OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

Torque; Orthodontic brackets; Cuspid


Are torque values of preadjusted brackets precise?

Alessandra Motta StrevaI; Flávio Augusto Cotrim-FerreiraII; Daniela Gamba GaribIII; Paulo Eduardo Guedes CarvalhoII

IDDS, MSc, Visiting Professor, Department of Orthodontics, Dental School, University of São Paulo, São Paulo, SP, Brazil

IIDDS, MSc, PhD, Professor, Department of Orthodontics, Dental School, University of São Paulo, São Paulo, SP, Brazil

IIIDDS, MSc, PhD, Assistant Professor, Department of Pediatric Dentistry, Orthodontics and Community Health, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil

Corresponding address Corresponding address: Dr. Alessandra Motta Streva Rua 40, nº20 - sala 517 Shopping 33 - Torre I - Vila Santa Cecília Volta Redonda, RJ - Brasil - 27260-200 Phone: +55-24-3342-4227 e-mail: amstreva@yahoo.com.br

ABSTRACT

OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands.

MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription.

RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands.

CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

Key words: Torque. Orthodontic brackets. Cuspid.

INTRODUCTION

The completely programmed bracket system, created by Andrews1 (1989), was designed with the objective of using arches without bends. However, in spite of incorporating ideal torque characteristics in the structure of such brackets, in some cases it is necessary to apply additional or individual torques on some teeth. This would occur due to several factors10,27: mechanical side-effects25, morphological differences in the buccal faces of teeth4,6,9,21,22,26, changes in the position of the brackets2,16,22,29, different methods of bracket manufacturing12,30 and orthodontic wires24, the play between the wire and the bracket slot3,4,7,16,24,25, variations in the bracket designs8, properties of the materials constituting the brackets7,8,11,13,23 and wires24 and differences between the value of the torque informed by the manufacturer and the real value of the torque of the brackets10.

The MBT system created by McLaughlin, Bennett and Trevisi17,18 (1989;2002) modified the torque on the brackets of incisors, molars and mandibular premolars, so that the clinical goals could be attained with the minimum insertion of bends in the wires, considering the play between the wire and the bracket slot. As regards the canines, brackets with three torque options were made available to professionals. For the maxillary canines, there are two types of brackets, which provide three types of torque: -7º, 0º e +7º and for the mandibular canines, also two types of brackets, providing three options of torque: -6º, 0º and +6º.

The aim of this study was to verify the torque precision of MBT brackets using the canine brackets as the representative sample of six commercial brands. The canine brackets were selected due to the importance of the appropriate positioning of those teeth at the end of the orthodontic treatment28.

MATERIAL AND METHODS

A sample of 240 metal brackets with 0.022"x0.028" slot of MBT prescription was selected (120 maxillary canine brackets with -7º of torque, and 120 mandibular canine brackets with -6º of torque). Six groups were selected, each one composed by 20 brackets of each of the brands commercially available in Brazil: Kirium Line (lot 3420; Abzil, São José do Rio Preto, SP, Brazil); Mini Master Series (maxillary canines lot 1301 and mandibular canines lot 0311; American Orthodontics, Sheboygan, WI, USA); Morelli MBT (maxillary canines lot 695388 and mandibular canines lot 706230; Morelli, Sorocaba, SP, Brazil); Gemini (lot D7120; 3M Unitek, Monrovia, CA, USA), Elite OPTI-MIM MBT (lots 541311 and 541581 of maxillary canines and 541311 and 541587 of mandibular canines; Ortho Organizers, Carlsbad, CA, USA) and Nu-Edge (lot 3014MLH series 6.749.426; TP Orthodontics, La Porte, IN, USA).

The brackets were placed on acrylic plates that served as templates. Holes were made in these plates (7 mm in diameter by 4 mm deep) and lines were also demarcated to guide positioning of the brackets. To fix the brackets, the holes were filled with starch based modeling clay so that half of the bracket, in profile, would be inserted while the other half would be exposed for the assessment (Figure 1).


