Haematological and Biochemical Reference Values for Healthy Adults in the Middle Belt of Ghana

Abstract

Background

Reference values are very important in clinical management of patients, screening participants for enrolment into clinical trials and for monitoring the onset of adverse events during these trials. The aim of this was to establish gender-specific haematological and biochemical reference values for healthy adults in the central part of Ghana.

Methods

A total of 691 adults between 18 and 59 years resident in the Kintampo North Municipality and South District in the central part of Ghana were randomly selected using the Kintampo Health and Demographic Surveillance System and enrolled in this cross-sectional survey. Out of these, 625 adults made up of 316 males and 309 females were assessed by a clinician to be healthy. Median values and nonparametric 95% reference values for 16 haematology and 22 biochemistry parameters were determined for this population based on the Clinical Laboratory and Standards Institute guidelines. Values established in this study were compared with the Caucasian values being used currently by our laboratory as reference values and also with data from other African and western countries.

Results

Reference values established include: haemoglobin 113–164 g/L for males and 88–144 g/L for females; total white blood cell count 3.4–9.2×109/L; platelet count 88–352×109/L for males and 89–403×109/L for females; alanine aminotransferase 8–54 U/L for males and 6–51 U/L for females; creatinine 56–119 µmol/L for males and 53–106 µmol/L for females. Using the haematological reference values based on the package inserts would have screened out up to 53% of potential trial participants and up to 25% of the population using the biochemical parameters.

Conclusion

We have established a panel of locally relevant reference parameters for commonly used haematological and biochemical tests. This is important as it will help in the interpretation of laboratory results both for clinical management of patients and safety monitoring during a trial.

Introduction

Locally relevant reference ranges for commonly used biochemical and haematological parameters are essential for screening and safety follow up of trial participants as well as for routine clinical management of patients. However, reference values being used in most laboratories in African countries have been obtained from the literature, reagent inserts accompanying the reagent kits or instrument manuals [1]. These values more often than not have been derived from Caucasian populations of industrialised countries and may not be applicable in most local settings. Factors such as age, gender [2], ethnicity [3] and environment including altitude and geo-chemicals [4] affect the measurements determined in different populations. Published literature has confirmed that many of the reference values obtained from the developed countries differ significantly from what pertains in most African localities [1], [5], [6], [7], [8]; thus making it necessary to establish locally relevant values. The Clinical and Laboratory Standards Institute (CLSI) [9] and the International Federation for Clinical Chemistry (IFCC) [10] recommend that each laboratory establishes its own reference values.

The Kintampo Health Research Centre (KHRC) located in Central Ghana has been undertaking Phase II/III drugs and vaccines trials since 2003 and plans soon to add Phase I trials in infectious diseases. Locally relevant biochemical and haematological reference values for the population are needed in determining eligibility of participants being enrolled into future studies and also for monitoring of the onset of any adverse events during a trial. Availability of such reference values in the locality would also assist physicians in the management of patients. This study was, thus, aimed at establishing reference values for commonly used haematological and biochemical parameters in the population within the Kintampo North Municipality and Kintampo South District.

Methods

Study Site

The study was carried out in the Kintampo North Municipality and Kintampo South District of the Brong Ahafo Region of Ghana (Figure 1 and Figure 2). The studied area is located between Latitudes 7°43′N and 8°44′N and Longitudes 1°25′W and 2°1′W. It lies within the forest-savannah transitional ecological zone and has an elevation ranging between 60 and 150 m above sea level. It is made up of a resident population of about 140,000. The Kintampo Health Research Centre maintains a Health and Demographic Surveillance System (HDSS) that records detailed demographics of all residents including pregnancies, births, deaths and migrations (in and out) at 4 monthly intervals. All the compounds have been digitized making the selection and tracing of individuals to their homes easy.

Selection of reference population

The communities and individuals who participated in this study were randomly selected from the HDSS human population using the Visual FoxPro software. Community meetings were held to explain the objectives of the study to the opinion leaders and other community members.

Those selected through the randomisation were invited to a central location where individual consenting, screening and blood collections were carried out. Inclusion into the study was based on willingness of the individual to participate in the study (demonstrated by the completion and signing/thumbprinting of the consent form and willingness to provide the samples required), general good health (as determined by a clinician's medical history and physical examination, and residence in the study area for at least 3 months. Individuals with evidence of acute or chronic respiratory, cardiovascular, gastrointestinal, hepatic or genitourinary conditions, history of blood donation/transfusion within the immediate past three months, hospitalisation within the immediate past one month, or any other findings that in the opinion of the examining clinician may compromise on the assessment of the laboratory parameters of interest in this study were excluded. Those assessed to be pregnant (either clinically or by positive urine β-HCG test) and lactating mothers were all excluded.

