Cardiac Resynchronization Therapy and QRS Duration: Systematic Review, Meta-analysis, and Meta-regression

Si-Hyuck Kang,1,* Il-Young Oh,1,* Do-Yoon Kang,2 Myung-Jin Cha,2 Youngjin Cho,2 Eue-Keun Choi,2 Seokyung Hahn,3 and Seil Oh2
    • 1Department of Internal Medicine, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam, Korea.
    • 2Department of Internal Medicine, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, Korea.
    • 3Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Korea.
Received May 30, 2014; Accepted September 04, 2014.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Cardiac resynchronization therapy (CRT) has been shown to reduce the risk of death and hospitalization in patients with advanced heart failure with left ventricular dysfunction. However, controversy remains regarding who would most benefit from CRT. We performed a meta-analysis, and meta-regression in an attempt to identify factors that determine the outcome after CRT. A total of 23 trials comprising 10,103 patients were selected for this meta-analysis. Our analysis revealed that CRT significantly reduced the risk of all-cause mortality and hospitalization for heart failure compared to control treatment. The odds ratio (OR) of all-cause death had a linear relationship with mean QRS duration (P=0.009). The benefit in survival was confined to patients with a QRS duration ≥145 ms (OR, 0.86; 95% CI, 0.74-0.99), while no benefit was shown among patients with a QRS duration of 130 ms (OR, 1.00; 95% CI, 0.80-1.25) or less. Hospitalization for heart failure was shown to be significantly reduced in patients with a QRS duration ≥127 ms (OR, 0.77; 95% CI, 0.60-0.98). This meta-regression analysis implies that patients with a QRS duration ≥150 ms would most benefit from CRT, and in those with a QRS duration <130 ms CRT implantation may be potentially harmful.

Graphical Abstract

Keywords
Cardiac Resynchronization Therapy; Heart Failure; Meta-Analysis

INTRODUCTION

Heart failure is a leading cause of death in developed countries (1). Cardiac resynchronization therapy (CRT) with multisite ventricular pacing was first conceived (2) based on the finding that approximately one third of patients with advanced heart failure (HF) have prolonged ventricular conduction (3). Multiple large-scale clinical trials have shown that CRT modifies ventricular electromechanical delay, induces improvements in ventricular structure and function (4), leads to better exercise tolerance and quality of life (5, 6), and reduces mortality and hospitalization rates (7, 8).

These trial results led to the acceptance of CRT into current clinical practice guidelines (9, 10). However, there are still some controversies on specific indications for CRT in patients with HF. These disagreements mainly stem from questions of who would most and least benefit from CRT (11, 12, 13). The most debated issues include optimal QRS duration and morphology, etiology (ischemic or not), and baseline functional capacity. Recent trials, which sought to expand the indication for CRT, showed variable and conflicting results (14, 15, 16, 17, 18).

Given the broad spectrum of patient groups studied in recent trials, we hypothesized that by using meta-regression analysis more knowledge could be obtained on the factors determining the benefit of CRT. Meta-regression is an analysis tool used to examine the relationship between moderating variables and treatment effect using regression-based techniques. In this study, we conducted a comprehensive systematic review, meta-analysis, and meta-regression of data from contemporary randomized controlled trials (RCT) to determine which factors may determine the outcome of CRT.

MATERIALS AND METHODS

Eligibility criteria

We included all RCTs that compared CRT with medical treatment or implantable cardioverter-defibrillator (ICD) alone. We included RCTs that 1) enrolled patients with systolic heart failure with a left ventricular ejection fraction (LVEF) ≤40%, 2) compared CRT with control treatment, 3) studied mainly patients with sinus rhythm, and 4) reported data on clinical events such as death and hospitalization for heart failure. We excluded trials that 1) exclusively enrolled patients with atrial fibrillation, 2) compared CRT with left ventricular (LV) pacing only as the control arm, 3) compared different types of programming (such as simultaneous versus sequential biventricular pacing), and 4) compared different methods of procedure (such as transvenous versus epicardial LV lead placement or triple site versus double site pacing). No restrictions were imposed on the mode of treatment in control groups, etiology of HF, study period, sample size, or publication status.

Data sources and searches

We performed an electronic search of the PubMed, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) from the inception of each database to October 2013. The electronic search strategy was complemented by a manual review of the reference lists of included articles. References of recent reviews, editorials, and meta-analyses were also examined. One investigator performed the screening of titles and abstracts, identified duplicates, reviewed full articles, and determined their eligibility. This work was subsequently cross-checked by a second reviewer. Disagreement between reviewers was resolved by discussion. The most updated data for each study were searched manually, and chosen for abstraction. Data extraction was independently done by two reviewers and checked by a third reviewer.

