Assessment of Home-Based and Mobility-Based Exposure to Black Carbon in an Urban Environment: A Pilot Study

by
Max Gerrit Adam
1,†,
Phuong Thi Minh Tran
1,2,†,
David Kok Wai Cheong
3,
Sitaraman Chandra Sekhar
3,
Kwok Wai Tham
3 and
Rajasekhar Balasubramanian
1,*
1
Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore
2
Faculty of Environment, The University of Danang—University of Science and Technology, 54 Nguyen Luong Bang Street, Lien Chieu District, Danang City 50608, Vietnam
3
Department of Building, School of Design and Environment, National University of Singapore, Singapore 117566, Singapore
*
Author to whom correspondence should be addressed.
Equal contributions.
Int. J. Environ. Res. Public Health 2021, 18(9), 5028; https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18095028
Submission received: 24 April 2021 / Accepted: 5 May 2021 / Published: 10 May 2021
(This article belongs to the Special Issue Outdoor and Indoor Air Quality)

Abstract

:
The combustion of fossil fuels is a significant source of particulate-bound black carbon (BC) in urban environments. The personal exposure (PE) of urban dwellers to BC and subsequent health impacts remain poorly understood due to a lack of observational data. In this study, we assessed and quantified the levels of PE to BC under two exposure scenarios (home-based and mobility-based exposure) in the city of Trivandrum in India. In the home-based scenario, the PE to BC was assessed in a naturally ventilated building over 24 h each day during the study period while in the mobility-based scenario, the PE to BC was monitored across diverse microenvironments (MEs) during the day using the same study protocol for consistency. Elevated BC concentrations were observed during the transport by motorcycle (26.23 ± 2.33 µg/m3) and car (17.49 ± 2.37 µg/m3). The BC concentrations observed in the MEs decreased in the following order: 16.58 ± 1.38 µg/m3 (temple), 13.78 ± 2.07 µg/m3 (restaurant), 11.44 ± 1.37 µg/m3 (bus stop), and 8.27 ± 1.88 µg/m3 (home); the standard deviations represent the temporal and spatial variations of BC concentrations. Overall, a relatively larger inhaled dose of BC in the range of 148.98–163.87 µg/day was observed for the mobility-based scenario compared to the home-based one (118.10–137.03 µg/day). This work highlights the importance of reducing PE to fossil fuel-related particulate emissions in cities for which BC is a good indicator. The study outcome could be used to formulate effective strategies to improve the urban air quality as well as public health.

1. Introduction

Exposure to black carbon (BC) is of health concern, particularly in developing countries, as it is a carrier of toxic pollutants such as polycyclic aromatic hydrocarbons (PAHs) [1,2,3]. Epidemiological studies have revealed that the short-term and long-term human exposure to BC can lead to cardiovascular [4,5] and respiratory [6,7] diseases and increased mortality [8,9]. Personal exposure (PE) to airborne particulate matter (PM) containing BC in microenvironments (MEs) depends on a number of factors, including age and gender, and the time spent, activity and ventilation conditions in the specific ME [10,11,12,13]. Understanding and quantifying PE patterns related to PM-bound BC provides useful inputs to the development and validation of exposure models [14,15]. BC is mainly found in fine particulate matter (PM2.5, aerodynamic diameter <2.5 µm). PM2.5 exposure levels far exceed the World Health Organization (WHO) Air Quality guideline of the annual average concentration of 10 µg/m3 within India [16]. The health impacts of BC alone are much higher compared to other chemical components in PM2.5 when the parameters are expressed in the same unit of µg m−3 [17]. As India is the second largest emitter of BC in the world [18,19,20], a systematic assessment of PE to BC merits a serious consideration.
Assessment of PE to BC using handheld, portable devices have received considerable attention [21,22,23,24,25]. Recent studies have indicated that among urban MEs, PE to BC occurs predominantly in transport MEs where the internal combustion of fossil fuels in on-road vehicles has been the major source of emissions of PM-bound BC. PE to BC has been investigated for pedestrians [26] and cyclists [27,28,29], and during several modes of transport by commuters, including motorcycles, passenger cars, taxis, buses, and trains [21,30,31,32,33,34,35]. PE to BC has also been characterized on commercial flights between two countries [36], within a country and airports [37]. In most of these studies, it was found that commuters’ PE to elevated levels of BC is of concern and may result in negative health outcomes. To provide better insights into the relationship between the PE to BC and potential health risk, studies have been carried out as a function of time-activity patterns over a combination of several MEs during daily activities, which indicated pronounced potential health impacts from transport MEs [12,22,38,39]. Domestic cooking activities can also increase the potential health risk due to the PE to BC emitted from cooking fuels, the type and intensity of cooking and food ingredients used [40,41,42,43,44].
Trivandrum, a tropical coastal city at the southern tip of the Indian peninsula with a population of about 1 million, was chosen for this study because of the following rationale. Population and economic growth in Trivandrum, the capital of the state of Kerala, have resulted in the increased volume of on-road vehicles, which resulted in the deterioration of ambient air quality [45,46]. However, the impact of this source of air pollution on PE to BC remains unknown. Several previous studies have established the characteristics and anthropogenic nature of BC in Trivandrum based on observational data obtained at an urban background air quality monitoring station, with a mean background BC concentration in the range of 1.50–6.77 µg/m3 [47,48]. Interestingly, during a 2-day lockdown with no vehicles operating in the city, the BC levels dropped to 22% of the average concentrations before the lockdown, highlighting the influence of on-road vehicular emissions on BC levels [46]. Previous studies related to the PE to BC in India were conducted inside a commonly used vehicle (autorickshaw, New Delhi) [49], during daily activities of local residents in New Delhi [50], in domestic kitchens in rural North India [40,51] and among the general population in peri-urban South India [52]. However, the inhaled dose of BC due to PE in diverse MEs was only considered in the study by [52], which mainly focused on predicting at-residence BC levels using exposure modelling and validating it against 24 h BC profiles. Certain members of the local society (e.g., homemakers, elderly citizens) may be spending most of their time at home (indoors) while other individuals who remain mobile may be exposed to various levels of BC in diverse outdoor and transport MEs apart from home microenvironments. Therefore, it is important to gain a better understanding of home-based versus mobility-based PE to BC in urban environments so that effective air quality management strategies can be formulated to improve ambient and indoor air quality (IAQ) and more importantly to protect public health [53]. Such PE studies across MEs over 24 h are seldom conducted in cities [54].
In this pilot study, we assessed and quantified the PE to BC in Trivandrum by addressing two scenarios: (i) home-based PE assessment for 24 h and (ii) mobility-based PE assessment across transport MEs during the day and home-based PE assessment at the nighttime. For the mobility-based PE assessment, the volunteer visited different places of interest in the city (temples, shopping areas, restaurants, and friends and relatives’ homes) using two different modes of transport (a motorcycle and a private car). Inhaled dose values were estimated for BC in each ME, and the cumulative contribution of each ME to the daily integrated inhaled dose of BC was quantified. This mode of PE assessment facilitated the identification of BC hotspots in the urban environment for the home-based and the mobile participants. To our knowledge, the research reported here constitutes the first study of its kind, focused on the PE to BC of mobile city commuters and non-mobile individuals in residential homes.

2. Materials and Methods

2.1. Site Description and Experimental Design

Home-based PE measurements were conducted from December 2018 to January 2019 in a stand-alone house similar to other houses in the city, located in a residential area with no industrial activity in the vicinity on the western part of Trivandrum (Thiruvananthapuram, 8.52° N, 76.93° E, 3 m asl) situated near the south-west coast of India (see Figure 1). The house is situated in the city center about 90 m from a north-south road, which leads to a major hospital to the northern side and the airport to the south. The Arabian Sea coast is about 2 km east of the house. The prevailing meteorological conditions during the study were influenced by north-easterly winds and dry conditions which are typical for this time of the year. No unusual meteorological events were observed during the study period. Trivandrum, due to its coastal location, experiences land/sea breeze, resulting in a diurnal change of the wind direction and speed.
The BC measurement protocol involved the use of two portable BC monitors (described in detail in Section 2.2) by the two participants (volunteers, non-smoking, male, aged 30–40 years old), with one participant continuously monitoring the PE to BC in the indoor environment with high temporal resolution (1 min) and the second participant doing the mobility-based PE assessment in both outdoor and indoor environments (1 min). PE measurements of BC at the residential home (two-storey building) were made at the ground floor level by placing the monitor in the living room (between 0800 and 2200 local time) at the breathing zone height (1.5 m) and the bedroom (2200-0800 LT) at the height of the bed (0.7 m) where the participants were sleeping. The BC exposure concentration in the residential home was relatively uniform. Therefore, the living room location is representative of the PE to BC. Mobility-based PE measurements were carried out by placing the BC monitor inside a backpack with the sampling inlet protruding from the backpack in close proximity to the breathing zone. Whenever the second participant ventured to any location outside of the home environment, the second BC monitor was placed in the backpack with adequate caution given to fixing the inlet such that it would remain in the same position. Also, during mobility-based PE measurements, periodic backpack inspections were made to ensure that the BC monitor was operational, and the sampling tube was not dislodged. Our PE to BC study was conducted for a duration of 10 days for each participant.

