Skip to main content

Transport of COVID-19 and other highly contagious patients by helicopter and fixed-wing air ambulance: a narrative review and experience of the Swiss air rescue Rega

Abstract

Background

The current COVID-19 pandemic highlights the challenges air ambulance services are facing when transporting highly infectious patients for several hours in enclosed spaces. This overview provides an example of a standard operating procedure (SOP) for infection prevention measures in HEMS missions during the COVID-19 pandemic. Furthermore, we describe different methods used by several organizations in Europe and the experience of the Swiss air rescue organization Rega in transporting these patients.

Possible benefits of the use of small patient isolation units (PIU) are discussed, including the fact that accompanying medical personnel do not need to wear personal protective equipment (PPE) during the transport but can still maintain full access to the patient. Rega has developed and patented its own PIU. This device allows spontaneously breathing or mechanically ventilated patients to be transported in pressurized jet cabins, small helicopters and ambulance vehicles, without the need to change between transport units. This PIU is unique, as it remains air-tight even when there is a sudden loss of cabin pressure.

Conclusion

A wide variety of means are being used for the aeromedical transport of infectious patients. These involve isolating either the patient or the medical crew. One benefit of PIUs is that the means of transport can be easily changed without contaminating the surroundings and while still allowing access to the patient.

Background

During the current Coronavirus (COVID-19) pandemic, ground and air rescue, rotary-wing (HEMS) and fixed-wing (AEMS) emergency medical services are faced with unprecedented challenges. While there are several recommendations for protective measures during in-hospital emergency procedures and tracheal intubation, there is insufficient guidance regarding the prehospital setting [1]. Moreover, so far there are no published guidelines on how to safely transfer COVID-19 patients.

Unfortunately, the disease transmission risk for aeromedical crew members is higher than for in-hospital healthcare providers, largely due to information, resources and space being very limited in the prehospital setting, and aerosol-generating procedures such as airway management and ventilation being one of the main tasks. Different approaches are used to prevent transmission from patients with highly contagious infections during air transport. To address these issues we have reviewed current concepts in aeromedical transport in Europe, and we present the experience and recent recommendations of the Swiss Air Rescue (Rega) for COVID-19 and aeromedical transport.

Recommendations for HEMS missions during the COVID-19 pandemic

Every air rescue provider should develop precise SOPs for the use and handling of PPE during HEMS missions. Especially during the current pandemic, with high numbers of infected patients (and individuals with unknown COVID-19 status), strict adherence to these standards on every mission is essential. Simulation training of these special measures to prevent infection is highly recommended for every crew member, as this is known to improve adherence to the SOPs [2, 3].

Table 1 provides an example of an SOP for infection prevention measures in primary (and secondary) HEMS missions during the COVID-19 pandemic, as used by Rega.

Table 1 Sample SOP “Infection prevention measures for HEMS missions during the COVID-19 pandemic”

During the COVID-19 pandemic, Rega has not used closed suction catheters on primary missions or for transfers between hospitals (secondary transport), and their use is avoided even if they are pre-installed, due to the risk of aerosol production from mobile suction units. Furthermore, most patients with COVID-19 (without bacterial superinfection) have only minor production of bronchial secretions.

Secondary transport of COVID-19 patients

Air rescue providers use different concepts for the secondary transport of COVID-19 patients: open transport systems that allow direct patient management through the medical crew wearing PPE (e.g., FFP2/3 mask, goggles or face shield, gloves and protective gown) throughout the transport [4], or closed transport systems (so-called air transport isolator systems) that were originally developed for the fixed-wing transport of patients with other highly contagious and dangerous diseases, such as viral hemorrhagic fever.

There are two basic designs of these isolator systems: closed patient isolation units (PIU), which separate the patient from the medical crew (e.g., EpiShuttle®, EpiGuard HQ, Oslo Norway); Stretcher-Air Transport Isolators (S-ATI), and the larger Trexler Air Transport Isolator (T-ATI; Trexler Air Transport Isolator, UK, United Kingdom and the Rega PIU (Fig. 1). Alternatively, there are open systems which provide a portable isolation facility large enough for both the patient and attending medical staff wearing personal protective equipment (e.g., multi patient transport unit, the Containerized Biological Containment System, CBCS, Phoenix Arizona, USA). In the case of COVID-19, open PIUs do not offer an additional benefit.