Risk of bias assessment

The quality of eligible RCTs was assessed using the Cochrane Collaboration's tool for the risk of bias (19). Both the manuscript and protocol, if available (published or online), were reviewed for relevant information. Risk of bias was assessed by one reviewer and cross-checked by a second reviewer.

Study outcomes and definitions

Independent variables in this study were hard clinical outcomes. The primary study endpoint was all-cause mortality, while the secondary endpoint was hospitalization for heart failure.

Data synthesis and analysis

Odds ratios (OR) with 95% confidence intervals (CI) were presented as a summary statistic. We calculated pooled ORs with the use of the random effects model postulated by DerSimonian and Laird (20). Statistical heterogeneity was assessed with Cochran Q via a chi-square test and was quantified with the I2 test (21). Publication bias was assessed by funnel plot asymmetry and Egger's test.

Exploratory meta-regressions were performed to assess heterogeneous study effects. Covariates that were tested include: 1) QRS duration, 2) QRS morphology, 3) ischemic origin, 4) baseline New York Heart Association (NYHA) functional class, 5) baseline LVEF, 6) LV end-diastolic dimension (LVEDD), and 7) LV end-diastolic volume (LVEDV). QRS morphology was quantified as the proportion of left bundle branch block (LBBB) documented in each trial, excluding those which exclusively enrolled HF patients with a narrow QRS duration. Analysis for NYHA classification was done with the proportion of patients with NYHA functional class III or IV as a covariate. We performed meta-regression analyses using two different statistical models to estimate residual between-trial variance: 1) a random effects model with a restricted maximum likelihood (REML) estimate (22), and 2) a Bayesian random effects model (23).

Subgroup analysis was planned with stratification according to 1) treatment modality of the control groups (ICD vs. medical therapy), 2) NYHA function class (predominantly class I/II vs. III/IV), or 3) follow-up duration (<1 vs. ≥1 yr). Interaction was tested with the use of a mixed-effects meta-regression model (REML method). Sensitivity analysis was done on studies with a low risk of bias. Excluded in the sensitivity analysis were studies with >1 entry assigned to be at high or unclear risk of bias assessed with the Cochrane Collaboration's tool (except for the domains of blinding on patient and physician).

Statistical analysis

Statistical analysis was performed using the "metafor" and "meta-commands" packages in R programming, version 3.0.2 (The R Foundation for Statistical Computing, Vienna, Austria). Results were considered statistically significant if the 2-sided P<0.05. The Bayesian random effects model was constructed with WinBUGS v.1.4.3 (MRC Biostatistics Unit, Cambridge, UK) (24). Odds ratios (OR) with 95% credible intervals (CrIs) are presented as summary statistics, and results for which the CrIs of the ORs did not include one were considered significant. Non-informative prior distributions were selected so as to allow the data to dominate the final results. We ran Markov chain Monte Carlo samplers in WinBUGS, running three chains with different starting values. A burn-in phase of 20,000 iterations was followed by 50,000 updates, where the number of burn-in iterations was chosen according to the Brooks-Gelman-Rubin method for convergence checks (25).

RESULTS

Study selection

Fig. 1 describes the flow of systematic literature review according the Statement of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Among 785 potentially relevant items, 23 trials comprising 10,103 patients were finally selected for this meta-analysis.

Fig. 1
Flow diagram of systematic review. The flow diagram depicts the detailed process of systematic literature review according the statement of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. RCT, randomized controlled trial.

Systematic review and study characteristics

Table 1 briefly describes the key features of the included trials. While many of the studies compared cardiac resynchronization therapy defibrillation (CRT-D) with ICD, some compared cardiac resynchronization therapy pacemaker (CRT-P) with medical therapy. One study enrolled patients undergoing coronary artery bypass graft (CABG) surgery and randomized to CRT-P with CABG or CABG alone (26). Another study compared CRT-D plus bone marrow mononuclear cell transplantation (BMMC) to BMMC alone (27). Two trials had not been published in peer-reviewed journals, so data were extracted from online source (28, 29).