Laboratory analysis

Venous blood samples were collected from the antecubital fossa, dispensed into a 2 ml K3EDTA, a 5 ml SST tubes with gel and 1 ml Fluoride-EDTA for haematology, biochemistry and glucose analysis, respectively. Sample tubes were from Becton Dickinson (Plymouth, United Kingdom). Haematological analysis (complete blood count with 3-part differential) was performed using previously validated ABX Micros 60 analysers (Horiba-ABX, Montpellier, France). Calibrators and controls were obtained from the instrument manufacturer. Analysis of samples was performed within 8 hours of blood draw.

Samples for biochemical analysis were allowed to clot for at least 60 minutes, centrifuged and the serum collected. Serum was analysed within 24 hours after collection. If testing was delayed, serum was stored frozen at −80°C and subjected to a single freeze-thaw cycle at the time of analysis. The Vitalab Selectra E Clinical Chemistry analyser (Vital Scientific, The Netherlands) was used to perform the analysis. Test tubes for the clinical chemistry analysis were from Vital Scientific, The Netherlands. Reagents, calibrators and controls were from Elitech Diagnostics (Sees, France). Electrolytes (chloride, potassium and sodium) were analysed using the Humalyte Electrolyte analyser (Human Diagnostics, Germany). Reagents were from the manufacturer of the instrument.

Normal and abnormal controls were run daily. No analysis was done if controls were out of range. In addition to the internal quality assessment, the laboratory participates in external quality assessments for haematology and clinical chemistry both with the College of American Pathologists (CAP) and the United Kingdom National External Quality Assessment Scheme (UK NEQAS). The laboratory complies with the principles of Good Clinical Laboratory Practice [11], [12]. Individuals with abnormal clinical or laboratory test results were referred for appropriate care and treatment.

Between-run precision for the analytes were assessed using at least 20 measurements made on separate days using normal control samples. The mean, standard deviation (SD) and coefficient of variation (CV) were calculated for each analyte. Coefficients of variation (CVs) were compared to those quoted in the analyser manuals and reagent inserts.

Data Management and Statistical Analysis

Data were recorded on questionnaires, double-entered into a Visual FoxPro 9.0 database and verified. Data analysis was carried out using Stata 11 (Stata Corp, College Park, TX, USA). The 2.5th and 97.5th percentiles were determined non-parametrically. This was according to the CLSI/IFCC guidelines on defining, establishing and verifying reference intervals in the clinical laboratory [9]. To obtain these intervals, a minimum of 120 observations were required for each analyte within each subgroup. Outliers within each subgroup were identified using the Dixon method [9]. Briefly, the extreme values were retained in the distribution if D/R<0.33, where D is the absolute difference between the most extreme distribution and the next value and R is the Range (maximum – minimum). Reference values were determined separately for males, females and combined gender. Differences between genders were tested using the Mann-Whitney test. The values defined were compared with the recommended reference values (based on a North American population) provided in the ABX Micros 60 Haematology User Manual [13] and Elitech Diagnostics chemistry reagent inserts, respectively.

Ethical Considerations

This study was approved by Ethics Committees of the Kintampo Health Research Centre, the Noguchi Memorial Institute for Medical Research and the Ghana Health Service. Written informed consent was obtained from each participant prior to involving them in the study.

Results

A total of 691 randomly selected adults made up of 351 males and 340 females between the ages of 18 and 59 years (mean = 37 years) were screened during the survey. Out of this, 625 individuals (316 males and 309 females) with a mean age of 36 years were enrolled. Tobacco use among all males screened was 64 (9.26%) out of which 52 (8.3%) were among those enrolled. None of the females screened and/or enrolled was a smoker. Screened and enrolled males and females who take alcohol were 107 (33.75%) and 34 (10.97%) respectively. Forty-three (6.2%) of the screened population were taking prescribed medication and were excluded from the study.

