Skip to main content
  • Research article
  • Open access
  • Published:

Effect of surface finishing on the colour stability and translucency of dental ceramics

Abstract

Background

The purpose of this study was to investigate the effects of staining solutions and surface finishing on the colour stability and translucency of hybrid ceramic (HC) and resin nanoceramic (RNC) materials.

Methods

Twenty four groups consisting of 10 specimens (240 specimens in total) were created out of HC and RNC, including six groups to be stored in distilled water served as the controls groups. The Vita Enamic technical set, Shofu polishers, medium and fine rubber wheels and Sof-Lex polishing discs were used as polishing instruments. Cola, tea, and coffee were used as staining solutions. The colour differences (∆E*) and translucency parameter (TP) were evaluated by a spectrophotometer. Data were analysed by a One-way Analysis of Variance (ANOVA) and Mann-Whitney U test.

Results

There was a statistically significant difference between the ∆E* values of the HC specimens in the coffee groups and the ∆E* values of the other HC groups (p < 0.05). The ∆E* values of the RNC specimens in the coffee and tea groups were not different from the specimens in the cola groups (p > 0.05). The TP values of the polished groups were higher than the Sof-Lex groups and the Shofu groups on both HC and RNC materials (p < 0.05).

Conclusions

Increased ∆E* values were observed in HC specimens stored in a coffee solution compared to the specimens stored in a tea or cola solution. Both of the RNC specimens stored in coffee and tea had higher ∆E* values than the RNC specimens stored in the cola. The TP values of both HC and RNC specimens stored in the coffee solution decreased.

Peer Review reports

Background

Efforts to strengthen dental ceramics by modifying their microstructures have continued to increase in the last twenty years. Adding a crystalline structure to the glassy matrix of feldspathic porcelain reinforces both the optical and mechanical properties of the ceramic. Alumina- and zirconia-based systems are opaque, whereas leucite-reinforced systems are more translucent [1]. Zirconia-framework materials have low translucency properties because of zirconia’s opaque white colour. Also, feldspathic ceramics are used as a layer that mimics natural tooth colour. Enamic (Vita Zahnfabrik, Bad Sackingen, Germany), one of the polymer-infiltrated feldspathic ceramic materials, consists of 86% ceramic (by weight) [2]. Besides having the properties of both ceramic and composite materials, polymer-infiltrated ceramic-network (PICN) materials are considered to have mechanical and aesthetic properties similar to natural teeth [3]. Lava ultimate (Lava Ultimate; 3M Espe) is a strong, wear-resistant, and highly aesthetic milling block that provides an alternative to ceramic blocks for computer-aided design/computer-aided manufacturing (CAD/CAM) indirect restorations [4].

Smoother restoration surfaces create biologically ideal surfaces by minimising the effect of plaque accumulation and discolouration. If a restoration has a sufficiently smooth surface, it can prevent the formation of biofilm layers and extrinsic stains. When glaze surfaces deform during contour adjustments as incisal/occlusal or facial surfaces, clinical adjustments of the ceramic restorations are generally prone to create aesthetic problems for the patients.

Certainly, colour stability is an important clinical factor in aesthetic dental restorations [5, 6]. Also, the survival rate and aesthetic appearance of ceramic restorations depends on colour stability and translucency. The translucency of dental materials are defined as the translucency parameter (TP) [7]. TP describes the colour difference between a black and a white background. The Commision Internationale de I’Eclairage (CIE) recommends calculating colour difference based on the CIE L*a*b* colour parameters [8]. Color differences (∆E*) in CAD/CAM ceramics are affected by the translucency and the background color [9]. There is also only a limited knowledge on the effect of surface roughness on the color of ceramic after it has been subjected to a staining agent in the literature [10,11,12,14].

However, every single material has to be evaluated individually in regard to their mechanical and aesthetic properties. Limited data are available in the literature on the colour stability and translucency of newly introduced CAD/CAM milling blocks. Thus, the purpose of this study was to determine the effects of staining solutions and surface finishing on the colour stability and translucency of hybrid materials. The null hypothesis of this study was that both staining solutions and surface finishing are not correlated with the stainability and translucency of hybrid ceramics (HC) and resin nanoceramics (RNC).