Mean age in the individual studies ranged from 58 to 72 yr, and the proportion of males ranged from 63% to 96%. Mean duration of the QRS complex was highly variable across trials and ranged from 95 ms to 174 ms. Meanwhile, LVEF was uniformly low (21% to 30%). Estimated median duration of follow-up was 14.1 months.

Risk of bias within studies

The risk of bias of each trial was assessed with the Cochrane Collaboration's tool and is summarized in Fig. 2. All of the included studies were described as randomized trials. Allocation concealment was appropriately described in 12 trials, while clinical outcomes were adjudicated under proper blinding in 16 out of the 23 trials. Double blinding was done in 14 trials, while two trials blinded only participating patients but not treating physicians.

Fig. 2
Risk of bias assessment. Risk of bias of each included trial was assessed with the Cochrane Collaboration's tool. This 'risk of bias' summary presents all of the judgments in a cross-tabulation of study by entry. Green represents 'Yes (low risk of bias)'; yellow, 'Unclear'; red, 'No (high risk of bias)'.

All-cause mortality

Pooling of the 23 trials with the random-effects model showed a significant benefit of CRT over control treatment in terms of overall survival (OR, 0.82; 95% confidence intervals [CI], 0.68-0.98; P=0.027) (Fig. 3A). There was no significant publication bias (P=0.150 by Egger's test). The effects of CRT varied across trials with small to moderate heterogeneity (I2=25%, P=0.146). Meta-regression analyses were performed with the aim to explore factors explaining the heterogeneity. As shown in Fig. 3B, we found a significant linear association between the benefit of CRT and the length of the QRS duration [log OR=-0.01×(QRS duration)+1.34; P=0.009]. The model incorporating QRS duration as a covariate yielded no residual heterogeneity (I2=0%, P=0.367). There was no effect of CRT in patient with a QRS duration of 130 ms (OR, 1.00; 95% CI, 0.80-1.25). The benefit of CRT was more apparent as QRS lengthened and was statistically significant at a QRS duration ≥145 ms (OR, 0.86; 95% CI, 0.74-0.99). The estimated OR derived from the random-effects meta-regression model was 0.81 (95% CI, 0.72-0.93) for 150 ms. With a QRS duration <130 ms, the model suggested a potential harm with CRT without statistical significance: for example the estimated ORs at a QRS duration of 120 ms was 1.11 (95% CI, 0.83-1.49). The relationship was not significant for any other study variables including QRS morphology, ischemic origin, NYHA functional class, LVEF, LVEDD, and LVEDV (Table 2).

Fig. 3
Meta-analysis and meta-regression for all-cause mortality. (A) Forest plot with odds ratios (OR) for all-cause death after cardiac resynchronization therapy (CRT) compared to control treatment for individual trials and the pooled population. The squares and the horizontal lines indicate the ORs and the 95% confidence intervals (CI) for each included trial. The size of each square is proportional to the statistical weight of a trial in the meta-analysis. A diamond indicates the effect estimate derived from the meta-analysis, with the center indicating the point estimate and the left and the right ends the 95% CI. (B) OR of CRT compared to control as a function of the mean QRS duration of participants at enrollment. ORs are displayed on a logarithmic scale. Circles represent the individual studies, and the size of each circle is proportional to the statistical weight of a trial in the meta-analysis. The fitted meta-regression function is drawn in a solid line accompanied by the upper and lower bounds for the 95% mean prediction interval (dotted lines).

Table 2
Meta-regression for all-cause death or hospitalization for heart failure (HF) as a function of covariates

The Bayesian random effects model yielded a wider range of credible intervals. As a result, the pooled OR of CRT compared to control treatment was statistically insignificant (OR, 0.84; 95% CrI, 0.67-1.10). Meta-regression with the Bayesian model showed a similar relationship and slope with wider credible ranges than did the REML estimate model. The ORs estimated from the Bayesian approach were 1.00 (95% CrI, 0.73-1.36) for a QRS duration of 125 ms, and 0.78 (95% CrI, 0.64-1.00) for 156 ms.

