Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists

  • Jesús G. Pallarés,

    Affiliations University of Castilla-La Mancha, Exercise Physiology Laboratory at Toledo, Toledo, Spain, Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, Murcia, Spain

  • Ricardo Morán-Navarro,

    Affiliations University of Castilla-La Mancha, Exercise Physiology Laboratory at Toledo, Toledo, Spain, Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, Murcia, Spain

  • Juan Fernando Ortega,

    Affiliation University of Castilla-La Mancha, Exercise Physiology Laboratory at Toledo, Toledo, Spain

  • Valentín Emilio Fernández-Elías,

    Affiliation University of Castilla-La Mancha, Exercise Physiology Laboratory at Toledo, Toledo, Spain

  • Ricardo Mora-Rodriguez

    ricardo.mora@uclm.es

    Affiliation University of Castilla-La Mancha, Exercise Physiology Laboratory at Toledo, Toledo, Spain

Abstract

Purpose

The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT1 and VT2) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance.

Methods

Fourteen aerobically-trained male cyclists ( 62.1±4.6 ml·kg-1·min-1) performed two graded exercise tests (50 W warm-up followed by 25 W·min-1) to exhaustion. Blood lactate, and data were collected at every stage. Workloads at VT1 (rise in ;) and VT2 (rise in ) were compared with workloads at lactate thresholds. Several continuous tests were needed to detect the MLSS workload. Agreement and differences among tests were assessed with ANOVA, ICC and Bland-Altman. Reliability of each test was evaluated using ICC, CV and Bland-Altman plots.

Results

Workloads at lactate threshold (LT) and LT+2.0 mMol·L-1 matched the ones for VT1 and VT2, respectively (p = 0.147 and 0.539; r = 0.72 and 0.80; Bias = -13.6 and 2.8, respectively). Furthermore, workload at LT+0.5 mMol·L-1 coincided with MLSS workload (p = 0.449; r = 0.78; Bias = -4.5). Lactate threshold tests had high reliability (CV = 3.4–3.7%; r = 0.85–0.89; Bias = -2.1–3.0) except for DMAX method (CV = 10.3%; r = 0.57; Bias = 15.4). Ventilatory thresholds show high reliability (CV = 1.6%–3.5%; r = 0.90–0.96; Bias = -1.8–2.9) except for RER = 1 and V-Slope (CV = 5.0–6.4%; r = 0.79; Bias = -5.6–12.4).

Conclusions

Lactate threshold tests can be a valid and reliable alternative to ventilatory thresholds to identify the workloads at the transition from aerobic to anaerobic metabolism.

Introduction

Maximal oxygen consumption [1], heart rate deflection [2], ventilatory/lactate thresholds [3,4] and maximum lactate steady state (MLSS) [5] are physiological evaluations related to endurance performance. Although all these tests predict, to some degree, endurance performance its accuracy, reproducibility and affordability varies. For instance, while maximal oxygen consumption could account for 91% of variability in marathon running performance, the velocity at lactate threshold explained 98% of the performance variability [6]. In turn, ventilatory threshold can accurately track the subtle improvements in endurance performance that elite cyclists obtain during an entire season [4]. Amann and co-workers [7] propose that ventilation, being under the influence of central and peripheral chemoreflex, is more sensitive and responsive to muscle hydrogen ion accumulation than the measures of blood lactate. Although workload at ventilatory threshold seems the more precise predictor of cycling endurance performance, often times the preferential use of ventilatory or lactate thresholds depends on equipment availability and ease at data interpretation.

Physiological testing is not only useful to predict performance, but to design successful training programs. Endurance training geared to enhance performance is more efficient when workloads are individually prescribed relative to the aerobic-anaerobic transition workload compared to estimated workload by reference to a maximum (e.g. percentages of maximal heart rate or about maximal aerobic power) [8]. Identification of anaerobic threshold using indirect calorimetry (ventilatory threshold) during a graded exercise test is habitual in research laboratories, professional teams and high performance national centers [4]. However, reliable metabolic carts are expensive (approx. 30,000 $) and thus are a limited resource for many trainers and athletes. Evaluation of anaerobic threshold by capillary blood lactate (CBL) is cheaper and thus often chosen as an alternative method. However, the validity [7] and reliability [9,10] of aerobic-anaerobic CBL detection remains controversial.

