotation in standard anteroposterior radiographs of pelvis [24]. The distance between femoral head center and reference line through the teardrop figure is defined as vertical distance (VD) and the distance between femoral head center and perpendicular reference line through the teardrop is defined as horizontal distance (HD), the changes of which is defined as vertical migration (VM) or horizontal migration (HM) (Fig. 1). According to the criteria of Gill et al. [27], more than 5 mm cage migration in the horizontal or vertical, screw breakage and progressive radiolucent lines present at the cage–bone interface medially and superiorly or around the screws were defined as loosening. As Gross et al. reported [28], incorporation of the allograft was defined radiologically by the presence of trabecular crossing the graft–host interface. The graft resorption was evaluated by anteroposterior radiographs and was graded as minor (<1/3 of graft resorbed), moderate (1/3 to 1/2 of graft resorbed), and severe (>1/2 of graft resorbed). We also described the graft resorption in the three zones of acetabulum defined by DeLee and Charnley [29].

Fig. 1
figure 1

VD, vertical distance; HD, horizontal distance

Statistical analysis

Quantitative data were presented as mean values ± standard deviation. Statistical package SPSS version 22 (SPSS version 22; IBM Corporation, USA) was used to perform statistical analyses. The pre and postoperative clinical and radiological data were compared using a paired Student’s t-test. P < 0.05 was considered to be statistically significant.

Result

Clinical results and complications

All patients were followed up with a mean follow-up of 79.5 months (range 38–141). We had 1 re-revision, the implant survival with acetabular re-revision as the end point is shown in Fig. 2. The HHS improved significantly from 31.4 (13–43) points preoperatively to 84.6 (55–94) points at the last follow-up (p < 0.01), in which 7 (25%) patients had an excellent score; 16 (57%) had a good score; 4 (14%) had a fair score; and 1 (4%) had a poor score (55 points) which was performed re-revision as mentioned later. Compared with preoperative, the SF-12 at the last follow-up has improved significantly (Table 2). There was 1 recurrent dislocation at 8 months after operation treated with plaster immobilization for 3 months with no re-dislocation afterwards and HHS of the patient was 85 points at the last follow-up, 1 sciatic nerve palsy recovered partially and the HHS of the patient was 72 points at the last follow-up, 1 acute renal injury was successfully treated, and 1 femoral prosthesis loosening at the 2nd years after operation treated with femur re-revision, whose acetabular prosthesis was stable and the HHS of the patient was 87 points at the last follow-up. There was no periprosthetic joint infection, no deep vein thrombosis, no vessel damage, and no complain about limbs length discrepancy (Table 3).

Fig. 2
figure 2

Kaplan-Meier reconstructional cage survivorship analysis with re-revision as the end point is shown

Table 2 Preoperative and postoperative comparison of Clinical and Radiological evaluation
Table 3 Post-operative complications

With acetabular components inserting into the pelvis, iliac angiography was performed on one of the patients and found that the acetabulum prosthesis compressed the internal iliac artery, so we performed internal iliac artery embolization before operation. The operation of the patient was smooth.

Radiological results

As for the hip center of rotation, the horizontal distance was corrected from preoperative 42.1 mm (range 15.2–61.5) to postoperative 42.7 mm (range 34.3–53.5) (P > 0.05). The vertical distance was corrected from preoperative 47.9 mm (range 15.8–78.0) to postoperative 22.3 mm (range 12.2–40.5) (P < 0.05). There was only one (4%) patient with postoperative vertical distance more than 35 mm which was defined as a high hip center [30]. Comparing with 23 (82%) patients whose preoperative vertical distance was more than 35 mm, the hip center of rotation was improved obviously. There was no significant difference between postoperative and last follow-up horizontal distance (43.1 mm, range 34.1–56.9) (P > 0.05), and horizontal migration from postoperative to last follow-up was 1.4 mm (range 0.1–9.6). There was significant difference between postoperative and last follow-up vertical distances (23.6 mm, range12.4–54.3) (P < 0.05), and vertical migration from postoperative to last follow-up was 1.3 mm (range 0–13.8) (Table 2). Although the difference between postoperative and last follow-up vertical distances was significant, there was only 1 patient whose vertical migration (13.8 mm) and horizontal migration (9.6 mm) were both more than 5 mm at the last follow-up. And the cage of this patient was loosening with one screw breakage at 61 months after surgery, we performed acetabular re-revision surgery using jumbo cup and tantalum augment (Fig. 3). For 2 patients (7%), nonprogressive radiolucency appeared at the bone implant interface, the width of which was less than 2 mm. The radiolucency of 1 patient was in the junction of DeLee and Charnley zone II and zone III and the other patient was in DeLee and Charnley zone III. And according to Gross et al. [28], the resorption of these 2 patients was graded as minor. Complete incorporation was encountered in 25 patients (Fig. 4).