Methods

Sampling

Two of the most popular CAD/CAM ceramics were chosen in this study. The selected HC and RNC materials are listed in Table 1. Using a precision saw machine, 1.2 mm–thick disk specimens with 14 mm diameters were prepared with high-translucence CAD/CAM blocks by slicing them with a water-cooled diamond disk (Micracut 201, Bursa, Turkey) at low speeds (150 rpm). The shades of the Enamic (Vita Enamic, Vita Zahnfabrik, Germany) specimens were characterised with a specially developed, white Vita Enamic Stains Kit (Vita Zahnfabrik, Germany) following the manufacturer’s instructions. The 2M2 colour for Enamic specimens was chosen according to the Vita 3D-Master shade guide (Vita Zahnfabrik, Germany) which corresponds with the Lava Ultimate (Lava Ultimate, 3M Espe, USA) specimens’ A2 colour according to the Vitapan Classical shade guide (Vita Zahnfabrik, Germany).

Table 1 Materials tested

As listed in Table 2, 24 groups consisting of 10 specimens (240 specimens in total) were created out of HC and RNC , including six groups to be stored in distilled water served as the controls groups (E1a,E2a, E3a, L1a, L2a, L3a) . All of the specimens’ surfaces were roughened on both sides with 600-, 800- and 1200-grit silicon carbide abrasive papers (English Abrasives, London, UK) under running water at 100 cycles per minute. This standardised polishing procedure eliminated external irregular scratches of the cut specimens and equally rounded the chipped corners [9]. The specimens in the E1b, E1c and E1d groups were then polished with the Vita Enamic technical polishing set (Vita Zahnfabrik, Bad Sackingen, Germany) following the manufacturer’s instructions for the. Specimens in groups L1b, L1c and L1d were polished with a low-speed hand piece at 10,000 rpm with medium and fine rubber wheels (Dedeco Red and Green Rubber Wheels, Dedeco, NY, USA). The specimens in the E2b, E2c, E2d, L2b , L2c and L2d groups were polished with 12.7 mm–diameter Sof-Lex polishing discs (3M Espe, MN, USA) mounted on a hand piece set at a speed of 10,000 rpm for coarse and medium discs and 30,000 rpm for fine and superfine discs according to the manufacturers’ recommendations. The specimens were polished in succession with a low-speed hand piece at 10,000 rpm with an abrasive stone(Dura Green Stones; Shofu Inc, Kyoto, Japan), a coarse silicon carbide polisher (Ceramaster Coarse; Shofu Inc), and a silicon carbide polisher (Ceramaster; Shofu Inc) in the groups E3b, E3c, E3d, L3b, L3c and L3d. All polishing instruments were applied on both sides of the specimens with a low-speed rotating hand piece (Kavo Ewl 4990; KaVo Dental Gmbh, Germany) by the same investigator.

Table 2 Materials, surface finishing and groups

Colour measurements

Before colour measurements were taken, all of the specimens were cleaned in deionised water for ten minutes in an ultrasonic cleaner (Pro-Sonic 600; Sultan Healthcare, NJ, USA) and then dried with compressed air. The thickness of the specimens were confirmed with a digital calliper (Absolute Digimatic, Mitutoyo, Japan). The baseline colour measurements were performed with a clinical spectrophotometer (Vita Easy Shade Advance, Vita Zahnfabrik, Germany) under standard illuminant D65 using CIE L*a*b* and were recorded before treatment with the staining solution. All measurements were performed on white, black and neutral grey surfaces. After repeating the colour measurements three times for each of the specimens, the mean values of L*, a* and b* were calculated. In the CIE L*a*b* system color differences (∆E*) formula, L* represent lightness, a* represents the chromaticity coordinate for red-green and b* represents the chromaticity coordinate for yellow-blue for color differences (∆E*) formula [8].