Thus, performance assessment and training prescription is often based on blood lactate concentration changes during a graded exercise test (GXT). Some authors define “lactate threshold” as the workrate beyond which, blood lactate concentration rises above resting level [11]. Other authors sustain that the workload that elicits a blood lactate concentration 1 mMol·L-1 above resting levels is better related to endurance performance [12]. To avoid the bias of visual identification of lactate threshold, curve fitting procedures have been used such as the DMAX method [13]. Other investigators have proposed that identification of the workload that elicit a fixed lactate level of 4 mM can predict endurance performance [14]. Finding the highest workload that however does not results in increasing blood lactate concentration is the aim of the MLSS test [15]. Although blood lactate tests to predict performance proliferate, there has been few studies comparing the validity of these in comparison to ventilatory thresholds (i.e., VT1 and VT2).

Some investigations have studied the reliability of VT1, VT2 and lactate thresholds (LT) using a graded exercise testing protocol [7, 16]. However, to our knowledge, nobody has investigated the agreement and differences between blood lactate and ventilatory thresholds during the same incremental test. Thus, the purpose of this study was to assess the validity and reliability of critical workloads found using lactate thresholds or lactate levels in comparison to the more accepted ventilatory determined thresholds.

Materials and Methods

Subjects

Fourteen trained men cyclists volunteered to participate in this study (age 26.7 ± 8.2 yr, body mass 70.3 ± 4.9 kg, height 173.7 ± 4.2 cm, body fat 12.5 ± 3.0%, 62.1 ± 4.6 ml·kg·min-1, endurance training experience 10.9 ± 4.9 yr). No physical limitations or musculoskeletal injuries that could affect training were reported. Cyclist underwent a complete medical examination (including ECG) that showed all were in good health. This study was conducted during the period from January 2014 to July 2015. The study, which was conducted according to the declaration of Helsinki, was approved by the Bioethics Commission of the University of Murcia. Written informed consent was obtained from all subjects prior to participation.

Experimental Design

Following a familiarization GXT, participants rested for 48 hours to ensure adequate recovery. Participants visited the lab 5–7 times separated by 2–5 days. In the first two sessions, cyclists performed two identical GXT to establish the average power output (W) associated to 14 different aerobic-anaerobic events based on ventilatory gas exchange and CBL. Thereafter, participants visited the lab 3–5 more times to determine the workload associated with the maximal lactate steady state (MLSS). All trials were performed between 16:00 h—19:00 h to control the circadian rhythms effects [17], under similar environmental conditions (21–24°C and 45–55% relative humidity). In all trials subjects were ventilated at a wind velocity of 2.55 m·s-1 with a fan positioned 1.5 m from the subject’s chest. A training protocol was established with the objective of maintaining physical performance individualized to each cyclist for the entire investigation period (5–6 weeks), always keeping 24 hour of full recovery prior to each assessment session. This training program consisted in cycling sessions of 90 minutes every 48 hours at the individual intensity of nVT1 interspersed with efforts of 5–7 min at 90–95% intensity of VT2 each 20 min.

Maximal graded exercise tests

Participants performed all the experimental trials on the same cycle ergometer (Ergoselect 200, Ergoline, Germany). Immediately following a standardized warm-up of 10 min at 50 W, all participants performed a ramp protocol with increments of 25 W·min-1 until exhaustion. During GXT participants were monitored by standard 12 lead ECG (Quark T12, Cosmed, Italy), Oxygen consumption () and carbon dioxide production () were recorded using breath-by-breath indirect calorimetry (Quark B2, Cosmed, Italy). Familiarization GXT fulfilled three objectives: a) discard cardiac defects or diseases in any of the participants, b) to minimize the bias of progressive learning on test reliability and c) to discard any participant lower than 55.0 ml·kg-1·min-1.

Both experimental maximal GXT with 15 min warm-up divided in three 5-min steady state stages at 45%, 55%, and 65% of the peak power output (PPO), being the three intensities below the second ventilatory threshold (VT2). After 10 minutes of passive recovery in which each participant ingested 200–250 ml of water to ensure adequate hydration status, a sample of capillary blood from the finger was obtained to assess CBL (Lactate Pro, Arkray, Japan). Following, participants performed the GXT according to a modification of the protocol described by [4]. Initial workload was set at 50 W, with increments of 25 W·min-1, requiring at all times a cadence between 80–85 rpm.

Heart rate was continuously monitored (RS400, Polar, Finland), gas exchange was recorded breath by breath using indirect calorimetry and capillary blood samples were obtained and analyzed every 2 min (i.e., each 50 W increments). Each participant indicated their rate of perceived exertion every two minutes using the Borg Scale 6–20, where 6 is defined as an effort "very very light" and one 20 "Maximum, strenuous" effort [18]. Capillary blood lactate analyzer and indirect calorimetry devices were calibrated before each test. In order to avoid the local acidosis that could impair the attainment of maximum cardiorespiratory performance, and according to the subjects’ maximal PPO in the GXTPRE (i.e., 375-425W), starting at 50 W, the workload was progressively increased by 25 W·min-1 that ensure that testing duration was not excessively long (i.e., 13.5–15.0 min). This protocol also allowed collecting between 7 to 9 capillary blood samples before exhaustion to be used in the CBL data analysis.