Fig. 3
figure 3

Radiographs of a 51-year-old woman with Paprosky IIIB acetabular bone defects and pelvic discontinuity was found intraoperatively. a Preoperative radiograph. b Immediate postoperative radiograph showed reconstruction cage and morselized allografts reconstructed the bone defect. c Radiograph at 61 months after revision suegery, the cage was loosening with one screw breakage. It was found intraoperatively that allograft was partially incorporated with the host bone and the pelvic discontinuity was healing. d Radiograph after re-revision with jumbo cup and tantalum augment

Fig. 4
figure 4

Radiographs of a 43-year-old woman with Paprosky IIIB acetabular bone defects and pelvic discontinuity. a Preoperative radiograph. b Immediate postoperative radiograph showed reconstruction cage and morselized allografts reconstructed the bone defect. c Radiograph at 96 months after revision suegery show that the cage remained stable and the allograft was completely incorporated with the host bone

Discussion

Severe acetabular bone defects and pelvic discontinuity are extremely complicated and challenging in revision arthroplasty. In this study, the acetabular bone defects of all patients were too large to treat with the combination of hemispheric cup and augments, therefore we used reconstructional cage and morselized allogeneic cancellous bone to reconstruct the bone defects. The mid-long term follow-up clinical and radiographic results is successful.

In our study, one patient (4%) with pelvic discontinuity suffered re-revision for the cage loosening with one screw breakage at 61 months after surgery, but we found that the allograft bone was partially incorporated with the host bone and the pelvic discontinuity was healing, and we performed the re-revision with jumbo cup and tantalum augment. Abolghasemian et al. [31] reported that they performed 50 hips acetabular re-revision surgery who used structural or morselized allograft bone with a cage or ring for previous revision, and they found that a simple revision without using allograft, augments, rings or cages could be performed in 31 (62%) hips and 17 hips (34%) owing to the restoration of bone stock. In prior review by Baauw et al. [32], the average re-revision rate of large acetabular defects revised with antiprotrusio cage in 8 studies including 315 hips is 3.5%, which is similar to the results of this study.

In revision arthroplasty, the use of allografts is related to a high risk for infection, which remains as an important cause of reoperation [9, 18, 19, 32,33,34]. According to Aponte-Tinao et al. [35], their average 106 months follow-up of 673 patients using massive bone allografts showed that 60 patients (9%) had a bacterial infection of the allograft. The allograft we used was from the bone bank of our province and was stored at − 80 °C, we sterilized it with povidone-iodine and vancomycin solution before surgery. It is well-known that polyvidone has excellent antimicrobial efficacy to gram-positive bacteria, fungi, and bacterial endospores. Polyvidone was widely used to sterilize the dropped bone graft, Bauer et al. [21] and Soyer et al. [22] showed that 10% povidone-iodine not only had good sterilization ability but also had a relative advantage in maintaining the tissue viability of the bone. In recent years, the animal testing of Jiang et al. [23] and Zhao et al. [20] found that povidone-iodine could promote osteogenesis and could protect the properties of allogenic bone compared with commonly used irradiation. Buttaro et al. [36] used cancellous bone allograft with vancomycin in revision hip arthroplasty and they found that this method did not affect allograft incorporation, had no nephrotoxicity and seemed to be beneficial by preventing infection. In our study, there was no infection, but we should consider that we had a smaller sample size. In summary, according to our follow-up results, the method we used to sterilize allograft has a simple procedure, don’t affect bone incorporation, and has a good disinfection effect.

In this series, we just used reamer reversely reamed the morselized bone intraoperatively, which is similar to Ding et al. [17]. In their series, 29 hips with an average follow-up of 73 months had a good mid-term outcome with no patient need re-revision and 23 hips achieved complete incorporation. And in our study, complete incorporation was encountered in 25 patients (89%), which achieved good outcome and seems better than Ding (79%) [17]. In previous studies, mid-term result of impaction bone grafting combining with cage showed the failure rate was 0–16% [8, 33, 37]. Recently, Akel et al. reported a long-term result of this combination, the failure rate was 8.1% [38]. Although the results of these studies were good, the results mixed Paprosky type II and III bone defects. Our study shows that reconstructional cage and morselized allografts is also a good option for Paprosky type III bone defects in acetabular revision.