After insertion, the brackets were adjusted with a segment of 0.019"x0.025" stainless steel wire. This adjustment allowed the proximal profile of the bracket to be parallel to the template base and perpendicular to the optic visor of the microscope. A microscope (Jenalumar; Carl Zeiss, Jena, Thuringia, Germany) was used, coupled to a computer with a Charge Coupled Device (CCD) camera (KP-M1; Hitachi Denshi, Tokyo, Honshk, Japan) and image acquisition board (DT 55 fram grabber; Data Translation, Prague, Czech Republic). The images obtained by the microscope were analyzed in the Global Lab Image software (Data Translation) by a laboratorial technician instructed by the authors. When it was not possible to visualize the images adequately, they were submitted to one of the software filters.

The torque was measured in the images by means of demarcating reference points and lines. Two points were demarcated at the base of the brackets (Figure 2): point B1 (cervical extremity of the bracket base) and point B2 (occlusal extremity). Two points were also demarcated on the slots, at the vertex of the angle between the slot floor and the internal face of the wings, denominated C1 and C2 (Figure 3). If the vertex in question was not clear, due to poor finish of the slot, this point would be defined at the intersection of the angle formed between the line tangential to the internal face of the wing and the line tangential to the floor of the slot. Thus, the two base points defined Line B. The floor of the bracket slot, region that receives the orthodontic wire, and therefore, defines the vestibular-lingual inclination (torque) of the teeth in the pre-adjusted techniques, was defined by Line C.



The real torque was then defined by the angle formed between the bracket base (Line B) and the bracket slot floor (Line C). The measurements were performed in the same software used to obtain the images, with a precision of 0.01 degree.

The Mann-Whitney test was applied to compare mean torque values of each group individually with the prescribed torque value. Mann-Whitney test with Bonferroni correction was used to compare the bracket brands. The casual and systematic error was calculated with Dahlberg formula5 and Wilcoxon test, respectively, repeating the measurements of 18 brackets (3 brackets of each brand) for 3 times with 1-month interval. The results were considered at a significance level of 5%. The statistics was performed in the R software version 2.8.2 (R Foundation for Statistical Computing, available from http://www.r-project.org, Vienna, Bundesland Wien, Austria).

RESULTS

Method error

The results showed no significant systematic error between measurements (Tables 1 and 2). The casual error was less than 1º.

Comparison between torque values and established values of MBT brackets

The Morelli brand presented statistically significant differences in comparison to the prescription for the maxillary canine brackets (Table 3). For the mandibular canines, American Orthodontics and Ortho Organizers brackets presented statistically significant differences in comparison to the prescription (Table 4).

Intergroup comparison

There was a significant difference between Morelli brand and all other brands of the maxillary canine brackets (Table 3). There was no significant difference between the brands for the measurements of mandibular canine brackets (Table 4).

DISCUSSION

The preadjusted appliance was a great development in orthodontic mechanics. However, preadjustment of brackets to provide torque would be influenced by many factors and among them would be the precision of manufacture by the industry10,12,30. The real value of the torque of the brackets should be in accordance with the nominal values informed by the manufacturers10. It is important to highlight that there is a lack of studies in the literature analyzing preadjusted bracket precision. Thus, the goal of this study was to perform this verification, by measuring a sample of brackets of various commercial brands. The number of brackets was established by indication of a statistic, so that the number of repetitions would allow for greater reliability of the mathematical tests and would contribute effectively with precise information to orthodontists and manufacturers.

With regard to the methodology, various possibilities were investigated. Some authors that studied orthodontic materials developed mechanical devices to conduct their researches8,19,20. Others used computerized systems7 or graphic computation systems (CAD)14. Nevertheless, optical microscopy was frequently involved3,6,15,24,30. In view of this, to measure the torque of the brackets, the precision of the microscope was used in conjunction with digitization and image amplification technology. Thus, there would be precision added to visualization.