Reference Values

Median and 95% reference values (2.5th–97.5th percentiles) for Haematology and Biochemistry are shown in Tables 1 and 2, respectively. Males had significantly higher haemoglobin values of 113–164 against 88–144 g/L for females (p<0.0001), haematocrit of 33.2–50.5 against 26.4–45.0% (p<0.0001) and red blood cells (RBC) of 3.79–5.96 against 3.09–5.30×1012/L (p<0.0001) compared to females. On the other hand, platelets were significantly higher in females with 89–403 against 88–352×109/L for males (p<0.0001). For the biochemical values, males had significantly higher alanine aminotransferase (ALT) of 8–54 against 6–51 U/L (p<0.0001), aspartate aminotransferase (AST) of 17–60 against 13–48 U/L (p<0.0001), alkaline phosphatase (ALP) of 101–353 against 82–293 U/L (p<0.0001), Creatine kinase (CK) of 93–786 against 58–476 U/L (p<0.0001), gamma glutamyltransferase (GGT) of 9–71 against 6–53 U/L (p<0.0001), Creatinine of 56–119 against 47–110 µmol/L (p<0.0001), Iron of 6.0–32.8 against 5.4–27.8 µmol/L (p<0.0001), and Uric acid of 126–418 against 83–381 µmol/L (p<0.0001), compared to the females. Females, however, had significantly higher Cholesterol levels of 2.1–5.6 against 1.8–5.6 mmol/L for males (p<0.0001).

The column percentage out-of range (% OOR) in Tables 3 and 4 shows the proportion of normal adults in the Kintampo area who would have been classified as having abnormal haematology and biochemistry results when compared with the recommended reference values (based on a north American population) provided in the ABX Micros 60 Haematology User Manual [13] and Elitech Diagnostics reagent inserts, respectively. Out of range values for haematology ranged between 13 and 96% with parameters such as Haemoglobin, Haematocrit, RBC, mean cell volume (MCV), mean cell haemoglobin (MCH), mean cell haemoglobin concentration (MCHC) and white blood cell (WBC) predominantly on the lower side of the comparison values. OOR values for biochemistry were high for Amylase (28% and 18%), CK (74% and 58%), lactate dehydrogenase (LDH) (37% and 28%), Protein (34% and 31%), Total Bilirubin (23% each), Urea (25% and 32%), Uric Acid (30% and 36%) and Phosphorus (23% and 24%) for males and females, respectively. Tables 5 and 6 show a comparison of haematology and biochemistry reference values established for Kintampo with values from other studies. Between-run precision for the haematology and clinical chemistry assays are presented in Tables 7 and 8, respectively. The methods used for the various clinical chemistry analytes are also shown in Table 8.

thumbnail
Table 3. Haematology out of range (OOR) values based on comparison with ABX values.

https://doi.org/10.1371/journal.pone.0036308.t003

thumbnail
Table 4. Biochemistry out of range (OOR) values based on comparison with values from Elitech reagent inserts.

https://doi.org/10.1371/journal.pone.0036308.t004

thumbnail
Table 5. Comparison of adult haematological reference values obtain from this study against others.

https://doi.org/10.1371/journal.pone.0036308.t005

thumbnail
Table 6. Comparison of adult biochemical reference values obtained from this study against others.

https://doi.org/10.1371/journal.pone.0036308.t006

thumbnail
Table 8. Methods and analytical precision for clinical chemistry assays.

https://doi.org/10.1371/journal.pone.0036308.t008

Discussion

This study aimed at establishing haematological and biochemical reference values to serve as standards for the interpretation of laboratory results during screening and follow-ups in clinical trials and routine healthcare in the Kintampo area. The results obtained from the Kintampo area demonstrated that the red blood cell parameters (haemoglobin, haematocrit and RBC counts) were lower than values set as standards on the clinical haematology machines being used for clinical trials assessments in the study area. Such variations are expected for populations in different geographical/ecological locations; the recommendations of the manufacturers for each laboratory to establish its own reference values based upon the local population [13] has been proved beneficial. Values in the manual accompanying the haematology analyzer were defined using a population in New Jersey, USA. It is of interest to document also that the values obtained from our study were on most occasions far lower than those of other western industrialized countries [14], [15]. Similar observations have been made in studies carried out in Mampong Akuapem in southern Ghana [1]; Kericho in Kenya [16]; in southern and eastern Africa [7]; in Saudi Arabia [17], Erzurum; in Turkey [18] as well as Pakistan [19]. These lower values for areas in sub-Saharan Africa have been attributed to factors such as poor nutritional status, genetic red blood cell disorders (such as sickle cell trait) or parasitic infections including schistosomiasis or malaria [7]. No differences were observed in both haemoglobin and haematocrit values obtained in this study and that of the populations of southern Ghana [1]. A similar survey in the northern part of Ghana will help inform the scientific community about how much generalization one can make using the Kintampo area study results. The haemoglobin levels were, however, higher in this survey than those obtained from other populations in Kericho, Kenya [16].