2.2. Black Carbon Measurements

BC data were acquired continuously using a portable BC monitor (microAeth AE51; AethLabs Inc., San Francisco, CA, USA). The microAeth measures light absorption at 880 nm on a 3 mm diameter sample spot (I) and an aerosol-free reference spot (I0) in a T60 Teflon-coated glass fiber filter media to obtain attenuation coefficients at the wavelength of 880 nm (referred to hereafter as σAE51, 880 nm) according to:
σ AE 51 ,   880   nm = A   ×   Δ ATN 100 ×   F   ×   Δ t
A: area of the aerosol collecting spot (0.071 cm2), F: flow rate (150 mL/min), ATN: light attenuation calculated from 100 × ln (I0/I), ΔATN: change of ATN during the sampling interval Δt (60 s).
The mass concentration of BC is converted directly from σ AE 51 ,   880   nm using the mass-specific cross-section of BC ( α a b s = 12.5 m2/g, provided by the manufacturer) (Equation (2)).
B C o = σ AE 51 ,   880   nm α a b s
To maintain BC data integrity, several corrective procedures were applied to the collected data. In order to limit a bias from the filter loading of BC on the filter substrate, raw data with attenuation (ATN) values above 80 were not used in the analysis as recommended by [55]. The mass concentration of BC measured using AE51 can be underestimated due to BC loading of the filter, which alters the absorption and scattering of light. Hence, the BC data were corrected for filter loading effects using the procedure proposed by Kirchstetter and Novakov [56] as shown in Equation (3):
BC   = BC o   0.88 Tr   + 0.12 1
BC: corrected black carbon concentration, BCo: instrument-reported concentration, Tr = exp(ATN/100): microAeth filter transmission that is calculated from the instrument-reported attenuation coefficient (ATN).
We applied Equation (3) to all BC measurements. The measurement precision of the microAeth is ±0.1 μg/m3 at 1-min average and a 150 mL/min flow rate with a measurement resolution of 0.001 μg/m3. For quality control, data processing, and analysis, the reader is referred to the Appendix A.

2.3. Fixed Site PM Measurements and Meteorological Parameters

Hourly averaged PM2.5 and meteorological (temperature, relative humidity, wind direction, and wind speed) measurements were acquired from the Central Pollution Control Board website (https://app.cpcbccr.com/ccr/#/caaqm-dashboard-all/caaqm-landing, accessed on 15 March 2020) for Trivandrum for the study period. The location of the automated air quality measurement site is shown in Figure 1.

2.4. Personal Exposure Assessment

The PE of an individual to air pollutants is a function of the concentration (C) and time (t) spent in a particular ME [57]. The exposure concentration to BC (EBC,h in µg/m3) of the participant staying at home (Chome) was calculated as the indoor BC concentration averaged over the time period that the individual is home-bound (thome), shown in Equation (4). Similarly, the calculation of the temporally weighted aggregation of BC exposure in the range of MEs encountered of the mobile participant (EBC,m in µg/m3) is shown in Equation (5).
E B C , h = C h o m e × t h o m e t h o m e
E B C , m = C h o m e × t h o m e   +   C i × t i t h o m e   +   t i      
thome: duration (h) that the participant had spent in the residential home, ti: duration (h) the participant had spent in other MEs (transport, restaurant, temple, leisure AC, leisure non-AC, bus stop).

2.5. Inhaled Dose Calculation

The inhaled dose was estimated based on the exposure concentrations (µg/m3) obtained in each microenvironment over the time spent (i.e., hour/day) in the corresponding ME and the inhaled rate (m3/hour). Calculation of the inhaled dose of BC was done according to Equations (6) and (7):
Integrated   inhaled   dose = i = 1 n Concentration i ×   Inhalation   rate i ×   Exposure   time i  
Inhalation   rate   = Tidal   volume × Breath   frequency
The participants were not involved in intense physical activities such as running and cycling during the study period. The tidal volume chosen was 750 cm3 per breath and the typical breathing frequency selected was 0.20 breaths per second for all-day activities of male adults [58].

3. Results

3.1. BC PE Concentrations at the Home Microenvironment and During Urban Mobility

Figure 2 shows the time series of 48-h PE to BC from the data measured at the residential home and during urban mobile activities. It can be observed that for short periods of time the BC values, while commuting by a car and a motorcycle, exceeded 100 µg/m3 whereas the BC exposure experienced at home was significantly lower, i.e., within the range of 5–20 µg/m3. There were no major indoor activities other than cooking during the course of our IAQ measurements. BC emissions from cooking were likely to be low as the boiling of food items only took place using an LPG gas stove. During the motorcycle ride, the participant was directly exposed to vehicular emissions, whereas during the car commute the air-conditioning system was in operation. This resulted in greater variability of BC exposure for the mobile participant when riding the motorcycle whereas the BC exposure in the car was fairly consistent, as can be seen in Figure 3. As also shown in Table 1, the lowest BC concentration was observed at the home ME with a geometric mean (GM) of 8.27 ± 1.88 µg/m3. In contrast, travel by the motorcycle and the car exhibited the highest PE concentrations with GMs of 26.23 ± 2.33 µg/m3 and 17.49 ± 2.37 µg/m3, respectively with motorcycle exposure being significantly higher (p-value < 0.001, non-parametric Mann-Whitney test) than inside car. Temple (GM: 16.58 ± 1.38 µg/m3), naturally ventilated restaurant (GM: 13.78 ± 2.07 µg/m3), bus stop (GM: 11.44 ± 1.37 µg/m3), and leisure activities in naturally ventilated (GM: 9.04 ± 1.92 µg/m3) and air-conditioned MEs (GM: 7.92 ± 1.55 µg/m3) showed BC concentrations that were still higher than the ones at the residential home. The maximum BC concentration values recorded, while commuting, further underscore the significant short-term PE to BC with concentrations of 381.62 and 288.18 µg/m3 during the ride by motorcycle and car, respectively. Table A1 lists the temporally weighted aggregation of the BC PE showing that the mobile participant on each day and on average (11.99 µg/m3) was exposed to higher BC concentrations than the home-based participant (10.20 µg/m3). The means of BC concentrations measured at home at different times of the day (morning, noon, afternoon, evening, and night), shown in Table A2 were significantly different (p-value < 0.001, non-parametric Kruskal–Wallis test), and showed a diurnal pattern with maxima in the morning (06:00–11:00), evening (17:00–21:00), and night (21:00–06:00) and minima during the day.
Interestingly, the variability of PM2.5 levels (see Figure 2) monitored at the fixed monitoring station, which is about 2.1 km away from the residential home, was reasonably consistent with the BC levels measured at the home ME. Figure A3 shows the correlation between PE to BC at the diverse MEs and the PM2.5 values recorded at the fixed monitoring station. The correlation was moderate to strong in the residential home (r = 0.58), leisure natural ventilation (natural ventilation termed NV hereafter) (0.62), restaurant (0.78), and temple (0.86) MEs while it was the lowest for leisure AC (air conditioning termed AC hereafter) (0.07), car (0.07), and motorcycle (0.23).

3.2. Daily Integrated BC Dose on Five Different Days

Figure 4 shows BC inhaled dose values for five representative days on which simultaneous mobility and home-based BC PE observations were recorded. For the mobility-based PE assessment, the participant was mobile, i.e., spending time in the city commuting to different MEs such as restaurants, or pursuing leisure activities in non-air-conditioned and air-conditioned spaces, whereas the home-based PE assessment refers to the PE to BC experienced by the other participant while remaining at home with no participation in outdoor activities (on the same five days for consistency). The corresponding BC values are listed in Table A3. In general, as can be seen in Figure 4, the daily inhaled dose of BC was higher for the participant involved in outdoor activities compared to the participant remaining at home. The differences in the inhaled dose values between each day ranged from 29% for day 1 to 8% for day 3. The mobile participant spent 68–80% of 24 h in the home environment. The remaining time was spent in transport MEs (5–12%) and other MEs (12–20%). The secondary major contributor to the total daily BC inhaled dose was related to local transport on most of the days (21.1% on average) with the exception on day 3 where a restaurant visit contributed 22% to the total daily intake and transport only 8%.