Maximal lactate steady state test

Several 30 min constant workloads pedaling were performed to identify the highest workload (i.e. W) which elicited an increment in BLC less than 1 mMol between 10 and 30 min of exercise [5,19]. After 7 days from the second GXT, all participants performed the first MLSS trial at the individual workload associated to their respective lactate threshold (LT) determined during the GXT. Depending on the result of the first MLSS test, the workload of the second and following MLSS tests increased or decreased 0.2 W·Kg-1 (~ 15 W), until criteria was fulfilled. Between 3 and 5 tests were necessary to determine the workload (i.e. W) associated MLSS for each cyclist (Fig 1).

thumbnail
Fig 1. Example of determination of maximal lactate steady state.

https://doi.org/10.1371/journal.pone.0163389.g001

VO2max and ventilatory thresholds determinations during the GXT

VT1 was determined using the criteria of an increase in both ventilatory equivalent of oxygen () and end-tidal pressure of oxygen (PETO2) with no concomitant increase in ventilatory equivalent of carbon dioxide (). VT2 was determined using the criteria of an increase in both the and and a decrease in PETCO2 [4]. Maximal oxygen uptake (i.e., ) was defined as the highest plateau (two successive maximal readings within 0.15 L/min) reached. V-slope workload was identified in that intensity of exercise which, in a plot of the minute production of CO2 over the minute utilization of oxygen (), shows an increase in the slope above 1.0 [20, 21]. The workload associated with a respiratory exchange ratio equal to unity was defined as RER = 1.00 (Fig 2).

thumbnail
Fig 2. Example of determination of lactate threshold (LT) as well as first (VT1) and second ventilatory thresholds (VT2) in one test.

Each gas-exchange data point corresponds to a 10-s interval. , ventilatory equivalent for oxygen; , ventilatory equivalent for carbon dioxide; PETCO2, end-tidal pressure of oxygen; end-tidal pressure of carbon dioxide (PETCO2).

https://doi.org/10.1371/journal.pone.0163389.g002

Capillary blood lactate thresholds during the GXT

Lactate Threshold (LT) was determined by examining the lactate concentration-workload relationship ([Lact]blood/W) during the GXT as the highest workload not associated with a rise in lactate concentration above baseline [9]. Baseline lactate concentration was the average during the initial stages with values 0.5 mMol·L-1 above rest state. This always occurred just before the curvilinear increase in blood lactate observed at subsequent exercise intensities [4,22].

Lactate Threshold + 1.0 mM·L-1 (LT+1.0) represents the workload (W) which causes an increase of 1 mM·L-1 above baseline measurements [22]. As a novel contribution of this study, five new lactate thresholds were established following the same criterion as detailed to determine the LT+1.0 mM·L-1 (i.e. concentrations above baseline). Accordingly, the following thresholds were established: LT+0.5, LT+1.5, LT+2.0, LT+2.5, and LT+3.0 mM·L-1, carrying out an interpolation results for each of the concentrations proposed (Fig 2).

DMAX threshold was determined by plotting the lactate response to exercise intensity in a third-order polynomial regression curve. The DMAX was defined as the point on the regression curve that yields the maximal distance to the straight line formed by the two end points of the curve [13].

Onset of blood lactate accumulation (OBLA4mM) was defined as the exercise intensity (W) identified by interpolation across the 4 mM·L-1 point in the plot of [Lact]blood during incremental exercise [14]. Two independent observers detected all ventilatory and lactate thresholds following the criteria previously described. If they did not agree, the opinion of a third investigator was sought [23].

Body composition

Fat-free mass and fat mass were assessed by X-ray absorptiometry dual energy (DXA) (Hologic Discovery, Hologic Corp., Waltham, MA, USA). Participant’s height and weight were assessed in a stadiometer (Seca 202, Seca Ltd., Hamburg, Germany) and body mass index was calculated.