Significant gender differences were documented for the RBC parameters (haemoglobin, haematocrit and RBC), and this is consistent with an already-established knowledge that males have higher values for these parameters than females [6], [15], [18], [20], [21]. The reasons for these differences have been attributed to factors such as the influence of the androgen hormone on erythropoiesis and menstrual blood loss in females [16], [21]. The demonstration of significantly higher platelet values in females than males supports findings from previous studies [1], [15], [16]. Platelet and WBC values documented in this study were generally lower compared with the values in the instrument manual as well as values reported by Kratz et al. [14] in the US and Wakeman et al. [15] in the UK. The values from this study were however similar to those reported in southern Ghana [1] and many other African countries [21], [22], [23], [24]. The cause(s) of lower platelet counts in Africans is not known [6]; however, the lower platelet values in our studies could be due to genetic factors [25] or increased consumption of platelets as a result of malaria infection in our study areas [26].

The most commonly requested haematology parameters for screening/enrolment of participants and monitoring safety during clinical trials are haemoglobin, haematocrit, total WBC and platelet counts [27], [28], [29]. The proportion of OOR values for these four parameters ranged between 16.1% and 53%. This means based on the previous reference values used in the study area, up to 53% of potential study participants would have been declared as having abnormal results or enrolled participants would be reported as having adverse events (AEs). In the area of clinical management of patients, a patient requiring a particular treatment may be denied it whiles one who does not need treatment would end up being treated due to the use of inappropriate reference values. In other studies, the OOR values for these parameters were up to 29% [7] and 44% [20] when the locally derived values were compared with US data.

Findings of significantly higher values in males than females for the following biochemical parameters (ALT, AST, ALP, Bilirubin, CK, GGT, iron, creatinine, urea), and vice versa for uric acid is generally supported by other studies [1], [16], [20] as shown in Table 6. The urea levels were low when compared to the values from the reagent inserts of Elitech Diagnostics and the US values [14]. However the results from this study were comparable to those from other African countries [16], [20] and from Saudi nationals [17].

Biochemical tests commonly used during screening/enrollment and safety monitoring of trial participants in the Kintampo study area are ALT, AST, Bilirubin (Total and Direct), Urea and Creatinine. The proportion of OOR values for these parameters was up to 32% in our study, compared to up to 42% in Kenya [7] and up to 81% in Tanzania [20]. The concern is about the levels of disqualification from screening/enrolment into clinical trials and mis-interpretations of AEs. Using the western values, we will report laboratory AEs in essentially normal volunteers, with the potential to ruin a trial (based on AEs) where there is no problem as such. Similar findings of higher ALT and AST values have been reported in south India [30]. Although the definite cause of higher liver enzymes in our population is unknown, there is the possibility of this being due to subclinical viral infections or the levels of usage of herbal preparations as discussed in earlier publications [1]. Screening for Hepatitis viruses was not performed in this study. However, published data on prevalence of these viruses among Ghanaian blood donors is 7 to 15% for Hepatitis B virus [31], [32] and 7 to 11% for Hepatitis C virus [31]. On the use of herbal preparations, it has been estimated that the first line treatment for 60% of children with fever resulting from malaria in Ghana, Mali, Nigeria and Zambia is the use of herbal medicine at home [33].

Between-run test measures a method's overall precision as it measures the random error inherent in the method from day to day. It takes into account variable factors such as changes in reagents, operators and ambient operating conditions. Between-run precision for haemoglobin and platelets were within precision limits quoted in the analyser manual. Although the CVs for the other analytes were higher (i.e. haematocrit 2.65 against 2.47%, RBC 1.91 against 1.24% and WBC 2.64 against 1.9%), they were within the Clinical Laboratory Improvement Act (CLIA) acceptable test performance criteria [34]. These 5 parameters are presented for haematology because they are the measured analytes from which the others are derived. Majority of the clinical chemistry tests were also within the precision limits indicated by the reagent producers. The precision of all the analytes were within the CLIA acceptable performance criteria limits. This precision data supports the reliability of the reference values established by this study.