3.3. Indoor to Outdoor Ratios of BC PE

The simultaneous home-based and mobility-based BC PE observations allowed us to calculate the mean home-based (HB) to the mobility-based (MB) BC PE ratios, HB/MB (see Table 1). Overall, the HB/MB BC ratios of the mobility-based participant were less than 1 in all MEs except for the bus stop (1.45) and leisure NV (1.11). For motorcycle (0.58) and car (0.69), and temple (0.74), the HB/MB ratios were fairly low while they were close to 1 for the restaurant (0.93) and leisure AC (0.96).

4. Discussion

The integrated PE to BC over 24 h and its health outcomes are determined by air quality levels prevailing in indoor as well as outdoor MEs. Since urban dwellers tend to spend up to 90% of their time in indoor environments [59], it is of particular importance to consider the IAQ’s contribution to PE on a day-to-day basis. Our results for the home-based participant (and the mobile participant when at the same home) show that the BC exposure at the residential location (8.27 µg/m3) was elevated by a factor of approximately 2–3 when compared to the fixed site monitoring BC data reported in the literature for Trivandrum [45,47]. Also, compared to a PE study by [50] involving observations of BC at a home environment in New Delhi (2.78 µg/m3), our observations are significantly higher. In fact, the mean BC concentration, a minor component of PM2.5, in the residential indoor environment is even similar to the WHO’s annual air quality guideline value of 10 µg/m3 for PM2.5.
There are several factors that influence IAQ including measurement locations, indoor activities, the mode of ventilation (e.g., natural ventilation or air conditioning), and building design [11,60,61,62,63,64]. In recent years, air quality studies have focused on urbanized areas where an increasingly large proportion of the world’s population lives (55%), but is also exposed to traffic-related pollution due to the high number of vehicles and the proximity of homes, offices, and leisure places to roads as well as PM emissions from haze episodes [60,61,65,66,67].
With respect to India, BC levels inside homes have been shown to be enhanced due to the use of household fuels such as wood and coal with less combustion efficiency [40,68]. However, for our study, the influence of cooking fuels on the measured BC concentrations appears to make a minor contribution as liquid petroleum gas (LPG) was used as cooking fuel which emits significantly less PM compared to wood, coal, and oil [69]. The residence of the home-based participant is approximately only 90 m away from a main road carrying a high traffic volume. We carried out concurrent measurements of BC over 48 h inside the home and at a location just outside of it to study the influence of outdoor air quality (OAQ) on IAQ. The indoor to outdoor BC ratio was nearly one (I/O BC ratio ~ 1), indicating that the outdoor BC influenced the BC levels indoors, when there were no major indoor air pollution sources. Therefore, the high PE BC concentrations can likely be attributed to vehicular emissions of PM2.5. This interpretation is consistent with the fact that ambient air quality in urban areas is often substantially influenced by emissions from vehicular traffic, particularly in South and Southeast Asia [70,71,72,73,74].
For the mobile participant in our study, the BC exposure is a combination of BC concentrations encountered in several MEs. The participant’s highest BC exposure was observed during the travel by the motorcycle (26.23 µg/m3) and car (17.49 µg/m3), suggesting that the health risk associated with urban mobility during peak commuting hours is significant. Our observations pointing to PE to high BC levels during commuting in India are consistent with the findings from BC PE studies reported by [49,50]. Autorickshaws (23.40 µg/m3) and buses (14.10 µg/m3) were reported to be major BC emission sources by [50]. However, autorickshaws (42.00 µg/m3) were the only mode of transport investigated by [49]. The BC PE levels inside the car were approximately 33% lower compared to the motorcycle for the mobile participant which can be attributed to the operation of the AC system (used in a recirculation setting mode with windows closed). The filtration system of the AC prevents the entry of airborne particles into the in-cabin environment, thus reducing the PE to BC concentrations. The association between ventilation settings and in-vehicle exposure has been reported with a decrease in air pollutant concentrations when windows were closed and the AC was on [75,76,77]. However, during motorcycle trips, no PM mitigating device was in place, which exposed the rider directly to freshly emitted airborne particles from the fossil fuel combustion in other on-road vehicles (motorcycles, cars, bus, and trucks), accounting for the higher BC concentrations [49,77].
For the mobile participant, we observed high BC concentrations while carrying out daily routine tasks. We categorized these MEs as restaurants, leisure places equipped with AC (supermarket, photostudio, bakery, and polyclinics) and naturally ventilated leisure places (community centers and fruit stores). Furthermore, PE to BC was investigated at bus stops in the city. All of the aforementioned MEs are locations in urban areas, which the local population frequently visits during their daily life, and were hence chosen as representative areas to determine the BC PE levels. The BC PE concentrations at all the MEs are higher than at the home environment (8.27 µg/m3), with the exception of leisure place with AC (7.92 µg/m3), which can be attributed to the filtration of PM by the AC systems in place at the respective buildings [78]. High PE to BC levels was experienced at the temple (16.58 µg/m3), likely due to the burning of incense sticks and candles, which are accompanied by high emissions of PM and BC [74,79,80,81]. Elevated BC PE concentrations were also observed at bus stops (11.44 µg/m3). Bus stops are associated with intense and highly localized emissions of BC owing to various vehicular activities such as deceleration, idling and acceleration which have been shown to lead to higher BC emissions [74,82]. The high BC PE concentrations at restaurants (naturally ventilated, 13.78 µg/m3) are likely a result of the combination of ambient (outdoor) BC concentrations, cooking activities, and cooking fuels used [41,83].
The measurement of the indoor to outdoor (I/O) ratio of air pollutants, monitored at indoor and outdoor locations of the same building, plays an important role in identifying the potential source of air pollutants. This ratio facilitates the interpretation of factors that influence the migration of air pollutants between indoor and outdoor environments such as ventilation type (natural or mechanical) and infiltration. In our study, the MEs visited by the mobility-based participant were farther away from the home ME. Therefore, we have calculated the HB/MB ratio and used it in place of the I/O ratio. The low HB/MB ratios for BC further underscore that the mobility-based participant in most MEs was subjected to increased BC exposure in MEs in the city. The variation in the HB/MB values (0.58–1.45) is likely to be driven by outdoor concentrations of BC in a majority of the MEs for our study as indoor emission of BC from cooking was only observed at the restaurant while incense burning took place at the temple; other instances of potential BC emissions from cooking, smoking and/or incense burning in any of the other MEs or at the naturally ventilated home did not take place. Nevertheless, it should be noted that the filtration of outdoor air in the air conditioning system of the car (in-cabin) and leisure ME (indoors) tends to reduce the BC exposure. In our study, the HB/MB ratios estimated for BC are generally higher compared to I/O values calculated for BC in California, USA (0.6–0.65) by [84] and are comparable to those in Vietnam (0.96–1.09) [66], suggesting that the home ME in Trivandrum is strongly influenced by BC emissions in the city.
Previous studies on BC emissions in Trivandrum reported the influence of boundary layer dynamics and transport on BC concentrations [46,47]. Source apportionment results indicated that around 66% of BC originates from the local traffic [85]. The results from the mobile-based exposure scenario indicate high PE concentrations of BC during urban mobility (car and motorcycle). This observation reinforces the earlier findings from home-based PE observations that the main source of BC in Trivandrum is from local traffic-related activities. In addition, the moderate to strong correlation between BC and PM2.5 in several of the naturally ventilated MEs (i.e., home, leisure, restaurant, and temple) is indicative of the significant contribution of fossil fuel-based combustion emissions to PM in Trivandrum. The low correlation in the transport MEs for car (0.07) and motorcycle (0.23) may be due to the BC measurements taking place in close proximity to the source of combustion emissions (thus high BC values as shown earlier) and low number of data points recorded in these MEs compared to the other locations. This would suggest the inadequacy of data collected at fixed monitoring stations for health risk estimations.
The inhaled dose value of BC for the home-based participant ranged from 118.10 to 137.03 µg/day while it was from 148.98 to 163.87 µg/day for the mobile participant. These BC inhaled dose values were significantly higher than the BC inhaled dose values reported in other studies, for example, adults in Belgium (14.10–77.70 µg/day) [21], children in South Korea (6.60–46.30 µg/day) [38], and children in Italy (39.20 µg/day) [43]. In addition to adverse health effects, the PE to elevated BC levels over a short duration or moderate BC levels over an extended time period may harm people’s cognitive performance [86,87,88].
In general, studies investigating human health effects of BC have mostly relied on ambient air quality measurements to assess the exposure of local populations to BC [1] which does not fully represent their actual exposure [11,74] as evident from the current study. Sharma and Balasubramanian (2019) investigated the influence of traffic-related PM emissions at a naturally ventilated residence, which is located in close proximity to a road, and the possibility of mitigating the inhalation of PM for the occupants of the apartment [71]. Their findings indicate that potential long-term health effects are associated with the inhalation of PM-bound toxic trace elements and that the use of a mitigation device such as a portable air cleaner (PAC) reduces indoor PM concentration levels by up to 74% yielding tangible health benefits at an affordable cost and with energy efficiency. The use of a fan filter unit in student dormitories [89] has also demonstrated the effective reduction of PM10, PM2.5, and PM1 particle concentrations by 80.9%, 80.4%, and 78.5%, respectively.