For being small parts, orthodontic brackets would be difficult to be handled by the operator. Thus, various templates were tested to handle the brackets, until one of them was as close as possible to the ideal. In principle, the brackets were immersed, in profile, in acrylic resin, but this material did not allow the brackets to be precisely adjusted. Furthermore, some brackets presented better finishing on one proximal surface than on the other, and if they were permanently fixed, it would limit observation to only one of its proximal faces. In view of this, acrylic plates with orifices filled with modeling clay were chosen as the template. Modeling clay was chosen as the method of fixation because of presenting an adequate consistency and less variation to thermal stimuli. The brackets were inserted in this template in profile, and adjusted so that the proximal surface would be parallel to the template base. Thus, the microscope would capture the image correctly. The real torque was then defined by the angle formed between the bracket base (Line B) and the bracket slot floor (Line C). The determination of the lines B and C was established by the current manufacture of brackets, which uses computer graphics (CAD) and computer systems (CAM)18. Table 3 shows the comparison between the torque values found and the MBT prescription values. Regarding the maxillary canines, it was found that Morelli brand presented statistically significant difference in relation to the expected torque value of -7º. For the mandibular canines (Table 4), it was found that American Orthodontics and Ortho Organizer brands presented statistically significant difference in relation to the expected torque value of -6º, but with good means, in addition to low amplitudes, and therefore showed manufacturing standardization.

The comparison among the six commercial brands is shown in Tables 3 and 4. Statistically significant differences were found only for the brackets of maxillary canines. In Tables 3 and 4, for the maxillary canines, Mann-Whitney test with Bonferroni correction shows that the Morelli brand differed significantly from the other brands.

By the careful choice of material for this research, and by means of a methodology that allowed excellent visualization and measurement of the angles of torque, it was found that there is still a great deal to improve in the manufacture of these accessories. Few brands met the desired level of standardization. If the brackets do not present a high level of precision, there would be no reason for the orthodontist to use brackets with pre-adjustments in daily clinic. It is obvious that a good professional will know how to make additional bends in the wires, when they are required to improve the tooth positioning. However, Lawrence Andrews1 (1989) and Mc Laughlin, Bennett and Trevisi18 (2002) conducted studies to establish angles in the brackets in order to modernize and optimize the day-to-day clinic. Therefore, bends in the wires could be minimized if good materials were available to clinicians. It is believed that this study may warn orthodontists, and thus provide stimulus for improvements in the industrial sector. It is also hoped that further research involving orthodontic materials are conducted so that this consciousness raising becomes accentuated.

CONCLUSION

Based on the results of this study and in accordance with the sample and the methodology used, it may be concluded that in general, the mean torque values for the brackets were found to be within the values prescribed by the MBT technique, except for the Morelli brand for the maxillary canine brackets. The American Orthodontics and Ortho Organizers presented significant differences for the mandibular canine brackets. The Morelli brand presented significant differences from all the other brands regarding the torques found in the maxillary canine brackets.