Statistical analysis

Standard statistical methods were used for the calculation of means, standard deviations (SD) and 95% confidence interval. The validity against the three Gold Standard methods (i.e., VT1, MLSS and VT2) was assessed using one-way repeated measures ANOVA followed by pairwise comparisons (Bonferroni’s adjustment), intraclass correlation coefficient (ICC) and Bland–Altman plots [24]. The reliability of ventilatory and lactate determinations was assessed using coefficients of variation (CV), ICC and Bland–Altman plots. The size of the correlations was evaluated as follows; r < 0.7 low; 0.7 ≤ r < 0.9 moderate and r ≥ 0.9 high [25]. Analyses were performed using GraphPad Prism 6.0 (GraphPad Software, Inc., CA, USA) and SPSS software version 19.0 (SPSS, Chicago, IL).

Results

Validity

VT1 workload (200 ± 36 W) was different to the workload for the rest of the CBL thresholds except for the LT threshold (214 ± 33 W, p = 0.147; Table 1). Accordingly, the higher correlation coefficient between VT1 and CBL was obtained with LT (r = 0.72, p < 0.05; Fig 3A). Likewise, Bland-Altman analysis (Table 1) showed the highest agreement (i.e., lower bias) for the LT method (-13.6 ± 34.3; Fig 3B). The workload at MLSS (255 ± 32 W) was different from the workload obtained with the rest of the thresholds except for RER = 1 (259 ± 36 W, p = 0.750), LT +0.5 (260 ± 36 W, p = 0.449) and DMAX (257 ± 40 W, p = 0.830) (Table 1). Meanwhile, LT+0.5—LT+3.0 and OBLA4mMol had the higher coefficient of correlation against MLSS (r > 0.78, p < 0.05 in both cases, Fig 3C). Bland-Altman analysis (Table 1 and Fig 3D) revealed less bias in LT+0.5 (-4.5 ± 23.2), DMAX (-1.8 ± 38.1) and RER = 1 (-3.8 ± 45.5).

thumbnail
Table 1. Validity results of used methods.

Comparison of workload at VT1, MLSS and VT2 against workloads.

https://doi.org/10.1371/journal.pone.0163389.t001

VT2 workload (304 ± 39 W) was similar to LT +2.0 (300 ± 37 W, p = 0.539, Fig 3), LT+2.5 (311 ± 38 W, p = 0.250) and OBLA4mM (304 ± 40 W, p = 0.965) (Table 1). The highest correlation coefficient between VT2 and CBL was with LT—LT+3.0 (r > 0.79, p < 0.05; Table 1, Fig 3E). Lactic determinations with less bias in the Bland-Altman test were LT +2.0 (2.8 ± 24.0; Fig 3F) and OBLA4mM (-1.2 ± 28.5) (S1 File).

Reliability

Intra-subject reliability (GXT I vs. GXT II) of both gold standard thresholds (VT1 and VT2) revealed low CV (3.6% and 2.1%), high ICC (r = 0.95–0.96) and low Bland-Altman bias (-2.9 ± 13.3 and -2.7 ± 11.4) suggesting high level of agreement. Similarly, the intra-subject reliability associated to lactate thresholds (LT—LT+3.0) and the OBLA4mMol were high (CV = 3.0%-3.7%; r = 0.85–0.88; p < 0.000; Bias = 1.3 ± 18.8–2.9 ± 19.0; Table 2). However, DMAX and RER = 1 had higher CV (10.3–6.4%), lower ICC (r = 0.57–0.79) and higher Bland-Altman bias (15.4 ± 42.9 and -12.4 ± 24.7) suggesting poor reliability (S1 File).

thumbnail
Table 2. Reliability of lactate and ventilatory tests.

CV, ICC and Bland-Altman results.

https://doi.org/10.1371/journal.pone.0163389.t002

Discussion

The first aim of this study was to identify during a graded exercise test (25 W·min-1), which blood lactate concentration threshold (LT, LT+0.5, LT+1, LT+1.5, LT+2.0, LT+2.5, LT+3.0 mM·L-1, DMAX or OBLA4mM) better matched the workload at ventilatory thresholds (VT1 and VT2). The ultimate goal is to provide coaches and athletes with a valid alternative test to obtain performance workloads without the need of using indirect calorimetry (less affordable technology). In addition, we tested the reliability of each of these thresholds (lactate and ventilatory) to discard methods with high variability because variability reduces our ability to detect statistical differences among tests. Finally, we compare all tests to a proxy measurement of performance (i.e., maximal lactate steady state; MLSS) to study which is a better test to predict endurance performance (i.e., more reliable and valid).