Fig. 1
figure 1

Rega PIU AEMS

Table 2 provides an overview of current concepts used by different air rescue providers in Europe for transporting COVID-19 patients (as of April 5th, 2020; only providers with verified information are listed). Although the authors have made considerable efforts to collect information about transported COVID-19 patients and their operational backgrounds, the table is not exhaustive. Additional patients might have been transported by additional operators or in different aircraft; operational orders may have been modified by the date of publication, etc. Furthermore, not all operators provided the requested information, and there are certainly additional operators who might have transported COVID-19 patients. Nonetheless, the table provides insight into patients transported and the range of operators, as well as into the operational infection control mechanisms involved. At the moment, there is no pan-European register for reporting numbers of transported COVID-19 patients.

Table 2 Overview of transport concepts for secondary missions for COVID-19 patients

For secondary missions that often last several hours, it must be taken into account that working in full PPE during the transport of COVID-19 patients – especially in fixed-wing ambulances or helicopters – is very exhausting and physically stressful for the medical team, which may result in medical errors [3]. Furthermore, close attention must be paid to every movement, in order to avoid accidental disease transmission (e.g., by touching your own face with contaminated gloves). Therefore, for the aeromedical transport of patients with possible or confirmed COVID-19 on secondary missions (fixed-wing ambulances or long-lasting secondary HEMS missions), the use of a PIU offers substantial benefits, in spite of the higher costs and logistical requirements [5].

Closed PIUs also allow patients to be airlifted faster, as fixed-wing ambulances or helicopters do not require additional decontamination between transports (Fig. 2). Another advantage of using small PIUs is the easy transfer from an airplane to an ambulance or rescue helicopter, or vice versa. Thus, all teams involved in transporting these patients can be effectively protected, and the available FFP2/3 respirators can be reserved for use in hospitals. Both commonly used, small, closed PIUs (EpiShuttle® and Rega PIUs) offer these advantages.

Fig. 2
figure 2

Rega PIU HEMS: Loading or unloading of the patient in the PIU

However, at present the overall number of PIUs available for Rega is actually limited because they are normally manufactured in Italy (Lombardy). With regard to possible future epidemics or pandemics, to keep a minimum number of PIUs on hand for use in the case of a pandemic might be reasonable.

Setup and our experience with the Rega PIU

The Rega PIU (Fig. 3) comprises a flexible safety hull stabilized by arched wires mounted on a hard floor plate. It is maintained under negative pressure by a High Efficiency Particulate Air (HEPA) filtered ventilation system that uses aircraft power within the aircraft and battery power when outside, while the cabin pressure is maintained at a standard cabin altitude of 8000 ft. During development, it was successfully tested against infectious agents and liquid penetration using the EN 14126 test method and the EN ISO 17491-3 fixed-wing test, respectively. Altogether, PIU barrier performance proved equal to that provided by protective clothing. Its fixation system allows transportation on any commonly available patient stretcher. The PIU is designed to fit in a fixed-wing ambulance, a medium-sized helicopter, and ground-based ambulances (Fig. 4). Its dimensions are 200 cm*58 cm*63.5 cm. Power for the PIU ventilation is supplied by a rechargeable battery pack (runtime of 8 h) and a 220 V connector.

Fig. 3
figure 3

Two Rega PIUs in the fixed-wing ambulance

Fig. 4
figure 4

Rega PIU in a ground ambulance

Albrecht et al. showed in 2015 [6] that a PIU undergoing sudden loss of cabin pressure at a flight level of 30,000 ft. would lose leak tightness. Consequently, the Rega PIU features a built-in “air bag” that allows for additional air volume expansion encountered with sudden loss of cabin pressure [6]. Therefore, it is currently the only available PIU that allows patient transport in pressurized fixed-wing cabins at usual flight levels.

Plazikowski et al. compared airway management in the Rega PIU with airway management under standard protective measures [7]. The study compared intubation of mannequins using a standard laryngoscope, a video laryngoscope, or cricothyrotomy. Overall, intubation of a patient in the PIU was rated subjectively more difficult compared to standard measures (Visual Analogue Scale 76 vs. 9, p < 0.01). However, success rates in both groups were comparable. Thus, emergency airway management was shown to be achievable even inside the PIU.

Rega aeromedical transfer missions involving patients with highly contagious diseases, including COVID-19, since 2015

Fixed wing (AEMS) / Rega air ambulance jet CL605

Since 2015, Rega has successfully transferred 16 spontaneously breathing patients and two ventilated patient (COVID-19) in the PIU: one patient with high-risk Ebola virus exposure, four patients with open pulmonary tuberculosis, and 13 patients with confirmed COVID-19. All transports were well tolerated, although in some cases mild sedation was necessary.

In addition, six ventilated patients with COVID-19 were transported without the PIU. All of those patients needed hemodynamic monitoring and two were supported with noradrenaline during the transport. Flight duration ranged between 45 and 699 min.

Rotary wing (HEMS) / AW 109SP and/or H145

Since the beginning of the current pandemic in Switzerland, in March 2020, eighty-three seriously ill patients (55 men, 28 women) infected with COVID-19 were transported. The majority of patients were classified as NACA 4 or 5 (NACA 4: 30 and NACA 5: 42). Thirty-seven patients were spontaneously breathing, forty-six were intubated and ventilated predominantly in IPPV mode (37 IPPV, 3 CPPV, 6 PCV). Eighteen patients needed noradrenaline support for the transport. Flight duration ranged between 5 and 59 min.

Conclusion

For primary HEMS missions, SOPs for preventing the transmission of infections during the COVID-19 or other future pandemics need to be based on current recommendations of national medical societies/authorities, adapted to specific circumstances of HEMS missions, and trained in simulation. For secondary aeromedical transport of non-intubated or intubated COVID-19 patients in fixed-wing ambulances, or for long-lasting HEMS missions, the use of small closed PIUs may be beneficial.

Availability of data and materials

Not applicable.

Abbreviations

AEMS:

Aeroplane Emergency Medical Services

CDR:

Commander = pilot

COVID-19:

Corona virus disease 2019

CPPV:

Continuous positive pressure ventilation

FFP:

Filtering face piece

HEMS:

Helicopter Emergency Medical Services

IPPV:

Ntermittent positive pressure ventilation

NACA:

National Advisory Committee for Aeronautics

PCV:

Pressure-controlled ventilation

PIU:

Patient isolation unit

PPE:

Personal protective equipment

SOP:

Standard operating procedure

References

  1. Liew MF, Siow WT, Yau YW, See KC. Safe patient transport for COVID-19. Crit Care. 2020;24(1):94.

    Article  Google Scholar 

  2. WHO RtC-, Real-time Training for for the coronavirus disease outbreak. https://openwho.org/channels/covid-19. Accessed 4 Apr 2020. 2020.

  3. Radonovich LJ Jr, Cheng J, Shenal BV, Hodgson M, Bender BS. Respirator tolerance in health care workers. Jama. 2009;301(1):36–8.

    Article  CAS  Google Scholar 

  4. Nicol E, Mepham S, Naylor J, Mollan I, et al. Aeromedical transfer of Pastients with viral hemorrhagic fever. Emerg Infect Dis. 2019;25(1):5–13.

    Article  Google Scholar 

  5. Bannister B, Puro V, Fusco FM, Heptonstall J, Ippolito G. Framework for the design and operation of high-level isolation units: consensus of the European network of infectious diseases. Lancet Infect Dis. 2009;9(1):45–56.

    Article  Google Scholar 

  6. Albrecht R, Kunz A, Voelckel WG. Airplane transport isolators may lose leak tightness after rapid cabin decompression. Scand J Trauma Resusc Emerg Med. 2015;23:16.

    Article  Google Scholar 

  7. Plazikowski E, Greif R, Marschall J, Pedersen TH, Kleine-Brueggeney M, Albrecht R, et al. Emergency airway Management in a Simulation of highly contagious isolated patients: both isolation strategy and device type matter. Infect Control Hosp Epidemiol. 2018;39(2):145–51.

    Article  Google Scholar 

Download references

Acknowledgements

We thank our colleagues from European aeromedical transportation organizations for providing information about their transport of contagious patients. We would like to thank Jeannie Wurz, Medical Editor in the Department of Anaesthesiology and Pain Medicine, Bern, for editorial assistance.

Funding

No external funding.

Author information

Authors and Affiliations

Authors

Contributions

R.A. and U.P. developed the original idea for the manuscript and helped write it. J.K., L.T., M.E. helped write the manuscript, gathered additional data, and made important recommendations. All authors read and agreed to the final version of the manuscript.

Corresponding author

Correspondence to Roland Albrecht.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Albrecht, R., Knapp, J., Theiler, L. et al. Transport of COVID-19 and other highly contagious patients by helicopter and fixed-wing air ambulance: a narrative review and experience of the Swiss air rescue Rega. Scand J Trauma Resusc Emerg Med 28, 40 (2020). https://0-doi-org.brum.beds.ac.uk/10.1186/s13049-020-00734-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s13049-020-00734-9

Keywords