Translucency was determined by identifying the value of the TP. Measurements were performed with the spectrophotometer under D65 illumination over white and black backgrounds. Measurements were repeated three times, and the mean CIE L*a*b* values were recorded for both backgrounds. The TP was obtained by calculating the difference in colour between the specimen over a white and black background with the following formula [15, 16]:

$$ TP={\left({\left({L^{\ast}}_B-{L^{\ast}}_W\right)}^2+{\left({a^{\ast}}_B-{a^{\ast}}_W\right)}^2+{\left({b^{\ast}}_B-{b^{\ast}}_W\right)}^2\right)}^{1/2} $$

In this formula, B signifies the colour coordinates over a black background and W signifies the colour coordinates over a white background. The greater the TP value, the higher the translucency of the material. A TP value of 100 indicates the specimen is transparent and a TP value of 0 indicates that the material is opaque.

After the baseline colour measurements were made, the specimens were stored in four different solutions. The tea solution was prepared with 200 ml of boiling water poured over a 2 g tea bag (Lipton, Unilever, Turkey) according to the manufacturer’s recommendations. The coffee solution was made with 3.6 g of coffee (Nescafe Classic; Nestle, Bursa, Turkey) grounds and 300 ml of boiled water according to the manufacturers’ recommendations. The solution was filtered through a filter paper after 10 min of storing. A 48 h storage period was selected with reference to previous studies [17, 18]. The solution was stirred every 8 ± 1 hours. A Coca-Cola solution (The Coca-Cola Company, İstanbul, Turkey) was prepared with a can of 330 ml of Coca-Cola. Finally, distilled water served as the control group’s solution. All specimens were stored in 100 ml solutions at 37°C for 48 h. Then, the specimens were rinsed with distilled water for 5 min and blotted dry with tissue paper (Selpak; Eczacıbaşı, Istanbul, Turkey) before colour measurements.

The second set of colour measurements were made using the spectrophotometer with the same method as the first. The determination of the colour variation, ∆E*, between the two colour measurements was made in the CIE L*a*b* system using the following equation:

$$ \Delta {E}^{\ast }={\left({\left({L_1}^{\ast }-{L_2}^{\ast}\right)}^2+{\left({a_1}^{\ast }-{a_2}^{\ast}\right)}^2+{\left({b_1}^{\ast }-{b_2}^{\ast}\right)}^2\right)}^{1/2}. $$

To evaluate whether the colour differences in translucent ceramics were acceptable, this study used an average threshold of ∆E* = 2.7 [19].

Statistical analysis

Data are shown as mean and standard deviation. Three way Anova was used for main effects and interaction effects accoring to three factors. Bonferroni correction was used for multiple comparisons. With 80% power, 5% margin of error and effect size of 0.242, there are totally 240 samples obtain as 240/24 = 10 samples for each group. Analysis were conducted using commercial software (IBM SPSS Statistics 20, IBM Inc., Somers NY, USA). Values of p < 0.05 were considered significant.

Results

Colour differences

The one-way ANOVA test results and the means and standard deviations of ∆E* values are shown in Table 3. No significant differences in ∆E* values were detected between groups E1a, E2a, E3a, L1a, L2a and L3a, which were the six control groups (p > 0.05). Also, no significant differences in ∆E* values were observed within the polished HC groups (E1a, E1b, E1c, E1d), the Sof-Lex HC groups (E2a, E2b, E2c, E2d) or the Shofu HC groups (E3a, E3b, E3c, E3d) (p > 0.05 for all 3). The ∆E* values were significantly different among the polished RNC groups (L1a, L1b, L1c, L1d), the Sof-Lex RNC groups (L2a, L2b, L2c, L2d), and the Shofu RNC groups (L3a, L3b, L3c, L3d) (p < 0.05 for all 3). The ∆E* values of HC specimens in the polished group (E1d), Sof-Lex group (E2d) and Shofu group (E3d) that were stored in the coffee solution had statistically significant differences from the HC groups (p < 0.05). The ∆E* values of the RNC specimens in the polishing group (L1c, L1d), Sof-Lex group (L2c, L2d), and Shofu group (L3c, L3d) that were stored in the tea and coffee solutions were significantly different from the specimens in the groups (L1b, L2b, L3b) stored in the cola solution (p < 0.05). A comparison of the ∆E* values of the different groups of the HC and RNC materials are shown in Figs. 1 and 2.