When the two GXT were compared to test reliability, we found that RER = 1, V-Slope and DMAX were the less reliable determinations with higher CV (≥ 5%), lower ICC (< 0.80) and higher Bland-Altman bias (> 5) than the rest of the indexes (Table 2). Specifically, DMAX was the least reliable of all used method, returning CV values above 10%, ICC of 0.57 and Bland-Altman bias above 15. In contrast, VO2max, VT1 and VT2 were the physiological indexes with the highest reliability (Table 2). Other authors have also found high VO2max (CV = 2% and ICC = 0.97 [26]; r = 0.92 [16]) and anaerobic threshold (VT2 r = 0.91 [27] reliability in well trained cyclist. To our knowledge, no author has compared the reliability of such an extensive battery of tests, and thus our data allow us to discourage the use RER = 1, V-Slope and DMAX when other indexes are available.

We found that the workloads at the first ventilatory threshold (i.e., VT1) could be determined by measuring the workload at which lactate start to increase above resting values (i.e., LT) since there was a high level of agreement between these two measurements (Table 1). The average difference between these two tests (VT1 vs. LT) was of only 14 watts which is half of which could be discriminated in each increment of our graded test where workloads increased 25 watts per stage. The coincidence between LT and VT1 has been known from the seminal studies of Wasserman and co-workers in the seventies [28]. That agreement between VT1 and LT has been confirmed by Lucia and co-workers using elite endurance cyclists [4] and thus our findings are not novel in this regard but rather confirmatory.

In contrast to the situation with VT1, there is no clear agreement as to which is the lactate threshold that better reflects VT2. In our experiment, VT2 statistically agreed with DMAX and RER = 1 (Table 1). However, as discussed above, reliability is low for these two indexes and thus there are not fair substitutes of VT2. Out of the reliable indexes, VT2 workload coincided with LT+2 mMol·L-1 and with the workload that elicits blood lactate concentration of 4 mMol·L-1 (i.e., OBLA 4Mm). Lastly, the workload that elicits LT+0.5 mMol·L-1 nicely agreed with the maximal workload that can be maintained without elevations in blood lactate concentration (i.e., MLSS; Table 1). Thus, coaches and athletes could, by measuring LT, LT+0.5 and LT+2 mMol·L-1 detect the workload at VT1, MLSS, VT2 and readily advice optimal performance intensity for training or endurance events.

Lactate and ventilatory thresholds are the manifestation of and underlying metabolic events where homeostasis is lost. For instance, VT1 (i.e., anaerobic threshold; [28] is the intensity at which ventilation and VCO2 increase in parallel. The increase expired CO2 is generated by the HCO3- buffering of lactic acid that reaches the blood [29]. VT2 (i.e., RCP, [28] in turn represents a work intensity at which blood lactate accumulation rises considerable and there is hyperventilation to buffer acidosis (i.e., ventilatory compensation). Thus, VT2 represents the highest metabolic rate at which the system is able to maintain an elevated but stable metabolic acidosis. Exercise above these thresholds results in accumulation of fatigue inducing metabolites [30], rapid increases in intramuscular and arterial lactic acid, hydrogen concentration [31] and changes in motor unit recruitment [32]. Several authors have reported that long-term training programs at each of these thresholds or intensity zones will produce particular and different central and peripheral adaptations [3335].

With the objective of applying our findings to training and competition, we developed Tables 3 and 4. In Table 3 the lactate indexes better associated with VT1, MLSS and VT2 just defined (i.e., proxy for LT, LT+0.5 and LT+2 mMol · L-1, respectively) are presented with their correspondent percent of HRMAX, heart rate reserve (HRR) and RPE showing the upper and lower 95% confidence interval. In this way, athletes and coaches that only have access to monitoring heart rate and/or RPE could locate the intensities of VT1, MLSS and VT2. Furthermore, we proposed several training zones based in a previous publication [35] now locating them with respect to LT, LT+0.5 and LT+2 mMol · L-1 (Fig 4). We hope that this will allow athletes and coaches to undergo training at intensities that induce different metabolic adaptations while only needing measurement of HRMAX, HRR or RPE (Table 4).

thumbnail
Fig 4. Scheme of physiological events and training zones proposed by the authors.

https://doi.org/10.1371/journal.pone.0163389.g004

thumbnail
Table 3. 95% confidence interval for each physiological event.

https://doi.org/10.1371/journal.pone.0163389.t003

thumbnail
Table 4. Personal author's approach for exercise prescription (training zones).

https://doi.org/10.1371/journal.pone.0163389.t004

Some studies in the literature present data on both ventilatory and blood lactate thresholds during GXT, although their main objective is not to compare them. Regarding VT1, Coyle et al. [22] established LT +1.0 mMol·L-1 as the lactate threshold workload that better matches the workload at VT1. This study was conducted on patients with ischemic heart disease, which could be behind the difference between our studies. Lucia and co-workers [4] detected a high agreement between VT1 and LT (321±8 W vs. 319±10 W) in elite endurance cyclists, and our data corroborates their findings in well trained cyclist. On the other hand, in an attempt to locate the VT2 workload through a CBL test, Smekal et al. [36] found that a value of 4.1±1.0 mMol·L-1 agrees with VT2 in active and healthy men and women, which coincides with our findings (Table 1). Nevertheless, Davis and co-workers [37] suggest that anaerobic thresholds have frequently been determined using blood lactate concentrations of less than 2 mMol·L-1 as a reference point. Thus, workload at VT2 could be notably underestimated when following these previous reports.

