A Legionnaires’ disease outbreak associated with cooling towers in Warstein, Germany, August 2013

Introduction

Legionnaires’ disease (LD) results mainly from inhalation of aerosols containing the bacterium Legionella pneumophila, which may cause atypical severe pneumonia. Between the 1st of August and 6th of September an unusual cluster of patients with LD of unknown etiology in Warstein, North Rhine-Westphalia, Germany was notified to the public health authorities.

Methods

Laboratory investigation was performed according to requirements of European case definition. A questionnaire had been used to narrow down possible sources of infection. A case-control study was conducted to identify possible sources of infection. Cases and controls were matched for age-group and sex. Odds ratio (OR), 95% confidence interval (CI) and p-values were calculated by logistic regression. Values of p<0.05 were considered statistically significant.

Results

The outbreak accounted for 159 suspected and 78 laboratory-confirmed cases including one death. Legionella pneumophila, serogroup 1, subtype Knoxville, sequence type 345, could be identified as the epidemic strain. Cases were 19 to 94 years old, 64% were males. The case fatality rate was 1.28%, 91% of cases were hospitalised, 17% of those needed intensive care. In univariable analysis cases were almost five times more likely to smoke than controls (OR 4.81; 95% CI 2.33-9.93; p<0.0001). Furthermore cases were twice as likely to live within a 3 km distance from one identified infection source as controls (OR 2.14; 95% CI 1.09-4.20; p<0.027).

Conclusion

This is the largest outbreak of LD in Germany to date. Due to a series of uncommon events, this outbreak was most likely caused by multiple sources involving industrial cooling towers. Quick epidemiological assessment, source tracing and shutting down potential sources as well as rapid laboratory testing and early treatment are necessary to reduce morbidity and mortality. Maintenance of cooling towers must be reliable to prevent such LD-outbreaks in the future

Disclosure of interest

None declared.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jurke, A., Maisa, A., Renken, F. et al. A Legionnaires’ disease outbreak associated with cooling towers in Warstein, Germany, August 2013. Antimicrob Resist Infect Control 4 (Suppl 1), P227 (2015). https://0-doi-org.brum.beds.ac.uk/10.1186/2047-2994-4-S1-P227