5. Limitations of the Study

We acknowledge that our pilot study has certain limitations, such as the small number of participants and limited spatio-temporal profiles of BC in the aforementioned MEs of Trivandrum. The BC data were only collected with two volunteers for a short duration of time (10 days) in one season. The reason for this limitation is that our BC measurements were conducted only on dry days, rain events occurred on all other days from December 2018 to January 2019. The BC data in the transport MEs were limited to only two modes of transport and only one ventilation scenario for car (AC) for a particular engine type. Future studies may need to address these shortcomings. Additionally, more extensive PE to BC studies should be conducted over a larger geographical area and longer time duration with participation of more volunteers to obtain a more robust dataset which can be used to quantify health risk due to exposure to BC as done by [40]. Nevertheless, the practical implications of our study as stated below provide the impetus for conducting more research on PE to BC in cities.

6. Practical Implications

Our findings show that the PE to BC in urban environments within India is likely to remain elevated at indoor and outdoor MEs because of the increased population of vehicles and traffic congestion with no major expansion of city infrastructure. Consequently, city commuters are likely to be subject to a high level of health risk due to inhalation of BC and other air pollutants of traffic origin. The health status of homemakers, the elderly, and children could be affected adversely while remaining indoors in naturally ventilated buildings with no PM mitigation devices due to the migration of freshly emitted airborne particles from the outdoor environment. In order to effectively improve air quality in Indian cities and public health, we suggest that PE measurements using mobile devices be conducted to complement a wide network of fixed ambient air quality monitoring stations on the city scale as demonstrated by [74,90]. The use of portable air cleaners, or fan filter units indoors is a cost-effective measure to mitigate the PE to air pollutants when needed [89,90,91]. A conceptual study in this direction, incorporating real-time air quality information based on model simulation and measurements, has recently been demonstrated in Hong Kong by [53]. The outcome of these studies can be used by citizens to make informed decisions to reduce their personal exposure to airborne pollutants. In the long-term, investments should be made to decarbonize the transportation sector with introduction of electrical mobility together with active modes of transport such as walking and cycling.

7. Conclusions

Urban dwellers are consistently exposed to high levels of BC emitted from anthropogenic activities, but little is known about their personal exposure to BC levels. While several studies in urban areas focus on PM2.5 and its relevance as a health indicator, BC is considered a more accurate metric to study health implications. The findings from this study revealed that the inhaled dose of BC is enhanced for city commuters resulting in potentially higher health risks compared to individuals staying at home because of intense human activities in diverse MEs and the combustion of fossil fuels in the transport sector. While air-conditioned spaces in the city (such as AC buildings) had a lower level of BC as compared to the naturally ventilated residential home, the reduction was found to be only minor. In the short-term, the feasibility of other mitigation options (e.g., portable air cleaners and fan filter units) for naturally ventilated buildings should be explored. These mitigation technologies are both affordable for citizens living in developing countries and sustainable when viewed from a long-term climate perspective. Overall, our study shows that decarbonization measures have to be put in place in Indian cities like Trivandrum to provide co-benefits of air quality improvement, climate change mitigation, and healthy living. As this work was carried out as a pilot study with only two participants, future studies should investigate PE with a larger number of subjects for longer periods of time. In addition, such studies should also involve a more comprehensive analysis of BC and co-emitted air pollutants from the combustion of fossil fuels to present a more accurate representation of long-term health effects.

Author Contributions

Conceptualization, M.G.A., R.B.; methodology, M.G.A.; data curation, M.G.A., P.T.M.T.; formal analysis, M.G.A., P.T.M.T.; visualization, M.G.A., P.T.M.T., writing—original draft, M.G.A., P.T.M.T., D.K.W.C., S.C.S., K.W.T., R.B.; writing—review and editing, M.G.A., P.T.M.T., D.K.W.C., S.C.S., K.W.T., R.B.; supervision, R.B.; project administration, R.B.; funding acquisition, R.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Research Foundation (NRF), the Prime Minister’s Office, Singapore, under its Campus for Research Excellence and Technological Enterprise (CREATE) program and by the Global Alliance Project funded by the National University (NUS) of Singapore. The authors are grateful to the NRF for financial support from Grant No. R-706-000-236-114 and to NUS for R-302-000-195-133.

Institutional Review Board Statement

Not applicable to this study.

Informed Consent Statement

Not applicable to this study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

Quality Control, Data Processing and Analysis

Before each use of the two AE51 units, battery and memory checks were carried out, and clock synchronization was performed using a laptop connected to the Internet. As part of the QC protocol, noteworthy observations such as the low flow of the instrument were recorded, and the BC data collected under those conditions were removed during the process of data analysis. Furthermore, the air flows through the two microAeths were calibrated with a flowmeter (TSI, model 4100, Shoreview, MN, USA) following the auto-flow calibration procedure, recommended by the manufacturer. Further calibration of microAeths was done through an intercomparison with the Aethalometer AE33. The real-time data from the AE51 were downloaded, inspected, and archived twice a day. Other potential data quality issues (missing data, negative or otherwise spurious readings) were flagged for subsequent evaluation and resolution. We used the R statistical software [92] to import, synchronize, and combine datasets and to apply corrections, calibrations, and perform statistical analysis. The filter in the microAeths was changed every 8–12 h, depending upon the BC loading in the microenvironment where the PE monitoring was conducted. After changing the filter, the BC data collected were backed up on an external hard drive and the time (local time) on the BC monitor was synchronized to account for the time drift on the portable device. The performance of the two BC monitors was comparatively evaluated for 12 h at appropriate locations (see Figure A1) with the same flow configuration and sampling frequency used in the fieldwork, showing excellent reproducibility and a high linear correlation (coefficient of determination r2 = 0.98, slope = 0.99). We also collocated the two AE51 devices with an Aethalometer AE33 (Magee Scientific, USA) for a duration of 24 h to test the data integrity (see Figure A2). A good agreement for each device with the AE33 was obtained with r2 = 0.81 and 0.78, and slope = 0.9976 and 0.9713.
Table A1. Daily BC personal exposure concentrations for the home-based and mobility-based participant on representative days.
Table A1. Daily BC personal exposure concentrations for the home-based and mobility-based participant on representative days.
ParticipantMeasured DayAverage BC (µg/m3)
Home-based exposureDay 19.11
Day 210.68
Day 310.49
Day 410.16
Day 510.57
Average10.20
Mobility exposureDay 111.72
Day 211.50
Day 312.27
Day 411.84
Day 512.64
Average11.99
Table A2. BC personal exposure concentrations at home according to the time of the day.
Table A2. BC personal exposure concentrations at home according to the time of the day.
MetricMorningNoonAfternoonEveningNightTotal
BC,
µg/m3
AM9.866.535.9912.0311.9310.05
AM SD3.5911.219.116.256.767.58
GM9.215.334.7610.4210.158.30
GM SD1.461.771.741.751.771.86
max23.79240.17154.1033.4745.36240.17
min3.150.110.000.303.070.00
N208191318981892401510,799
CI0.150.730.410.280.210.14
Morning: 06:00–11:00; Noon: 11:00–13:00; Afternoon: 13:00–17:00; Evening: 17:00–21:00; Night: 21:00–6:00.
Table A3. Daily integrated exposure dose to BC in different MEs in Trivandrum on representative days.
Table A3. Daily integrated exposure dose to BC in different MEs in Trivandrum on representative days.
MetricBC Dose in Different MEs (µg/day)Sum (µg/day)
HomeTransportLeisure-NVLeisure-ACRestaurantDifference
(%)
Home-based exposureDay 1118.10--------118.10--
Day 2138.39--------138.39--
Day 3136.01--------136.01--
Day 4131.64--------131.64--
Day 5137.03--------137.03--
Mobility-based exposureDay 184.9349.436.4011.17--151.9228.63
Day 2102.4524.8921.65----148.987.65
Day 3110.4113.19--22.3335.46159.0716.96
Day 490.3251.066.90--5.15153.4316.55
Day 5109.7223.9122.158.10--163.8719.59
Leisure NV: community centers, vegetable store. Leisure AC: supermarket, photostudio, bakery, polyclinics.--: No measurement.
Figure A1. Intercomparison of the two BC monitors (microAeth AE51) used during the study period by the participants. The black line shows the linear regression fit to the data.
Figure A1. Intercomparison of the two BC monitors (microAeth AE51) used during the study period by the participants. The black line shows the linear regression fit to the data.
Ijerph 18 05028 g0a1
Figure A2. Intercomparison of the microAeth AE51 and the Aethalometer AE33. The solid lines (blue and red) show the linear regression fit to the data.
Figure A2. Intercomparison of the microAeth AE51 and the Aethalometer AE33. The solid lines (blue and red) show the linear regression fit to the data.
Ijerph 18 05028 g0a2
Figure A3. Correlation between PE to BC and PM2.5 concentrations obtained from FMS across different MEs for the two participants. The shaded grey area is representative of the 95% confidence interval.
Figure A3. Correlation between PE to BC and PM2.5 concentrations obtained from FMS across different MEs for the two participants. The shaded grey area is representative of the 95% confidence interval.
Ijerph 18 05028 g0a3