Hospitalization for HF

A total of 16 trials comprising 7,511 patients contributed to the analysis for the secondary endpoint, hospitalization for HF. No significant publication bias was present (P=0.113). While CRT was shown to reduce the risk by as much as 41% (OR, 0.59; 95% CI, 0.47-0.74; P<0.001), there was a high degree of heterogeneity between studies (I2=54%, P=0.006) (Fig. 4A). Among a variety of study-level variables, QRS duration best explained the difference between studies (Fig. 4B). The meta-regression showed that the magnitude of risk reduction in HF hospitalization was greater with an increased duration of the QRS complex (log OR=-0.01×[QRS duration]+1.11; P=0.009). According to the model, the estimated ORs were 0.83 (95% CI, 0.62-1.11) for a QRS duration of 120 ms and 0.60 (95% CI, 0.50-0.71) for 150 ms. The shortest QRS duration at which CRT was significantly better was 127 ms (OR, 0.77; 95% CI, 0.60-0.98). The QRS duration where CRT was equivalent to control treatment in terms of HF hospitalization was found to be 103 ms. No other study covariates were significantly associated with the relative efficacy of CRT, while QRS morphology showed marginal significance (P=0.097) (Table 2).

Fig. 4
Meta-analysis and meta-regression for hospitalization for heart failure (HF). (A) Forest plot with odds ratios (OR) for hospitalization for HF after cardiac resynchronization therapy (CRT) compared to control treatment for individual trials and the pooled population. The squares and the horizontal lines indicate the ORs and the 95% confidence intervals (CI) for each trial included. The size of each square is proportional to the statistical weight of a trial in the meta-analysis. A diamond indicates the effect estimate derived from the meta-analysis, with the center indicating the point estimate and the left and the right ends the 95% CI. (B) OR for HF hospitalization after CRT compared to control as a function of the mean QRS duration of participants at enrollment. ORs are displayed on a logarithmic scale. Circles represent the individual studies, and the size of each circle is proportional to the statistical weight of the trial in the meta-analysis. The fitted meta-regression function is drawn in a solid line accompanied by the upper and lower bounds for the 95% mean prediction interval (dotted lines).

The Bayesian random effects model yielded similar results. The pooled estimate of OR was 0.58 (95% CrI, 0.44-0.75). Meta-regression with empirical Bayesian estimates showed that for QRS durations ≥127 ms CRT significantly reduced the risk of HF hospitalization (OR, 0.74; 95% CrI, 0.50-0.99).

Subgroup analysis

Included trials were divided into two subgroups according to the treatment modality of the control group, i.e. medical treatment or ICD. Two trials were excluded from this analysis because of difficulties determining the precise classification. In one of these trials, the decision to implant CRT-P or CRT-D was left to the discretion of the treating physician, and patients were randomized to CRT-ON or CRT-OFF groups while keeping a double dummy (4). Another trial enrolled patients undergoing BMMC, which cannot be classified as a "conventional" medical treatment (27). Meta-analysis showed that CRT was associated with a significant survival benefit when compared to medical treatment (OR, 0.64; 95% CI, 0.53-0.78; P<0.001) but not when compared to ICD (OR, 0.98; 95% CI, 0.77-1.26; P=0.901, P for interaction=0.024). Notably, the relative efficacy of CRT vs. ICD relied upon the duration of the QRS complex (P=0.002): CRT was better than ICD only when the QRS complex was wide. Meanwhile, the benefit of CRT versus medical treatment was independent of the QRS duration (P=0.271) (P for interaction=0.015).

No significant interactions were found in subgroup analyses for either NYHA function class (P=0.628) or follow-up duration (P=0.626).

Sensitivity analysis

A sensitivity analysis was done for studies with a low risk of bias. Eighteen out of 23 trials met the "low risk of bias" criteria that were defined in this study. The sensitivity analysis generally agreed with the main analysis: the pooled OR was 0.81 (95% CI, 0.67-0.99; P=0.041) for all-cause mortality and 0.60 (95% CI, 0.48-0.75; P<0.001) for HF hospitalization. In addition, meta-regression for trials with low risk of bias also resulted in similar outcomes compared with analyses including all trials (Table 2).

DISCUSSION

In this systematic review and meta-analysis, we found that 1) CRT reduced the risk of all-cause mortality and hospitalization for HF, 2) the benefit of CRT was dependent on the duration of QRS complex, 3) the cutoff value of a QRS duration at which significant benefit was observed differed according to which endpoint of interest was investigated, and 4) the relationship between the advantage of CRT and QRS duration was significant only when compared to ICD, not to medical treatment.