Table 3 Mean and SD of ΔE values and differences between groups
Fig. 1
figure 1

Comparison of the ∆E values of different groups of HC material

Fig. 2
figure 2

Comparison of the ∆E values of different groups of RNC material

Translucency Parameter

The one-way ANOVA results and the means and standard deviations of the TP values are shown in Table 4. No significant differences in the TP values were detected between the specimens in the groups E1a, E2a, E3a, L1a, L2a and L3a which were stored in distilled water as the control groups (p > 0.05). However, these groups showed the highest TP values out of all HC and RNC groups. The TP values were significantly higher with the HC and RNC polished groups than the HC and RNC Sof-Lex groups and Shofu groups (p < 0.05). Also, the TP values of the HC and RNC specimens stored in the coffee solution were the lowest, which was significantly different than the specimens stored in cola, and tea (p < 0.05). The TP values of both HC and RNC specimens with polishing, Sof-Lex finishing and Shofu finishing that were stored in tea and cola were not significantly different from one another (p > 0.05). The RNC specimens also showed higher TP values than the HC specimens in all groups, and these values were statistically different from each other (p < 0.05). A comparison of the TP values of the different groups of HC and RNC materials are shown in Figs. 3 and 4.

Table 4 Mean and SD of TP values and differences between groups
Fig. 3
figure 3

Comparison of the TP values of different groups of HC material

Fig. 4
figure 4

Comparison of the TP values of different groups of RNC material

Discussion

Based on the results of this study, the null hypothesis that both staining solutions and surface finishing are not correlated with the stainability and translucency of HC and RNC materials was rejected. In this study, an increase in ∆E* values was observed in the cola, tea and coffee groups for both HC and RNC specimens but not for specimens stored in distilled water as the control group. These groups also exceeded the TP values of control groups. The TP values of these groups ranging from highest to lowest were those stored in the cola, tea and coffee solutions for both HC and RNC materials.

Johnston et al. [20] reported an acceptability threshold of ∆E* = 3.7 as a limit, and this limit has been referenced for many years. Many of the different studies on dental ceramics consider a range of ∆E* = 2 to 4 as the acceptability threshold. [5, 21, 22]. Also, colour perception is related to many factors, such as an individual’s colour perception, the material’s surface texture, illumination conditions and instrumental differences in colour matching [23]. In this study, the colour difference in translucent ceramics was accepted as ∆E* = 2.7, which has been reported as an average threshold value in previous studies [19]. There has been no clear agreement about the accepted ∆E* limit until the present day [23]. In the present study, the ∆E* values of HC and RNC materials stored in the coffee solution for all groups were higher than the accepted threshold ∆E* value. Also, this situation is valid for ∆E* values of HC and RNC materials stored in tea solutions for all groups finished with Sof-Lex and Shofu.

Several reports have investigated different polishing techniques for ceramic restorations to create smooth surfaces, such as glazing, and support the use of polishing as an alternative to glazing [9, 24,25,26]. Another, significant factor in colour stability is the type of surface treatment. [9, 19, 27, 28]. Coffee has been the most frequently used staining solution in colour studies followed by tea and cola [9, 17, 19, 25,26,27,28,29].

In a previous study that investigated the effects of tea, coffee and cola on the colour of resins and ceramics, it was reported that colour change of porcelain was not noticeable (ΔE*=1.2 to 1.4) [30]. In another study, a glazed ceramic material’s colour change after immersion in coffee was found to be less than a composite resin’s colour change [31].

In a recent study, Acar et al. [32] evaluated optical properties of nanocomposite resins and ceramics at various thicknesses due to thermocycling in coffee. They reported that thermocycling in coffee caused a clinically unacceptable colour change for Lava Ultimate and Filtek Supreme Plus, and the colour changes of Enamic were perceptible but clinically acceptable. Also, they concluded that when colour stainability with coffee is considered, Enamic may be an alternative to lithium disilicate ceramic restorations fabricated with minimally invasive techniques. Unlike the present study, a spectroradiometer was used to measure the spectral radiance of the specimens. A limitation of the present study was that thermal cycling was not used for coffee staining. However, like the present study, Lava Ultimate was showed more discolouration than the Enamic in Acar et al.’s study.