Detection of MLSS intensity is particularly important since a substantial portion of aerobic training in athletes is carried out at MLSS intensities [8,34,35,38,39,40]. Our results indicate that LT + 0.5 mMol·L-1 during a GXT is a valid predictor of MLSS workload in well trained cyclist (p = 0.449; r = 0,78; Bias = -4.5). The determination of LT + 0.5 mM·L-1 during an incremental exercise test as a proxy of MLSS will reduce testing time and the fatigue associate with the several MLSS trials required to achieve the determination. In agreement with Skinner and McLellan [41], our results showed that MLSS does not correspond to VT1 (aerobic threshold) or VT2 (anaerobic threshold) but represents an intermediate intensity between both physiological events. This finding is important since numerous authors have proposed that the workload at VT2 coincides with the one for MLSS [36,42], making it difficult for coaches and sport scientists to effectively communicate their findings and the effects produced by different training intensities. Other authors have tried to estimate the MLSS workload through CBL detected during a GXT. For example, Beneke [19] found marked differences in the workloads at LT and OBLA4mM in an incremental test with respect to the workload at MLSS in high-level rowers. Recently, Hauser et al. [43], in male trained subjects during a different GXT protocol (40W/4min), found similar evidences to those described in our work. These authors detected differences between the results of LT+1.5 mM·L-1 and MLSS (i.e., low validity values). However, contrary to our results, they found great similarities between the OBLA4mM and MLSS values. The discrepancies between studies may be related to our faster increase in workload during the GXT protocol (40 W every 4 min for Hauser et al. [43], while 75 W every 4 min, presently).

To predict performance among a group of competitors and to delimit training zones it is required to assess the workload at the aerobic and anaerobic thresholds. The most accurate way to measure this metabolic event is with the use of indirect calorimetry. Ventilatory thresholds have been shown to accurately track the improvements in endurance performance of elite [4] and well trained endurance cyclist [7]. However, indirect calorimeters are expensive and thus out of reach of many coaches and athletes. Evaluation of anaerobic threshold by CBL is cheaper and often chosen as an alternative method. However, the reliability and validity of anaerobic threshold identification by CBL is controversial. Our data support that capillary blood lactate-based tests are highly reliable and they can be a valid alternative to ventilatory thresholds to identify the workloads at the transition from aerobic to anaerobic metabolism. Furthermore, LT+0.5 mM·L-1 is an alternative test highly correlated with MLSS. These correspondences here presented between ventilatory and CBL thresholds, as well as the relationship between them and heart rate and rate of perceive exertion (Tables 3 and 4) apply to our GXT protocol (25W·min-1).

Study limitations

Any other graded (e.g., 25 W· 4 min-1) or constant workload protocols, or any other exercise modes (running, swimming or paddling) may change these relationships, and therefore the validity values reported in this work could decline.

Supporting Information

S1 File. Graded exercise test and maximal lactate steady state test results.

https://doi.org/10.1371/journal.pone.0163389.s001

(XLSX)

Acknowledgments

The authors wish to thank the subjects for their invaluable contribution to the study.

Author Contributions

  1. Conceptualization: JGP RMN RMR.
  2. Formal analysis: JGP RMN.
  3. Funding acquisition: RMR.
  4. Investigation: JGP RMN RMR.
  5. Methodology: JGP RMR.
  6. Resources: JFO VEFE RMR.
  7. Software: RMN VEFE.
  8. Supervision: JGP RMR.
  9. Validation: JFO VEFE RMR.
  10. Writing – original draft: JGP RMN RMR.
  11. Writing – review & editing: JGP RMN RMR.