Current guidelines strongly recommend CRT implantation in symptomatic HF patients with sinus rhythm, low LVEF, and a prolonged QRS duration (9, 10). However, there are ongoing controversies regarding specific indications for CRT, among which QRS duration is one of the most debated. Recently, the ACCF/AHA guidelines limited the Class I indication for CRT to patients with a QRS duration ≥150 ms (9, 30). However, a QRS duration of 120-150 ms is still recommended as the Class I indication in the European Society of Cardiology (ESC) guidelines if the patient has an LBBB pattern and depressed LVEF (30). The recent change in the ACCF/AHA guidelines was triggered by evidence from clinical trials where subgroup analyses showed a better response to CRT in patients with a wider QRS duration (≥150 ms) (4, 7, 31, 32). A recent meta-analysis also showed the reduction in adverse events associated with CRT was limited to patients with a QRS duration ≥150 ms, but not evident in patients with a QRS duration <150 ms (11). Contradictory evidence also exists. A post-hoc analysis of CARE-HF, one of the pivotal trials, showed that QRS duration at baseline had no value in predicting unfavorable outcomes (12).

Recent major CRT trials focused on expanding the indications for CRT. The NARROW-CRT and EchoCRT trials studied patients in whom the QRS interval was narrow but intraventricular dyssynchrony was evident on echocardiography (11, 17). The LESSER-EARTH and RESPOND trials also enrolled patients with a narrow QRS complex, but did not require the presence of LV dyssynchrony (15, 16). The rationale of these trials was built on the findings of a discrepancy between dyssynchrony as assessed by echocardiography and QRS duration assessed by electrocardiogram (33, 34). However, these trials showed conflicting results: some were positive (15, 17), while the others were negative including a well-designed large-scale trial (16, 18). They are reflected in this meta-analysis in the marginal benefit of CRT observed and the substantial degree of heterogeneity across trials. The results here are in contrast to previous meta-analyses which clearly showed a significant survival gain with little or no heterogeneity (35, 36). Understanding the source of the wide heterogeneity with a meta-regression method was the primary objective of this study.

To the best of our knowledge, this study is the first systematic study-level meta-regression to explore covariates that explain the benefit of CRT. With the use of the meta-regression method, we were able to identify QRS duration at baseline as the most reliable predictor for hard clinical events after CRT. There was a clear linear relationship between the benefit of CRT and the duration of the QRS complex. This study provides an important new data that highlights the importance of considering QRS duration when selecting patients for CRT implantation. The expected benefit of CRT in patients with a QRS duration ≥150 ms is unquestionable in terms both of all-cause death and HF hospitalization. In patients with a QRS duration between 130-150 ms, the odds for survival tended to be favorable, but is not definitive. However, a risk reduction in terms of hospitalization for HF is still expected for these patients. In the meantime, CRT use in patients with a QRS duration <130 ms showed little advantage, if any, in terms of admission for HF aggravation. Interestingly, this may actually do more harm than good in terms of death from any cause. It should be reminded that periprocedural complications and inappropriate defibrillator shocks may follow CRT implantation (18, 37). We believe this study provides an important insight into the understanding of current CRT trials, and a firm basis to clinical practice guidelines.

The variable effects of a prolonged QRS duration between trials may be explained by differences in the study design. This meta-regression implied the benefit of CRT does not depend on QRS duration when compared to medical therapy. In CARE-HF and COMPANION, in which the control arm was medical treatment, the influence of a prolonged QRS duration was less evident (7, 8). In contrast, MADIT-CRT, and RAFT compared CRT-D versus ICD (31, 32), and in the REVERSE trial, more than 80% of patients received CRT-D (4). These trials revealed a prominent impact of an increased QRS duration on the benefit of CRT.

The major strength of this study is the fact that this is the only existing meta-regression in its true sense. A meta-analysis by Sipahi did analyze relative risks according to QRS duration, but they did not measure actual QRS durations. Instead that study used ranks estimated according to the degree of prolongation among all subgroups (11). In addition, a variety of statistical models performed in this study corroborated the main findings. In statistical terms, REML or Bayes estimates are the preferred methods for meta-regression, as conventional random effects models ignore the imprecision in the between-trial variance estimate (38). The main results here were also confirmed by a sensitivity analysis done with low risk-of-bias trials only after all included trials were thoroughly examined for potential risks of bias with the Cochrane Collaboration's tool.

Caution should be taken in interpreting the negative results of this study, especially regarding LBBB. In the current study, the benefit of CRT had only marginal significance with the proportion of LBBB in terms of HF hospitalization. However, subgroup analyses of major clinical trials and a meta-analysis consistently showed a greater benefit in patients with complete LBBB compared with nonspecific intraventricular conduction delay or RBBB (7, 8, 31, 32, 39, 40). It should be noted that this meta-regression for QRS morphology was limited in several aspects. First, trials with narrow QRS duration were excluded in this analysis (15, 16, 17, 18). As a result, only 7 trials contributed to this analysis so that the statistical power was too low to show statistical significance. Second, the proportions of LBBB in each trial were in too a narrow range. Third, in addition, the 2 trials with the highest weight had a similar proportion of LBBBB (71% in the MADIT-CRT, and 72% in the RAFT) (31, 32).

This study has several limitations. First, this meta-analysis was comprised of 23 randomized trials and inherently shares the limitations of each trial. Two trials included in this analysis have not been peer-reviewed, and several studies were revealed to have a profound risk of bias. However, sensitivity analysis excluding those high risk-of-bias trials validated the main analysis. Second, each study included had a different trial design. The duration of follow-up was profoundly inhomogeneous, and the spectrum of optimal medical treatment evolved drastically over the last 15 yr since the landmark MUSTIC SR trial began enrolling patients (5). To overcome this limitation, we performed several subgroup analyses according to the study design. Third, the benefit of CRT depends not only on baseline patient characteristics, but also on technical factors such as left ventricular lead position or device optimization. However, we still lack data on the optimal protocol or lead positioning except for unfavorable outcomes observed after LV apex positioning (41). These factors were beyond the scope of this study. Fourth, this study was a study-level meta-regression and lacked individual patient-level data which would have permitted a more thorough investigation. Fifth, since multiple testing was done in this study, we cannot exclude the possibility of false positives. Last but not least, the meta-regression associations are observational in nature and should not be interpreted as if they came from randomized comparisons (38).

As a conclusion, CRT compared to control treatment was shown to reduce the risk of all-cause mortality and hospitalization for HF. The relative benefit increased with the prolongation of the QRS duration. This study concludes that patients with a QRS duration ≥150 ms would most benefit from CRT, and patients with a QRS duration <130 ms should not be considered for CRT implantation as it may be potentially be harmful in terms of clinical adverse events.

Notes

The authors have no potential financial conflicts on this subject.

Conception and design of the study: IY Oh, S Oh. Acquisition of data: SH Kang, IY Oh, DY Kang. Statistical analysis: SH Kang, S Hahn. First draft of manuscript: SH Kang, IY Oh. Revision and critical review of the manuscript: MJ Cha, Y Cho, EK Choi, S Oh. Manuscript approval: all authors.