Similar to the present study, in a recent study Awad et al. [33] reported that Lava Ultimate was more translucent than Enamic with two different specimen thicknesses (1mm and 2mm). CAD/CAM ceramics at all 3 surface conditions, which were polished surfaces and surfaces grinded with 1200 grit and 500 grit SiC grinding sheets. Also, they concluded that Enamic achieved the lowest TP values because of the high amount of Al2O3 (approximately 23 wt%). Moreover, the material composition strongly influenced translucency. Lava Ultimate is an RNC containing 80 wt% silica and zirconia nanoparticles and nanoclusters bound in the resin matrix. The ceramic particles are made up of three different ceramic fillers that reinforce a highly cross-linked polymeric matrix, which is comprised of 20 nm silica and 4–11 nm zirconia particles. In a previous study, Lava Frame was found to be the most translucent material among the different zirconia materials by the direct transmission method and light flow [23, 30, 34].

Vita Enamic was reported to be the best choice for anterior and posterior restorations that closely matched neutral tooth colour in the literature [35]. In Enamic, the ceramic-network material is infiltrated with urethane dimethacrylates (UDMA) and triethylene glycol dimethacrylate (TEGDMA) mixture [36]. Because TEGDMA has higher water absorption, staining agents more easily penetrate the resin matrix. Therefore, the stainability of Enamic may be due to the TEGDMA content [37].

HC and RNC blocks are fabricated based on two levels of precrystallisation treatment. HT material contains a small number of large crystals in the precrystallised matrix, whereas LT material contains a large number of smaller crystals. Furthermore, opacity increases with the thickness for all ceramic materials. A TP range of 5.5 to 7.1 for highly translucent composites, 3.8 to 5.4 for moderately translucent composites, and 2.0 to 3.7 for more opaque composites [38]. As a limitation of this study, both HC and RNC specimens were prepared in a single thickness. Further studies are required to determine the TP of HC and RNC materials with different thicknesses.

Conclusions

Within the limitations of this in vitro study, the following conclusions were drawn: Increased ∆E* values were observed in HC specimens stored in a coffee solution compared to the specimens stored in a tea or cola solution. Both of the RNC specimens stored in coffee and tea had higher ∆E* values than the RNC specimens stored in the cola. The TP values of both HC and RNC specimens stored in the coffee solution decreased. RNC specimens showed higher TP values than HC specimens for all groups. Coffee has caused the most stained surfaces among tea and cola on HC and RNC. According to the results of the present study, Sof-Lex finishing and Shofu finishing of Enamic surfaces may be an alternative to finishing with Vita Enamic technical polishing set for handling less stainability of the material’s.

Abbreviations

%:

Percent

g:

Gram

h:

Hour

min:

Minute

ml:

Milliliter

mm:

Millimeter

rpm:

Revolutions per minute

3D:

3-Dimentional

wt:

Weight

References

  1. Sakaguchi RL, Powers JM. Craig’s Restorative Dental Materials. 13th ed. Philadelphia: Elsevier Mosby; 2012. p. 255.

    Google Scholar 

  2. Della Bona A, Corazza PH, Zhang Y. Characterisation of a polymer-infiltrated ceramic-network material. Dent Mater. 2014;30:564–9.

    Article  PubMed  Google Scholar 

  3. Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater. 2013;29:419–26.

    Article  PubMed  Google Scholar 

  4. Belli R, Geinzer E, Muschweck A, Petschelt A, Lohbauer U. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations. Dent Mater. 2014;30:424–32.

    Article  PubMed  Google Scholar 

  5. Seghi R, Johnston W, O'Brien W. Performance assessment of colorimetric devices on dental porcelains. J Dent Res. 1989;68:1755–9.

    Article  PubMed  Google Scholar 

  6. Heydecke G, Zhang F, Razzoog ME. In vitro color stability of double-layer veneers after accelerated aging. J Prosthet Dent. 2001;85:551–7.

    Article  PubMed  Google Scholar 

  7. Barizon KT, Bergeron C, Vargas MA, Qian F, Cobb DS, Gratton DG. Ceramic materials for porcelain veneers. Part I: Correlation between translucency parameters and contrast ratio. J Prosthet Dent. 2013;110:397–401.