References

  1. 1. Foster C (1983) VO2max and training indices as determinants of competitive running performance. J Sport Sci 1:13–22.
  2. 2. Gripp F, Lacerda ACR, Gonçalves R, Szmuchrowski L (2009) Sustained, prolonged exercise at stable heart rate defined by the deflection point identification method. J Strength Cond Res 23:632–637. pmid:19209076
  3. 3. Billat LV (1996) Use of blood lactate measurements for prediction of exercise performance and for control of training. Sports Med 22:157–175. pmid:8883213
  4. 4. Lucía A, Hoyos J, Pérez M, Chicharro JL (2000) Heart rate and performance parameters in elite cyclists: a longitudinal study. Med Sci Sports Exerc 32:1777–1782. pmid:11039652
  5. 5. Beneke R, von Duvillard SP (1996) Determination of maximal lactate steady state response in selected sports events. Med Sci Sports Exerc 28:241–246. pmid:8775160
  6. 6. Farrell PA, Wilmore JH, Coyle EF, Billing JE, Costill DL (1979) Plasma lactate accumulation and distance running performance. Med Sci Sports, 11(4), 338–44. pmid:530025
  7. 7. Amann M, Subudhi AW, Foster C (2006) Predictive validity of ventilatory and lactate thresholds for cycling time trial performance. Scand J Med Sci Spor 16:27–34.
  8. 8. García-Pallarés J, Sánchez-Medina L, Carrasco L, Díaz A, Izquierdo M (2009) Endurance and neuromuscular changes in world-class level kayakers during a periodized training cycle. Eur J Appl Physiol, 106(4), 629–638. pmid:19396614
  9. 9. Weltman A, Snead D, Stein P, Seip R, Schurrer R, Rutt R, et al (1990) Reliability and validity of a continuous incremental treadmill protocol for the determination of lactate threshold, fixed blood lactate concentrations, and VO2max. Int J Sports Med, 11(1), 26–32. pmid:2318561
  10. 10. Pfitzinger P, Freedson PS (1998) The reliability of lactate measurements during exercise. Int J Sports Med 19:349–357. pmid:9721059
  11. 11. Bishop D, Jenkins DG, McEniery M, Carey MF (2000) Relationship between plasma lactate parameters and muscle characteristics in female cyclists. Med Sci Sports Exerc 32:1088–1093. pmid:10862534
  12. 12. Coyle EF, Feltner ME, Kautz SA, Hamilton MT, Montain SJ, Baylor AM, et al (1991) Physiological and biomechanical factors associated with elite endurance cycling performance. Med Sci Sports Exerc 23:93–107. pmid:1997818
  13. 13. Cheng B, Kuipers H, Snyder AC, Keizer HA, Jeukendrup A, Hesselink M (1992). A new approach for the determination of ventilatory and lactate thresholds. Int J Sports Med, 13(7), 518–522. pmid:1459746
  14. 14. Sjödin B, Jacobs I (1981) Onset of blood lactate accumulation and marathon running performance. Int J Sports Med, 2(1), 23–26. pmid:7333732
  15. 15. Beneke R, Hütler M, Leithäuser R (2000) Maximal lactate-steady-state independent of performance. Med Sci Sports Exerc 32:1135. pmid:10862542
  16. 16. Aunola S, Rusko H (1984) Reproducibility of aerobic and anaerobic thresholds in 20–50 year old men. Eur J Appl Physiol O, 53(3), 260–266.
  17. 17. Mora-Rodríguez R, Pallarés JG, López-Gullón JM, López-Samanes Á, Fernández-Elías VE, Ortega JF (2015) Improvements on neuromuscular performance with caffeine ingestion depend on the time-of-day. J Sci Med Sport, 18(3), 338–342. pmid:24816164
  18. 18. Borg G (1998) Borg’s Perceived exertion and pain scales. Human Kinetics, Champaign, IL.
  19. 19. Beneke R (1995) Anaerobic threshold, individual anaerobic threshold, and maximal lactate steady state in rowing. Med Sci Sports Exerc 27:863–867. pmid:7658947
  20. 20. Beaver WL, Wasserman K, Whipp BJ (1986) A new method for detecting anaerobic threshold by gas exchange. J Appl Physiol 60:2020–2027. pmid:3087938
  21. 21. Gaskill SE, Ruby BC, Walker AJ, Sanchez OA, Serfass RC, Leon AS (2001) Validity and reliability of combining three methods to determine ventilatory threshold. Med Sci Sports Exerc, 33(11), 1841–1848. pmid:11689733
  22. 22. Coyle EF, Martin WH, Ehsani AA, Hagberg JM, Bloomfield SA, Sinacore DR, et al (1983). Blood lactate threshold in some well-trained ischemic heart disease patients. J Appl Physiol, 54(1), 18–23. pmid:6826403