References

    1. Roger VL, Go AS, Lloyd-Jones DM, Benjamin EJ, Berry JD, Borden WB, Bravata DM, Dai S, Ford ES, Fox CS, et al. American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Heart disease and stroke statisticsz: 2012 update: a report from the American Heart Association. Circulation 2012;125:e2–e220.
    1. Cazeau S, Ritter P, Bakdach S, Lazarus A, Limousin M, Henao L, Mundler O, Daubert JC, Mugica J. Four chamber pacing in dilated cardiomyopathy. Pacing Clin Electrophysiol 1994;17:1974–1979.
    1. Aaronson KD, Schwartz JS, Chen TM, Wong KL, Goin JE, Mancini DM. Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation. Circulation 1997;95:2660–2667.
    1. Linde C, Abraham WT, Gold MR, John John M St, Ghio S, Daubert C. REVERSE (REsynchronization reVErses Remodeling in Systolic left vEntricular dysfunction) Study Group. Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms. J Am Coll Cardiol 2008;52:1834–1843.
    1. Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C, Garrigue S, Kappenberger L, Haywood GA, Santini M, et al. Multisite Stimulation in Cardiomyopathies (MUSTIC) Study Investigators. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 2001;344:873–880.
    1. Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, et al. MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002;346:1845–1853.
    1. Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004;350:2140–2150.
    1. Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, Tavazzi L. Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005;352:1539–1549.
    1. Tracy CM, Epstein AE, Darbar D, DiMarco JP, Dunbar SB, Estes NA 3rd, Ferguson TB Jr, Hammill SC, Karasik PE, Link MS, et al. American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. [corrected]. Circulation 2012;126:1784–1800.
    1. Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J 2013;34:2281–2329.
    1. Sipahi I, Carrigan TP, Rowland DY, Stambler BS, Fang JC. Impact of QRS duration on clinical event reduction with cardiac resynchronization therapy: meta-analysis of randomized controlled trials. Arch Intern Med 2011;171:1454–1462.
    1. Gervais R, Leclercq C, Shankar A, Jacobs S, Eiskjaer H, Johannessen A, Freemantle N, Cleland JG, Tavazzi L, Daubert C. CARE-HF investigators. Surface electrocardiogram to predict outcome in candidates for cardiac resynchronization therapy: a sub-analysis of the CARE-HF trial. Eur J Heart Fail 2009;11:699–705.
    1. Zareba W, Klein H, Cygankiewicz I, Hall WJ, McNitt S, Brown M, Cannom D, Daubert JP, Eldar M, Gold MR, et al. MADIT-CRT Investigators. Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT). Circulation 2011;123:1061–1072.
    1. Beshai JF, Grimm RA, Nagueh SF, Baker JH 2nd, Beau SL, Greenberg SM, Pires LA, Tchou PJ. Cardiac-resynchronization therapy in heart failure with narrow QRS complexes. N Engl J Med 2007;357:2461–2471.
    1. Foley PW, Patel K, Irwin N, Sanderson JE, Frenneaux MP, Smith RE, Stegemann B, Leyva F. Cardiac resynchronisation therapy in patients with heart failure and a normal QRS duration: the RESPOND study. Heart 2011;97:1041–1047.
    1. Thibault B, Harel F, Ducharme A, White M, Ellenbogen KA, Frasure-Smith N, Roy D, Philippon F, Dorian P, Talajic M, et al. LESSER-EARTH Investigators. Cardiac resynchronization therapy in patients with heart failure and a QRS complex <120 milliseconds: the Evaluation of Resynchronization Therapy for Heart Failure (LESSER-EARTH) trial. Circulation 2013;127:873–881.
    1. Muto C, Solimene F, Gallo P, Nastasi M, La Rosa C, Calvanese R, Iengo R, Canciello M, Sangiuolo R, Diemberger I, et al. A randomized study of cardiac resynchronization therapy defibrillator versus dual-chamber implantable cardioverter-defibrillator in ischemic cardiomyopathy with narrow QRS: the NARROW-CRT study. Circ Arrhythm Electrophysiol 2013;6:538–545.
    1. Ruschitzka F, Abraham WT, Singh JP, Bax JJ, Borer JS, Brugada J, Dickstein K, Ford I, Gorcsan J 3rd, Gras D, et al. EchoCRT Study Group. Cardiac-resynchronization therapy in heart failure with a narrow QRS complex. N Engl J Med 2013;369:1395–1405.
    1. Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0. the Cochrane Collaboration; [updated March 2011]. [accessed on 06 December 2013].
    1. DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials 1986;7:177–188.
    1. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ 2003;327:557–560.
    1. Thompson SG, Sharp SJ. Explaining heterogeneity in meta-analysis: a comparison of methods. Stat Med 1999;18:2693–2708.
    1. NICE Decision Support Unit. Heterogeneity: subgroups, meta-regression, bias and bias-adjustment. [accessed on 06 December 2013].
    1. Jonas DE, Wilkins TM, Bangdiwala S, Bann CM, Morgan LC, Thaler KJ, Amick HR, Gartlehner G. Findings of Bayesian mixed treatment comparison meta-analyses: comparison and exploration using real-world trial data and simulation. [accessed on 06 December 2013].
    1. Gelman A, Rubin DB. Inference from iterative simulation using multiple sequences. Stat Sci 1992:457–472.