In this series, one patient had experienced sciatic nerve palsy after the surgery, which gradually recovered by using an ankle brace. In some prior studies [9, 12, 13, 18], this complication was also reported with an incidence lower than 3%. However, in complicated acetabular revision, it seems impossible to completely avoid sciatic nerve palsy. Limiting dissecting posterior and inferior soft tissue of ischium may be conducive to reduce possibility of postoperative sciatic nerve palsy. Also, there was 1 recurrent dislocation in this series. Winter et al. [37] summarized that using lateral approach and strictly arranging rehabilitation plan may attribute to reduce dislocation rate and we think that appropriate anteversion and abduction angle of the cup is also important.

As a retrospective and observational study, there are several limitations. First, like most of the previous studies, this study lacks a control group using different devices, so we can just draw a general conclusion by comparing with previous similar studies. Second, we assess the allograft incorporation by radiograph which unable to display the central part of the allograft. The developing technique of reducing metal artifact CT may be useful. Third, our study is a mid-long term follow-up; and longer term follow-up is required to evaluate the outcome. But to our best knowledge, the clinical follow-up outcome of the way we sterilize bone allograft is barely reported.

Conclusion

In this study, the reconstructional cage combining with morselized allografts without impaction achieves a good result with a high complete allograft incorporation rate in Paprosky type III acetabular bone defects, which restores acetabular bone stock and may be beneficial to further revision. But in patients with pelvic discontinuity, this method should be used cautiously. Our mid-term follow-up outcome indicates that sterilizing bone allograft with povidone-iodine and vancomycin is a simple and effective way, but long-term follow-up and large sample studies are required to further evaluate the efficiency.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

HHS:

Harris Hip Score

SF-12:

12-item short-form health survey questionnaire

References

  1. Deirmengian GK, Zmistowski B, O'Neil JT, Hozack WJ. Management of acetabular bone loss in revision total hip arthroplasty. J Bone Joint Surg Am. 2011;93(19):1842–52.

    Article  PubMed  Google Scholar 

  2. Schmitz M, Hannink G, Gardeniers JWM, Verdonschot N, Slooff T, Schreurs BW. Acetabular reconstructions with impaction bone-grafting and a cemented cup in patients younger than 50 years of age: a concise follow-up, at 27 to 35 years, of a previous report. J Bone Joint Surg Am. 2017;99(19):1640–6.

    Article  PubMed  Google Scholar 

  3. Lian YY, Yoo MC, Pei FX, Kim KI, Chun SW, Cheng JQ. Cementless hemispheric acetabular component for acetabular revision arthroplasty: a 5- to 19-year follow-up study. J Arthroplast. 2008;23(3):376–82.

    Article  CAS  Google Scholar 

  4. Park DK, Della Valle CJ, Quigley L, Moric M, Rosenberg AG, Galante JO. Revision of the acetabular component without cement. A concise follow-up, at twenty to twenty-four years, of a previous report. J Bone Joint Surg Am. 2009;91(2):350–5.

    Article  PubMed  Google Scholar 

  5. Flecher X, Appy B, Parratte S, Ollivier M, Argenson JN. Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips. Int Orthop. 2017;41(5):911–6.

    Article  PubMed  Google Scholar 

  6. Jenkins DR, Odland AN, Sierra RJ, Hanssen AD, Lewallen DG. Minimum five-year outcomes with porous tantalum Acetabular cup and augment construct in complex revision Total hip Arthroplasty. J Bone Joint Surg Am. 2017;99(10):e49.

    Article  PubMed  Google Scholar 

  7. O'Neill CJ, Creedon SB, Brennan SA, O'Mahony FJ, Lynham RS, Guerin S, Gul R, Harty JA. Acetabular revision using trabecular metal augments for Paprosky type 3 defects. J Arthroplast. 2018;33(3):823–8.

    Article  Google Scholar 

  8. Hosny HAH, El-Bakoury A, Fekry H, Keenan J. Mid-term results of graft augmentation prosthesis II cage and impacted allograft bone in revision hip Arthroplasty. J Arthroplast. 2018;33(5):1487–93.

    Article  Google Scholar 

  9. Ilyas I, Alrumaih HA, Kashif S, Rabbani SA, Faqihi AH. Revision of type III and type IVB acetabular defects with Burch-Schneider anti-Protrusio cages. J Arthroplast. 2015;30(2):259–64.