  23. 23. Lucía A, Sánchez O, Carvajal A, Chicharro JL (1999) Analysis of the aerobic-anaerobic transition in elite cyclists during incremental exercise with the use of electromyography. Br J Sports Med 33:178–185. pmid:10378070
  24. 24. Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160. pmid:10501650
  25. 25. Vincent JW (2005) Statistics in kinesiology (3rd ed.). Champaign, IL: Human Kinetics.
  26. 26. Weston SB, Gabbett TJ (2001) Reproducibility of ventilation of thresholds in trained cyclists during ramp cycle exercise. Journal of Science and Medicine in Sport 4:357–366. pmid:11702922
  27. 27. Prud'Homme D, Bouchard C, Leblance C, Landry F, Lortie G, Boulay MR (1984) Reliability of assessments of ventilatory thresholds. J Sport Sci, 2(1), 13–24.
  28. 28. Wasserman K, Whipp BJ, Koyl SN, Beaver WL (1973) Anaerobic threshold and respiratory gas exchange during exercise. J Appl Physiol 35:236–243. pmid:4723033
  29. 29. Del Coso J, Hamouti N, Aguado-Jimenez R, Mora-Rodriguez R (2009) Respiratory compensation and blood pH regulation during variable intensity exercise in trained versus untrained subjects. Eur J Appl Physiol 107:83–93. pmid:19513741
  30. 30. Jones AM, Wilkerson DP, DiMenna F (2008) Muscle metabolic responses to exercise above and below the “critical power” assessed using 31P-MRS. Am J Physiol Regul Integr Comp Physiol 294:R585–R593. pmid:18056980
  31. 31. Cannon DT, Howe FA, Whipp BJ (2013) Muscle metabolism and activation heterogeneity by combined 31P chemical shift and T2 imaging, and pulmonary O2 uptake during incremental knee-extensor exercise. J Appl Physiol 115:839–849. pmid:23813534
  32. 32. Copp SW, Hirai DM, Musch TI, Poole DC (2010) Critical speed in the rat: implications for hindlimb muscle blood flow distribution and fibre recruitment. J Physiol (Lond) 588:5077–5087.
  33. 33. Esteve-Lanao J, Foster C, Seiler S, Lucia A (2007) Impact of training intensity distribution on performance in endurance athletes. The J Strength Cond Res, 21(3), 943–949. pmid:17685689
  34. 34. García-Pallarés J, Sánchez-Medina L, Pérez CE, Izquierdo-Gabarren M, Izquierdo M (2010a) Physiological effects of tapering and detraining in world-class kayakers. Med Sci Sports Exerc, 42(6), 1209.
  35. 35. Pallarés JG, Morán-Navarro R (2012) Methodological approach to the cardiorespiratory endurance training. J Sport Health Res 4:109–19.
  36. 36. Smekal G, von Duvillard SP, Pokan R, Hofmann P, Braun WA, Arciero PJ, et al (2012) Blood lactate concentration at the maximal lactate steady state is not dependent on endurance capacity in healthy recreationally trained individuals. Eur J Appl Physiol, 112(8), 3079–3086. pmid:22194004
  37. 37. Davis JA, Vodak P, Wilmore JH, Vodak J, Kurtz P (1976) Anaerobic threshold and maximal aerobic power for three modes of exercise. J Appl Physiol, 41(4), 544–550. pmid:985399
  38. 38. Izquierdo-Gabarren M, de Txabarri Expósito RG, Pallarés JG, Sánchez-Medina L (2010) Concurrent Endurance and Strength Training Not to Failure Optimizes Performance Gains. Med Sci Sports Exerc, 42(6), 1191–1199. pmid:19997025
  39. 39. García-Pallarés J, García-Fernández M, Sánchez-Medina L, Izquierdo M (2010b) Performance changes in world-class kayakers following two different training periodization models. Eur J Appl Physiol, 110:99–107.
  40. 40. Rønnestad BR, Ellefsen S, Nygaard H, Zacharoff EE, Vikmoen O, Hansen J, et al (2014). Effects of 12 weeks of block periodization on performance and performance indices in well-trained cyclists. Scand J Med Sci Spor, 24(2), 327–335.
  41. 41. Skinner JS, McLellan TH (1980) The transition from aerobic to anaerobic metabolism. Res Q Exerc Sport 51:234–248. pmid:7394286
  42. 42. Chicharro JL, Campos DV, Cancino CJ (2013) Fisiología del Entrenamiento Aeróbico: Una vision integrada. Médica Panamericana: Madrid.
  43. 43. Hauser T, Adam J, Schulz H (2014) Comparison of selected lactate threshold parameters with maximal lactate steady state in cycling. Int J Sports Med 35:517–521. pmid:24227122