Conclusion

The reference values developed for the Kintampo study area will be of immense benefit to most clinical trials requiring monitoring of haematological and biochemical parameters and patient care in general. Compared to other references, the reference values for haemoglobin, haematocrit, red blood cell counts and urea are lower in the Kintampo study area.

Acknowledgments

The authors would like to thank the community members of the Kintampo North Municipality and South District for volunteering to participate in this study; staff of the Kintampo Health Research Centre who supported the field work including logistics acquisition, especially Drs Ruth Owusu and Stephen Apanga for clinical support, Kofi Tchum for laboratory support, Elizabeth Awini and Samuel Danso for data management and analysis; Ghana Health Service and the Noguchi Memorial Institute for Medical Research.

Author Contributions

Conceived and designed the experiments: DKD KPA KOK JO KAK SOA. Performed the experiments: DKD KK DAG. Analyzed the data: DKD SAE EM. Wrote the paper: DKD KPA KAK SOA. Data collection: DKA KK PB KOK EK. Revised and approved final version of manuscript: DKD KK DAG EK JO KOK EM SAE PB KPA KAK SOA.

References

  1. 1. Koram K, Addae M, Ocran J, Adu-Amankwah S, Rogers W, et al. (2007) Population based reference intervals for common blood haematological and biochemical parameters in the akuapem north district. Ghana Med J 41: 160–166.
  2. 2. Buchanan AM, Muro FJ, Gratz J, Crump JA, Musyoka AM, et al. (2010) Establishment of haematological and immunological reference values for healthy Tanzanian children in Kilimanjaro Region. Trop Med Int Health 15: 1011–1021.
  3. 3. Horn PS, Pesce AJ (2002) Effect of ethnicity on reference intervals. Clin Chem 48: 1802–1804.
  4. 4. El-Hazmi MAF, Warsy AS (2001) Normal reference values for the haematological parameters, red cell indices, HbA2 and Hb F from early childhood through adolescence in Saudis. Ann Saudi Med 2: 165–169.
  5. 5. Adetifa IM, Hill PC, Jeffries DJ, Jackson-Sillah D, Ibanga HB, et al. (2009) Haematological values from a Gambian cohort–possible reference range for a West African population. Int J Lab Hematol 31: 615–622.
  6. 6. Lugada ES, Mermin J, Kaharuza F, Ulvestad E, Were W, et al. (2004) Population-based hematologic and immunologic reference values for a healthy Ugandan population. Clin Diagn Lab Immunol 11: 29–34.
  7. 7. Karita E, Ketter N, Price MA, Kayitenkore K, Kaleebu P, et al. (2009) CLSI-derived hematology and biochemistry reference intervals for healthy adults in eastern and southern Africa. PLoS One 4: e4401.
  8. 8. Quinto L, Aponte JJ, Sacarlal J, Espasa M, Aide P, et al. (2006) Haematological and biochemical indices in young African children: in search of reference intervals. Trop Med Int Health 11: 1741–1748.
  9. 9. CLSI (2008) Defining, establishing, and verifying reference intervals in the clinical laboratory: approved guideline. Wayne, PA: Clinical and Laboratory Standards Institute.
  10. 10. Solberg HE (1987) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of reference values. Part 1. The concept of reference values. J Clin Chem Clin Biochem 25: 337–342.
  11. 11. Stevens W (2003) Good clinical laboratory practice (GCLP): the need for a hybrid of good laboratory practice and good clinical practice guidelines/standards for medical testing laboratories conducting clinical trials in developing countries. Qual Assur 10: 83–89.
  12. 12. Ezzelle J, Rodriguez-Chavez IR, Darden JM, Stirewalt M, Kunwar N, et al. (2008) Guidelines on good clinical laboratory practice: bridging operations between research and clinical research laboratories. J Pharm Biomed Anal 46: 18–29.
  13. 13. ABX (2003) User manual: Micros 60 OS/OT RABO42DA.