    Article  Google Scholar 

  10. Landor I, Vavrik P, Jahoda D, Pokorny D, Tawa A, Sosna A. The long oblique revision component in revision arthroplasty of the hip. J Bone Joint Surg Bri Vol. 2009;91(1):24–30.

    Article  CAS  Google Scholar 

  11. Abolghasemian M, Tangsaraporn S, Drexler M, Barbuto R, Backstein D, Safir O, Kuzyk P, Gross A. The challenge of pelvic discontinuity: cup-cage reconstruction does better than conventional cages in mid-term. Bone Joint J. 2014;96-b(2):195–200.

    Article  CAS  PubMed  Google Scholar 

  12. Sculco PK, Ledford CK, Hanssen AD, Abdel MP, Lewallen DG. The evolution of the cup-cage technique for major Acetabular defects: full and half cup-cage reconstruction. J Bone Joint Surg Am. 2017;99(13):1104–10.

    Article  PubMed  Google Scholar 

  13. Amenabar T, Rahman WA, Hetaimish BM, Kuzyk PR, Safir OA, Gross AE. Promising mid-term results with a cup-cage construct for large Acetabular defects and pelvic discontinuity. Clin Orthop Relat Res. 2016;474(2):408–14.

    Article  PubMed  Google Scholar 

  14. Gladnick BP, Fehring KA, Odum SM, Christie MJ, DeBoer DK, Fehring TK. Midterm survivorship after revision Total hip Arthroplasty with a custom Triflange Acetabular component. J Arthroplast. 2018;33(2):500–4.

    Article  Google Scholar 

  15. Taunton MJ, Fehring TK, Edwards P, Bernasek T, Holt GE, Christie MJ. Pelvic discontinuity treated with custom triflange component: a reliable option. Clin Orthop Relat Res. 2012;470(2):428–34.

    Article  PubMed  Google Scholar 

  16. Makinen TJ, Fichman SG, Watts E, Kuzyk PR, Safir OA, Gross AE. The role of cages in the management of severe acetabular bone defects at revision arthroplasty. Bone Joint J. 2016;98-b(1 Suppl A):73–7.

    Article  CAS  PubMed  Google Scholar 

  17. Ding H, Mao Y, Yu B, Zhu Z, Li H, Yu B, Huang J. The use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up. J Orthop Surg Res. 2015;10:77.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Regis D, Magnan B, Sandri A, Bartolozzi P. Long-term results of anti-protrusion cage and massive allografts for the management of periprosthetic acetabular bone loss. J Arthroplast. 2008;23(6):826–32.

    Article  Google Scholar 

  19. Sembrano JN, Cheng EY. Acetabular cage survival and analysis of factors related to failure. Clin Orthop Relat Res. 2008;466(7):1657–65.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Zhao Y, Hu X, Li Z, Wang F, Xia Y, Hou S, Zhong H, Zhang F, Gu N. Use of polyvinylpyrrolidone-iodine solution for sterilisation and preservation improves mechanical properties and osteogenesis of allografts. Sci Rep. 2016;6:38669.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Bauer J, Liu RW, Kean TJ, Dennis JE, Petersilge W, Gilmore A. A comparison of five treatment protocols for contaminated bone grafts in reference to sterility and cell viability. J Bone Joint Surg Am. 2011;93(5):439–44.

    Article  PubMed  Google Scholar 

  22. Soyer J, Rouil M, Castel O. The effect of 10% povidone--iodine solution on contaminated bone allografts. J Hosp Infect. 2002;50(3):183–7.

    Article  CAS  PubMed  Google Scholar 

  23. Jiang Y, Chen L, Zhang S, Tong T, Zhang W, Liu W, Xu G, Tuan RS, Heng BC, Crawford R, Xiao Y, Ouyang HW. Incorporation of bioactive polyvinylpyrrolidone-iodine within bilayered collagen scaffolds enhances the differentiation and subchondral osteogenesis of mesenchymal stem cells. Acta Biomater. 2013;9(9):8089–98.

    Article  CAS  PubMed  Google Scholar 

  24. Sheth NP, Nelson CL, Springer BD, Fehring TK, Paprosky WG. Acetabular bone loss in revision total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2013;21(3):128–39.