    1. Pokushalov E, Romanov A, Prohorova D, Cherniavsky A, Goscinska-Bis K, Bis J, Bochenek A, Karaskov A. Coronary artery bypass grafting with concomitant cardiac resynchronisation therapy in patients with ischaemic heart failure and left ventricular dyssynchrony. Eur J Cardiothorac Surg 2010;38:773–780.
    1. Pokushalov E, Romanov A, Corbucci G, Prohorova D, Chernyavsky A, Larionov P, Terekhov I, Artyomenko S, Kliver E, Shirokova N, et al. Cardiac resynchronization therapy and bone marrow cell transplantation in patients with ischemic heart failure and electromechanical dyssynchrony: a randomized pilot study. J Cardiovasc Transl Res 2011;4:767–778.
    1. Summary of Safety and Effectiveness Data: St. Jude Epic and Atlas+HF CRT-D Systems. [accessed on 02 November 2013].
    1. Summary of Safety and Effectiveness Data: St. Jude Frontier Cardiac Resynchronizatio Therapy. [accessed on 02 November 2013].
    1. Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE Jr, Drazner MH, Fonarow GC, Geraci SA, Horwich T, Januzzi JL, et al. 2013 ACCF/AHA guideline for the management of heart failure: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines. Circulation 2013;128:1810–1852.
    1. Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, Estes NA 3rd, Foster E, Greenberg H, Higgins SL, et al. Cardiac-resynchronization therapy for the prevention of heart-failure events. N Engl J Med 2009;361:1329–1338.
    1. Tang AS, Wells GA, Talajic M, Arnold MO, Sheldon R, Connolly S, Hohnloser SH, Nichol G, Birnie DH, Sapp JL, et al. Resynchronization-Defibrillation for Ambulatory Heart Failure Trial Investigators. Cardiac-resynchronization therapy for mild-to-moderate heart failure. N Engl J Med 2010;363:2385–2395.
    1. Yu CM, Lin H, Zhang Q, Sanderson JE. High prevalence of left ventricular systolic and diastolic asynchrony in patients with congestive heart failure and normal QRS duration. Heart 2003;89:54–60.
    1. Ku SY, Cho GY, Han SW, Choi SH, Park WJ, Doo YC, Hong KS, Oh DJ, Lee Y. Doppler tissue image for diagnosis of myocardial dyssynchronicity in congestive heart failure: comparison with EKG. Korean Circ J 2004;34:388–394.
    1. McAlister FA, Ezekowitz J, Hooton N, Vandermeer B, Spooner C, Dryden DM, Page RL, Hlatky MA, Rowe BH. Cardiac resynchronization therapy for patients with left ventricular systolic dysfunction: a systematic review. JAMA 2007;297:2502–2514.
    1. Al-Majed NS, McAlister FA, Bakal JA, Ezekowitz JA. Meta-analysis: cardiac resynchronization therapy for patients with less symptomatic heart failure. Ann Intern Med 2011;154:401–412.
    1. Yancy CW, McMurray JJ. ECG: still the best for selecting patients for CRT. N Engl J Med 2013;369:1463–1464.
    1. Thompson SG, Higgins JP. How should meta-regression analyses be undertaken and interpreted? Stat Med 2002;21:1559–1573.
    1. Gold MR, Thébault C, Linde C, Abraham WT, Gerritse B, Ghio S, John Sutton M St, Daubert JC. Effect of QRS duration and morphology on cardiac resynchronization therapy outcomes in mild heart failure: results from the Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE) study. Circulation 2012;126:822–829.
    1. Sipahi I, Chou JC, Hyden M, Rowland DY, Simon DI, Fang JC. Effect of QRS morphology on clinical event reduction with cardiac resynchronization therapy: meta-analysis of randomized controlled trials. Am Heart J 2012;163:260–267.e3.
    1. Singh JP, Klein HU, Huang DT, Reek S, Kuniss M, Quesada A, Barsheshet A, Cannom D, Goldenberg I, McNitt S, et al. Left ventricular lead position and clinical outcome in the multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) trial. Circulation 2011;123:1159–1166.
    1. Higgins SL, Hummel JD, Niazi IK, Giudici MC, Worley SJ, Saxon LA, Boehmer JP, Higginbotham MB, De Marco T, Foster E, et al. Cardiac resynchronization therapy for the treatment of heart failure in patients with intraventricular conduction delay and malignant ventricular tachyarrhythmias. J Am Coll Cardiol 2003;42:1454–1459.
    1. Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B, Canby RC, Schroeder JS, Liem LB, Hall S, et al. Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE ICD) Trial Investigators. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA 2003;289:2685–2694.
    1. Abraham WT, Young JB, León AR, Adler S, Bank AJ, Hall SA, Lieberman R, Liem LB, O'Connell JB, Schroeder JS, et al. Multicenter InSync ICD II Study Group. Effects of cardiac resynchronization on disease progression in patients with left ventricular systolic dysfunction, an indication for an implantable cardioverter-defibrillator, and mildly symptomatic chronic heart failure. Circulation 2004;110:2864–2868.
    1. Chung ES, Menon SG, Weiss R, Schloss EJ, Chow T, Kereiakes DJ, Mazur W, Salo RW, Galle E, Pastore JM. Feasibility of biventricular pacing in patients with recent myocardial infarction: impact on ventricular remodeling. Congest Heart Fail 2007;13:9–15.
    1. Bentkover JD, Dorian P, Thibault B, Gardner M. Economic analysis of a randomized trial of biventricular pacing in Canada. Pacing Clin Electrophysiol 2007;30:38–43.