  14. 14. Kratz A, Ferraro M, Sluss PM, Lewandrowski KB (2004) Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Laboratory reference values. N Engl J Med 351: 1548–1563.
  15. 15. Wakeman L, Al-Ismail S, Benton A, Beddall A, Gibbs A, et al. (2007) Robust, routine haematology reference ranges for healthy adults. Int J Lab Hematol 29: 279–283.
  16. 16. Kibaya RS, Bautista CT, Sawe FK, Shaffer DN, Sateren WB, et al. (2008) Reference ranges for the clinical laboratory derived from a rural population in Kericho, Kenya. PLoS One 3: e3327.
  17. 17. Scott TG (1982) A pilot study of the reference values for the commoner haematological and biochemical parameters in Saudi nationals. J Clin Pathol 35: 69–73.
  18. 18. Kaya H, Kiki I, Akarsu E, Gundoddu M, Tekin SB, et al. (2000) Hematological values of healthy adult population living at moderate altitude (1869 m, Erzurum, Turkey). Turk J Hematol 17: 123–128.
  19. 19. Usman K, Syed ZA, Rao AA (2007) Reference range values of haematological parameters in healthy Pakistani adults. Pak J Physiol 3: 19–22.
  20. 20. Saathoff E, Schneider P, Kleinfeldt V, Geis S, Haule D, et al. (2008) Laboratory reference values for healthy adults from southern Tanzania. Trop Med Int Health 13: 612–625.
  21. 21. Menard D, Mandeng MJ, Tothy MB, Kelembho EK, Gresenguet G, et al. (2003) Immunohematological Reference Ranges for Adults from the Central African Republic. Clin Vaccine Immunol 10: 443–445.
  22. 22. Azikiwe AN (1984) Platelet count values in healthy Nigeria medical students in Jos. East Afr Med J 61: 482–485.
  23. 23. Gill GV, England A, Marshal C (1979) Low platelet counts in Zambians. Trans R Soc Trop Med Hyg 73: 111–112.
  24. 24. Tsegaye A, Messele T, Tilahun T, Hailu E, Sahlu T, et al. (1999) Immunohematological reference ranges for adult Ethiopians. Clin Diagn Lab Immunol 6: 410–414.
  25. 25. Bain BJ (1996) Ethnic and sex differences in the total and differential white cell count and platelet count. J Clin Pathol 49: 664–666.
  26. 26. Hoffbrand AV, Moss PAH, Pettit JE (2006) Essential haematology. MaldenOxford, Mass.: Blackwell Pub. 281 p.
  27. 27. Asante KP, Owusu R, Dosoo D, Awini E, Adjei G, et al. (2009) Adherence to Artesunate-Amodiaquine Therapy for Uncomplicated Malaria in Rural Ghana: A Randomised Trial of Supervised versus Unsupervised Drug Administration. J Trop Med 2009: 529583.
  28. 28. Owusu-Agyei S, Ansong D, Asante K, Kwarteng Owusu S, Owusu R, et al. (2009) Randomized controlled trial of RTS,S/AS02D and RTS,S/AS01E malaria candidate vaccines given according to different schedules in Ghanaian children. PLoS One 4: e7302.
  29. 29. Owusu-Agyei S, Asante KP, Owusu R, Adjuik M, Amenga-Etego S, et al. (2008) An open label, randomised trial of artesunate+amodiaquine, artesunate+chlorproguanil-dapsone and artemether-lumefantrine for the treatment of uncomplicated malaria. PLoS One 3: e2530.
  30. 30. Furruqh S, Anitha D, Venkatesh T (2004) Estimation of reference values in liver function test in health plan individuals of an urban south Indian population. Indian Journal of Clinical Biochemistry 19: 72–79.
  31. 31. Nkrumah B, Owusu M, Frempong HO, Averu P (2011) Hepatitis B and C Viral Infections among Blood Donors from Rural Ghana. Ghana Med J 45: 97–100.
  32. 32. Sarkodie F, Adarkwa M, Adu-Sarkodie Y, Candotti D, Acheampong JW, et al. (2001) Screening for viral markers in volunteer and replacement blood donors in West Africa. Vox Sang 80: 142–147.
  33. 33. Peltzer K (2009) Utilization and practice of traditional/complementary/alternative medicine (TM/CAM) in South Africa. Afr J Tradit Complement Altern Med 6: 175–185.
  34. 34. Clinical Laboratory Improvement Act (1988) Acceptable test performance criteria. Available: http://www.clinlabnavigator.com/pdf/Method-Evaluation/clia-acceptable-test-performance-criteria.pdf. Accessed 2012 Mar 22.