    Article  PubMed  Google Scholar 

  25. Singh JA, Schleck C, Harmsen S, Lewallen D. Clinically important improvement thresholds for Harris hip score and its ability to predict revision risk after primary total hip arthroplasty. BMC Musculoskelet Disord. 2016;17:256.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Yadegari I, Bohm E, Ayilara OF, Zhang L, Sawatzky R, Sajobi TT, Lix LM. Differential item functioning of the SF-12 in a population-based regional joint replacement registry. Health Qual Life Outcomes. 2019;17(1):114.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Gill TJ, Sledge JB, Muller ME. The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devices. J Arthroplast. 2000;15(1):1–7.

    Article  CAS  Google Scholar 

  28. Gross AE. Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999;369:198–207.

    Article  Google Scholar 

  29. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.

    Google Scholar 

  30. Antoniades J, Pellegrini VD Jr. Cross-sectional anatomy of the ilium: implications for acetabular component placement in total hip arthroplasty. Clin Orthop Relat Res. 2012;470(12):3537–41.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Abolghasemian M, Sadeghi Naini M, Tangsataporn S, Lee P, Backstein D, Safir O, Kuzyk P, Gross AE. Reconstruction of massive uncontained acetabular defects using allograft with cage or ring reinforcement: an assessment of the graft's ability to restore bone stock and its impact on the outcome of re-revision. Bone Joint J. 2014;96-b(3):319–24.

    Article  CAS  PubMed  Google Scholar 

  32. Baauw M, van Hooff ML, Spruit M. Current Construct Options for Revision of Large Acetabular Defects: A Systematic Review. JBJS Rev. 2016;4(11):1.

    Article  Google Scholar 

  33. Marx A, Beier A, Richter A, Lohmann CH, Halder AM. Major acetabular defects treated with the Burch-Schneider antiprotrusion cage and impaction bone allograft in a large series: a 5- to 7- year follow-up study. Hip Int. 2016;26(6):585–90.

    Article  PubMed  Google Scholar 

  34. Hansen E, Shearer D, Ries MD. Does a cemented cage improve revision THA for severe acetabular defects? Clin Orthop Relat Res. 2011;469(2):494–502.

    Article  PubMed  Google Scholar 

  35. Aponte-Tinao LA, Ayerza MA, Muscolo DL, Farfalli GL. What are the risk factors and management options for infection after reconstruction with massive bone allografts? Clin Orthop Relat Res. 2016;474(3):669–73.

    Article  PubMed  Google Scholar 

  36. Buttaro M, Comba F, Piccaluga F. Vancomycin-supplemented cancellous bone allografts in hip revision surgery. Clin Orthop Relat Res. 2007;461:74–80.

    PubMed  Google Scholar 

  37. Winter E, Piert M, Volkmann R, Maurer F, Eingartner C, Weise K, Weller S. Allogeneic cancellous bone graft and a Burch-Schneider ring for acetabular reconstruction in revision hip arthroplasty. J Bone Joint Surg Am Vol. 2001;83-a(6):862–7.

    Article  Google Scholar 

  38. Akel I, Caglar O, Tokgozoglu AM, Atilla B. Titanium cage reconstruction of acetabular defects in revision hip arthroplasty results in favourable outcomes: up to 17 years follow-up. Hip Int. 2019:1120700019855870. [Epub ahead of print].

Download references

Acknowledgements

We would like to thank the relevant staff for guidance and assistance for their support and collaboration in our hospital.

Funding

No funding was obtained for this study.

Author information

Authors and Affiliations

Authors

Contributions

ZZ and FP conceived and designed this study; QX, HW collected the data; QX and DW performed the statistical analysis; QX prepared Table 1; QX and TL prepared Figs. 1 and 2; QX wrote the manuscript; QX, KZ, DW, and ZZ revised this manuscript. All authors reviewed the final manuscript. All authors agree to be accountable for all aspects of the work.

Corresponding author

Correspondence to Zongke Zhou.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the local institutional review board of West China Hospital, Sichuan University (No. 201302008). Written informed consent (including patients’ details, images or videos) was obtained from all participants. All experiments were performed in accordance with relevant guidelines and regulations. This study was conducted in accordance to the Declaration of Helsinki.

Consent for publication

We have obtained written consent (including patients’ details, images or videos) for publication from the participants.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xiao, Q., Wang, H., Zhou, K. et al. The mid-long term results of reconstructional cage and morselized allografts combined application for the Paprosky type III acetabular bone defects in revision hip arthroplasty. BMC Musculoskelet Disord 20, 517 (2019). https://0-doi-org.brum.beds.ac.uk/10.1186/s12891-019-2915-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12891-019-2915-3

Keywords