References

  1. WHO. World Health Organization: Health Effects of Black Carbon; WHO Regional Office for Europe: Copenhagen, Denmark, 2012. [Google Scholar]
  2. Brauer, M.; Freedman, G.; Frostad, J.; Van Donkelaar, A.; Martin, R.V.; Dentener, F.; Van Dingenen, R.; Estep, K.; Amini, H.; Apte, J.S.; et al. Ambient Air Pollution Exposure Estimation for the Global Burden of Disease. Environ. Sci. Technol. 2016, 50, 79–88. [Google Scholar] [CrossRef]
  3. Lim, S.S.; Vos, T.; Flaxman, A.D.; Danaei, G.; Shibuya, K.; Adair-Rohani, H.; AlMazroa, A.M.; Amann, M.; Anderson, H.R.; Andrews, K.G.; et al. A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990–2010: A systematic analysis for the Global Burden of Disease Study. Lancet 2012, 380, 2224–2260. [Google Scholar] [CrossRef] [Green Version]
  4. McCracken, J.; Baccarelli, A.; Hoxha, M.; Dioni, L.; Melly, S.; Coull, B.; Suh, H.; Vokonas, P.; Schwartz, J. Annual Ambient Black Carbon Associated with Shorter Telomeres in Elderly Men: Veterans Affairs Normative Aging Study. Environ. Health Perspect. 2010, 118, 1564–1570. [Google Scholar] [CrossRef] [Green Version]
  5. Wellenius, G.A.; Burger, M.R.; Coull, B.A.; Schwartz, J.; Suh, H.H.; Koutrakis, P.; Schlaug, G.; Gold, D.R.; Mittleman, M.A. Ambient Air Pollution and the Risk of Acute Ischemic Stroke. Arch. Intern. Med. 2012, 172, 229–234. [Google Scholar] [CrossRef]
  6. Lin, W.; Huang, W.; Zhu, T.; Hu, M.; Brunekreef, B.; Zhang, Y.; Liu, X.; Cheng, H.; Gehring, U.; Li, C.; et al. Acute Respiratory Inflammation in Children and Black Carbon in Ambient Air before and during the 2008 Beijing Olympics. Environ. Health Perspect. 2011, 119, 1507–1512. [Google Scholar] [CrossRef] [Green Version]
  7. Patel, M.M.; Chillrud, S.N.; Correa, J.C.; Hazi, Y.; Feinberg, M.; Kc, D.; Prakash, S.; Ross, J.M.; Levy, D.; Kinney, P.L. Traffic-Related Particulate Matter and Acute Respiratory Symptoms among New York City Area Adolescents. Environ. Health Perspect. 2010, 118, 1338–1343. [Google Scholar] [CrossRef] [Green Version]
  8. Luben, T.J.; Nichols, J.L.; Dutton, S.J.; Kirrane, E.; Owens, E.O.; Datko-Williams, L.; Madden, M.; Sacks, J.D. A systematic review of cardiovascular emergency department visits, hospital admissions and mortality associated with ambient black carbon. Environ. Int. 2017, 107, 154–162. [Google Scholar] [CrossRef]
  9. Gan, W.Q.; Koehoorn, M.; Davies, H.W.; Demers, P.A.; Tamburic, L.; Brauer, M. Long-Term Exposure to Traffic-Related Air Pollution and the Risk of Coronary Heart Disease Hospitalization and Mortality. Environ. Health Perspect. 2011, 119, 501–507. [Google Scholar] [CrossRef]
  10. Violante, F.S.; Barbieri, A.; Curti, S.; Sanguinetti, G.; Graziosi, F.; Mattioli, S. Urban atmospheric pollution: Personal exposure versus fixed monitoring station measurements. Chemosphere 2006, 64, 1722–1729. [Google Scholar] [CrossRef] [PubMed]
  11. Steinle, S.; Reis, S.; Sabel, C.E.; Semple, S.; Twigg, M.M.; Braban, C.F.; Leeson, S.R.; Heal, M.R.; Harrison, D.; Lin, C.; et al. Personal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments. Sci. Total Environ. 2015, 508, 383–394. [Google Scholar] [CrossRef] [Green Version]
  12. Dons, E.; Panis, L.I.; Van Poppel, M.; Theunis, J.; Willems, H.; Torfs, R.; Wets, G. Impact of time–activity patterns on personal exposure to black carbon. Atmos. Environ. 2011, 45, 3594–3602. [Google Scholar] [CrossRef]
  13. Van Tran, V.; Park, D.; Lee, Y.-C. Indoor Air Pollution, Related Human Diseases, and Recent Trends in the Control and Improvement of Indoor Air Quality. Int. J. Environ. Res. Public Health 2020, 17, 2927. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Kerckhoffs, J.; Hoek, G.; Vlaanderen, J.; van Nunen, E.; Messier, K.; Brunekreef, B.; Gulliver, J.; Vermeulen, R. Robustness of intra urban land-use regression models for ultrafine particles and black carbon based on mobile monitoring. Environ. Res. 2017, 159, 500–508. [Google Scholar] [CrossRef]
  15. Krauskopf, J.; van Veldhoven, K.; Chadeau-Hyam, M.; Vermeulen, R.; Carrasco-Turigas, G.; Nieuwenhuijsen, M.; Vineis, P.; de Kok, T.M.; Kleinjans, J.C. Short-term exposure to traffic-related air pollution reveals a compound-specific circulating miRNA profile indicating multiple disease risks. Environ. Int. 2019, 128, 193–200. [Google Scholar] [CrossRef] [PubMed]
  16. Guttikunda, S.K.; Nishadh, K.; Jawahar, P. Air pollution knowledge assessments (APnA) for 20 Indian cities. Urban. Clim. 2019, 27, 124–141. [Google Scholar] [CrossRef]
  17. Janssen, N.A.; Hoek, G.; Simic-Lawson, M.; Fischer, P.; Van Bree, L.; ten Brink, H.; Keuken, M.; Atkinson, R.W.; Anderson, H.R.; Brunekreef, B.; et al. Black Carbon as an Additional Indicator of the Adverse Health Effects of Airborne Particles Compared with PM10and PM2. Environ. Health Perspect. 2011, 119, 1691–1699. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Bond, T.C.; Doherty, S.J.; Fahey, D.W.; Forster, P.M.; Berntsen, T.; DeAngelo, B.J.; Flanner, M.G.; Ghan, S.; Kaercher, B.; Koch, D.; et al. Bounding the role of black carbon in the climate system: A scientific assessment. J. Geophys. Res. Atmos. 2013, 118, 5380–5552. [Google Scholar]
  19. Dey, S.; Di Girolamo, L.; van Donkelaar, A.; Tripathi, S.; Gupta, T.; Mohan, M. Variability of outdoor fine particulate (PM2.5) concentration in the Indian Subcontinent: A remote sensing approach. Remote. Sens. Environ. 2012, 127, 153–161. [Google Scholar] [CrossRef]
  20. Rana, A.; Jia, S.; Sarkar, S. Black carbon aerosol in India: A comprehensive review of current status and future prospects. Atmos. Res. 2019, 218, 207–230. [Google Scholar] [CrossRef]
  21. Dons, E.; Panis, L.I.; Van Poppel, M.; Theunis, J.; Wets, G. Personal exposure to Black Carbon in transport microenvironments. Atmos. Environ. 2012, 55, 392–398. [Google Scholar] [CrossRef]
  22. Jeong, H.; Park, D. Characteristics of elementary school children’s daily exposure to black carbon (BC) in Korea. Atmos. Environ. 2017, 154, 179–188. [Google Scholar] [CrossRef]
  23. Guang-Li, X.; Lei, X.-N.; Xiu, G.-L.; Gao, C.-Y.; Gao, S.; Qian, N.-S. Personal exposure to black carbon during commuting in peak and off-peak hours in Shanghai. Sci. Total Environ. 2015, 524–525, 237–245. [Google Scholar]
  24. Williams, R.D.; Knibbs, L.D. Daily personal exposure to black carbon: A pilot study. Atmos. Environ. 2016, 132, 296–299. [Google Scholar] [CrossRef] [Green Version]
  25. Choi, S.; Park, J.-H.; Kim, S.-Y.; Kwak, H.; Kim, D.; Lee, K.-H.; Park, D.-U. Characteristics of PM2.5 and Black Carbon Exposure Among Subway Workers. Int. J. Environ. Res. Public Health 2019, 16, 2901. [Google Scholar] [CrossRef] [Green Version]
  26. Qiu, Z.; Lv, H.; Zhang, F.; Wang, W.; Hao, Y. Pedestrian exposure to PM2.5, BC and UFP of adults and teens: A case study in Xi’an, China. Sustain. Cities Soc. 2019, 51, 101774. [Google Scholar] [CrossRef]