Received: May 24, 2009

Modification: July 28, 2009

Accepted: February 16, 2010

  • 1- Andrews LF. Straight wire - the concept and the appliance. San Diego: L.A. Wells; 1989. 407 p.
  • 2- Balut N, Klapper L, Sandrik J, Bowman D Variations in bracket placement in the preadjusted orthodontic appliance. Am J Orthod Dentofacial Orthop. 1992;102:62-7.
  • 3- Cash AC, Good SA, Curtis RV, McDonald F. An evaluation of slot size in orthodontic brackets - are standards as expected? Angle Orthod. 2004;74:450-3.
  • 4- Creekmore TD, Kunik RL. Straight wire: the next generation. Am J Orthod Dentofacial Orthop. 1993;104:8-20.
  • 5- Dahlberg G. Statistical methods for medical and biological students. New York: Interscience; London: George Aleen & Unwin;1940.
  • 6- Dellinger EL. A scientific assessment of the straight-wire appliance. Am J Orthod. 1978;73:290-9.
  • 7- Fischer-Brandies H, Orthuber W, Es-Souni M, Meyer S. Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters. J Orofac Orthop. 2000;61:258-65.
  • 8- Flores DA, Choi LK, Caruso JM, Tomlinson JL, Scott GE, Jeiroudi MT. Deformation of metal brackets: a comparative study. Angle Orthod. 1994;64:283-90.
  • 9- Germane N, Bentley B, Isaacson RJ, Revere JH Jr. The morphology of canines in relation to preadjusted appliances. Angle Orthod. 1990;60:49-54.
  • 10- Gioka C, Eliades T. Materials-induced variation in the torque expression of preadjusted appliances. Am J Orthod Dentofacial Orthop. 2004;125:323-8.
  • 11- Gmyrek H, Bourauel C, Richter G, Harzer W. Torque capacity of metal and plastic brackets with reference to materials, application, technology and biomechanics. J Orofac Orthop. 2002;63:113-28.
  • 12- Graber TM. Orthodontics, current principles and techniques. St Louis: Mosby; 1985. 915 p.
  • 13- Harzer W, Bourauel C, Gmyrek H. Torque capacity of metal and polycarbonate brackets with and without a metal slot. Eur J Orthod. 2004;26:435-41.
  • 14- Kang B, Baek S, Mah J, Yang WS. Three-dimensional relationship the critical contact angle and the torque angle. Am J Orthod Dentofacial Orthop. 2003;123:64-73.
  • 15- Kusy RP, Whitley JQ. Assessment of second-order clearances between orthodontics archwires and bracket slots via the critical contact angle for binding. Angle Orthod. 1999;69:71-80.
  • 16- McLaughlin RP, Bennett JC. Bracket placement with the preadjusted appliance. J Clin Orthod. 1995;29:302-11.
  • 17- McLaughlin RP, Bennett JC. The transition from standard edgewise to preadjusted appliance systems. J Clin Orthod. 1989;23:142-53.
  • 18- McLaughlin RP, Bennett JC, Trevisi HJ. Mecânica sistematizada de tratamento ortodôntico. 1Ş ed. São Paulo: Artes Médicas; 2002. 324 p.
  • 19- Meling TR, Odegaard J. The effect of second-order couple on the application of torque. Am J Orthod Dentofacial Orthop. 1998;113(3):256-62.
  • 20- Meling TR, Odegaard J, Seqner D. On bracket slot height: a methodologic study. Am J Orthod Dentofacial Orthop. 1998;113:387-93.
  • 21- Miethke RR. Third order tooth movements with straight wire appliances. Influence of vestibular tooth crown morphology in the vertical plane. J Orofac Orthop. 1997;58:186-97.
  • 22- Miethke RR, Melsen B. Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances. Am J Orthod Dentofacial Orthop. 1999;116:329-35.
  • 23- Sadat-Khonsari R, Moshtaghy A, Schlegel V, Kahl-Nieke B, Möller M, Bauss O. Torque deformation characteristics of plastic brackets: a comparative study. J Orofac Orthop. 2004;65:26-33.
  • 24- Sebanc J, Brantley WA, Pincsak JJ, Conover JP. Variability of effective root torque as a function of edge bevel on orthodontic arch wires. Am J Orthod. 1984;86:43-51.
  • 25- Siatkowski R E. Loss of anterior torque control due to variations in bracket slot and archwire dimensions. J Clin Orthod. 1999;33:508-10.
  • 26- Van Loenen M, Degrieck J, De Pauw G, Dermaut L. Anterior tooth morphology and its effect on torque. Eur J Orthod. 2005;27:258-62.
  • 27- Kapur-Wadhwa R. Physical and mechanical properties affecting torque control. J Clin Orthod. 2004;38:335-40.
  • 28- Zachrisson BU. Buccal uprighting of canines and premolars for improved smile esthetics and stability. World J Orthod. 2006;7:406-12
  • 29- Zanelato RC, Grossi AT, Mandetta S, Scanavini MA. Torque individualization for cuspids when the preadjusted appliance is used. Rev Clin Ortodon Dental Press. 2004;3:39-55.
  • 30- Zinelis S, Annousaki O, Eliades T, Makou M. Elemental composition of brazing alloys in metallic orthodontic brackets. Angle Orthod. 2004;74:394-9.
  • Corresponding address:
    Dr. Alessandra Motta Streva
    Rua 40, nº20 - sala 517
    Shopping 33 - Torre I - Vila Santa Cecília
    Volta Redonda, RJ - Brasil - 27260-200
    Phone: +55-24-3342-4227
    e-mail:
  • Publication Dates

    • Publication in this collection
      27 May 2011
    • Date of issue
      Aug 2011

    History

    • Accepted
      16 Feb 2010
    • Reviewed
      28 June 2009
    • Received
      24 May 2009