    Article  PubMed  Google Scholar 

  8. Commission Internationale de l’Eclairage (CIE). CIE technical report: colorimetry. CIE Pub No. 2004;15:3.

    Google Scholar 

  9. Al Ben Ali A, Kang K, Finkelman MD, Zandparsa R, Hirayama H. The effect of variations in translucency and background on color differences in CAD/CAM lithium disilicate glass ceramics. J Prosthodont. 2014;23:213–20.

    Article  PubMed  Google Scholar 

  10. Motro PF, Kursoglu P, Kazazoglu E. Effects of different surface treatments on stainability of ceramics. J Prosthet Dent. 2012;108:231–7.

    Article  PubMed  Google Scholar 

  11. Yılmaz C, Korkmaz T, Demirköprülü H, Ergün G, Ozkan Y. Color stability of glazed and polished dental porcelains. J Prosthet Dent. 2008;17:20–4.

    Google Scholar 

  12. Atay A, Karayazgan B, Ozkan Y, Akyil MS. Effect of colored beverages on the color stability of feldspathic porcelain subjected to various surface treatments. Quintessence Int. 2009;40:41–8.

    Google Scholar 

  13. Esquivel JF, Chai J, Wozniak WT. Color stability of low-fusing porcelains for titanium. Int J Prosthodont. 1995;8:479–85.

    PubMed  Google Scholar 

  14. Muhammadibassir M, Rezvani MB, Golzari H, Salehi EM, Fahimi MA, Fard MJK. Effect of Two Polishing Systems on Surface Roughness, Topography, and Flexural Strength of a Monolithic Lithium Disilicate Ceramic. J Prosthodont. 2017;Mar 8; https://0-doi-org.brum.beds.ac.uk/10.1111/jopr.12586..

  15. Heffernan MJ, Aquilino SA, Diaz-Arnold AM, Haselton DR, Stanford CM, Vargas MA. Relative translucency of six all-ceramic systems. Part I: core materials. J Prosthet Dent. 2002;88:4–9.

    Article  PubMed  Google Scholar 

  16. Lee Y-K. Changes in the translucency of porcelain and repairing resin composite by the illumination. Dent Mater. 2007;23:492–7.

    Article  PubMed  Google Scholar 

  17. Guler AU, Kurt S, Kulunk T. Effects of various finishing procedures on the staining of provisional restorative materials. J Prosthet Dent. 2005;93:453–8.

    Article  PubMed  Google Scholar 

  18. Sarikaya I, Güler AU. Effects of different surface treatments on the color stability of various dental porcelains. J Dent Sci. 2011;6:65–71.

    Article  Google Scholar 

  19. Ragain JC, Johnston WM. Minimum color differences for discriminating mismatch between composite and tooth color. J Esthet Restor Dent. 2001;13:41–8.

    Article  PubMed  Google Scholar 

  20. Johnston W, Kao E. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res. 1989;68:819–22.

    Article  PubMed  Google Scholar 

  21. Douglas RD, Brewer JD. Acceptability of shade differences in metal ceramic crowns. J Prosthet Dent. 1998;79:254–60.

    Article  PubMed  Google Scholar 

  22. Ishikawa-Nagai S, Yoshida A, Sakai M, Kristiansen J, Da Silva JD. Clinical evaluation of perceptibility of color differences between natural teeth and all-ceramic crowns. J Dent. 2009;37:57–63.

    Article  Google Scholar 

  23. Vichi A, Louca C, Corciolani G, Ferrari M. Color related to ceramic and zirconia restorations: a review. Dent Mater. 2011;27:97–108.

    Article  PubMed  Google Scholar 

  24. Al-Wahadni A, Glazing MMD. finishing dental porcelain: a literature review. J Can Dent Assoc. 1998;64:580–3.

    PubMed  Google Scholar 

  25. Raimondo RL, Richardson JT, Wiedner B. Polished versus autoglazed dental porcelain. J Prosthet Dent. 1990;64:553–7.

    Article  PubMed  Google Scholar 

  26. Goldstein GR, Barnhard BR, Penugonda B. Profilometer, SEM, and visual assessment of porcelain polishing methods. J Prosthet Dent. 1991;65:627–34.

    Article  PubMed  Google Scholar 

  27. Günay Y, Atay A, Ozkan Y, Akyil MS, Karayazgan B, Toksoy F. Effect of colored beverages on the color stability of feldspathic porcelain subjected to various surface treatments. Quintessence Int. 2009;40:41–8.

    Google Scholar 

  28. Kursoglu P, Motro PFK, Kazazoglu E. Correlation of surface texture with the stainability of ceramics. J Prosthet Dent. 2014;112:306–13.

    Article  PubMed  Google Scholar 

  29. Guler AU, Yilmaz F, Kulunk T, Guler E, Kurt S. Effects of different drinks on stainability of resin composite provisional restorative materials. J Prosthet Dent. 2005;94:118–24.

    Article  PubMed  Google Scholar 

  30. Gupta R, Parkash H, Shah N, Jain VA. Spectrophotometric evaluation of color changes of various tooth colored veneering materials after exposure to commonly consumed beverages. J Indian Prosthodont Soc. 2005;5:72.

    Article  Google Scholar 

  31. Samra APB, Pereira SK, Delgado LC, Borges CP. Color stability evaluation of aesthetic restorative materials. Braz Oral Res. 2008;22:205–10.

    Article  PubMed  Google Scholar 

  32. Acar O, Yılmaz B, Altıntas SH, Chandrasekaran I, Johnston WM. Color stainability of CAD/CAM and nanocomposite resin materials. J Prosthet Dent. 2016;115:71–5.

    Article  PubMed  Google Scholar 

  33. Awad D, Stawarczyk B, Liebermann A, Ilie N. Translucency of esthetic dental restorative CAD/CAM materials and composite resins with respect to thickness and surface roughness. J Prosthet Dent. 2015;113:534–40.

    Article  PubMed  Google Scholar 

  34. Baldissara P, Llukacej A, Ciocca L, Valandro FL, Scotti R. Translucency of zirconia copings made with different CAD/CAM systems. J Prosthet Dent. 2010;104:6–12.

    Article  PubMed  Google Scholar 

  35. Pop-Ciutrila IS, Dudea D, Eugenia BM, Moldovan M, Cîmpean SI, Ghinea R. Shade Correspondence, Color, and Translucency Differences between Human Dentine and a CAD/CAM Hybrid Ceramic System. J Esthet Restor Dent. 2016;28:46–55.

    Article  Google Scholar 

  36. Mainjot A, Dupont N, Oudkerk J, Dewael T, Sadoun M. From Artisanal to CAD- CAM Blocks State of the Art of Indirect Composites. J Dent Res. 2016;95:487–95.

    Article  PubMed  Google Scholar 

  37. Vasudeva G. Monomer systems for dental composites and their future: a rewiev. J Calif Dent Assoc. 2009;37:389–98.

    PubMed  Google Scholar 

  38. Paravina RD, Ontiveros JC, Powers JM. Curing-dependent changes in color and translucency parameter of composite bleach shades. J Esthet Restor Dent. 2002;14:158–66.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by 2014/52 number project by the Gaziosmanpasa University Scientific Research Projects Unit with the used materials. This study has been supported by only materials used in the study by Gaziosmanpasa University Scientific Research Projects Unit. Any financial support has not been provided for publication of the study results.

Availability of data and materials

Dr.I.S. should be contacted if someone wants to request the data or material.

Author information

Authors and Affiliations

Authors

Contributions

IS; Study conception and design, Acquisition of data, Analysis and interpretation of data,. Drafting of manuscript. KY; Study conception and design, Acquisition of data, Analysis and interpretation of data. YH; Analysis and interpretation of data, Critical revision. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Işıl Sarıkaya.

Ethics declarations

Ethics approval and consent to participate

Human subjects, human material, or human data, have not been used in this research article. So, the Declaration of Helsinki, and an ethics committee consent have not been referring provided.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sarıkaya, I., Yerliyurt, K. & Hayran, Y. Effect of surface finishing on the colour stability and translucency of dental ceramics. BMC Oral Health 18, 40 (2018). https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-018-0508-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12903-018-0508-4

Keywords