  27. Brand, V.S.; Kumar, P.; Damascena, A.S.; Pritchard, J.P.; Geurs, K.T.; de Fatima Andrade, M. Impact of route choice and period of the day on cyclists’ exposure to black carbon in London, Rotterdam and São Paulo. J. Transp. Geogr. 2019, 76, 153–165. [Google Scholar] [CrossRef]
  28. Krecl, P.; Cipoli, Y.A.; Targino, A.C.; de Oliveira Toloto, M.; Segersson, D.; Parra, Á.; Polezer, G.; Godoi, R.H.M.; Gidhagen, L. Modelling urban cyclists’ exposure to black carbon particles using high spatiotemporal data: A statistical approach. Sci. Total Environ. 2019, 679, 115–125. [Google Scholar] [CrossRef]
  29. Hofman, J.; Samson, R.; Joosen, S.; Blust, R.; Lenaerts, S. Cyclist exposure to black carbon, ultrafine particles and heavy metals: An experimental study along two commuting routes near Antwerp, Belgium. Environ. Res. 2018, 164, 530–538. [Google Scholar] [CrossRef]
  30. Targino, A.C.; Rodrigues, M.V.C.; Krecl, P.; Cipoli, Y.A.; Ribeiro, J.P.M. Commuter exposure to black carbon particles on diesel buses, on bicycles and on foot: A case study in a Brazilian city. Environ. Sci. Pollut. Res. 2018, 25, 1132–1146. [Google Scholar] [CrossRef]
  31. Ham, W.; Vijayan, A.; Schulte, N.; Herner, J.D. Commuter exposure to PM2.5, BC, and UFP in six common transport microenvironments in Sacramento, California. Atmos. Environ. 2017, 167, 335–345. [Google Scholar] [CrossRef]
  32. Merritt, A.-S.; Georgellis, A.; Andersson, N.; Bedada, G.B.; Bellander, T.; Johansson, C. Personal exposure to black carbon in Stockholm, using different intra-urban transport modes. Sci. Total Environ. 2019, 674, 279–287. [Google Scholar] [CrossRef] [PubMed]
  33. Onat, B.; Şahin, Ü.A.; Uzun, B.; Akın, Ö.; Özkaya, F.; Ayvaz, C. Determinants of exposure to ultrafine particulate matter, black carbon, and PM2.5 in common travel modes in Istanbul. Atmos. Environ. 2019, 206, 258–270. [Google Scholar] [CrossRef]
  34. Moreno, T.; Reche, C.; Rivas, I.; Minguillón, M.C.; Martins, V.; Vargas, C.; Buonanno, G.; Parga, J.; Pandolfi, M.; Brines, M.; et al. Urban air quality comparison for bus, tram, subway and pedestrian commutes in Barcelona. Environ. Res. 2015, 142, 495–510. [Google Scholar] [CrossRef]
  35. Quang, T.N.; Hue, N.T.; Van Dat, M.; Tran, L.K.; Phi, T.H.; Morawska, L.; Thai, P.K. Motorcyclists have much higher exposure to black carbon compared to other commuters in traffic of Hanoi, Vietnam. Atmos. Environ. 2021, 245, 118029. [Google Scholar] [CrossRef]
  36. Le, H.A. Real-time black carbon personal exposure levels in microenvironments: Home to home on a round-trip, Hanoi–Singapore. J. Air Waste Manag. Assoc. 2018, 69, 259–265. [Google Scholar]
  37. Targino, A.C.; Machado, B.L.F.; Krecl, P. Concentrations and personal exposure to black carbon particles at airports and on commercial flights. Transp. Res. Part. D: Transp. Environ. 2017, 52, 128–138. [Google Scholar] [CrossRef]
  38. Jeong, H.; Park, D. Contribution of time-activity pattern and microenvironment to black carbon (BC) inhalation exposure and potential internal dose among elementary school children. Atmos. Environ. 2017, 164, 270–279. [Google Scholar] [CrossRef]
  39. Dons, E.; Laeremans, M.; Orjuela, J.P.; Avila-Palencia, I.; De Nazelle, A.; Nieuwenhuijsen, M.; Van Poppel, M.; Carrasco-Turigas, G.; Standaert, A.; De Boever, P.; et al. Transport most likely to cause air pollution peak exposures in everyday life: Evidence from over 2000 days of personal monitoring. Atmos. Environ. 2019, 213, 424–432. [Google Scholar] [CrossRef]
  40. Ravindra, K. Emission of black carbon from rural households kitchens and assessment of lifetime excess cancer risk in villages of North India. Environ. Int. 2019, 122, 201–212. [Google Scholar] [CrossRef]
  41. Abdullahi, K.L.; Delgado-Saborit, J.M.; Harrison, R.M. Emissions and indoor concentrations of particulate matter and its specific chemical components from cooking: A review. Atmos. Environ. 2013, 71, 260–294. [Google Scholar] [CrossRef]
  42. Rupakheti, D.; Oanh, N.T.K.; Rupakheti, M.; Sharma, R.K.; Panday, A.K.; Puppala, S.P.; Lawrence, M.G. Indoor levels of black carbon and particulate matters in relation to cooking activities using different cook stove-fuels in rural Nepal. Energy Sustain. Dev. 2019, 48, 25–33. [Google Scholar] [CrossRef]
  43. Buonanno, G.; Stabile, L.; Morawska, L.; Russi, A. Children exposure assessment to ultrafine particles and black carbon: The role of transport and cooking activities. Atmos. Environ. 2013, 79, 53–58. [Google Scholar] [CrossRef] [Green Version]
  44. Zhang, Q.; Gangupomu, R.H.; Ramirez, D.; Zhu, Y. Measurement of Ultrafine Particles and Other Air Pollutants Emitted by Cooking Activities. Int. J. Environ. Res. Public Health 2010, 7, 1744–1759. [Google Scholar] [CrossRef]
  45. Babu, S.S.; Moorthy, K.K. Anthropogenic impact on aerosol black carbon mass concentration at a tropical coastal station: A case study. Curr. Sci. 2001, 81, 1208–1214. [Google Scholar]
  46. Kompalli, S.K.; Moorthy, K.K.; Babu, S.S. Rapid response of atmospheric BC to anthropogenic sources: Observational evidence. Atmos. Sci. Lett. 2013, 15, 166–171. [Google Scholar] [CrossRef]
  47. Babu, S.S.; Moorthy, K.K. Aerosol black carbon over a tropical coastal station in India. Geophys. Res. Lett. 2002, 29, 13–21. [Google Scholar] [CrossRef]
  48. Rajeevan, K.; Sumesh, R.; Resmi, E.; Unnikrishnan, C. An observational study on the variation of black carbon aerosol and source identification over a tropical station in south India. Atmos. Pollut. Res. 2019, 10, 30–44. [Google Scholar] [CrossRef]
  49. Apte, J.S.; Kirchstetter, T.W.; Reich, A.H.; Deshpande, S.J.; Kaushik, G.; Chel, A.; Marshall, J.D.; Nazaroff, W.W. Concentrations of fine, ultrafine, and black carbon particles in auto-rickshaws in New Delhi, India. Atmos. Environ. 2011, 45, 4470–4480. [Google Scholar] [CrossRef]
  50. Pant, P.; Habib, G.; Marshall, J.D.; Peltier, R.E. PM2.5 exposure in highly polluted cities: A case study from New Delhi, India. Environ. Res. 2017, 156, 167–174. [Google Scholar] [CrossRef] [PubMed]
  51. Sharma, D.; Jain, S. Reduction in black carbon concentration and its exposure in rural settings of Northern India: An intervention analysis. Chemosphere 2020, 247, 125838. [Google Scholar] [CrossRef]
  52. Sanchez, M.; Milà, C.; Sreekanth, V.; Balakrishnan, K.; Sambandam, S.; Nieuwenhuijsen, M.; Kinra, S.; Marshall, J.D.; Tonne, C. Personal exposure to particulate matter in peri-urban India: Predictors and association with ambient concentration at residence. J. Exp. Sci. Environ. Epidemiol. 2020, 30, 596–605. [Google Scholar] [CrossRef] [Green Version]
  53. Che, W.; Frey, H.C.; Fung, J.C.; Ning, Z.; Qu, H.; Lo, H.K.; Chen, L.; Wong, T.-W.; Wong, M.K.; Lee, O.C.; et al. PRAISE-HK: A personalized real-time air quality informatics system for citizen participation in exposure and health risk management. Sustain. Cities Soc. 2020, 54, 101986. [Google Scholar] [CrossRef]
  54. Shekarrizfard, M.; Faghih-Imani, A.; Hatzopoulou, M. An examination of population exposure to traffic related air pollution: Comparing spatially and temporally resolved estimates against long-term average exposures at the home location. Environ. Res. 2016, 147, 435–444. [Google Scholar] [CrossRef]
  55. Good, N.; Mölter, A.; Peel, J.L.; Volckens, J. An accurate filter loading correction is essential for assessing personal exposure to black carbon using an Aethalometer. J. Expo. Sci. Environ. Epidemiol. 2017, 27, 409–416. [Google Scholar] [CrossRef]
  56. Kirchstetter, T.W.; Novakov, T. Controlled generation of black carbon particles from a diffusion flame and applications in evaluating black carbon measurement methods. Atmos. Environ. 2007, 41, 1874–1888. [Google Scholar] [CrossRef]
  57. Hertel, O.; De Leeuw, F.A.A.M.; Jensen, S.S.; Gee, D.; Herbarth, O.; Pryor, S.; Palmgren, F.; Olsen, E.; Nielsen, O. Human exposure to outdoor air pollution (IUPAC Technical Report). Pure Appl. Chem. 2001, 73, 933–958. [Google Scholar] [CrossRef]
  58. Hinds, W.C. Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles; John Wiley & Sons: Hoboken, NJ, USA, 2012. [Google Scholar]
  59. Matz, C.J.; Stieb, D.M.; Brion, O. Urban-rural differences in daily time-activity patterns, occupational activity and housing characteristics. Environ. Health 2015, 14, 1–11. [Google Scholar] [CrossRef] [Green Version]
  60. Taneja, A.; Saini, R.; Masih, A. Indoor Air Quality of Houses Located in the Urban Environment of Agra, India. Ann. N. Y. Acad. Sci. 2008, 1140, 228–245. [Google Scholar] [CrossRef] [PubMed]
  61. Jeong, C.-H.; Salehi, S.; Wu, J.; North, M.L.; Kim, J.S.; Chow, C.-W.; Evans, G.J. Indoor measurements of air pollutants in residential houses in urban and suburban areas: Indoor versus ambient concentrations. Sci. Total Environ. 2019, 693, 133446. [Google Scholar] [CrossRef]
  62. Zuraimi, M.S.; Tham, K.-W.; Chew, F.-T.; Ooi, P.-L.; Koh, D. Home air-conditioning, traffic exposure, and asthma and allergic symptoms among preschool children. Pediatr. Allergy Immunol. 2011, 22, e112–e118. [Google Scholar] [CrossRef] [PubMed]
  63. Zuraimi, M.; Tham, K. Reducing particle exposures in a tropical office building using electrostatic precipitators. Build. Environ. 2009, 44, 2475–2485. [Google Scholar] [CrossRef]
  64. O’Connell, G.; Colard, S.; Cahours, X.; Pritchard, J.D. An Assessment of Indoor Air Quality before, during and after Unrestricted Use of E-Cigarettes in a Small Room. Int. J. Environ. Res. Public Health 2015, 12, 4889–4907. [Google Scholar] [CrossRef] [Green Version]
  65. Tong, Z.; Chen, Y.; Malkawi, A.; Adamkiewicz, G.; Spengler, J.D. Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building. Environ. Int. 2016, 89–90, 138–146. [Google Scholar] [CrossRef] [PubMed]
  66. Tran, L.K.; Quang, T.N.; Hue, N.T.; Van Dat, M.; Morawska, L.; Nieuwenhuijsen, M.; Thai, P.K. Exploratory assessment of outdoor and indoor airborne black carbon in different locations of Hanoi, Vietnam. Sci. Total Environ. 2018, 642, 1233–1241. [Google Scholar] [CrossRef] [PubMed]
  67. Adam, M.G.; Tran, P.T.; Bolan, N.; Balasubramanian, R. Biomass burning-derived airborne particulate matter in Southeast Asia: A critical review. J. Hazard. Mater. 2021, 407, 124760. [Google Scholar] [CrossRef]
  68. Kar, A.; Rehman, I.H.; Burney, J.; Puppala, S.P.; Suresh, R.; Singh, L.; Singh, V.K.; Ahmed, T.; Ramanathan, N.; Ramanathan, V. Real-Time Assessment of Black Carbon Pollution in Indian Households Due to Traditional and Improved Biomass Cookstoves. Environ. Sci. Technol. 2012, 46, 2993–3000. [Google Scholar] [CrossRef] [PubMed]
  69. Pope, D.; Bruce, N.; Higgerson, J.; Hyseni, L.; Stanistreet, D.; Mbatchou, B.; Puzzolo, E. Household Determinants of Liquified Petroleum Gas (LPG) as a Cooking Fuel in SW Cameroon. EcoHealth 2018, 15, 729–743. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  70. Karagulian, F.; Belis, C.A.; Dora, C.F.C.; Prüss-Ustün, A.M.; Bonjour, S.; Adair-Rohani, H.; Amann, M. Contributions to cities’ ambient particulate matter (PM): A systematic review of local source contributions at global level. Atmos. Environ. 2015, 120, 475–483. [Google Scholar] [CrossRef]
  71. Sharma, R.; Balasubramanian, R. Assessment and mitigation of indoor human exposure to fine particulate matter (PM2.5) of outdoor origin in naturally ventilated residential apartments: A case study. Atmos. Environ. 2019, 212, 163–171. [Google Scholar] [CrossRef]
  72. Martins, N.R.; da Graça, G.C. Impact of PM2.5 in indoor urban environments: A review. Sustain. Cities Soc. 2018, 42, 259–275. [Google Scholar] [CrossRef]
  73. Tran, P.T.; Nguyen, T.; Balasubramanian, R. Personal exposure to airborne particles in transport micro-environments and potential health impacts: A tale of two cities. Sustain. Cities Soc. 2020, 63, 102470. [Google Scholar] [CrossRef]
  74. Tran, P.T.M.; Ngoh, J.R.; Balasubramanian, R. Assessment of the Integrated Personal Exposure to Particulate Emissions in Urban Micro-environments: A Pilot Study. Aerosol Air Qual. Res. 2020, 20, 341–357. [Google Scholar] [CrossRef]
  75. Leavey, A.; Reed, N.; Patel, S.; Bradley, K.; Kulkarni, P.; Biswas, P. Comparing on-road real-time simultaneous in-cabin and outdoor particulate and gaseous concentrations for a range of ventilation scenarios. Atmos. Environ. 2017, 166, 130–141. [Google Scholar] [CrossRef] [Green Version]
  76. Hudda, N.; Eckel, S.P.; Knibbs, L.D.; Sioutas, C.; Delfino, R.J.; Fruin, S.A. Linking in-vehicle ultrafine particle exposures to on-road concentrations. Atmos. Environ. 2012, 59, 578–586. [Google Scholar] [CrossRef] [Green Version]
  77. Kumar, P.; Patton, A.P.; Durant, J.L.; Frey, H.C. A review of factors impacting exposure to PM2.5, ultrafine particles and black carbon in Asian transport microenvironments. Atmos. Environ. 2018, 187, 301–316. [Google Scholar] [CrossRef]
  78. Clausen, G. Ventilation filters and indoor air quality: A review of research from the International Centre for Indoor Environment and Energy. Indoor Air 2004, 14, 202–207. [Google Scholar] [CrossRef]
  79. Adam, M.G.; Chiang, A.W.J.; Balasubramanian, R. Insights into characteristics of light absorbing carbonaceous aerosols over an urban location in Southeast Asia. Environ. Pollut. 2020, 257, 113425. [Google Scholar] [CrossRef]
  80. See, S.; Balasubramanian, R. Characterization of fine particle emissions from incense burning. Build. Environ. 2011, 46, 1074–1080. [Google Scholar] [CrossRef]
  81. Loupa, G.; Karageorgos, E.; Rapsomanikis, S. Potential effects of particulate matter from combustion during services on human health and on works of art in medieval churches in Cyprus. Environ. Pollut. 2010, 158, 2946–2953. [Google Scholar] [CrossRef] [PubMed]
  82. Velasco, E.; Tan, S.H. Particles exposure while sitting at bus stops of hot and humid Singapore. Atmos. Environ. 2016, 142, 251–263. [Google Scholar] [CrossRef]
  83. See, S.W.; Balasubramanian, R. Chemical characteristics of fine particles emitted from different gas cooking methods. Atmos. Environ. 2008, 42, 8852–8862. [Google Scholar] [CrossRef]
  84. Lunden, M.M.; Kirchstetter, T.W.; Thatcher, T.L.; Hering, S.V.; Brown, N.J. Factors affecting the indoor concentrations of carbonaceous aerosols of outdoor origin. Atmos. Environ. 2008, 42, 5660–5671. [Google Scholar] [CrossRef] [Green Version]
  85. APnA. Air Pollution Knowledge Assessments for Indian Cities: Summary Report. Available online: http://www.urbanemissions.info/india-apna (accessed on 18 June 2020).
  86. Kilian, J.; Kitazawa, M. The emerging risk of exposure to air pollution on cognitive decline and Alzheimer’s disease–evidence from epidemiological and animal studies. Biomed. J. 2018, 41, 141–162. [Google Scholar] [CrossRef]
  87. Suglia, S.F.; Gryparis, A.; Wright, R.O.; Schwartz, J. Association of Black Carbon with Cognition among Children in a Prospective Birth Cohort Study. Am. J. Epidemiol. 2007, 167, 280–286. [Google Scholar] [CrossRef] [PubMed]
  88. Chiu, Y.-H.M.; Bellinger, D.C.; Coull, B.A.; Anderson, S.; Barber, R.; Wright, R.O.; Wright, R.J. Associations between Traffic-Related Black Carbon Exposure and Attention in a Prospective Birth Cohort of Urban Children. Environ. Health Perspect. 2013, 121, 859–864. [Google Scholar] [CrossRef] [PubMed]
  89. Tham, K.; Parshetti, G.; Balasubramanian, R.; Sekhar, C.; Cheong, D. Mitigating particulate matter exposure in naturally ventilated buildings during haze episodes. Build. Environ. 2018, 128, 96–106. [Google Scholar] [CrossRef]
  90. Tran, P.T.; Adam, M.G.; Balasubramanian, R. Mitigation of indoor human exposure to airborne particles of outdoor origin in an urban environment during haze and non-haze periods. J. Hazard. Mater. 2021, 403, 123555. [Google Scholar] [CrossRef]
  91. Sharma, R.; Balasubramanian, R. Indoor human exposure to size-fractionated aerosols during the 2015 Southeast Asian smoke haze and assessment of exposure mitigation strategies. Environ. Res. Lett. 2017, 12, 114026. [Google Scholar] [CrossRef]
  92. R Core Team. R: A Language and Environment for Statistical Computing; R Foundation for Statistical Computing: Vienna, Austria, 2020. [Google Scholar]
Figure 1. Map view highlighting Trivandrum; the red star highlights the residential home, whereas the blue star shows the location of the fixed monitoring site (2.1 km from the residential home), and (inset) overview of India.
Figure 1. Map view highlighting Trivandrum; the red star highlights the residential home, whereas the blue star shows the location of the fixed monitoring site (2.1 km from the residential home), and (inset) overview of India.
Ijerph 18 05028 g001
Figure 2. Time series of personal exposure to BC over 48 h for the home-based participant 1 (blue), and participant 2 during mobility-based exposure (red) and stationary PM2.5 (black) values.
Figure 2. Time series of personal exposure to BC over 48 h for the home-based participant 1 (blue), and participant 2 during mobility-based exposure (red) and stationary PM2.5 (black) values.
Ijerph 18 05028 g002
Figure 3. BC exposure for motorcycle, home, and car for the mobile participant.
Figure 3. BC exposure for motorcycle, home, and car for the mobile participant.
Ijerph 18 05028 g003
Figure 4. Daily integrated dose of BC during home-based exposure and during mobility-based exposure encompassing diverse MEs on representative days. Abbreviations: black carbon (BC), air conditioning (AC), microenvironments (MEs).
Figure 4. Daily integrated dose of BC during home-based exposure and during mobility-based exposure encompassing diverse MEs on representative days. Abbreviations: black carbon (BC), air conditioning (AC), microenvironments (MEs).
Ijerph 18 05028 g004
Table 1. BC personal exposure concentrations and ratio of mean BC concentrations from home-based (HB) and mobility-based (MB) participants (simultaneous measurement, the ratios are calculated pairwise) in different MEs in Trivandrum.
Table 1. BC personal exposure concentrations and ratio of mean BC concentrations from home-based (HB) and mobility-based (MB) participants (simultaneous measurement, the ratios are calculated pairwise) in different MEs in Trivandrum.
MetricHomeTransportRestaurant (NV)LeisureTempleBus stop
MotorcycleCarACNV
Conc.HB/MB ratioConc.HB/MB ratioConc.HB/MB ratioConc.HB/MB ratioConc.HB/MB ratioConc.HB/MB ratioConc.HB/MB ratio
AM10.1337.910.5825.750.6917.530.938.930.9611.831.1117.450.7412.111.45
AM SD8.8241.112.3430.720.8511.600.275.982.7712.490.605.830.545.080.34
GM8.2726.230.2917.490.4613.780.897.920.689.040.9516.580.5511.441.40
GM SD1.882.332.602.372.712.071.331.551.791.921.861.382.191.371.36
Max381.62381.6235.44288.1810.96101.372.1449.5233.16179.164.9135.771.7327.901.78
Min0.003.080.020.520.013.630.311.160.122.610.079.550.207.550.60
CI0.143.660.292.290.090.710.020.700.460.610.041.740.232.170.20
Leisure NV: community centers, vegetable store. Leisure AC: supermarket, photostudio, bakery, polyclinics. Abbreviations: home-based (HB), mobility-based (MB), arithmetic mean (AM), arithmetic mean standard deviation (AM SD), geometric mean (GM), geometric mean standard deviation (GM SD), confidence interval (CI).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Adam, M.G.; Tran, P.T.M.; Cheong, D.K.W.; Chandra Sekhar, S.; Tham, K.W.; Balasubramanian, R. Assessment of Home-Based and Mobility-Based Exposure to Black Carbon in an Urban Environment: A Pilot Study. Int. J. Environ. Res. Public Health 2021, 18, 5028. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18095028

AMA Style

Adam MG, Tran PTM, Cheong DKW, Chandra Sekhar S, Tham KW, Balasubramanian R. Assessment of Home-Based and Mobility-Based Exposure to Black Carbon in an Urban Environment: A Pilot Study. International Journal of Environmental Research and Public Health. 2021; 18(9):5028. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18095028

Chicago/Turabian Style

Adam, Max Gerrit, Phuong Thi Minh Tran, David Kok Wai Cheong, Sitaraman Chandra Sekhar, Kwok Wai Tham, and Rajasekhar Balasubramanian. 2021. "Assessment of Home-Based and Mobility-Based Exposure to Black Carbon in an Urban Environment: A Pilot Study" International Journal of Environmental Research and Public Health 18, no. 9: 5028. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18095028

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop