Review

Single-Use Bioreactors for Human Pluripotent and Adult Stem Cells: Towards Regenerative Medicine Applications

by
Diogo E.S. Nogueira
1,2,
Joaquim M.S. Cabral
1,2 and
Carlos A.V. Rodrigues
1,2,*
1
Department of Bioengineering and iBB—Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
2
Associate Laboratory i4HB—Institute for Health and Bioeconomy, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
*
Author to whom correspondence should be addressed.
Submission received: 11 April 2021 / Revised: 10 May 2021 / Accepted: 12 May 2021 / Published: 17 May 2021

Abstract

:
Research on human stem cells, such as pluripotent stem cells and mesenchymal stromal cells, has shown much promise in their use for regenerative medicine approaches. However, their use in patients requires large-scale expansion systems while maintaining the quality of the cells. Due to their characteristics, bioreactors have been regarded as ideal platforms to harbour stem cell biomanufacturing at a large scale. Specifically, single-use bioreactors have been recommended by regulatory agencies due to reducing the risk of product contamination, and many different systems have already been developed. This review describes single-use bioreactor platforms which have been used for human stem cell expansion and differentiation, along with their comparison with reusable systems in the development of a stem cell bioprocess for clinical applications.

1. Introduction

The expression “regenerative medicine” dates back to at least 1992 [1], but its concept, the regeneration of tissues and cells damaged by ageing or disease, can be found as far back as Greek mythology [2,3]. Enraged by Prometheus’s betrayal, Zeus chained him to a rock and had his liver being eaten by an eagle every day, while it would fully regenerate every night. While regenerative medicine is not yet this efficient, landmark discoveries in stem cell biology and bioengineering in the past few years are leading to exciting advances that may revolutionise the field in the next decades.
Stem cells do not have a specialised function but, at the same time, are of crucial importance for human development and homeostasis. Stem cells can self-renew, generating identical copies of themselves upon division, and differentiate into specific, functional cells. The extent of cell types into which stem cells can differentiate depends on their potency.
Human pluripotent stem cells (hPSCs) can differentiate into any of the cell types comprising the human body (but not extraembryonic tissues). hPSCs include human embryonic stem cells (hESCs), which result from the in vitro culture of cells from the inner cell mass of the blastocyst [4], and human-induced pluripotent stem cells (hiPSCs), which are obtained by reprogramming of somatic cells [5,6]. Since the derivation of hESCs requires the destruction of human embryos, their use is forbidden in various countries. hiPSCs do not carry this ethical burden and can be derived from the patients’ own cells, thus overcoming the possibility of immune rejection. Besides regenerative medicine, hPSCs have been regarded as a promising source of cells for a variety of other applications such as drug screening and disease modelling [7], due to their ability to provide, in vitro, cells—or even structures—from diverse human systems and organs such as the heart, the central nervous system, or the liver [8,9].
The adult body also contains stem cells, responsible for the replacement/generation of specific cell types. Most of these stem cells are multipotent, generating only a limited number of different lineages. Concerning regenerative medicine applications, human mesenchymal stromal cells (hMSCs) are commonly regarded as promising candidates for cell therapies. These cells can differentiate into lineages such as bone, cartilage, and fat, and can be found in a variety of tissues, including the bone marrow (BM), umbilical cord matrix (UCM), adipose tissue (AT), peripheral blood, and synovial tissue [10]. hMSCs have been shown to be less immunogenic than other cells, allowing them to avoid adverse immune effects when transplanted to an allogeneic host, and also immunomodulatory, tuning and reducing the immune response of the host [11,12,13]. These characteristics have led to the exploration of hMSCs and their secretome for regenerative medicine applications (e.g., bone, cartilage, skin or trachea regeneration [14,15,16]), as well as for treatment and prevention of immune diseases, such as graft-versus-host disease, Crohn’s disease and multiple sclerosis [11,12,15]. hMSCs may also be promising for the treatment of patients afflicted with COVID-19, although some studies are still required on their safety and efficacy in this regard [17].
Nevertheless, despite the promise of both these types of stem cells, this promise can only be fulfilled if the cells can be expanded in a robust and reproducible manner to achieve the number of clinical-grade cells necessary for a patient. Effective hMSC doses are around 108 cells/patient, with maximal effectiveness, in most clinical trials, with doses in the range of 70 million to 190 million cells/patient (intravenous administration requiring higher doses due to loss of some MSCs in the lungs) [18]. Point studies, however, have successfully applied higher dosages, including a phase 1b/2a clinical trial with 6.0 × 108 MSCs/dose for Crohn’s disease [19] and a phase 2 clinical trial for acute ischaemic stroke using 1.2 × 109 MSCs/dose [20]. In the case of hiPSC derivatives, one dose may constitute 109–1010 cells [21]. Many stem cell bioprocesses, especially at lab scale, still employ planar culture platforms, including cell culture plates, T-flasks, or multi-plate trays. While cells produced in this manner may express normal markers and differentiation potential, as described in many studies, the 2D culture format affects their phenotype, altering surface marker localisation and sensitivity to signalling, as well as their behaviour, in terms of cellular processes such as expansion, differentiation, and apoptosis [22,23]. Therefore, these cells may not be of ideal quality for transplantation or for in vitro studies. Moreover, the increase in the scale of the vast majority of 2D platforms can only be performed using a scale-out approach—increasing the parallel number of culture vessels (plates, flasks, etc.)—rendering them unpractical or even unfeasible for the production of cells at a clinical scale.
Bioreactors have been long since established as promising platforms for the manufacturing of a number of different bioproducts [24,25,26,27] since they provide an agitated and homogenised 3D environment, as well as generally being available at many scales, allowing for scale-up approaches—increasing the size of the bioreactor itself. Furthermore, bioreactor vessels are typically equipped with probes, which can measure crucial culture variables such as pH, dissolved oxygen, and nutrient and metabolite concentrations (e.g., glucose and lactate, respectively), and which are associated with a controller system, which can react when these variables approach the limits of the established operating range, for instance, by adding acid/base, increasing aeration, changing the agitation speed or changing the culture medium flow rate. This know-how from traditional biological products has already been applied to stem cells, and various different studies already describe the expansion and/or differentiation of stem cells in different bioreactor configurations [28].
This review will detail the importance of single-use bioreactors in the production of stem cells for clinical applications, as well as explore some of the bioreactor systems which have already been described for the bioproduction of stem cells such as hPSCs and hMSCs.

2. Single-Use Bioreactors for Stem Cell Biomanufacturing

Despite all the advances in stem cell products for human use, regulation by agencies such as the European Medicines Agency (EMA) and the US Food and Drug Administration (FDA) is a critical concern. EudraLex (available online at https://ec.europa.eu/health/documents/eudralex, accessed on 11 April 2021) details the legislation for pharmaceutical products in the European Union, and Volume 4, in particular, details the guidelines for good manufacturing practices (GMP) for medicinal products for human and veterinary use. These GMP apply to various steps of the life of a stem cell product, from the cell bank establishment and maintenance to the manufacturing, downstream processing, fill, and finish (Figure 1). Among other things, GMP guidelines aim to avoid product contamination, thus requiring the sterilisation of the reagents and materials. Whenever possible, cleaning in place (CIP) and steaming in place (SIP) should be applied to sterilise materials between batches. The same regulation also permits and suggests the use of single-use technologies (EudraLex Volume 4, Part IV). In particular, the bioreactor parts which directly contact the cells can be disposable, which minimises the risk of contamination, and overrides the need for their sterilisation, thus reducing the time between batches and allowing a faster process pipeline and, thus, higher productivity.
The following sections will detail some single-use bioreactor platforms which have already been successfully applied in the biomanufacturing of stem cells. A summary of the results obtained in these bioreactors is presented in Table 1.

2.1. Single-Use Stirred-Tank Bioreactors

Stirred-tank bioreactors (STBRs) have been among the most commonly used setups for the manufacturing of a variety of products, such as viruses or recombinant proteins, in a multitude of cell types including bacterial, insect, plant, or animal cells [24,25,26,27]. STBRs typically employ a glass or stainless-steel vessel, along with one or multiple impellers distributed along the height of the bioreactor and ensuring efficient agitation of the medium (Figure 2). Depending on the frailty of the cells, different impellers can be employed—Rushton turbines are suitable for more resistant cell types, such as bacteria, while animal cells, which are more shear sensitive, require gentler mechanisms of agitation such as marine or pitched-blade impellers. In fact, shear stress is a common point of contention in the translation of stem cell culture to 3D, due to its effect on cell fate (reviewed in [72,73]). Nevertheless, there is a notorious lack of studies in this regard, with only a few reports of phenomena such as agitation-induced hPSC differentiation [74], as well as priming of hMSCs towards an osteogenic fate through high shear stress [75]. The decades of STBR use in the biopharmaceutical industry ensures these bioreactors are now very well characterised, in terms of agitation profiles, shear stress, power dissipation, and oxygen mass transfer, with well-established empirical correlations, as well as defined criteria for scale-up [76,77,78]. In STBRs, however, the existence of “hot spots” of high shear forces has been described as well as “dead zones” where mixing is inferior or almost inexistent. This heterogeneous mixing profile may give cues for undue cell differentiation and/or apoptosis due to the high shear itself or cell settling and formation of very large cell aggregates.
The STBR can be easily converted into a single-use system, by replacing parts which contact the cells with disposable equipment, such as the vessel itself, the impeller, and the probes. Examples of commercially available single-use STBRs which have already been successfully applied for stem cell culture are described in Table 2. Together, these systems cover from a 10 mL laboratory scale to a 200 L production scale.
Kropp et al. have described the expansion of hiPSCs as aggregates in BioBLU (from Eppendorf, Hamburg, Germany) bioreactors (125 mL working volume), using different feeding strategies. By applying a perfusion strategy, in which constant withdrawal of wasted medium and replenishment of fresh medium are performed (retaining the cells inside the vessel), the cell yield was improved by 47%, in comparison to a repeated batch approach, with a discrete medium exchange every 24 h. The authors obtained a final density of (2.85 ± 0.34) × 106 cells∙mL–1, although with a shift to a metabolism more reliant on oxidative phosphorylation [29]. Kwok et al. expanded hiPSCs as aggregates in Mobius CellReady (from Merck, Darmstadt, Germany) bioreactors at a 1.5 L scale, generating a total of 2 billion cells [30]. hPSC differentiation in STBRs is also possible—Halloin et al. have adapted a standard cardiac differentiation protocol and report the generation of about 1 × 106 cardiomyocytes∙mL–1 at both 100 mL and 350–500 mL scales, with purity above 90%. The bioreactors used in this study are available with both single-use and reusable vessels, which should allow for easy transition of protocols developed on one of those formats to the other [79].
Microcarrier-adherent hMSC expansion has also been described, in Mobius CellReady (from Merck, Darmstadt, Germany), UniVessel SU (from Sartorius, Göttingen, Germany), and CultiBag STR (from Sartorius, Göttingen, Germany) bioreactors. Schirmaier et al. optimised AT-derived hMSC culture at a 2 L scale, followed by a scale-up experiment to 35 L, and were able to maintain a similar cell density at both scales—(0.27 ± 0.02) × 106 cells∙mL–1 and 0.31 × 106 cells∙mL−1, respectively [34]. Lawson et al. attempted BM–hMSC culture at a 50 L scale, obtaining 1.28 × 1010 cells in 11 days of culture [36].
While obtaining high cell numbers is vital for the production of cells to be used in a clinical setting, bioprocess optimisation is preferably performed in a high-throughput platform. Ratcliffe et al. performed human haematopoietic stem/progenitor cell (hHSPC) expansion in the Ambr (from Sartorius, Göttingen, Germany) 15 bioreactor system, a fully automated and controlled platform entailing 24 vessels with 15 mL maximum volume, allowing for the simultaneous testing of many different conditions. By optimising culture parameters, including inoculation density, oxygen tension, and medium feeding, the authors could obtain a maximum density of 1.37 × 107 cells∙mL–1 in 11 days [37]. This platform was also used for optimisation of BM–hMSC expansion with microcarriers in serum-free medium, resulting in over 8.1 × 105 cells∙mL−1 and a 10-fold increase in reproducibility in comparison to serum-containing, manual culture [31].

2.2. Fixed-Bed Bioreactors

Fixed-bed bioreactors are a common staple of the food and wastewater industry due to their setup—a vessel filled with a macroporous material or large beads to which cells and/or enzymes may be attached, and through which the liquid phase is passed through continuously (Figure 3). In fact, many studies have already described the use of fixed-bed bioreactors for applications such as the production of biodiesel [80,81] and biohydrogen [82], and various aspects of wastewater treatment [83,84]. Beyond the possibility for these applications, fixed-bed bioreactors also have some characteristics which have led to their use for culture of anchorage-dependant mammalian cells. The geometry and setup of these bioreactors confer a large surface-to-volume ratio, allowing for a smaller footprint, compared to stirred-tank bioreactors, and enabling a much higher volumetric productivity. Depending on their mechanism, fixed-bed bioreactors may also be naturally compatible with a perfusion feeding regime, and, due to the lack of agitation, the shear stress conveyed to the cells is low. The lack of an impeller is, simultaneously, a disadvantage, due to allowing for the formation of concentration gradients (of nutrients, metabolites, growth factors, oxygen, etc.) inside the bioreactor. Moreover, cell harvesting until the end of the culture is impossible, rendering cell growth monitoring notably difficult. Nevertheless, fixed-bed bioreactors have seen used for applications such as viral production in mammalian cells [85,86,87], and even hHSPC expansion [88].
Single-use fixed-bed bioreactors require both a single-use vessel and cell adhesion matrix. Weber et al. have developed a small-scale disposable fixed-bed bioreactor system using a 3 mL plastic syringe, connected to two 250 mL flasks for medium feeding and for waste, and equipped with a small oxygen sensor in the outflow. This bioreactor system was used for the culture of alginate-encapsulated hMSC–TERTs. These cells are hMSCs transfected with telomerase, which compensates the telomere shortening which occurs during mitosis, thus enabling more population doublings in comparison to unaltered hMSCs [89]. These cells were not proliferative but could be maintained in culture for at least 500 hours with increasing viability [38]. The same group also described larger-scale fixed-bed bioreactor systems—using 60 mL glass syringes, and glass tubes between two stainless-steel plates (serving as lid and bottom) for a volume of 300 mL. These bioreactors were filled with 2 mm diameter non-porous borosilicate glass spheres which served as a surface for cell adhesion and made use of non-invasive oxygen sensors both at the inlet and the outflow. At the 300 mL scale, the authors were able to produce 6.2 × 108 hMSC–TERTs after 167.3 hours of culture, however, only 50% to 60% of the inoculated cells attached to the borosilicate spheres [39]. Mizukami et al. have used a commercial fixed-bed bioreactor system—FibraStage® bottles (discontinued) loaded with Fibra-Cel® disks, both from Eppendorf (previously from New Brunswick Scientific) for the expansion of human cord blood-derived hMSCs. The bellows at the base of the bottle control the medium level by compression and expansion. With one 500 mL FibraStage bottle, the authors could produce (4.15 ± 0.81) × 108 cells in 7 days of culture [40].

2.3. Hollow Fibre Bioreactors

Hollow fibre bioreactors are composed of numerous capillary tubes inside an outer shell, which, similarly to fixed-bed bioreactors, confer them a high surface area with a low footprint (Figure 4). In hollow fibre bioreactors, the cells adhere to the surface of the capillaries, either on the intracapillary (IC) or the extracapillary (EC) loop. Medium and reagents may be pumped through the loop in which the cells are adhered to, contacting them directly. The capillary membrane is semipermeable, thus also enabling the diffusion of dissolved gases and small molecules (e.g., glucose, lactate) through it, and allowing for mass exchange between the cells and the fluids perfused through the other loop [90]. Once more, the lack of an impeller reduces the shear stress conveyed to cells, especially due to the two-loop system and the possibility of indirect mass transfer. However, the growth of cells inside the hollow fibre bioreactors is hard to monitor due to the impossibility of cell harvesting until the end of culture. Having a membrane-based system also renders these bioreactors particularly susceptive to fouling—as the capillary membrane pores clog, either due to the cells or other solids, mass transfer through the capillaries becomes increasingly difficult [91]. The high cell densities which can be obtained in a hollow fibre reactor, along with the resulting high product titres, have led this configuration to be attractive for the production of recombinant proteins, monoclonal antibodies, and viruses [92,93,94] while also seeing the use for wastewater treatment [95,96] and biocatalytic reactions [97,98]. Furthermore, hollow fibre bioreactors have already been applied for the bioproduction of stem cells for clinical trials [43].
Regarding single-use hollow fibre bioreactors for stem cell expansion, many studies describe the use of the Quantum® Cell Expansion System (QES; Terumo BCT). This closed and fully automated system is composed of about 11,500 hollow fibres, providing a 2.1 m2 surface area for cell growth (the same as 120 T-175 flasks) with a 0.3 m2 footprint.
Roberts et al. have harvested up to 5.4 × 108 hESCs in 5 days in the QES, achieving 1.8-fold the cell density of T-25 flasks in an equivalent time, while reducing medium consumption per unit area in 68%, [41]. Mesquita et al. demonstrated hiPSCs could be expanded in the QES, and that laminin coating of the IC area was more favourable (both in terms of the maximum cell number and the time required to achieve it) for cell growth over vitronectin, possibly due to a stronger interaction of laminin with the QES fibres. Furthermore, to overcome some of the monitoring limitations of the bioreactor system, the authors correlated the total number of cells with the produced lactate, allowing them to estimate the growth curve of the hiPSCs. After 6–7 days of culture, the authors obtained an average of (6.9 ± 0.9) × 108 cells with laminin coating [42]. Tirughana et al. described the production of GMP-grade human neural stem cells (hNSCs) in the QES. These hNSCs were modified to produce the prodrug-activating enzyme cytosine deaminase. A total of 1.4–3 × 109 of these cells could be produced in one QES in 7–10 days, allowing for the production of an FDA-approved clinical lot (1.5 × 1010 cells) in seven parallel bioreactors in nine days, which was then used in a phase I trial with seven brain tumour patients. The same cell line was additionally modified by adenoviral transduction in the QES to produce a modified carboxylesterase, and 1.5–1.8 × 109 cells could be recovered after 8 days. Using 5 QES in parallel, a clinical lot of 8 × 109 transduced hNSCs was produced for a future study regarding the treatment of metastatic neuroblastoma patients [43].
The QES has already been extensively described for the culture of hMSCs of various sources – AT [45,48,51], BM [44,46,52], UCM [46,47,50], and periosteum [49]. Of these studies, Haack-Sørensen et al. were able to obtain the highest cell number. The authors performed a comparison of two media—foetal bovine serum (FBS) or human platelet lysate (hPL)-supplemented—for the derivation of hMSCs from an inoculum of the stromal vascular fraction of human subcutaneous abdominal fat, over the course of two passages in the QES. Overall, this study revealed hPL to be more favourable for cell growth. In the first passage, hPL increased cell yield by fivefold and in half of the expansion time when compared to FBS (9 days for hPL vs. 17 days for FBS). Both supplements led to comparable growth in the second passage, but with a higher difference in the expansion time (6 days for hPL vs. 21 days for FBS). FBS is an animal-derived supplement, which complicates the approval process in the case of a clinical-grade process. In contrast, hPL is of human origin, being free of xenogeneic components. Nevertheless, this supplement may also suffer from batch-to-batch variability [99]. At the end of culture, up to 5.5 × 108 AT–MSCs were obtained in 9 days from stromal vascular fractions, and 6.1 × 108 AT–MSCs were recovered after the first passage, following 6 days in culture [51]. Russell et al. have performed a cost breakdown, comparing automated hMSC expansion in the QES with manual culture for the production of 100 doses of 108 cells (for a clinical trial with 100 patients). The automated system allowed for savings of about 49% in reagents and consumables, having an estimated cost of about USD 108,000 for 100 doses, while hands-on work could be reduced from 361.6 h (in a 24.0 week production time, thus requiring two technologists) to 35.0 hours (for a 20.0 week production, demanding a single technologist) [44]. Mizukami et al. performed a more thorough cost-of-goods analysis, comparing a multilayer vessel, a stirred-tank bioreactor, a packed-bed bioreactor, and a QES. While the QES resulted in a higher cell proliferation rate, expansion fold, and harvesting efficiency, its high consumable and equipment cost led it to be predicted as the least cost-effective option. In fact, for the QES to compete with the other systems at an economical level, it would require a sevenfold increase in harvesting density, along with an 85% consumable and equipment cost reduction and a 28% cost savings in the medium [47].

2.4. Rotary Cell Culture Systems

The advancements in space travel in the past years have led to significant research on the effects of microgravity in humans, and more specifically, in some cell types. While cell culture has already taken off to space [100], microgravity can also be simulated on Earth. The rotary cell culture system (RCCS) is a bioreactor developed by NASA which can be used to culture cells in a microgravity environment (Figure 5). In this bioreactor system, the cells are inoculated in a high aspect ratio cylindrical vessel, which is completely filled with medium. The vessel rotates horizontally and will cause the medium inside to rotate as well. If operating at a certain range of speeds, after some time, the medium will rotate at the same velocity as the vessel itself, unlike in other bioreactor systems where the fluid is moving in reference to the vessel walls (e.g., agitated liquid and still vessel walls). This minimises the effect of the Earth’s gravity on the particles inside the vessel, resulting in an effective gravitational force of 10–2 × g [101]. Moreover, the particles inside the vessel have an almost null terminal velocity and therefore move with the medium upon the rotational axis, with limited movement alongside other axes—a cell will return to approximately the same location upon each complete vessel rotation. Therefore, the cells can be cultured in suspension in a laminar regime; thus, with minimal shear stress (< 5 × 10–2 Pa), further reduced by the lack of headspace and, consequently, no formation of air bubbles [101,102,103]. Ensuring both these effects will require the rotation of the RCCS in a limited velocity range—a low rotation speed will not overcome the Earth’s gravitational force, causing the cells to settle, while high rotation will result in a predominant centrifugal force which will drive the cells towards the outer wall (Figure 5b–d). Furthermore, while the low shear stress conveyed by the RCCS limits the extent of shear-mediated cell damage, it also limits mass transfer by convection. In fact, in the RCCS, diffusive mass transfer prevails, which may lead to the formation of microenvironments of low nutrient concentration and high waste accumulation in the vicinity of the cells [103,104].
Single-use RCCS operate using disposable vessels, or cassettes, as these are the only part of the bioreactor which directly contacts the cells. Single-use RCCS systems are available commercially from Synthecon but only at a 10 mL and 50 mL scale, limiting their scalability.
Chiang et al. have employed the RCCS for hESC-derived hNSC culture and observed the effect of simulated microgravity in the development of these cells. RCCS culture led to increased β-adrenoreceptor expression and subsequent mitochondrial function of hNSCs, with increased mitochondrial mass and ATP production. Moreover, the proliferation of the hNSCs was increased, leading to a final density of ~5 × 105 cells∙mL–1 after 3 days, a twofold increase over the static control [53]. The culture of adult BM–hMSCs in these bioreactors has also been described. Cells were harvested from BM and seeded in the RCCS in a chondrogenic medium. The results were compared with a standard protocol of cartilage production in conical tubes. After 2 weeks, RCCS culture led to about threefold larger (diameter-wise) and 10-fold heavier cellular constructs in relation to conical tubes, with a 1.5-fold higher glycosaminoglycan/DNA ratio and with histological and immunohistological characteristics of hyaline cartilage [54].

2.5. Rotating Bed Bioreactors

Rotating bed bioreactors apply rotation to the previously described fixed-bed system—the cells adhere to plates, which rotate inside the vessel (Figure 6). These bioreactors can be operated at full volume, or similarly to roller bottles, by not filling the vessel totally and allowing for the cells to intermittently contact the medium and the headspace. Rotating bed bioreactors share most advantages and disadvantages of fixed-bed bioreactors—both provide a large surface-to-volume ratio, are compatible with perfusion, and convey low shear stress to the cells, while cell harvesting and monitoring cannot be performed during the culture. Rotating bed bioreactors, however, can provide some more homogeneity to the contents of the vessel by means of rotation employed. Applications of these systems also include biocatalysis [105,106] and wastewater treatment [107,108], and it has already seen use in mammalian cell culture [109].
Zellwerk GmbH (Oberkrämer, Germany) has developed the disposable rotating bed Z®RP 2000 H and Z®RP 8000 H bioreactor systems, providing 2000 cm2 and 8000 cm2 of cell attachment area, respectively. These bioreactors consist of a cylindrical vessel containing a bed of polycarbonate plates which rotate through the action of a magnetic drive. Their setup allows for operation under a perfusion feeding regime. Moreover, they are equipped with a sampling device for supernatant analysis as well as pH and oxygen sensors connected to a control unit. The single-use parts comprise the vessel, tubing system, and measuring devices [55,56].
Neumann et al. characterised the Z®RP 2000 H bioreactor and applied it for UCM–hMSC expansion. The authors verified homogenisation of the culture under normal operating conditions for both a half-full (70 mL) and full (120 mL) vessel, and the Bodenstein number was characteristic of a stirred-tank reactor-type mixing even for the lowest mixing speed and full volume. After 5 days of culture, a total of (2.46 ± 0.24) × 107 hMSCs could be obtained at a 125 mL scale, maintaining hMSC immunophenotype and trilineage differentiation potential [55]. Reichardt et al. applied rotating bed bioreactors with a 6000 cm2 surface area and a 340 mL working volume for human umbilical cord artery cells (HUCACs), harvesting (3.48 ± 0.55) × 108 cells in 9 days, albeit with full depletion of glucose at some timepoints (despite the perfusion feeding regime). The authors compared bioreactor culture to maintenance in static T-25 flasks and estimated 311 of these flasks would be required to achieve the same cell numbers, encompassing an over threefold increase in the medium volume necessary (about 12.1 L versus 3.83 ± 0.69 L in the bioreactor) [56].

2.6. Rocking Motion Bioreactors

Rocking motion bioreactors were first described in 1998 [110] and were established as an alternative to STBR in the culture of insect and mammalian cells for processes such as the production of viruses and recombinant proteins. These bioreactors rely on an impeller-free agitation mechanism where the vessel, a plastic bag, is placed on the top of a base which moves in a back-to-forth rocking motion. The agitation causes the formation of waves in the air–liquid interface, ensuring efficient mixing, with a high mass transfer and no particle settling while also avoiding high shear stress (Figure 7) [111,112]. Cell damage is further avoided by the lack of a sparging mechanism and associated bubble formation. While the shear stress generally increases with the agitation velocity, at certain agitation speeds a resonance phenomenon is observed, causing unusual behaviour such as higher vorticity and shear stress. Zhan et al. observed that, for a half-filled 10 L rocking motion bioreactor, agitation at 15 rpm led to an approximation to the natural frequency of the bioreactor (calculated by approximating its shape to a perfect ellipse), causing higher turbulence than agitation at 22 rpm and 30 rpm [113]. Therefore, during process development with this bioreactor system, it is important to estimate the natural frequency and avoid choosing a rocking velocity close to this frequency.
Rocking motion bioreactors were first developed as single use, employing a disposable culture bag. Rocking motion bioreactors commercially available include the Xuri Cell Expansion System (previously WAVE BioreactorTM) and CellbagTM vessels from Cytiva (Marlborough, MA, USA), and the Biostat® RM and Flexisafe RM bags (replacing CultiBag) from Sartorius (Göttingen, Germany), and cover working volumes from 50 mL up to 500 L.
Davis et al. have cultured both hESCs and hiPSCs as aggregates in the Xuri Cell Expansion System, with perfusion and non-perfusion Cellbags, at various scales—150 mL, 250 mL, and 1 L—and also performed consecutive passage experiments. The authors also optimised the culture conditions and were able to obtain up to 9.5-fold expansion in 4 days. Serial passaging from 250 mL to 1 L under optimised conditions led to a 39.2-fold expansion (~3.9 × 109 cells in 8 days), while passages from two sequential 150 mL bioreactors to 250 mL and to 1 L in non-optimised conditions resulted in a cumulative 280-fold increase in cell number (~1.7 × 1010 cells in 16 days). The authors also estimated how operating these bioreactors under automated perfusion, besides allowing a closed process and ensuring sterility, could lead to a substantial increase in cell yield per spent medium—from 4.2 × 105 cells/mL in six-well plates to 1.5 × 106 cells/mL in 1 L perfusion bioreactors [57].
hMSC expansion in rocking motion bioreactors has also been demonstrated by different groups. Nguyen et al. were able to expand these cells for 100 days in bioreactors with a 200 mL working volume, maintaining hMSC viability and chondrogenic and osteogenic differentiation potential. A maximum of (2.64 ± 0.18) × 108 cells were counted on day 40. However, despite a decrease to (8.7 ± 2.1) × 107 cells by day 90, the authors did not observe dead cells through a LIVE/DEAD assay and speculated the decrease in countable cell number to be attributed not to cell death but to hMSC migration to the inside of the microcarrier pores [58]. Da Silva et al. observed some cell deposition in Cellbags, which resulted in stagnated cell growth, and designed an acrylic grid which would allow for the Cellbag to remain in contact with the base for temperature control but would also raise the Cellbag wall, avoiding cell deposits. The authors also verified some deposits at the Cellbag wall due to the microcarriers sticking to it. The adhesion phase was first performed in spinner flasks, then in the modified Cellbags in dynamic conditions, and in static with reduced volume. The latter conditions led to the best overall cell expansion, with a final yield of 2.56 × 108 UCM–hMSCs in 600 mL [59]. The same group then compared the expansion of these cells in the modified Cellbags (600 mL working volume) and 500 mL spinner flasks. Neither platform impacted hMSC tri-lineage differentiation potential nor differently regulated biological systems; however, spinner flask culture was more efficient, both in terms of final cell number and in the time at which the maximum was achieved. Maximum cell yields of (4.65 ± 0.14) × 108 cells in 6 days and 1.32 × 108 cells in 11 days were obtained for the spinner flask and the rocking motion bioreactor, respectively [60].
Timmins et al. have used rocking motion bioreactors for the production of red blood cells (RBCs) from umbilical cord blood (UCB)-derived hHSPCs. By controlling the cell density at regular intervals, the authors obtained an average 2.25 × 108-fold increase in cell number in 33 days—a production averaging 4.5 × 1015 RBCs in a culture of up to 1 L of working volume and allowing to harvest 560 units of RBCs per UCB donation [61].

2.7. Vertical-Wheel Bioreactors

As mentioned in Section 2.1, stirred-tank bioreactors are the gold standard in traditional bioprocessing approaches but are undesirable for stem cell culture due to the high levels of shear stress their agitation mechanism conveys. While most other bioreactor systems already mentioned avoiding the issue by not employing an impeller, this impairs mass transfer and may compromise the homogeneity of the culture. The Vertical-WheelTM bioreactors (VWBRs), introduced by PBS Biotech (Camarillo, California, USA), were designed to provide a homogeneous culture environment while using a more gentle and efficient agitation mechanism (Figure 8) [114]. The vessels contain a large vertical wheel, which format results in both radial and axial agitation. Moreover, the U-shaped bottom of the vessel avoids “dead zones” underneath the impeller, thus limiting cell settling. Overall, this results in a more efficient mixing, allowing for low agitation speeds to be used and, consequently, less shear stress to be conveyed to the cells. Furthermore, the large size of the impeller allows for the dissipation of its rotational energy over a substantial area, thus resulting in narrower gradients of energy dissipation rate, with maximum values of 20–25%, compared to horizontal-blade impellers [114]. These bioreactors can have two different agitation mechanisms: in AirDrive VWBRs, agitation is controlled by bubble sparging, which are captured in specific zones of the vertical wheel, allowing for its motion; in MagDrive VWBRs, agitation is driven by magnetic coupling between magnets present in the vertical impeller and in the base unit. These bioreactors were developed to be single use and are available in various scales, from 100 mL to 80 L (MagDrive) or from 3 L to 500 L (AirDrive), and feature an embedded automatic controller starting from the 3 L units (Figure 8). The characterisation of VWBRs is so far limited, and therefore, no empirical correlations for bioreactor scale-up are yet available, but reports of computational fluid dynamics-based hydrodynamic modelling have already been published [66,114].
hiPSC culture in VWBRs has already been described, culturing the cells as aggregates (with a maximum yield of (7.1 ± 0.7) × 107 cells in a repeated batch approach and (6.1 ± 0.7) × 107 cells using a fed-batch process, both in 7 days and at a 60 mL scale [63]) and attached to vitronectin-coated microcarriers (maximum yield of (1.0 ± 0.1) × 108 cells in 9 days at an 80 mL scale, and (2.6 ± 0.5) × 108 in 8 days using a 300 mL working volume [64]). Notably, the addition of the polysulfated compound dextran sulphate, a staple of the biopharmaceutical industry due to aggregate size control via cell surface charge modulation and anti-apoptotic effect [115,116], improved the aggregate culture about twofold in terms of cell yield, leading to a maximum of (1.4 ± 0.1) × 108 cells in 5 days with repeated batch and (1.26 ± 0.02) × 108 cells in 6 days using a fed-batch process [63]. Borys et al. tested hiPSC expansion in 100 mL VWBR and found normoxic conditions using repeated batch to lead to a higher cell growth than experiments with hypoxia (3%) and/or batch conditions. By performing a low-density inoculation with pre-formed aggregates, they obtained up to (6.3 ± 0.4) × 108 cells in 6 days, and about 2.1 × 1012 cells in 28 days, over the course of four consecutive passages [65]. The same group then optimised the culture protocol, in terms of inoculation (pre-formed aggregates vs. single cell), agitation speed and harvesting enzyme, and exposure time. With the optimised conditions, a maximum of (6.5 ± 0.6) × 108 cells could be obtained, which could be passaged to 500 mL volume vessels [66]. In all cases, the expression of pluripotency markers and differentiation potential of the cells were found to be maintained. In a recent study, Silva et al. have demonstrated cerebellar differentiation of hiPSCs in VWBRs. The dynamic culture system was shown to maintain cell viability for at least 80 days of differentiation as well as to enhance extracellular matrix formation and to activate angiogenesis-related pathways in comparison to the static control [62]. This spontaneous onset of angiogenesis, in particular, is a very promising development since in vitro organoids are generally limited in this regard and necessitate alternative strategies for blood vessel formation [117].
Various studies also describe hMSC expansion in VWBRs. Yuan et al. developed a method for scalable BM–hMSC aggregation [67]. The authors designed thermal responsive poly(N-isporopylacrylamide) (PNIPAM) microcarriers to which cells could attach at 37 °C, and be detached from at the end of expansion by incubation at 23 °C. Following thermal detachment and microcarrier removal from the vessel, the cells would be left to spontaneously aggregate. The authors performed cell expansion, harvesting, and aggregation in both spinner flasks and VWBRs. In the spinner flask, the harvesting resulted in mainly single cells which did not aggregate even after 24 h. Expansion in the VWBRs at a 60 mL scale led to a production of 6.8 × 106 cells in 4 days, which could be harvested in 10 min at 23 °C and could form aggregates, with a comparable diameter and cell viability to an AggreWell-based protocol, as well as with similar immunomodulation and cytokine secretion. Lembong et al. also describe BM–hMSC expansion in VWBRs, using a xeno-free, fed-batch approach. Following optimisation of the cell and microcarrier concentration, as well as the agitation, the fed-batch, and microcarrier addition strategies, and harvesting process (speed, quench hold time, and solution temperature) the authors could obtain 1.8–5.5 × 107 cells across hMSCs of five different donors after 5 days in a 92 mL working volume [70]. Another report of xeno-free UCM– and AT–hMSCs expansion in VWBRs led to the production of (5.3 ± 0.4) × 107 and (3.6 ± 0.7) × 107 cells, respectively, in 7 days and with a 100 mL working volume. Furthermore, the VWBR was established as an economical alternative to T-175 flasks, as a cost analysis estimated a reduction of the process cost per dose, from USD 17,000 to USD 11,100 for UCM–hMSCs and from USD 21,500 to USD 11,100 for AT–hMSCs [68]. Similar conditions were used for extracellular vesicle (EV) production from BM–, AT– and UCM–hMSCs expanded in 100 mL working volume VWBRs. EVs comprise a prospective therapy for a variety of diseases, either by their own characteristics or as drug delivery vehicles. Up to (5.3 ± 5.5) × 107 hMSCs were obtained after the culture (which ranged from 7 to 11 days depending on the cell donor and source). All three cell sources led to EV production in higher amounts when compared to static cultures (averaging 5.7 ± 0.9), with a maximum average of (6.9 ± 1.7) × 109 particles/mL for UCM–hMSCs. The purity of these EVs was also improved and more consistent between runs in comparison to static culture [69]. Finally, BM–hMSCs have also been expanded at a 2.2 L scale, in AirDrive VWBRs. About 6.6 × 108 cells could be obtained after 14 days of culture, with a similar cell concentration to 250 mL STBRs, although with a significantly lower percentage of apoptotic cells, as well as less HLA–DR expression (3% in VWBRs vs. 30% in STBRs). This lower HLA–DR expression, in particular, is promising for the development of allogenic cell therapies [71].

3. Challenges of Single-Use Bioreactor-Based Processes

The various examples of single-use bioreactors presented have shown that these platforms can provide an answer to the limitations of reusable bioreactor systems for the biomanufacturing of stem cells for regenerative medicine applications. In fact, disposable hollow fibre bioreactors have already been used in this context [43], and promising results on stem cell expansion and/or differentiation in other platforms, such as STBRs, rocking motion bioreactors, and VWBRs may lead into clinical trials with stem cells and derivatives produced in these bioreactors in the near future. The choice of bioreactor will depend on various factors, as each bioreactor has a subset of advantages and limitations (summarised in Table 3); however, the overall development of processes with single-use bioreactors also provides some challenges, independently of the platform of choice.
Reusable bioreactors necessitate resistant materials for their components, such as glass and/or stainless steel, in order to prolong their lifetime even under many successive/long cultures and various autoclaving or steaming cycles. The disposable parts of single-use bioreactors can employ less resistant materials, such as polymeric compounds, as they need only to be used for one culture process. However, their sterilisation with γ-radiation and their use under culture conditions can lead to the degradation of these polymers, which then leach to the culture medium. Marghitoiu et al. identified 53 different extractables from four different single-use vessels [118]. One of these, bis(2,4-di-tert-butylphenyl)phosphate (BdtBPP), is of special concern. BdtBPP results from the degradation of tris(2,4-di-tert-butylphenyl)phosphite (TBPP), an agent which is commonly added to polyolefins to protect them from oxidation by high temperatures or ionising radiation. BdtBPP was found to be a very potent inhibitor of cell growth [119,120,121], with a half-maximal effective concentration (EC50) for viable cell density between 0.12 mg/L and 0.73 mg/L across nine different CHO cell lines, while up to 2 mg/L could be extracted from single-use vessels [120]. Notably, as the ageing of single-use vessels leads to a reduction in the leachable compounds, some vessels where cell growth was impaired by the presence of BdtBPP could sustain normal cell growth after some time [122]. Nevertheless, due to the possibility of leaching-mediated impaired cell growth, extensive tests on the vessel extractables and care in the use of compounds such as TBPP are of crucial importance. The lesser resistance of the single-use bioreactors in comparison to reusable systems may also limit the scale at which cultures can be performed—at very high scales, the vessels may not be able to withstand the liquid volume and rupture. While this is not a problem for autologous therapies, especially if high-density cultures can be performed, the establishment of off-the-shelf products may be more difficult.
Single-use bioreactors also present an important sustainability issue. In fact, the disposal of possibly hundreds or thousands of single-use vessels over the lifetime of a process will contribute to a higher footprint since these vessels, due to having harboured expanding cells, are treated as biological waste and cannot be recycled, being incinerated, or sent to landfills. The manufacturing, packaging, sterilisation, and shipping of these bioreactors also pose sustainability constraints, as these steps have to be constantly repeated throughout the process. However, a set of life cycle analyses of monoclonal antibody and adenoviral vaccine production in reusable and single-use systems actually concluded the single-use process to be more environmentally sustainable. In fact, the major environmental impact of traditional systems lies in the sterilisation, specifically, on the water for injection and clean steam requirements. Conversely, the end of life of disposable systems was found not to be significant in comparison to the impact of both their production and of the bioprocess operation. Therefore, overall, single-use bioreactors were considered by the authors a “greener” approach, but their environmental impact can be reduced even further by, for instance, ensuring the bioproduction facility is as close as possible to the site of vessel manufacturing, and by promoting the recycling of any non-contaminated parts, namely, the packages and wrapping [123]. Furthermore, this study focused on traditional biological processes, as such, it still remains unanswered if the same conclusions can be extrapolated to the bioproduction of stem cells with its associated specificities.
The transition to disposable systems is also of economic concern [124,125]. While disposable vessels are less expensive than their reusable counterparts, resulting in a smaller initial investment, the need for new vessels for each bioreactor run may lead to higher running costs throughout the lifetime of the process. The differences in single-use bioreactor process cost will depend on the lower initial investment and higher consumable cost, in addition to other factors such as the time saved in sterilisation cycles and the potential lower risk of contaminated batches. Furthermore, processes with single-use bioreactors may face smaller regulatory hurdles, reducing the time-to-market and, consequently, the pay-back and pay-out times. The evaluation of the most financially attractive process will require a thorough economic analysis. Even with this analysis, the choice will depend on what the final goals are—for instance, to obtain a higher profit in the lifetime of the process or to break even with the initial costs at the earliest opportunity.
Regardless of the type of bioreactor used, the development of a stem cell biomanufacturing process benefits from a quality by design (QbD) framework. This approach allows for the definition of the design space in which the process can operate, allowing for some flexibility in the process while ensuring the final product quality. Furthermore, quality control is shifted upstream in the process timeline—instead of being applied at the product level, the whole process is subjected to quality control, allowing for early detection should problems arise. If the characteristics of each single-use vessel are included as critical process parameters, QbD may allow mitigating the effect of possible vessel-to-vessel variations. QbD is also fuelled by continuous and iterative improvement—as more insight on the process is gathered, it can be modified to account for this new information [126]. Therefore, QbD is an important tool for the development of a robust bioprocess while reducing expenses on product quality control and failed batches and allowing for further steps towards meeting GMP guidelines.

4. Conclusions

Human stem cell-based therapies have gained much traction in recent years. However, the myriad of issues raised by the large-scale manufacturing processes of stem cells and their derivatives—such as the limited knowledge about the complexity of human stem cells; the impact of the dynamic culture environment provided by bioreactors on cell phenotype, viability, or quality; the prohibitive cost of platforms and reagents; the shift in paradigm from cells as a factory to cells as the final product, and the regulatory hurdles associated with this shift—have slowed their transition to the clinic. Furthermore, cell differentiation, which is required in many cases (namely, in all processes involving hPSCs), increases the complexity of the processes and the various studies already performed in 2D may be difficult to translate to a bioreactor environment. Nevertheless, some of these barriers are being breached, and it is already possible to produce clinical-scale numbers of stem cells without compromising their quality. In fact, most reported studies using bioreactors to culture stem cells and derivatives perform evaluations of cell phenotype as well as genomic integrity. However, more comprehensive studies (e.g., proteomic or transcriptomic analysis of static vs. dynamic cultures [62]) are still necessary to fully understand the effect of the dynamic culture microenvironment present in bioreactors on the identity of the generated cells, namely envisaging their clinical use. While earlier reports employed reusable bioreactor systems, the various types of single-use bioreactors here reviewed have also been established as competent platforms to ensure hPSC and hMSC expansion and differentiation. Furthermore, single-use bioreactors reduce the risk of contamination of the final product, thus allowing for a more GMP-compliant process. As processes with single-use systems develop and more insight is gathered on how to answer their limitations, they can be expected to take an important role in the establishment of stem cell products, thus allowing for more steps to be taken towards regenerative medicine being more than just a promise, and Prometheus’s regenerating liver more than just a myth.

Author Contributions

Conceptualisation, D.E.S.N., J.M.S.C., and C.A.V.R.; writing—original draft preparation, D.E.S.N.; writing—review and editing, J.M.S.C. and C.A.V.R. All authors have read and agreed to the published version of the manuscript.

Funding

The authors acknowledge financial support from Fundação para a Ciência e a Tecnologia (FCT), Portugal, and from Programa Operacional Regional de Lisboa 2020 (Project N. 007317) through iBB—Institute for Bioengineering and Biosciences (UIDB/04565/2020). The authors also acknowledge the funding received from the FCT projects “CARDIOWHEEL” (PTDC/EQU-EQU/29653/2017) and “SMART” (PTDC/EQU-EQU/3853/2020) as well as Programa Operacional Regional de Lisboa 2020 through the project PRECISE—Accelerating progress toward the new era of precision medicine (PAC—PRECISE—LISBOA-01-0145-FEDER-016394, SAICTPAC/0021/2015). D.E.S.N. thanks FCT for financial support (PD/BD/128376/2017).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Kaiser, L.R. The future of multihospital systems. Top. Health Care Financ. 1992, 18, 32–45. [Google Scholar] [PubMed]
  2. Power, C.; Rasko, J.E. Whither prometheus’ liver? Greek myth and the science of regeneration. Ann. Intern. Med. 2008, 149, 421–426. [Google Scholar] [CrossRef] [PubMed]
  3. Schneider, M.D. Regenerative medicine: Prometheus unbound. Nature 2004, 432, 451–453. [Google Scholar] [CrossRef] [PubMed]
  4. Thomson, J.A.; Itskovitz-Eldor, J.; Shapiro, S.S.; Waknitz, M.A.; Swiergiel, J.J.; Marshall, V.S.; Jones, J.M. Embryonic stem cell lines derived from human blastocysts. Science 1998, 282, 1145–1147. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Takahashi, K.; Tanabe, K.; Ohnuki, M.; Narita, M.; Ichisaka, T.; Tomoda, K.; Yamanaka, S. Induction of pluripotent stem cells from adult human fibroblasts by defined factors. Cell 2007, 131, 861–872. [Google Scholar] [CrossRef] [Green Version]
  6. Yu, J.; Vodyanik, M.A.; Smuga-Otto, K.; Antosiewicz-Bourget, J.; Frane, J.L.; Tian, S.; Nie, J.; Jonsdottir, G.A.; Ruotti, V.; Stewart, R.; et al. Induced pluripotent stem cell lines derived from human somatic cells. Science 2007, 318, 1917–1920. [Google Scholar] [CrossRef]
  7. Rowe, R.G.; Daley, G.Q. Induced pluripotent stem cells in disease modelling and drug discovery. Nat. Rev. Genet. 2019. [Google Scholar] [CrossRef]
  8. Dame, K.; Ribeiro, A.J. Microengineered systems with iPSC-derived cardiac and hepatic cells to evaluate drug adverse effects. Exp. Biol Med. 2021, 246, 317–331. [Google Scholar] [CrossRef]
  9. Lancaster, M.A.; Huch, M. Disease modelling in human organoids. Dis Model. Mech 2019, 12. [Google Scholar] [CrossRef] [Green Version]
  10. Hass, R.; Kasper, C.; Bohm, S.; Jacobs, R. Different populations and sources of human mesenchymal stem cells (MSC): A comparison of adult and neonatal tissue-derived MSC. Cell Commun. Signal. 2011, 9, 1–14. [Google Scholar] [CrossRef] [Green Version]
  11. Zhao, Q.; Ren, H.; Han, Z. Mesenchymal stem cells: Immunomodulatory capability and clinical potential in immune diseases. J. Cell. Immunother. 2016, 2, 3–20. [Google Scholar] [CrossRef] [Green Version]
  12. Wang, M.; Yuan, Q.; Xie, L. Mesenchymal Stem Cell-Based Immunomodulation: Properties and Clinical Application. Stem Cells Int. 2018, 2018, 3057624. [Google Scholar] [CrossRef]
  13. Gao, F.; Chiu, S.M.; Motan, D.A.; Zhang, Z.; Chen, L.; Ji, H.L.; Tse, H.F.; Fu, Q.L.; Lian, Q. Mesenchymal stem cells and immunomodulation: Current status and future prospects. Cell Death Dis. 2016, 7, e2062. [Google Scholar] [CrossRef] [Green Version]
  14. Han, Y.; Li, X.; Zhang, Y.; Han, Y.; Chang, F.; Ding, J. Mesenchymal Stem Cells for Regenerative Medicine. Cells 2019, 8, 886. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Pittenger, M.F.; Discher, D.E.; Peault, B.M.; Phinney, D.G.; Hare, J.M.; Caplan, A.I. Mesenchymal stem cell perspective: Cell biology to clinical progress. NPJ Regen. Med. 2019, 4, 1–15. [Google Scholar] [CrossRef] [Green Version]
  16. Fitzsimmons, R.E.B.; Mazurek, M.S.; Soos, A.; Simmons, C.A. Mesenchymal Stromal/Stem Cells in Regenerative Medicine and Tissue Engineering. Stem Cells Int. 2018, 2018, 8031718. [Google Scholar] [CrossRef]
  17. Moll, G.; Drzeniek, N.; Kamhieh-Milz, J.; Geissler, S.; Volk, H.D.; Reinke, P. MSC Therapies for COVID-19: Importance of Patient Coagulopathy, Thromboprophylaxis, Cell Product Quality and Mode of Delivery for Treatment Safety and Efficacy. Front. Immunol. 2020, 11, 1091. [Google Scholar] [CrossRef]
  18. Kabat, M.; Bobkov, I.; Kumar, S.; Grumet, M. Trends in mesenchymal stem cell clinical trials 2004-2018: Is efficacy optimal in a narrow dose range? Stem Cells Transl. Med. 2020, 9, 17–27. [Google Scholar] [CrossRef] [Green Version]
  19. Melmed, G.Y.; Pandak, W.M.; Casey, K.; Abraham, B.; Valentine, J.; Schwartz, D.; Awais, D.; Bassan, I.; Lichtiger, S.; Sands, B.; et al. Human Placenta-derived Cells (PDA-001) for the Treatment of Moderate-to-severe Crohn’s Disease: A Phase 1b/2a Study. Inflamm. Bowel Dis. 2015, 21, 1809–1816. [Google Scholar] [CrossRef]
  20. Hess, D.C.; Wechsler, L.R.; Clark, W.M.; Savitz, S.I.; Ford, G.A.; Chiu, D.; Yavagal, D.R.; Uchino, K.; Liebeskind, D.S.; Auchus, A.P.; et al. Safety and efficacy of multipotent adult progenitor cells in acute ischaemic stroke (MASTERS): A randomised, double-blind, placebo-controlled, phase 2 trial. Lancet Neurol. 2017, 16, 360–368. [Google Scholar] [CrossRef]
  21. Zweigerdt, R. Large scale production of stem cells and their derivatives. Eng. Stem Cells 2009, 114, 201–235. [Google Scholar] [CrossRef]
  22. Baker, B.M.; Chen, C.S. Deconstructing the third dimension: How 3D culture microenvironments alter cellular cues. J. Cell Sci. 2012, 125, 3015–3024. [Google Scholar] [CrossRef] [Green Version]
  23. Krtolica, A.; Genbacev, O.; Escobedo, C.; Zdravkovic, T.; Nordstrom, A.; Vabuena, D.; Nath, A.; Simon, C.; Mostov, K.; Fisher, S.J. Disruption of apical-basal polarity of human embryonic stem cells enhances hematoendothelial differentiation. Stem Cells 2007, 25, 2215–2223. [Google Scholar] [CrossRef]
  24. Schmideder, A.; Weuster-Botz, D. High-performance recombinant protein production with Escherichia coli in continuously operated cascades of stirred-tank reactors. J. Ind. Microbiol. Biotechnol. 2017, 44, 1021–1029. [Google Scholar] [CrossRef]
  25. van Lier, F.L.; van den End, E.J.; de Gooijer, C.D.; Vlak, J.M.; Tramper, J. Continuous production of baculovirus in a cascade of insect-cell reactors. Appl. Microbiol. Biotechnol. 1990, 33, 43–47. [Google Scholar] [CrossRef]
  26. Raven, N.; Rasche, S.; Kuehn, C.; Anderlei, T.; Klockner, W.; Schuster, F.; Henquet, M.; Bosch, D.; Buchs, J.; Fischer, R.; et al. Scaled-up manufacturing of recombinant antibodies produced by plant cells in a 200-L orbitally-shaken disposable bioreactor. Biotechnol. Bioeng. 2015, 112, 308–321. [Google Scholar] [CrossRef]
  27. Velez-Suberbie, M.L.; Tarrant, R.D.; Tait, A.S.; Spencer, D.I.; Bracewell, D.G. Impact of aeration strategy on CHO cell performance during antibody production. Biotechnol. Prog. 2013, 29, 116–126. [Google Scholar] [CrossRef]
  28. Rodrigues, C.A.; Fernandes, T.G.; Diogo, M.M.; da Silva, C.L.; Cabral, J.M. Stem cell cultivation in bioreactors. Biotechnol. Adv. 2011, 29, 815–829. [Google Scholar] [CrossRef] [PubMed]
  29. Kropp, C.; Kempf, H.; Halloin, C.; Robles-Diaz, D.; Franke, A.; Scheper, T.; Kinast, K.; Knorpp, T.; Joos, T.O.; Haverich, A.; et al. Impact of Feeding Strategies on the Scalable Expansion of Human Pluripotent Stem Cells in Single-Use Stirred Tank Bioreactors. Stem Cells Transl. Med. 2016, 5, 1289–1301. [Google Scholar] [CrossRef] [Green Version]
  30. Kwok, C.K.; Ueda, Y.; Kadari, A.; Gunther, K.; Ergun, S.; Heron, A.; Schnitzler, A.C.; Rook, M.; Edenhofer, F. Scalable stirred suspension culture for the generation of billions of human induced pluripotent stem cells using single-use bioreactors. J. Tissue Eng. Regen. Med. 2018, 12, e1076–e1087. [Google Scholar] [CrossRef] [Green Version]
  31. Rafiq, Q.A.; Hanga, M.P.; Heathman, T.R.J.; Coopman, K.; Nienow, A.W.; Williams, D.J.; Hewitt, C.J. Process development of human multipotent stromal cell microcarrier culture using an automated high-throughput microbioreactor. Biotechnol. Bioeng. 2017, 114, 2253–2266. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Rotondi, M.; Grace, N.; Betts, J.; Bargh, N.; Costariol, E.; Zoro, B.; Hewitt, C.J.; Nienow, A.W.; Rafiq, Q.A. Design and development of a new ambr250(R) bioreactor vessel for improved cell and gene therapy applications. Biotechnol. Lett. 2021. [Google Scholar] [CrossRef]
  33. Cunha, B.; Aguiar, T.; Carvalho, S.B.; Silva, M.M.; Gomes, R.A.; Carrondo, M.J.T.; Gomes-Alves, P.; Peixoto, C.; Serra, M.; Alves, P.M. Bioprocess integration for human mesenchymal stem cells: From up to downstream processing scale-up to cell proteome characterization. J. Biotechnol. 2017, 248, 87–98. [Google Scholar] [CrossRef]
  34. Schirmaier, C.; Jossen, V.; Kaiser, S.C.; Jüngerkes, F.; Brill, S.; Safavi-Nab, A.; Siehoff, A.; van den Bos, C.; Eibl, D.; Eibl, R. Scale-up of adipose tissue-derived mesenchymal stem cell production in stirred single-use bioreactors under low-serum conditions. Eng. Life Sci. 2014, 14, 292–303. [Google Scholar] [CrossRef]
  35. Grein, T.A.; Leber, J.; Blumenstock, M.; Petry, F.; Weidner, T.; Salzig, D.; Czermak, P. Multiphase mixing characteristics in a microcarrier-based stirred tank bioreactor suitable for human mesenchymal stem cell expansion. Process. Biochem. 2016, 51, 1109–1119. [Google Scholar] [CrossRef]
  36. Lawson, T.; Kehoe, D.E.; Schnitzler, A.C.; Rapiejko, P.J.; Der, K.A.; Philbrick, K.; Punreddy, S.; Rigby, S.; Smith, R.; Feng, Q. Process development for expansion of human mesenchymal stromal cells in a 50 L single-use stirred tank bioreactor. Biochem. Eng. J. 2017, 120, 49–62. [Google Scholar] [CrossRef]
  37. Ratcliffe, E.; Glen, K.E.; Workman, V.L.; Stacey, A.J.; Thomas, R.J. A novel automated bioreactor for scalable process optimisation of haematopoietic stem cell culture. J. Biotechnol. 2012, 161, 387–390. [Google Scholar] [CrossRef] [Green Version]
  38. Weber, C.; Pohl, S.; Portner, R.; Wallrapp, C.; Kassem, M.; Geigle, P.; Czermak, P. Cultivation and Differentiation of Encapsulated hMSC-TERT in a Disposable Small-Scale Syringe-Like Fixed Bed Reactor. Open Biomed. Eng. J. 2007, 1, 64–70. [Google Scholar] [CrossRef]
  39. Weber, C.; Freimark, D.; Pörtner, R.; Pino-Grace, P.; Pohl, S.; Wallrapp, C.; Geigle, P.; Czermak, P. Expansion of human mesenchymal stem cells in a fixed-bed bioreactor system based on non-porous glass carrier–part A: Inoculation, cultivation, and cell harvest procedures. Int. J. Artif. Organs. 2010, 33, 512–525. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  40. Mizukami, A.; Orellana, M.D.; Caruso, S.R.; de Lima Prata, K.; Covas, D.T.; Swiech, K. Efficient expansion of mesenchymal stromal cells in a disposable fixed bed culture system. Biotechnol. Prog. 2013, 29, 568–572. [Google Scholar] [CrossRef]
  41. Roberts, I.; Baila, S.; Rice, R.B.; Janssens, M.E.; Nguyen, K.; Moens, N.; Ruban, L.; Hernandez, D.; Coffey, P.; Mason, C. Scale-up of human embryonic stem cell culture using a hollow fibre bioreactor. Biotechnol. Lett. 2012, 34, 2307–2315. [Google Scholar] [CrossRef]
  42. Paccola Mesquita, F.C.; Hochman-Mendez, C.; Morrissey, J.; Sampaio, L.C.; Taylor, D.A. Laminin as a Potent Substrate for Large-Scale Expansion of Human Induced Pluripotent Stem Cells in a Closed Cell Expansion System. Stem Cells Int. 2019, 2019, 9704945. [Google Scholar] [CrossRef] [Green Version]
  43. Tirughana, R.; Metz, M.Z.; Li, Z.; Hall, C.; Hsu, D.; Beltzer, J.; Annala, A.J.; Oganesyan, D.; Gutova, M.; Aboody, K.S. GMP Production and Scale-Up of Adherent Neural Stem Cells with a Quantum Cell Expansion System. Mol. Ther. Methods Clin. Dev. 2018, 10, 48–56. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Russell, A.L.; Lefavor, R.C.; Zubair, A.C. Characterization and cost-benefit analysis of automated bioreactor-expanded mesenchymal stem cells for clinical applications. Transfusion 2018, 58, 2374–2382. [Google Scholar] [CrossRef] [PubMed]
  45. Haack-Sørensen, M.; Follin, B.; Juhl, M.; Brorsen, S.K.; Søndergaard, R.H.; Kastrup, J.; Ekblond, A. Culture expansion of adipose derived stromal cells. A closed automated Quantum Cell Expansion System compared with manual flask-based culture. J. Transl. Med. 2016, 14, 1–11. [Google Scholar] [CrossRef] [Green Version]
  46. Mennan, C.; Garcia, J.; Roberts, S.; Hulme, C.; Wright, K. A comprehensive characterisation of large-scale expanded human bone marrow and umbilical cord mesenchymal stem cells. Stem Cell Res. Ther. 2019, 10, 1–15. [Google Scholar] [CrossRef] [Green Version]
  47. Mizukami, A.; Chilima, T.D.P.; Orellana, M.D.; Neto, M.A.; Covas, D.T.; Farid, S.S.; Swiech, K. Technologies for large-scale umbilical cord-derived MSC expansion: Experimental performance and cost of goods analysis. Biochem. Eng. J. 2018, 135, 36–48. [Google Scholar] [CrossRef]
  48. Mizukami, A.; de Abreu Neto, M.S.; Moreira, F.; Fernandes-Platzgummer, A.; Huang, Y.F.; Milligan, W.; Cabral, J.M.S.; da Silva, C.L.; Covas, D.T.; Swiech, K. A Fully-Closed and Automated Hollow Fiber Bioreactor for Clinical-Grade Manufacturing of Human Mesenchymal Stem/Stromal Cells. Stem Cell Rev. Rep. 2018, 14, 141–143. [Google Scholar] [CrossRef]
  49. Lambrechts, T.; Papantoniou, I.; Rice, B.; Schrooten, J.; Luyten, F.P.; Aerts, J.M. Large-scale progenitor cell expansion for multiple donors in a monitored hollow fibre bioreactor. Cytotherapy 2016, 18, 1219–1233. [Google Scholar] [CrossRef] [PubMed]
  50. Vymetalova, L.; Kucirkova, T.; Knopfova, L.; Pospisilova, V.; Kasko, T.; Lejdarova, H.; Makaturova, E.; Kuglik, P.; Oralova, V.; Matalova, E.; et al. Large-Scale Automated Hollow-Fiber Bioreactor Expansion of Umbilical Cord-Derived Human Mesenchymal Stromal Cells for Neurological Disorders. Neurochem. Res. 2020, 45, 204–214. [Google Scholar] [CrossRef]
  51. Haack-Sørensen, M.; Juhl, M.; Follin, B.; Harary Søndergaard, R.; Kirchhoff, M.; Kastrup, J.; Ekblond, A. Development of large-scale manufacturing of adipose-derived stromal cells for clinical applications using bioreactors and human platelet lysate. Scand. J. Clin. Lab. Investig. 2018, 78, 293–300. [Google Scholar] [CrossRef] [PubMed]
  52. Nold, P.; Brendel, C.; Neubauer, A.; Bein, G.; Hackstein, H. Good manufacturing practice-compliant animal-free expansion of human bone marrow derived mesenchymal stroma cells in a closed hollow-fiber-based bioreactor. Biochem. Biophys. Res. Commun. 2013, 430, 325–330. [Google Scholar] [CrossRef] [PubMed]
  53. Chiang, M.C.; Lin, H.; Cheng, Y.C.; Yen, C.H.; Huang, R.N.; Lin, K.H. Beta-adrenoceptor pathway enhances mitochondrial function in human neural stem cells via rotary cell culture system. J. Neurosci. Methods 2012, 207, 130–136. [Google Scholar] [CrossRef]
  54. Sakai, S.; Mishima, H.; Ishii, T.; Akaogi, H.; Yoshioka, T.; Ohyabu, Y.; Chang, F.; Ochiai, N.; Uemura, T. Rotating three-dimensional dynamic culture of adult human bone marrow-derived cells for tissue engineering of hyaline cartilage. J. Orthop. Res. 2009, 27, 517–521. [Google Scholar] [CrossRef]
  55. Neumann, A.; Lavrentieva, A.; Heilkenbrinker, A.; Loenne, M.; Kasper, C. Characterization and Application of a Disposable Rotating Bed Bioreactor for Mesenchymal Stem Cell Expansion. Bioengineering 2014, 1, 231–245. [Google Scholar] [CrossRef] [Green Version]
  56. Reichardt, A.; Polchow, B.; Shakibaei, M.; Henrich, W.; Hetzer, R.; Lueders, C. Large scale expansion of human umbilical cord cells in a rotating bed system bioreactor for cardiovascular tissue engineering applications. Open Biomed. Eng. J. 2013, 7, 50–61. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  57. Davis, B.M.; Loghin, E.R.; Conway, K.R.; Zhang, X. Automated Closed-System Expansion of Pluripotent Stem Cell Aggregates in a Rocking-Motion Bioreactor. SLAS Technol. 2018, 23, 364–373. [Google Scholar] [CrossRef] [Green Version]
  58. Nguyen, L.; Bang, S.; Noh, I. Tissue Regeneration of Human Mesenchymal Stem Cells on Porous Gelatin Micro-Carriers by Long-Term Dynamic In Vitro Culture. Tissue Eng. Regen. Med. 2019, 16, 19–28. [Google Scholar] [CrossRef]
  59. da Silva, J.d.S.; Mizukami, A.; Gil, L.V.G.; de Campos, J.V.; Assis, O.B.; Covas, D.T.; Swiech, K.; Suazo, C.A.T. Improving wave-induced motion bioreactor performance for human mesenchymal stromal cell expansion. Process Biochem. 2019, 84, 143–152. [Google Scholar] [CrossRef]
  60. da Silva, J.d.S.; Severino, P.; Wodewotzky, T.I.; Covas, D.T.; Swiech, K.; Marti, L.C.; Suazo, C.A.T. Mesenchymal stromal cells maintain the major quality attributes when expanded in different bioreactor systems. Biochem. Eng. J. 2020, 161, 107693. [Google Scholar] [CrossRef]
  61. Timmins, N.E.; Athanasas, S.; Gunther, M.; Buntine, P.; Nielsen, L.K. Ultra-high-yield manufacture of red blood cells from hematopoietic stem cells. Tissue Eng. Part C Methods 2011, 17, 1131–1137. [Google Scholar] [CrossRef] [PubMed]
  62. Silva, T.P.; Sousa-Luis, R.; Fernandes, T.G.; Bekman, E.P.; Rodrigues, C.A.V.; Vaz, S.H.; Moreira, L.M.; Hashimura, Y.; Jung, S.; Lee, B.; et al. Transcriptome profiling of human pluripotent stem cell-derived cerebellar organoids reveals faster commitment under dynamic conditions. Biotechnol. Bioeng. 2021. [Google Scholar] [CrossRef]
  63. Nogueira, D.E.S.; Rodrigues, C.A.V.; Carvalho, M.S.; Miranda, C.C.; Hashimura, Y.; Jung, S.; Lee, B.; Cabral, J.M.S. Strategies for the expansion of human induced pluripotent stem cells as aggregates in single-use Vertical-Wheel bioreactors. J. Biol. Eng. 2019, 13, 1–14. [Google Scholar] [CrossRef] [Green Version]
  64. Rodrigues, C.A.V.; Silva, T.P.; Nogueira, D.E.S.; Fernandes, T.G.; Hashimura, Y.; Wesselschmidt, R.; Diogo, M.M.; Lee, B.; Cabral, J.M.S. Scalable culture of human induced pluripotent cells on microcarriers under xeno-free conditions using single-use vertical-wheel (TM) bioreactors. J. Chem. Technol. Biotechnol. 2018, 93, 3597–3606. [Google Scholar] [CrossRef]
  65. Borys, B.S.; So, T.; Colter, J.; Dang, T.; Roberts, E.L.; Revay, T.; Larijani, L.; Krawetz, R.; Lewis, I.; Argiropoulos, B.; et al. Optimized serial expansion of human induced pluripotent stem cells using low-density inoculation to generate clinically relevant quantities in vertical-wheel bioreactors. Stem Cells Transl. Med. 2020, 9, 1036–1052. [Google Scholar] [CrossRef] [PubMed]
  66. Borys, B.S.; Dang, T.; So, T.; Rohani, L.; Revay, T.; Walsh, T.; Thompson, M.; Argiropoulos, B.; Rancourt, D.E.; Jung, S.; et al. Overcoming bioprocess bottlenecks in the large-scale expansion of high-quality hiPSC aggregates in vertical-wheel stirred suspension bioreactors. Stem Cell Res. Ther. 2021, 12, 1–19. [Google Scholar] [CrossRef]
  67. Yuan, X.; Tsai, A.C.; Farrance, I.; Rowley, J.; Ma, T. Aggregation of Culture Expanded Human Mesenchymal Stem Cells in Microcarrier-based Bioreactor. Biochem. Eng. J. 2018, 131, 39–46. [Google Scholar] [CrossRef]
  68. de Sousa Pinto, D.; Bandeiras, C.; de Almeida Fuzeta, M.; Rodrigues, C.A.V.; Jung, S.; Hashimura, Y.; Tseng, R.J.; Milligan, W.; Lee, B.; Ferreira, F.C.; et al. Scalable Manufacturing of Human Mesenchymal Stromal Cells in the Vertical-Wheel Bioreactor System: An Experimental and Economic Approach. Biotechnol. J. 2019, 14, e1800716. [Google Scholar] [CrossRef]
  69. de Almeida Fuzeta, M.; Bernardes, N.; Oliveira, F.D.; Costa, A.C.; Fernandes-Platzgummer, A.; Farinha, J.P.; Rodrigues, C.A.V.; Jung, S.; Tseng, R.J.; Milligan, W.; et al. Scalable Production of Human Mesenchymal Stromal Cell-Derived Extracellular Vesicles Under Serum-/Xeno-Free Conditions in a Microcarrier-Based Bioreactor Culture System. Front. Cell Dev. Biol. 2020, 8, 553444. [Google Scholar] [CrossRef]
  70. Lembong, J.; Kirian, R.; Takacs, J.D.; Olsen, T.R.; Lock, L.T.; Rowley, J.A.; Ahsan, T. Bioreactor Parameters for Microcarrier-Based Human MSC Expansion under Xeno-Free Conditions in a Vertical-Wheel System. Bioengineering 2020, 7. [Google Scholar] [CrossRef]
  71. Sousa, M.F.; Silva, M.M.; Giroux, D.; Hashimura, Y.; Wesselschmidt, R.; Lee, B.; Roldao, A.; Carrondo, M.J.; Alves, P.M.; Serra, M. Production of oncolytic adenovirus and human mesenchymal stem cells in a single-use, Vertical-Wheel bioreactor system: Impact of bioreactor design on performance of microcarrier-based cell culture processes. Biotechnol. Prog. 2015, 31, 1600–1612. [Google Scholar] [CrossRef] [PubMed]
  72. Stolberg, S.; McCloskey, K.E. Can shear stress direct stem cell fate? Biotechnol. Prog. 2009, 25, 10–19. [Google Scholar] [CrossRef] [PubMed]
  73. Earls, J.K.; Jin, S.; Ye, K. Mechanobiology of human pluripotent stem cells. Tissue Eng. Part B Rev. 2013, 19, 420–430. [Google Scholar] [CrossRef] [PubMed]
  74. Leung, H.W.; Chen, A.; Choo, A.B.; Reuveny, S.; Oh, S.K. Agitation can induce differentiation of human pluripotent stem cells in microcarrier cultures. Tissue Eng. Part C Methods 2011, 17, 165–172. [Google Scholar] [CrossRef]
  75. Yourek, G.; McCormick, S.M.; Mao, J.J.; Reilly, G.C. Shear stress induces osteogenic differentiation of human mesenchymal stem cells. Regen. Med. 2010, 5, 713–724. [Google Scholar] [CrossRef] [Green Version]
  76. Özbek, B.; Gayik, S. The studies on the oxygen mass transfer coefficient in a bioreactor. Process Biochem. 2001, 36, 729–741. [Google Scholar] [CrossRef]
  77. Nienow, A.W. Scale-up, Stirred Tank Reactors. Encyclopedia of Industrial Biotechnology: Bioprocess., Bioseparation, and Cell Technology; John Wiley & Sons: Hoboken, NJ, USA, 2009; pp. 1–38. [Google Scholar] [CrossRef]
  78. Liu, Y.; Wang, Z.-J.; Xia, J.-Y.; Haringa, C.; Liu, Y.-P.; Chu, J.; Zhuang, Y.-P.; Zhang, S.-L. Application of Euler-Lagrange CFD for quantitative evaluating the effect of shear force on Carthamus tinctorius L. cell in a stirred tank bioreactor. Biochem. Eng. J. 2016, 114, 209–217. [Google Scholar] [CrossRef]
  79. Halloin, C.; Schwanke, K.; Lobel, W.; Franke, A.; Szepes, M.; Biswanath, S.; Wunderlich, S.; Merkert, S.; Weber, N.; Osten, F.; et al. Continuous WNT Control Enables Advanced hPSC Cardiac Processing and Prognostic Surface Marker Identification in Chemically Defined Suspension Culture. Stem Cell Rep. 2019, 13, 366–379. [Google Scholar] [CrossRef] [Green Version]
  80. Watanabe, Y.; Shimada, Y.; Sugihara, A.; Tominaga, Y. Enzymatic conversion of waste edible oil to biodiesel fuel in a fixed-bed bioreactor. J. Am. Oil. Chem. Soc. 2001, 78, 703–707. [Google Scholar] [CrossRef]
  81. Salum, T.F.C.; Villeneuve, P.; Barea, B.; Yamamoto, C.I.; Côcco, L.C.; Mitchell, D.A.; Krieger, N. Synthesis of biodiesel in column fixed-bed bioreactor using the fermented solid produced by Burkholderia cepacia LTEB11. Process Biochem. 2010, 45, 1348–1354. [Google Scholar] [CrossRef]
  82. Chang, J.-S.; Lee, K.-S.; Lin, P.-J. Biohydrogen production with fixed-bed bioreactors. Int. J. Hydrogen Energy 2002, 27, 1167–1174. [Google Scholar] [CrossRef]
  83. Kim, K.; Logan, B.E. Fixed-bed bioreactor treating perchlorate-contaminated waters. Environ. Eng. Sci 2000, 17, 257–265. [Google Scholar] [CrossRef]
  84. Chen, B.-Y.; Chen, S.-Y.; Chang, J.-S. Immobilized cell fixed-bed bioreactor for wastewater decolorization. Process Biochem. 2005, 40, 3434–3440. [Google Scholar] [CrossRef]
  85. Rajendran, R.; Lingala, R.; Vuppu, S.K.; Bandi, B.O.; Manickam, E.; Macherla, S.R.; Dubois, S.; Havelange, N.; Maithal, K. Assessment of packed bed bioreactor systems in the production of viral vaccines. AMB Express 2014, 4, 1–7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  86. Valkama, A.J.; Leinonen, H.M.; Lipponen, E.M.; Turkki, V.; Malinen, J.; Heikura, T.; Yla-Herttuala, S.; Lesch, H.P. Optimization of lentiviral vector production for scale-up in fixed-bed bioreactor. Gene Ther. 2018, 25, 39–46. [Google Scholar] [CrossRef] [Green Version]
  87. Powers, A.D.; Piras, B.A.; Clark, R.K.; Lockey, T.D.; Meagher, M.M. Development and Optimization of AAV hFIX Particles by Transient Transfection in an iCELLis((R)) Fixed-Bed Bioreactor. Hum. Gene Ther. Methods 2016, 27, 112–121. [Google Scholar] [CrossRef]
  88. Meissner, P.; Schroder, B.; Herfurth, C.; Biselli, M. Development of a fixed bed bioreactor for the expansion of human hematopoietic progenitor cells. Cytotechnology 1999, 30, 227–234. [Google Scholar] [CrossRef]
  89. Simonsen, J.L.; Rosada, C.; Serakinci, N.; Justesen, J.; Stenderup, K.; Rattan, S.I.; Jensen, T.G.; Kassem, M. Telomerase expression extends the proliferative life-span and maintains the osteogenic potential of human bone marrow stromal cells. Nat. Biotechnol. 2002, 20, 592–596. [Google Scholar] [CrossRef]
  90. Barckhausen, C.; Rice, B.; Baila, S.; Sensebe, L.; Schrezenmeier, H.; Nold, P.; Hackstein, H.; Rojewski, M.T. GMP-Compliant Expansion of Clinical-Grade Human Mesenchymal Stromal/Stem Cells Using a Closed Hollow Fiber Bioreactor. Methods Mol. Biol. 2016, 1416, 389–412. [Google Scholar] [CrossRef]
  91. MacDonald, J.M.; Wolfe, S.P.; Roy-Chowdhury, I.; Kubota, H.; Reid, L.M. Effect of flow configuration and membrane characteristics on membrane fouling in a novel multicoaxial hollow-fiber bioartificial liver. Ann. N. Y. Acad. Sci. 2001, 944, 334–343. [Google Scholar] [CrossRef] [PubMed]
  92. Tapia, F.; Vogel, T.; Genzel, Y.; Behrendt, I.; Hirschel, M.; Gangemi, J.D.; Reichl, U. Production of high-titer human influenza A virus with adherent and suspension MDCK cells cultured in a single-use hollow fiber bioreactor. Vaccine 2014, 32, 1003–1011. [Google Scholar] [CrossRef] [PubMed]
  93. Yazaki, P.J.; Shively, L.; Clark, C.; Cheung, C.-W.; Le, W.; Szpikowska, B.; Shively, J.E.; Raubitschek, A.A.; Wu, A.M. Mammalian expression and hollow fiber bioreactor production of recombinant anti-CEA diabody and minibody for clinical applications. J. Immunol. Methods 2001, 253, 195–208. [Google Scholar] [CrossRef]
  94. Jardin, B.A.; Zhao, Y.; Selvaraj, M.; Montes, J.; Tran, R.; Prakash, S.; Elias, C.B. Expression of SEAP (secreted alkaline phosphatase) by baculovirus mediated transduction of HEK 293 cells in a hollow fiber bioreactor system. J. Biotechnol. 2008, 135, 272–280. [Google Scholar] [CrossRef] [PubMed]
  95. Pankhania, M.; Stephenson, T.; Semmens, M.J. Hollow fibre bioreactor for wastewater treatment using bubbleless membrane aeration. Water Res. 1994, 28, 2233–2236. [Google Scholar] [CrossRef]
  96. Gimenez, J.B.; Robles, A.; Carretero, L.; Duran, F.; Ruano, M.V.; Gatti, M.N.; Ribes, J.; Ferrer, J.; Seco, A. Experimental study of the anaerobic urban wastewater treatment in a submerged hollow-fibre membrane bioreactor at pilot scale. Bioresour. Technol. 2011, 102, 8799–8806. [Google Scholar] [CrossRef]
  97. Wang, Y.-z.; Zhao, Z.-p.; Li, M.-f.; Chen, Y.-z.; Liu, W.-f. Development of a hollow fiber membrane micro-reactor for biocatalytic production of formate from CO2. J. Membr. Sci. 2016, 514, 44–52. [Google Scholar] [CrossRef]
  98. Krastanov, A.; Blazheva, D.; Stanchev, V. Sucrose conversion into palatinose with immobilized Serratia plymuthica cells in a hollow-fibre bioreactor. Process Biochem. 2007, 42, 1655–1659. [Google Scholar] [CrossRef]
  99. Bieback, K.; Fernandez-Munoz, B.; Pati, S.; Schafer, R. Gaps in the knowledge of human platelet lysate as a cell culture supplement for cell therapy: A joint publication from the AABB and the International Society for Cell & Gene Therapy. Transfusion 2019, 59, 3448–3460. [Google Scholar] [CrossRef] [Green Version]
  100. Wnorowski, A.; Sharma, A.; Chen, H.; Wu, H.; Shao, N.Y.; Sayed, N.; Liu, C.; Countryman, S.; Stodieck, L.S.; Rubins, K.H.; et al. Effects of Spaceflight on Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Structure and Function. Stem Cell Rep. 2019, 13, 960–969. [Google Scholar] [CrossRef] [Green Version]
  101. Lelkes, P.I.; Galvan, D.L.; Hayman, G.T.; Goodwin, T.J.; Chatman, D.Y.; Cherian, S.; Garcia, R.M.; Unsworth, B.R. Simulated microgravity conditions enhance differentiation of cultured PC12 cells towards the neuroendocrine phenotype. In Vitro Cell Dev. Biol. Anim. 1998, 34, 316–325. [Google Scholar] [CrossRef]
  102. Tsao, Y.D.; Goodwin, T.J.; Wolf, D.A.; Spaulding, G.F. Responses of gravity level variations on the NASA/JSC bioreactor system. Physiologist 1992, 35, S49–S50. [Google Scholar] [PubMed]
  103. Hammond, T.G.; Hammond, J.M. Optimized suspension culture: The rotating-wall vessel. Am. J. Physiol. Ren. Physiol. 2001, 281, F12–F25. [Google Scholar] [CrossRef] [PubMed]
  104. Cowger, N.L.; O’Connor, K.C.; Hammond, T.G.; Lacks, D.J.; Navar, G.L. Characterization of bimodal cell death of insect cells in a rotating-wall vessel and shaker flask. Biotechnol. Bioeng. 1999, 64, 14–26. [Google Scholar] [CrossRef] [Green Version]
  105. Abdella, A.; Mazeed, T.E.-S.; El-Baz, A.F.; Yang, S.-T. Production of β-glucosidase from wheat bran and glycerol by Aspergillus niger in stirred tank and rotating fibrous bed bioreactors. Process Biochem. 2016, 51, 1331–1337. [Google Scholar] [CrossRef]
  106. Lan, T.Q.; Wei, D.; Yang, S.T.; Liu, X. Enhanced cellulase production by Trichoderma viride in a rotating fibrous bed bioreactor. Bioresour. Technol. 2013, 133, 175–182. [Google Scholar] [CrossRef] [PubMed]
  107. Pourakbar, M.; Moussavi, G.; Yaghmaeian, K. Enhanced biodegradation of phenol in a novel cyclic activated sludge integrated with a rotating bed bioreactor in anoxic and peroxidase-mediated conditions. RSC Advances 2018, 8, 6293–6305. [Google Scholar] [CrossRef] [Green Version]
  108. Jafari, S.J.; Moussavi, G.; Yaghmaeian, K. High-rate biological denitrification in the cyclic rotating-bed biological reactor: Effect of COD/NO3(-), nitrate concentration and salinity and the phylogenetic analysis of denitrifiers. Bioresour. Technol. 2015, 197, 482–488. [Google Scholar] [CrossRef] [PubMed]
  109. Suck, K.; Behr, L.; Fischer, M.; Hoffmeister, H.; van Griensven, M.; Stahl, F.; Scheper, T.; Kasper, C. Cultivation of MC3T3-E1 cells on a newly developed material (Sponceram) using a rotating bed system bioreactor. J. Biomed. Mater. Res. Part A 2007, 80, 268–275. [Google Scholar] [CrossRef]
  110. Singh, V. Disposable bioreactor for cell culture using wave-induced agitation. Cytotechnology 1999, 30, 149–158. [Google Scholar] [CrossRef] [PubMed]
  111. Kalmbach, A.; Bordas, R.; Oncul, A.A.; Thevenin, D.; Genzel, Y.; Reichl, U. Experimental characterization of flow conditions in 2- and 20-L bioreactors with wave-induced motion. Biotechnol. Prog. 2011, 27, 402–409. [Google Scholar] [CrossRef]
  112. Marsh, D.T.J.; Lye, G.J.; Micheletti, M.; Odeleye, A.O.O.; Ducci, A.; Osborne, M.D. Fluid dynamic characterization of a laboratory scale rocked bag bioreactor. AIChE J. 2017, 63, 4177–4187. [Google Scholar] [CrossRef] [Green Version]
  113. Zhan, C.; Hagrot, E.; Brandt, L.; Chotteau, V. Study of hydrodynamics in wave bioreactors by computational fluid dynamics reveals a resonance phenomenon. Chem. Eng. Sci. 2019, 193, 53–65. [Google Scholar] [CrossRef]
  114. Croughan, M.S.; Giroux, D.; Fang, D.; Lee, B. Novel Single-Use Bioreactors for Scale-Up of Anchorage-Dependent Cell Manufacturing for Cell Therapies In Stem Cell Manufacturing; da Silva, C.L., Chase, L.G., Diogo, M.M., Eds.; Elsevier: Cambridge, UK, 2016; pp. 105–139. [Google Scholar] [CrossRef]
  115. Dee, K.U.; Shuler, M.L.; Wood, H.A. Inducing single-cell suspension of BTI-TN5B1-4 insect cells: I. The use of sulfated polyanions to prevent cell aggregation and enhance recombinant protein production. Biotechnol. Bioeng. 1997, 54, 191–205. [Google Scholar] [CrossRef]
  116. Zanghi, J.A.; Renner, W.A.; Bailey, J.E.; Fussenegger, M. The growth factor inhibitor suramin reduces apoptosis and cell aggregation in protein-free CHO cell batch cultures. Biotechnol. Prog. 2000, 16, 319–325. [Google Scholar] [CrossRef] [PubMed]
  117. Kim, J.J.; Hou, L.; Huang, N.F. Vascularization of three-dimensional engineered tissues for regenerative medicine applications. Acta Biomater 2016, 41, 17–26. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  118. Marghitoiu, L.; Liu, J.; Lee, H.; Perez, L.; Fujimori, K.; Ronk, M.; Hammond, M.R.; Nunn, H.; Lower, A.; Rogers, G.; et al. Extractables analysis of single-use flexible plastic biocontainers. PDA J. Pharm. Sci. Technol. 2015, 69, 49–58. [Google Scholar] [CrossRef]
  119. Hammond, M.; Marghitoiu, L.; Lee, H.; Perez, L.; Rogers, G.; Nashed-Samuel, Y.; Nunn, H.; Kline, S. A cytotoxic leachable compound from single-use bioprocess equipment that causes poor cell growth performance. Biotechnol. Prog. 2014, 30, 332–337. [Google Scholar] [CrossRef]
  120. Hammond, M.; Nunn, H.; Rogers, G.; Lee, H.; Marghitoiu, A.L.; Perez, L.; Nashed-Samuel, Y.; Anderson, C.; Vandiver, M.; Kline, S. Identification of a leachable compound detrimental to cell growth in single-use bioprocess containers. PDA J. Pharm. Sci. Technol. 2013, 67, 123–134. [Google Scholar] [CrossRef]
  121. Liu, J.; Kennedy, J.H.; Ronk, M.; Marghitoiu, L.; Lee, H.; Nashed-Samuel, Y. Ambient analysis of leachable compounds from single-use bioreactors with desorption electrospray ionization time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 2014, 28, 2285–2291. [Google Scholar] [CrossRef] [PubMed]
  122. Jurkiewicz, E.; Husemann, U.; Greller, G.; Barbaroux, M.; Fenge, C. Verification of a new biocompatible single-use film formulation with optimized additive content for multiple bioprocess applications. Biotechnol. Prog. 2014, 30, 1171–1176. [Google Scholar] [CrossRef] [Green Version]
  123. Pietrzykowski, M.; Flanagan, W.; Pizzi, V.; Brown, A.; Sinclair, A.; Monge, M. An environmental life cycle assessment comparison of single-use and conventional process technology for the production of monoclonal antibodies. J. Clean. Prod. 2013, 41, 150–162. [Google Scholar] [CrossRef]
  124. Levine, H.L.; Stock, R.; Lilja, J.; Gaasvik, A.; Hummel, H.; Ransohoff, T.C.; Jones, S.D. Single-use technology and modular construction. BioProcess Int. 2013, 11, 40–45. [Google Scholar]
  125. Rogge, P.; Müller, D.; Schmidt, S.R. The single-use or stainless steel decision process. BioProcess Int. 2015, 13. [Google Scholar]
  126. Lipsitz, Y.Y.; Timmins, N.E.; Zandstra, P.W. Quality cell therapy manufacturing by design. Nat. Biotechnol. 2016, 34, 393–400. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Process pipeline for the production and clinical application of a stem cell product (either autologous or allogeneic). European Medicines Agency legislation established good manufacturing practices to be applied from the initial cell isolation and processing to the product fill and finish while also requiring a clear definition of the storage and shipping conditions of the finished cell product. We note that the figure depicts a general stem cell product pipeline and, although most processes already at clinical scale do not perform yet differentiation in the bioreactors. However, we believe the field will move in that direction since using planar platforms will be hardly feasible at a clinical scale.
Figure 1. Process pipeline for the production and clinical application of a stem cell product (either autologous or allogeneic). European Medicines Agency legislation established good manufacturing practices to be applied from the initial cell isolation and processing to the product fill and finish while also requiring a clear definition of the storage and shipping conditions of the finished cell product. We note that the figure depicts a general stem cell product pipeline and, although most processes already at clinical scale do not perform yet differentiation in the bioreactors. However, we believe the field will move in that direction since using planar platforms will be hardly feasible at a clinical scale.
Bioengineering 08 00068 g001
Figure 2. Schematics of a stirred-tank bioreactor vessel and controller unit.
Figure 2. Schematics of a stirred-tank bioreactor vessel and controller unit.
Bioengineering 08 00068 g002
Figure 3. Schematics of a fixed-bed bioreactor.
Figure 3. Schematics of a fixed-bed bioreactor.
Bioengineering 08 00068 g003
Figure 4. Schematics of a hollow fibre bioreactor system and a close-up of the hollow fibre module.
Figure 4. Schematics of a hollow fibre bioreactor system and a close-up of the hollow fibre module.
Bioengineering 08 00068 g004
Figure 5. Schematics of a rotary cell culture system (RCCS): (a) four-station rotator base with one 50 mL vessel and two 10 mL vessels; (b) at low rotation speeds, the cells will settle along the bottom of the vessel; (c) at very high rotational speeds, the cells will be subjected to a predominant centrifugal force, driving them towards the outer wall of the vessel; and (d) at a certain velocity range, the cells will be in suspension, in a simulated microgravity environment.
Figure 5. Schematics of a rotary cell culture system (RCCS): (a) four-station rotator base with one 50 mL vessel and two 10 mL vessels; (b) at low rotation speeds, the cells will settle along the bottom of the vessel; (c) at very high rotational speeds, the cells will be subjected to a predominant centrifugal force, driving them towards the outer wall of the vessel; and (d) at a certain velocity range, the cells will be in suspension, in a simulated microgravity environment.
Bioengineering 08 00068 g005
Figure 6. Schematics of a rotating bed bioreactor.
Figure 6. Schematics of a rotating bed bioreactor.
Bioengineering 08 00068 g006
Figure 7. Schematics of a rocking motion bioreactor. The back-and-forth rocking motion of the base will lead to the formation of waves inside the vessel, allowing for efficient mixing.
Figure 7. Schematics of a rocking motion bioreactor. The back-and-forth rocking motion of the base will lead to the formation of waves inside the vessel, allowing for efficient mixing.
Bioengineering 08 00068 g007
Figure 8. Schematics of a Vertical-Wheel bioreactor: (a) 100 mL vessel with base and (b) 3 L vessel with an embedded controller.
Figure 8. Schematics of a Vertical-Wheel bioreactor: (a) 100 mL vessel with base and (b) 3 L vessel with an embedded controller.
Bioengineering 08 00068 g008
Table 1. Comparison of single-use bioreactor systems for stem cell culture. Working volume ranges indicate a change in volume during the culture. Final cell densities presented are the maximum average obtained among different conditions and/or donors: hESC—human embryonic stem cell; hHSPC—human haematopoietic stem/progenitor cell; hiPSC—human induced pluripotent stem cell; hMSC—human mesenchymal stromal cell; hNSC—human neural stem cell; RBC—red blood cell.
Table 1. Comparison of single-use bioreactor systems for stem cell culture. Working volume ranges indicate a change in volume during the culture. Final cell densities presented are the maximum average obtained among different conditions and/or donors: hESC—human embryonic stem cell; hHSPC—human haematopoietic stem/progenitor cell; hiPSC—human induced pluripotent stem cell; hMSC—human mesenchymal stromal cell; hNSC—human neural stem cell; RBC—red blood cell.
Bioreactor TypeCell TypeWorking Volume/AreaCulture Time (days)Maximum Final Cell DensityRef.
Stirred tankhiPSCs125 mL7(2.9 ± 0.3) × 10 6 cells∙mL–1[29]
1.0-1.5 L7(1.99 ± 0.09) × 10 6 cells∙mL–1[30]
hMSCs15 mL88.1 × 10 5 cells∙mL–1[31]
100–200 mL101.8 × 10 5 cells∙mL–1[32]
1.0–2.0 L74.1 × 10 5 cells∙mL–1[33]
2.0 L7(2.7 ± 0.2) × 10 5 cells∙mL–1[34]
1.0–2.4 L14~ 1 × 10 5 cells∙mL–1[35]
35 L73.1 × 10 5 cells∙mL–1[34]
50 L112.6 × 10 5 cells∙mL–1[36]
hHSPCs10 mL101.4 × 10 7 cells∙mL–1[37]
Fixed bedhMSCs3 mL20.8N/A (1)[38]
14.2 mL5.6(2.9 ± 0.1) × 10 6 cells∙mL–1[39]
60 mL7.01.75 × 10 6 cells∙mL–1[39]
300 mL6.92.05 × 10 6 cells∙mL–1[39]
500 mL7(8.3 ± 1.6) × 10 5 cells∙mL–1[40]
Hollow fibrehESCs2.1 m253.4 × 10 4 cells∙cm–2[41]
hiPSCs2.1 m26–7(3.3 ± 0.4) × 10 4 cells∙cm–2[42]
hNSCs2.1 m27–111.5 × 10 5 cells∙cm–2[43]
hMSCs2.1 m27–9N/A (2)[44]
2.1 m217 ± 6(4.7 ± 0.6) × 10 3 cells∙cm–2[45]
2.1 m28 ± 2(8.0 ± 2.5) × 10 3 cells∙cm–2[46]
2.1 m25(9.8 ± 1.0) × 10 3 cells∙cm–2[47]
2.1 m25(1.1 ± 0.2) × 10 4 cells∙cm–2[48]
2.1 m27.9–9.9(1.8 ± 0.2) × 10 4 cells∙cm–2[49]
2.1 m26(1.9 ± 0.3) × 10 4 cells∙cm–2[50]
2.1 m262.9 × 10 4 cells∙cm–2[51]
2.1 m26–134.7 × 10 4 cells∙cm–2[52]
Rotary cell culture systemhNSCs4 mL3~ 5 × 10 5 cells∙mL–1[53]
hMSCs10 mL14N/A (1)[54]
Rotating bedhMSCs2000 cm25(1.2 ± 0.1) × 10 4 cells∙cm–2[55]
6000 cm29(5.8 ± 0.9) × 10 4 cells∙cm–2[56]
Rocking motionhESCs150 mL (3)42.8 × 10 6 cells∙mL–1[57]
400 mL (3)41.4 × 10 6 cells∙mL–1[57]
1.0 L (3)41.3 × 10 6 cells∙mL–1[57]
hMSCs50–200 mL100(1.32 ± 0.09) × 10 6 cells∙mL–1[58]
50–600 mL104.4 × 10 4 cells∙mL–1[59]
50–600 mL112.2 × 10 5 cells∙mL–1[60]
hHSPC-RBCs200 mL–1 L334.5 × 10 12 cells∙mL–1[61]
Vertical-WheelhiPSCs60 mL80N/A (1)[62]
60 mL7(2.3 ± 0.2) × 10 6 cells∙mL–1[63]
60–73 mL7(1.79 ± 0.03) × 10 6 cells∙mL–1[63]
80 mL9(1.21 ± 0.02) × 10 6 cells∙mL–1[64]
300 mL8(8.6 ± 1.5) × 10 5 cells∙mL–1[64]
100 mL6(6.3 ± 0.4) × 10 5 cells∙mL–1[65]
100 mL6(6.5 ± 0.6) × 10 5 cells∙mL–1[66]
500 mL6~4 × 10 5 cells∙mL–1[66]
hMSCs60 mL41.1 × 10 5 cells∙mL–1[67]
60–100 mL7(5.3 ± 0.4) × 10 5 cells∙mL–1[68]
60–100 mL7–115.3 × 10 5 cells∙mL–1[69]
90–92 mL5~ 6 × 10 5 cells∙mL–1[70]
2.2 L14~ 3 × 10 5 cells∙mL–1[71]
(1) Non-proliferative and/or differentiating cells. (2) The exact cell density achieved is not stated by the authors but is inferred from the text to be around 105 cells∙cm–2. (3) Part of a consecutive passage experiment with increasing scale; overall fold increase of ~280 over 16 days. Individual experiments at each scale with optimised conditions led to better results, but the exact cell density is not indicated in the article.
Table 2. Examples of single-use stirred-tank bioreactor systems with successful use for stem cell culture.
Table 2. Examples of single-use stirred-tank bioreactor systems with successful use for stem cell culture.
BioreactorCompanyImpellerWorking Volume Range
BioBLU®EppendorfEight-blade or pitched-blade100 mL–40 L
Mobius® CellReadyMerckMarine (scoping)1.0–2.4 L
Ambr®Sartorius Stedim BiotechPitched-blade or Rushton10–250 mL
BIOSTAT® CultiBag STR PlusSartorius Stedim BiotechThree- or six-blade12.5–200 L
UniVessel® SUSartorius Stedim BiotechThree-blade600 mL–2.0 L
Table 3. Advantages and limitations of single-use bioreactors as whole and specific single-use platforms.
Table 3. Advantages and limitations of single-use bioreactors as whole and specific single-use platforms.
PlatformAdvantagesDrawbacks/Limitations
Single-use bioreactors
  • Compatible with GMP guidelines
  • Pre-sterilised—no CIP and SIP necessary
  • Closed systems—minor contamination risk
  • Reduced downtime and higher productivity
  • Lower overall environmental impact than reusable systems
  • Lower initial investment
  • Risk of leachables—possible cell growth impairment
  • Maximum scale limited by material resistance
  • Environmental impact of vessel manufacturing, packaging, shipping, and disposal throughout the whole process
  • High running costs
Stirred tank
  • Vast know-how and characterisation
  • Available at many different scales
  • Availability of empirical correlations and criteria for variable estimation and scale-up
  • Variety of agitation mechanisms
  • Some are naturally compatible with perfusion
  • High overall shear stress
  • Heterogeneity of shear stress distribution—existence of hot-spots and stagnated zones
Fixed bed
  • Low shear stress
  • High surface-to-volume ratio and small footprint
  • Naturally compatible with perfusion
  • Formation of concentration gradients
  • Cell harvesting only possible at the end of the culture
  • Difficult cell monitoring
Hollow fibre
  • Low shear stress
  • High surface-to-volume ratio and small footprint
  • Semipermeable membrane system, allowing for indirect mass exchange
  • Naturally compatible with perfusion
  • Formation of concentration gradients
  • Cell harvesting only possible at the end of the culture
  • Difficult cell monitoring
  • Susceptibility to fouling
  • Expensive operation
  • Available only at a single scale (2.1 m2)
Rotary cell culture system
  • Low shear stress
  • Simulated microgravity environment
  • No air bubbles
  • Some are naturally compatible with perfusion
  • Formation of concentration gradients
  • Available only at low scales (up to 50 mL)
Rotating bed
  • Low shear stress
  • High surface-to-volume ratio and small footprint
  • Intermittent contact with medium and headspace
  • Naturally compatible with perfusion
  • Cell harvesting only possible at the end of the culture
  • Difficult cell monitoring
Rocking motion
  • Efficient mixing with low shear stress
  • No air bubbles
  • Some are naturally compatible with perfusion
  • Available at many different scales
  • Resonance phenomenon—spike of shear stress at certain rocking velocities
  • Some cell deposition and microcarrier sticking to vessel walls
Vertical-Wheel
  • Efficient mixing with low shear stress
  • Vessel format avoids cell settling beneath the impeller
  • Narrow gradients of energy dissipation rate
  • Available at many different scales
  • Naturally compatible with perfusion starting from the 3 L scale
  • Still not well characterised
  • Small-scale (100 mL and 500 mL) bioreactors not controlled and incompatible with perfusion
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Nogueira, D.E.S.; Cabral, J.M.S.; Rodrigues, C.A.V. Single-Use Bioreactors for Human Pluripotent and Adult Stem Cells: Towards Regenerative Medicine Applications. Bioengineering 2021, 8, 68. https://0-doi-org.brum.beds.ac.uk/10.3390/bioengineering8050068

AMA Style

Nogueira DES, Cabral JMS, Rodrigues CAV. Single-Use Bioreactors for Human Pluripotent and Adult Stem Cells: Towards Regenerative Medicine Applications. Bioengineering. 2021; 8(5):68. https://0-doi-org.brum.beds.ac.uk/10.3390/bioengineering8050068

Chicago/Turabian Style

Nogueira, Diogo E.S., Joaquim M.S. Cabral, and Carlos A.V. Rodrigues. 2021. "Single-Use Bioreactors for Human Pluripotent and Adult Stem Cells: Towards Regenerative Medicine Applications" Bioengineering 8, no. 5: 68. https://0-doi-org.brum.beds.ac.uk/10.3390/bioengineering8050068

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop