Next Article in Journal
Size-Dependent Mechanical Properties of Amorphous SiO2 Nanowires: A Molecular Dynamics Study
Next Article in Special Issue
Assessment of Effects of Laser Light Combining Three Wavelengths (450, 520 and 640 nm) on Temperature Increase and Depth of Tissue Lesions in an Ex Vivo Study
Previous Article in Journal
Compression-Induced Tensile Mechanical Behaviors of the Crystalline Rock under Dynamic Loads
Previous Article in Special Issue
Removal of Composite Restoration from the Root Surface in the Cervical Region Using Er: YAG Laser and Drill—In Vitro Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Dental Aerosol as a Hazard Risk for Dental Workers

1
Laser Laboratory, Oral Surgery Department, Wroclaw Medical University, 50-367 Wroclaw, Poland
2
Department of Periodontics School of Dentistry, Virginia Commonwealth University, VCU, Richmond, VA 23298, USA
*
Author to whom correspondence should be addressed.
Submission received: 23 October 2020 / Revised: 5 November 2020 / Accepted: 9 November 2020 / Published: 12 November 2020
(This article belongs to the Collection Laser Processing for Bioengineering)

Abstract

:
Standard dental procedures, when using a water coolant and rotary instruments, generate aerosols with a significantly higher number of various dangerous pathogens (viruses, bacteria, and fungi). Reducing the amount of aerosols to a minimum is mandatory, especially during the new coronavirus disease, COVID-19. The study aimed to evaluate the amount of aerosol generated during standard dental procedures such as caries removal (using dental bur on a high and low-speed handpiece and Er:YAG laser), ultrasonic scaling, and tooth polishing (using silicon rubber on low-speed handpiece) combined with various suction systems. The airborne aerosols containing particles in a range of 0.3–10.0 μm were measured using the PC200 laser particle counter (Trotec GmbH, Schwerin, Germany) at three following sites, manikin, operator, and assistant mouth, respectively. The following suction systems were used to remove aerosols: saliva ejector, high volume evacuator, saliva ejector with extraoral vacuum, high volume evacuator with extraoral vacuum, Zirc® evacuator (Mr.Thirsty One-Step®), and two customized high volume evacuators (white and black). The study results showed that caries removal with a high-speed handpiece and saliva ejector generates the highest amount of spray particles at each measured site. The aerosol measurement at the manikin mouth showed the highest particle amount during caries removal with the low and high-speed handpiece. The results for the new high volume evacuator (black) and the Zirc® evacuator showed the lowest increase in aerosol level during caries removal with a high-speed handpiece. The Er:YAG laser used for caries removal produced the lowest aerosol amount at the manikin mouth level compared to conventional dental handpieces. Furthermore, ultrasonic scaling caused a minimal aerosol rise in terms of the caries removal with bur. The Er:YAG laser and the new wider high volume evacuators improved significantly suction efficiency during dental treatment. The use of new suction systems and the Er:YAG laser allows for the improvement of biological safety in the dental office, which is especially crucial during the COVID-19 pandemic.

1. Introduction

Dental professionals are considered as the workers who are most exposed to infection with the coronaviruses family, which causes the common cold to severe respiratory infections, like the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), in humans [1] (Figure 1). The primary transmission routes appear to be direct mucous membrane (eyes, nose, and oral cavity) contact with contagious respiratory bioaerosol. Many authors showed that during dental treatment a high amount of aerosol has been produced [2,3,4,5]. The dental aerosol with the most considerable concentration and extension is visible when using all rotary instruments (high and low-speed handpieces), air abrasion, or ultrasonic scalers. During dental treatment, sources of airborne contamination are saliva, dental instrumentation, respiratory sources, and the operative site. The potential for transmitting almost invisible aerosol and the virus infection spreading is so high; thus, dentists should recognize and minimize or even eliminate this risk within all clinical situations, especially when patients are in the incubation period, are unaware they are infected, or choose to conceal their disease.
Many procedures from the dental field like caries removal, periodontal supragingival scaling, and prosthodontics tooth preparation is associated with aerosol and splatter formation. The aerosol is composed of liquid and solid particles with a diameter of 50 μm or less, which are suspended in the air. Splatter is usually described as a mixture of air with water and/or solid substance in which water droplets are bigger than 50 μm [6]. Particular attention should be paid to eliminating aerosol particles in the range of 0.5–10 μm diameter, which can be inhaled and held on the human lung’s terminal bronchioles and alveoli [7]. The aerosol generated in the dental office during the treatment occurs in three forms. The first type of bioaerosol is contagious respiratory aerosol resulting from respiratory action, and the ballistic discharge of bronchial secretions during sneezing or coughing [4]. The second is a pure water-air mist produced by rotary instruments, scalers, piezoelectric units, or air abrasive devices. The third form is a mixture consisting of a heavily diluted aerosol spray with a respiratory bioaerosol that could potentially spread the virus for a greater distance.
The positive effect of lasers in dentistry has been proven in the scientific literature regarding different treatment modality and eliminating the virus, bacteria, and fungi [8,9,10,11,12,13,14,15,16,17,18]. Some lasers produce an aerosol or induce a bubble formation in fluids (cavitation effect) [19,20,21,22,23]. The erbium lasers are widely used for different dental procedures, including caries removal, endodontic irrigation, periodontal and implant treatment or orthodontic brackets, or prosthetic crown debonding [19,24,25,26,27]. Globally, it has been increasing awareness of the potential health risk of laser generating aerosol. Comparatively, typically respiratory droplets have a bigger size particle (usually in micrometers) than smaller viruses (in nanometers). Generally, viruses are much smaller than the cells they infect. Literature confirmed using lasers in dentistry to viruses inactivation [9,10,28,29,30]. Worth attention is the fact that laser generating heat and soft tissue vaporization, leads to smoke production, which could contain infectious particles [8,9].
Up to date, there is no evidence available on what level of the aerosolized coronavirus SARS-CoV-2 generated during dental procedures can be a source of infection. The infectious dose has not yet been determined, nor has the level of potential virulence for the enormously diluted mixed bioaerosol in dentistry been discovered. However, the virus’s ability to infect the human is directly dependent on the number of virus particles [31]. The study of Carter et al. and Seal et al. [32] found dependence in colds and other respiratory illness incidences among naval recruits and the dental professionals who treated them. Notably, the dental team needs to minimize the risk of infection during scheduled dental treatment, the methods of elimination of the third form of the aerosol (a mixture of bioaerosol and water spray) by applying the high efficient suction systems.
A systematic review of aerosol-generating procedures concerning SARS was summarized in the 2014 WHO guideline [33]. The review described the risk factors, basic properties of aerosols generated during routine dental procedures, ways in which dental aerosols are generated, and the types of pathogens they can harbor. The important conclusion from the recommendations is that dental treatment with the lowest aerosol generation is demanded and indicated. Various methods are explained in the scientific literature to reduce the hazard produced due to bioaerosols, e.g., hand protection (gloves), body protection (medical apron, caps, and footwear), eye protection (safety glasses, goggles, and face shield), face mask, ventilation system, ultraviolet filters and lamps, automated room disinfection (ARD) systems with hydrogen peroxide vapor, and high-volume evacuators (HVE) [4,7]. However, minimal data is available regarding the effectiveness of high-volume evacuators in dentistry.
The study aims to evaluate the aerosol generation during standard dental procedures, such as caries removal, dental scaling, and polishing, using the different suction systems, such as a saliva ejector and various high-volume evacuators. Additionally, the effect of an erbium laser and external vacuum on aerosol reduction was assessed.

2. Materials and Methods

A three-dimensional manikin model with natural tooth (number 35 in the FDI system, number 20 in the Universal system, and the American system) was used to mimic the everyday working conditions in dental offices. The airborne aerosols were measured at the selected sampling sites (1) next to the open mouth of the patient (manikin), (2) mouth position of the dental operator, and (3) mouth position of the dental assistant; Figure 2).

2.1. Measurement Method

Measurement of the aerosol at the assessed positions was done with the PC200 laser particle counter (Trotec GmbH, Schwerin, Germany). The sensor was placed at a distance of 2 cm, 40 cm, and 40 cm from the treatment area. The six different particle sizes (0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, and 10.0 µm) were measured during the experiment. Next, the particles in a range of 0.3–10.0 µm were summarized to receive the total amount of collected aerosol particles. The measurement at each site was repeated six times. The measurement device (The particle sensor) was turned on 60 s after each treatment was started. The time during the experiment was measured with a stopwatch. The mean results of each measurement were used for the statistical analysis (Figure 3).

2.2. The Office Air Standardization

The air conditioning system was turned off, and windows closed to achieve similar office air properties. Each measurement was conducted in a similar air environment at a stable number of particles in a range of 28,000–30,000. When the number of the particles in the air was out the assumed stable range, the air purifier system (NV1050, Novaerus, Ireland) with an air exchange of 800 m3 per hour was turned on to clean the air to the proper particles level prior to the measurements. The measurement of the air particles in the room was conducted in the central part of the office. The average time to purify the air to the demanded particle range in the office (20 m2) was around 5 min.

2.3. Suction Systems

The aerosol produced when applying different dental procedures was removed by the following suction systems/modalities: (Figure 4)
  • Saliva ejector EM15 (Monoart® Euronda, Vicenza, Italy);
  • High volume evacuator EM19 EVO (Monoart® Euronda, Vicenza, Italy);
  • Saliva ejector EM15 (Monoart® Euronda, Vicenza, Italy) with an extraoral vacuum (MAcURAY PRO, KTMAX Inc., Seoul, Korea);
  • High volume evacuator EM19 EVO (Monoart® Euronda, Vicenza, Italy) with an extraoral vacuum (MAcURAY PRO, KTMAX Inc., Seoul, Korea);
  • Zirc evacuator Mr. Thirsty One-step® (Loser, Zirc, Buffalo, USA);
  • Customized high volume evacuator (white)—designed and prepared by the authors;
  • Customized high volume evacuator (black)—designed and prepared by the authors.

2.4. Dental Procedures

The assessment of the aerosol level was conducted during the standard dental procedures (without rubber dam) such as:
  • Treatment of caries class I with the round diamond bur (#014) with a high-speed handpiece W&H Synea TA-98LC (W&H, Bürmoos, Austria) and all seven suction modalities (Figure 4A–G). Working parameters: 200,000 RPM (revolutions per minute), water cooling: 30 mL/min;
  • Treatment of caries class I with the round rose bur (#014) with a low-speed handpiece W&H Synea TA-98LC (W&H, Bürmoos, Austria) and saliva ejector EM15 or high volume evacuator EM19 EVO. Working parameters: 15,000 RPM (revolutions per minute), water cooling: 30 mL/min;
  • Treatment of caries class I with 1 mm diameter sapphire tip with a handpiece H14 of Er:YAG laser (LightWalker, Fotona, Slovenia) and saliva ejector EM15 or high volume evacuator EM19 EVO. Laser parameters: energy 300 mJ, frequency 20 Hz, power 6 W, water/air coolant 6/4;
  • Tooth polishing with silicone rubber dental bur (Kenda AG, Vaduz, Liechtenstein) with a low-speed handpiece W&H Synea TA-98LC (W&H, Bürmoos, Austria) at 1000 and 10,000 RPM (revolutions per minute) and saliva ejector EM15 or high volume evacuator EM19 EVO. Water cooling: 30 mL/min;
  • Dental calculus removal using ultrasound scaler HW-3H (Woodpecker Medical Instrument Co., Ltd., Guilin, China) and saliva ejector EM15 or high volume evacuator EM19 EVO at a power of 30%, water cooling: 40 mL/min.

2.5. Statistical Analysis

The amount of the dental aerosol during different dental procedures with a low and high-speed handpiece, scaler, and using suction devices, measured in 3 areas, was compared with the analysis of variance and post-hoc tests (multiple comparisons using the Tukey test). The statistical analysis was conducted by using Statistica software (StatSoft, Tulsa, OK, USA). Values below p = 0.05 were considered to be statistically significant.

3. Results

3.1. High Volume Evacuators Significantly Reduced the Aerosols during Caries Removal with the Use of a High-Speed Handpiece. The New Custom-Designed High Volume Evacuators and the Zirc® Evacuator Proved to be the Most Effective

The level of the aerosol measured at the manikin mouth was significantly higher than around the dental assistant or operator’s mouth during caries removal with a high-speed handpiece and saliva ejector, saliva ejector + extraoral vacuum, high volume evacuator alone, and with the extraoral vacuum (p < 0.001). The exception was when the classic high-pressure evacuator with external vacuum, Zirc® evacuator, and the new black and white high volume evacuators were used. The results for the new high volume evacuator (black) and the Zirc® evacuator showed the lowest increase of the aerosol level in terms of the particle spray level in the air without significant differences between measured sites. Importantly, the Zirc® evacuator and both new designed high volume evacuators significantly reduced aerosol levels measured at the manikin mouth and operator level in contrast to conventional suction systems (saliva ejector and high volume evacuator) alone and in combination with an extraoral vacuum (p < 0.001; Table 1).

3.2. High Volume Evacuator Significantly Reduced the Aerosols during Caries Removal with the Use of a Low-Speed Handpiece. The Low-Speed Handpiece Produced Less Aerosols than a High-Speed Turbine

Caries removal with the dental bur and a low-speed handpiece in combination with the saliva ejector and classic high volume evacuator showed the highest aerosol level at the manikin mouth and its significant decrease at the operator and assistant mouth, respectively (p < 0.001; Figure 5). Moreover, the high volume evacuator decreased the amount of aerosol at the manikin mouth and operator level approximately fourth and three times in contrast to the saliva ejector, respectively. Caries removal with a low-speed handpiece resulted in significantly lower aerosol particles in contrast to a high-speed turbine.

3.3. Er:YAG Laser Significantly Reduced the Aerosols during Caries Removal as Compared with Classical Rotary Handpieces

Er:YAG laser with classic high volume evacuator generated significantly less aerosol than the high-speed handpiece combined with a saliva ejector, saliva ejector + extraoral vacuum, high volume evacuator alone and with extraoral vacuum, and the low-speed handpiece with saliva ejector and high volume evacuator during caries removal at manikin (mean 28.6 ± 1.3), operator (mean 29.2 ± 0.8), and assistant (mean 29.0 ± 1.1) mouth levels (p < 0.001). The level of the aerosol measured around the manikin mouth was significantly lower than at operator mouth level during caries removal with Er:YAG laser with the saliva ejector and the high volume evacuator (p < 0.01). The rise in the amount of aerosol at the assistant level in contrast to the manikin was insignificant (p > 0.05; Figure 6).

3.4. Polishing the Tooth with Silicone Rubber Dental bur with a Low-Speed Contra-Angle Generated the Highest Amount of Aerosol Particles

Tooth polishing with the low-speed handpiece and silicone rubber dental bur resulted in significantly highest aerosol particles number in contrast to other treatment procedures. The level of dental spray measured around the mouth of the manikin when cleaning/polishing the tooth with silicone rubber dental bur with a low-speed contra-angle handpiece was significantly higher than that measured around the operator and assistant mouth level at 1000 and 10,000 RPM, respectively (p < 0.001). Increasing the RPM of the low-speed handpiece from 1000 to 10,000 with the high volume evacuator significantly reduced the amount of aerosol at the manikin’s mouth in contrast to the saliva ejector (p < 0.001; Table 2).

3.5. Ultrasonic Scaling Generated Less Aerosols then Caries Removal and Tooth Polishing Using Conventional Rotary Handpieces and Traditional Suction Systems (Saliva Ejector and High Volume Evacuator)

Ultrasonic scaling produced lower aerosols amount compared to caries removal using conventional rotary handpieces and tooth polishing with a low-speed handpiece combined with a saliva ejector and high volume evacuator (p < 0.001). High volume evacuator significantly decreased the aerosol level at the manikin (p = 0.005) and operator (p = 0.003) levels during the ultrasound scaling in contrast to the saliva ejector. Intragroup comparison of the level of aerosol measured at different sensor locations showed insignificant differences (p < 0.05; Table 3).

4. Discussion

Dental office personnel working in the patient’s respiratory tract are constantly exposed to potentially infectious bioaerosols [34]. Working high and low-speed handpieces pose a special risk, increasing transmissions of potentially dangerous pathogens (bacteria, viruses, and fungus) in a mixture of bioaerosol with a water spray. The results of the study showed that caries removal with a high-speed handpiece and saliva ejector generated the highest amount of spray particles at each measured site. The measurement of aerosol at the manikin mouth showed the highest particle amount during caries removal with the low and high-speed handpiece. The results for the new high volume evacuator (black) and the Zirc evacuator showed the lowest increase of aerosol level during caries removal with a high-speed handpiece. The Er:YAG laser used for caries removal produced the lowest aerosol amount at the manikin zone in contrast to both conventional dental handpieces. Furthermore, ultrasonic scaling caused a minimal aerosol rise in terms of the initial office air particle level with no differences among measured areas. The rise of aerosols when using air turbine or the ultrasonic scaler with air–water spray coolant was confirmed in various previously published studies [5,7,35,36].
A dental treatment, especially when using a high-speed turbine, generates a high amount of aerosol and splatter, possibly contaminated with bacteria, viruses, fungi, and blood [37]. Aerosols with a diameter below 50 µm remained in the office air for a prolonged time and could be inhaled by dental personnel and the patients [6]. Dental aerosol contains potentially hazardous particulate matter of submicron size smaller than 10 μm (PM10). [38,39] The more aerosol particles in the air, the higher the risk of infection is. Thus, the main target to reduce the hazard of aerosol transmission in the dental office seems to be to diminish the amount of the aerosol during common dental treatments. Conventionally the saliva ejectors are used to remove water and saliva from the oral cavity. However, these tips have a low potential of removing the aerosolized particles when using high and low speed contra-angles. The greater suction efficiency has high volume evacuators. These devices have wider tips and allow removing even 90% of particles [36]. However, the main disadvantage of the system is that it must be in very near contact with a tooth to work with high efficiency.
The main aim of the study was to answer the question: is it possible to reduce the aerosol and splatter amount produced during standard dental procedures (caries removal and ultrasonic scaling) with higher efficiency than conventional high volume evacuator and saliva ejector. The results of our study for caries removal with a high-speed contra-angle handpiece showed that wider suction systems (customized evacuators) allowed removing of 2 and 8 times more aerosols when compared with a high volume evacuators and a saliva ejector, respectively. The study of Jacks [36] showed that the high volume evacuators removed approximately 90% of aerosols during ultrasonic scaling when compared to the intraorally positioned standard saliva ejector. In our present study, the additional benefit to HVE provided extraoral evacuators, which reduced the aerosols by 33%. Additionally, better efficiency (88%) in aerosols reduction during caries removal using a high-speed turbine showed Zirc evacuator (32.1 ± 2.0) in contrast to HVE (60.5 ± 3.0). It should be mentioned that all the study was conducted without a rubber dam placement. The rubber dam may affect the amount of aerosol, but most importantly, it will limit the contact of water-air spray with mucous membranes, which increases the safety of the procedure. However, it is not always possible to place a rubber dam (not fully erupted teeth), children, people with respiratory disorders (severe asthma and breathing trouble through the nose), and special care patients.
The second important subject of the study was to assess whether ultrasonic scaling significantly increases the aerosol particles in the air of the office. Graetz et al. in their study [40] showed that ultrasonic and sonic devices are useful in eliminating biofilm but bear a greater risk to the dental workers concerning the production of splatter. Furthermore, Harrel et al. [41] observed that ultrasonic scalers, even when working without coolant, could spread the airborne material for at least 18 inches from the operative site [4]. The more considerable amount of aerosol and splatter can be formed from saliva and blood placed in the operative site. Our study results showed that if ultrasonic scaling was applied with a high volume evacuator, the increase of aerosol in terms of the mean particle amount in the office air was minimal. Less aerosol was generated during ultrasonic scaling when compared to the saliva ejector. Our study showed that aerosol produced during ultrasonic scaling was significantly less than during other procedures when using rotary instruments. Thus, ultrasonic scaling seemed to have less potential in pathogen transmission as compared to caries removal. Additionally, the high volume evacuator allowed the remaining aerosol to be similar to this level at the starting point of the experiment (2800–3000 particles).
The important issue was to assess the aerosol level when the Er:YAG laser was used for caries removal. The Er:YAG laser with the wavelength of 2940 um has the highest absorption in the water; hence it can be used to remove both hard and soft tissue [16,24,25,26,27]. In the study, we used the Er:YAG laser at recommending by manufacturer settings (energy 300 mJ, frequency 20 Hz, power 6 W, and water/air coolant 6/4). An important finding of the study was that the Er:YAG laser with a high volume evacuator generated significantly less aerosol than the high-speed handpiece combined with a saliva ejector, saliva ejector + extraoral vacuum, high volume evacuator alone and with extraoral vacuum, and the low-speed handpiece with saliva ejector and high volume evacuator during caries removal at manikin (mean 28.6 ± 1.3), operator (mean 29.2 ± 0.8), and assistant (mean 29.0 ± 1.1) mouth levels. Contrary to our aerosol generation results by Er:YAG laser, Guderian et al. found excessive aerosol release during CO2 laser application. That can indicate additional benefit in using erbium family lasers compared to CO2 in terms of decreasing biohazard in the dental office [42]. Although the laser works through the water components vaporization in the target tissue, the explosion effect has a limited range; thus, the aerosol formed during this process is lower in contrast to traditional methods of caries removal [21]. This is a possible explanation of lower aerosol formation obtained during caries removal with the Er:YAG laser. Furthermore, the interaction of the laser light with the target tissue also could have some additional benefit in the reduction of the risk of infection in dentistry.
In dental offices, rotary devices produce a large amount of aerosols containing parts of the tooth, saliva, blood, and many dangerous micropathogens during operation. One way to reduce the risk of infection with the SARS-CoV-2 virus was to close dental offices or admit patients on an emergency basis. However, this limited patient availability to dental services could also have the potential adverse effect of overuse of painkillers [43]. Many methods of disinfecting surfaces and air in dental offices (ozonation and fumigation with hydrogen peroxide) to maintain biological safety in the office are proposed [34]. The World Dental Federation (FDI) also recommended using Type FFP2 and FFP3 masks and a full protective apron while working [33]. Based on our findings presented in the paper, it is also essential to reduce the amount of aerosols during the dentist’s work by using highly efficient suction systems and modern devices that generate less aerosols during their operation. Our present study showed a significantly lower formation of aerosols during caries’ removal with the Er:YAG laser. The disadvantage of this method is the high cost of the device itself. However, wider dental high volume evacuators, profiled in such a way that partially embraced the head of a classic dental handpiece, allows an inexpensive and efficient reduction of aerosols when working in the oral cavity. An additional advantage of this solution is the possibility of the operator working without assistance because the wider high volume evacuator’s back surface also supports buccal tissues in the treatment area. However, additional studies should be done to check the virus inactivation potential during caries removal with the Er:YAG laser. A future great perspective for the laser light and potential work with the safety recommendation like being good in size and the shape of high-volume evacuators is promising, particularly in the current COVID-19 pandemic.

5. Conclusions

The most intensive dental aerosol is presenting during work with a high-speed handpiece or ultrasound scaler. We are obliged to reduce the probability of infection transmission during dental procedures and preserve all dental office workers and patients. The results showed that the amount of aerosol generated during caries removal, tooth polishing, and ultrasonic scaling was strictly connected with the method/device used in each procedure and significantly with the suction device. The main finding of the study confirmed that high volume evacuators allowed removing a significant amount of aerosol. The highest efficiency in aerosol reduction was obtained for wider customized high-volume evacuators. Additionally, the Er:YAG laser utilized for caries removal was characterized by a low aerosol generation even when working combined with saliva ejector. We do not recommend to use saliva ejector alone during tooth polishing with silicone rubber dental bur, ultrasonic scaling, and when treating caries conventionally.

Author Contributions

Conceptualization, methodology, investigation, writing—original draft preparation, writing—review and editing: together J.M. and K.G.-L. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. AFL. As Albertans Return to Work, Who Is at the Highest Risk of Exposure to the Novel Coronavirus? Available online: https://www.afl.org/as_albertans_return_to_work_who_is_at_the_highest_risk_of_exposure_to_the_novel_coronavirus (accessed on 10 August 2020).
  2. Ahmed, M.A.; Jouhar, R.; Ahmed, N.; Adnan, S.; Aftab, M.; Zafar, M.S.; Khurshid, Z. Fear and Practice Modifications among Dentists to Combat Novel Coronavirus Disease (COVID-19) Outbreak. Int. J. Environ. Res. Public Health 2020, 17, 2821. [Google Scholar] [CrossRef]
  3. Miller, R.L. Characteristics of Blood-Containing Aerosols Generated by Common Powered Dental Instruments. Am. Ind. Hyg. Assoc. J. 1995, 56, 670–676. [Google Scholar] [CrossRef] [PubMed]
  4. Harrel, S.K.; Molinari, J. Aerosols and splatter in dentistry: A brief review of the literature and infection control implications. J. Am. Dent. Assoc. 2004, 135, 429–437. [Google Scholar] [CrossRef] [PubMed]
  5. Bentley, C.D.; Burkhart, N.W.; Crawford, J.J. Evaluating spatter and aerosol contamination during dental procedures. J. Am. Dent. Assoc. 1994, 125, 579–584. [Google Scholar] [CrossRef] [PubMed]
  6. Coulthard, P. Dentistry and coronavirus (COVID-19)—Moral decision-making. Br. Dent. J. 2020, 228, 503–505. [Google Scholar] [CrossRef] [PubMed]
  7. Micik, R.E.; Miller, R.L.; Mazzarella, M.A.; Ryge, G. Studies on Dental Aerobiology: I. Bacterial Aerosols Generated during Dental Procedures. J. Dent. Res. 1969, 48, 49–56. [Google Scholar] [CrossRef]
  8. Garden, J.M.; Kerry O’Banion, M.; Bakus, A.D.; Olson, C. Viral disease transmitted by laser-generated plume (aerosol). Arch. Dermatol. 2002, 138, 1303–1307. [Google Scholar] [CrossRef]
  9. Garden, J.M.; O’Banion, M.K.; Shelnitz, L.S.; Pinski, K.S.; Bakus, A.D.; Reichmann, M.E.; Sundberg, J.P. Papillomavirus in the Vapor of Carbon Dioxide Laser-Treated Verrucae. J. Urol. 1989, 141, 223–224. [Google Scholar] [CrossRef]
  10. Hughes, P.S.H.; Hughes, A.P. Absence of human papillomavirus DNA in the plume of erbium:YAG laser-treated warts. J. Am. Acad. Dermatol. 1998, 38, 426–428. [Google Scholar] [CrossRef]
  11. Grzech-Leśniak, K.; Nowicka, J.; Pajączkowska, M.; Matys, J.; Szymonowicz, M.; Kuropka, P.; Rybak, Z.; Dobrzyński, M.; Dominiak, M. Effects of Nd:YAG laser irradiation on the growth of Candida albicans and Streptococcus mutans: in vitro study. Lasers Med. Sci. 2019, 34, 129–137. [Google Scholar] [CrossRef]
  12. Flieger, R.; Gedrange, T.; Grzech-Leśniak, K.; Dominiak, M.; Matys, J. Low-Level Laser Therapy with a 635 nm Diode Laser Affects Orthodontic Mini-Implants Stability: A Randomized Clinical Split-Mouth Trial. J. Clin. Med. 2019, 9, 112. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Nammour, S.; El Mobadder, M.; Maalouf, E.; Namour, M.; Namour, A.; Rey, G.; Matamba, P.; Matys, J.; Zeinoun, T.; Grzech-Leśniak, K. Clinical Evaluation of Diode (980 nm) Laser-Assisted Nonsurgical Periodontal Pocket Therapy: A Randomized Comparative Clinical Trial and Bacteriological Study. Photobiomodul. Photomed. Laser Surg. 2020. [Google Scholar] [CrossRef] [PubMed]
  14. Matys, J.; Grzech-Leśniak, K.; Flieger, R.; Dominiak, M. Assessment of an impact of a diode laser mode with wavelength of 980 nm on a temperature rise measured by means of k-02 thermocouple: Preliminary results. Dent. Med. Probl. 2016, 53, 341–351. [Google Scholar] [CrossRef] [Green Version]
  15. Grzech-Leśniak, K. Making Use of Lasers in Periodontal Treatment: A New Gold Standard? Photomed. Laser Surg. 2017, 35, 513–514. [Google Scholar] [CrossRef]
  16. Grzech-Leśniak, K.; Matys, J.; Jurczyszyn, K.; Ziółkowski, P.; Dominiak, M.; Brugnera, A., Jr.; Romeo, U. Histological and Thermometric Examination of Soft Tissue De-Epithelialization Using Digitally Controlled Er:YAG Laser Handpiece: An Ex Vivo Study. Photomed Laser Surg. 2018, 36, 313–319. [Google Scholar] [CrossRef]
  17. Grzech-Leśniak, K.; Gaspirc, B.; Sculean, A. Clinical and microbiological effects of multiple applications of antibacterial photodynamic therapy in periodontal maintenance patients. A randomized controlled clinical study. Photodiagnosis Photodyn. Ther. 2019, 27, 44–50. [Google Scholar] [CrossRef]
  18. Grzech-Leśniak, K.; Matys, J.; Dominiak, M. Comparison of the clinical and microbiological effects of antibiotic therapy in periodontal pockets following laser treatment: An in vivo study. Adv. Clin. Exp. Med. 2018, 27, 1263–1270. [Google Scholar] [CrossRef] [Green Version]
  19. Deeb, J.G.; Grzech-Leśniak, K.; Weaver, C.; Matys, J.; Bencharit, S. Retrieval of Glass Fiber Post Using Er:YAG Laser and Conventional Endodontic Ultrasonic Method: An In Vitro Study. J Prosthodont. 2019, 28, 1024–1028. [Google Scholar] [CrossRef]
  20. Matys, J.; Flieger, R.; Dominiak, M. Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study. Biomed. Res. Int. 2016, 2016, 1–8. [Google Scholar] [CrossRef] [Green Version]
  21. Zakrzewski, W.; Dobrzynski, M.; Kuropka, P.; Matys, J.; Malecka, M.; Kiryk, J.; Rybak, Z.; Dominiak, M.; Grzech-Leśniak, K.; Wiglusz, K.; et al. Removal of Composite Restoration from the Root Surface in the Cervical Region Using Er: YAG Laser and Drill-In Vitro Study. Materials 2020, 7, 3027. [Google Scholar] [CrossRef]
  22. Matys, J.; Romeo, U.; Mroczka, K.; Grzech-Leśniak, K.; Dominiak, M. Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study. Materials 2019, 14, 3748. [Google Scholar] [CrossRef] [Green Version]
  23. Flieger, R.; Matys, J.; Dominiak, M. The best time for orthodontic treatment for Polish children based on skeletal age analysis in accordance to refund policy of the Polish National Health Fund (NFZ). Adv. Clin. Exp. Med. 2018, 27, 1377–1382. [Google Scholar] [CrossRef] [PubMed]
  24. Grzech-Leśniak, K.; Bencharit, S.; Dalal, N.; Mroczka, K.; Deeb, J.G. In Vitro Examination of the Use of Er:YAG Laser to Retrieve Lithium Disilicate Crowns from Titanium Implant Abutments. J. Prosthodont. 2019, 28, 672–676. [Google Scholar] [CrossRef] [PubMed]
  25. Deeb, J.G.; Bencharit, S.; Dalal, N.; Abdulmajeed, A.; Grzech-Leśniak, K. Using Er:YAG laser to remove lithium disilicate crowns from zirconia implant abutments: An in vitro study. PLoS ONE 2019, 14, 1–12. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Grzech-Leśniak, K.; Matys, J.; Zmuda-Stawowiak, D.; Mroczka, K.; Dominiak, M.; Brugnera, A.; Gruber, R.; Romanos, G.E.; Sculean, A. Er:YAG Laser for Metal and Ceramic Bracket Debonding: An In Vitro Study on Intrapulpal Temperature, SEM, and EDS Analysis. Photomed. Laser Surg. 2018, 36, 595–600. [Google Scholar] [CrossRef] [PubMed]
  27. Grzech-Leśniak, K.; Sculean, A.; Gašpirc, B. Laser reduction of specific microorganisms in the periodontal pocket using Er:YAG and Nd:YAG lasers: a randomized controlled clinical study. Lasers Med. Sci. 2018, 33, 1461–1470. [Google Scholar] [CrossRef] [PubMed]
  28. Tsen, S.; Chapa, T.; Beatty, W.; Xu, B.; Tsen, K.; Achilefu, S. Ultrashort pulsed laser treatment inactivates viruses by inhibiting viral replication and transcription in the host nucleus. Antiviral Res. 2014, 110, 70–76. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  29. Fekrazad, R. Photobiomodulation and Antiviral Photodynamic Therapy as a Possible Novel Approach in COVID-19 Management. Photobiomod. Photomed. Laser Surg. 2020, 38, 1–3. [Google Scholar] [CrossRef]
  30. Schikora, D.; Hepburn, J.; Plavin, S. Reduction of the Viral Load by Non-Invasive Photodynamic Therapy in Early Stages of COVID-19 infection. Am J Viro Dis. 2020, 2, 1–5. [Google Scholar]
  31. Atkinson, J.; Chartier, Y.; Lúcia Pessoa-Silva, C.; Jensen, P.; Li, Y.; Seto, W.-H. Natural Ventilation for Infection Control in Health-Care Settings WHO Library Cataloguing-in-Publication Data: Natural Ventilation for Infection Control in Health-Care Settings; WHO: Geneva, Switzerland, 2009. [Google Scholar]
  32. Carter, W.J.; Seal, J.R. Upper Respiratory Infections in Dental Personnel and Their Patients; Research Project Report NMOO50511403. Naval Medical Research Unit No.4; Administrative Command, US Naval Training Center: Great Lakes, IL, USA, 1953. [Google Scholar]
  33. WHO. Infection Prevention and Control of Epidemic-and Pandemic Prone Acute Respiratory Infections in Health Care; WHO: Geneva, Switzerland, 2014. [Google Scholar]
  34. Matys, J.; Grzech-Leśniak, K.; Dominiak, M. Disinfectants and devices for surface and air disinfection in dental offices. J. Stomatol. 2020, 73, 200–205. [Google Scholar] [CrossRef]
  35. Seto, W.H. Airborne transmission and precautions: Facts and myths. J. Hosp. Infect. 2015, 89, 225–228. [Google Scholar] [CrossRef] [PubMed]
  36. Jacks, M.E. A laboratory comparison of evacuation devices on aerosol reduction. J Dent Hyg. 2002, 76, 202–206. [Google Scholar] [PubMed]
  37. Szymańska, J. Dental bioaerosol as an occupational hazard in a dentist’s workplace. Ann. Agric. Environ. Med. 2007, 14, 203–207. [Google Scholar]
  38. Liu, M.H.; Chen, C.T.; Chuang, L.C.; Lin, W.M.; Wan, G.H. Removal efficiency of central vacuum system and protective masks to suspended particles from dental treatment. PLoS ONE 2019, 14, e0225644. [Google Scholar] [CrossRef]
  39. Sotiriou, M.; Ferguson, S.F.; Davey, M.; Wolfson, J.M.; Demokritou, P.; Lawrence, J.; Sax, S.N.; Koutrakis, P. Measurement of particle concentrations in a dental office. Environ. Monit. Assess. 2008, 137, 351–361. [Google Scholar] [CrossRef] [PubMed]
  40. Graetz, C.; Plaumann, A.; Tillner, A.; Salzer, S.; Bielfeldt, J.; Dorfer, C. Efficacy versus health risks: An in vitro evaluation of power-driven scalers. J. Indian Soc. Periodontol. 2015, 19, 18. [Google Scholar] [CrossRef] [PubMed]
  41. Harrel, S.K.; Barnes, J.B.; Rivera-Hidalgo, F. Aerosol and Splatter Contamination from the Operative Site during Ultrasonic Scaling. J. Am. Dent. Assoc. 1998, 129, 1241–1249. [Google Scholar] [CrossRef]
  42. Guderian, D.B.; Loth, A.G.; Weiß, R.; Diensthuber, M.; Stöver, T.; Leinung, M. In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling. Eur. Arch. Oto-Rhino-Laryngol. 2020, 1, 3. [Google Scholar]
  43. Siddique, I.; Mahmood, H.; Mohammed-Ali, R. Paracetamol overdose secondary to dental pain: a case series. Br. Dent. J. 2015, 219, e6. [Google Scholar] [CrossRef]
Figure 1. Risk of exposure to SARS-CoV-2 based on the Alberta Federation of Labour (created in BioRender.com).
Figure 1. Risk of exposure to SARS-CoV-2 based on the Alberta Federation of Labour (created in BioRender.com).
Materials 13 05109 g001
Figure 2. Measurement sites and positions of the sensor.
Figure 2. Measurement sites and positions of the sensor.
Materials 13 05109 g002
Figure 3. Particle sensor PC200 (Trotec GmbH, Schwerin, Germany) used in the experiment.
Figure 3. Particle sensor PC200 (Trotec GmbH, Schwerin, Germany) used in the experiment.
Materials 13 05109 g003
Figure 4. The suction systems used in the study. (A) Saliva ejector. (B) High volume evacuator. (C) Saliva ejector with an extraoral vacuum. (D) High volume evacuator with an extraoral vacuum. (E) Zirc® evacuator. (F) Customized high volume evacuator (white). (G) Customized high volume evacuator (black).
Figure 4. The suction systems used in the study. (A) Saliva ejector. (B) High volume evacuator. (C) Saliva ejector with an extraoral vacuum. (D) High volume evacuator with an extraoral vacuum. (E) Zirc® evacuator. (F) Customized high volume evacuator (white). (G) Customized high volume evacuator (black).
Materials 13 05109 g004
Figure 5. The amount of the dental spray during caries removal with low-speed handpiece with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Figure 5. The amount of the dental spray during caries removal with low-speed handpiece with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Materials 13 05109 g005
Figure 6. The amount of the dental spray during caries removal with Er:YAG laser with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Figure 6. The amount of the dental spray during caries removal with Er:YAG laser with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Materials 13 05109 g006
Table 1. The amount of aerosol (×103) measured at the three sites (mean ± SD) during caries removal using the high-speed handpiece with; A. Saliva ejector. B. High volume evacuator. C. Saliva ejector with an extraoral vacuum. D. High volume evacuator with an extraoral vacuum. E. Zirc® evacuator. F. Customized high volume evacuator (white). G. Customized high volume evacuator (black).
Table 1. The amount of aerosol (×103) measured at the three sites (mean ± SD) during caries removal using the high-speed handpiece with; A. Saliva ejector. B. High volume evacuator. C. Saliva ejector with an extraoral vacuum. D. High volume evacuator with an extraoral vacuum. E. Zirc® evacuator. F. Customized high volume evacuator (white). G. Customized high volume evacuator (black).
ProcedureToolsExhaustionPlace of MeasurementANOVA
p
Manikin (A)Operator (B)Assistant (C)
CariesHigh-speed handpieceSaliva ejector260.2 ± 20.6121.2 ± 20.8121.5 ± 9.5A vs. BC p < 0.001
Saliva ejector
+ extraoral vacuum
120.3 ± 18.343.9 ± 2.635.1 ± 1.6A vs. BC p < 0.001
High volume evacuator60.5 ± 3.040.7 ± 3.331.5 ± 2.4A vs. BC p < 0.001
B vs. C p < 0.001
High volume evacuator
+ extraoral vacuum
40.7 ± 0.943.9 ± 1.944.5 ± 1.8A vs. BC p < 0.01
Zirc evacuator32.1 ± 2.031.0 ± 1.431.0 ± 1.00.353
New high volume evacuator—black31.6 ± 1.131.5 ± 1.131.5 ± 0.80.979
New high volume evacuator—white31.5 ± 0.934.0 ± 1.231.2 ± 1.0B vs. AC p < 0.001
Table 2. The amount of the dental spray during tooth’s polishing measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Table 2. The amount of the dental spray during tooth’s polishing measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Place of MeasurementTooth Polishing Procedure with the Low-Speed Handpiece
1000 rpm10000 rpm
Saliva EjectorHigh Volume Evacuatorp-ValueSaliva EjectorHigh Volume Evacuatorp-Value
Manikin345.7 ± 65.8201.0 ± 13.9<0.001330.1 ± 40.379.7 ± 3.1<0.001
Operator37.9 ± 2.334.6 ± 3.10.06335.3 ± 6.934.5 ± 1.90.814
Assistant31.6 ± 1.031.8 ± 1.50.80332.7 ± 2.830.9 ± 1.30.192
<0.001<0.001 <0.001<0.001
Table 3. The amount of the dental spray during ultrasonic scaling with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Table 3. The amount of the dental spray during ultrasonic scaling with a high volume evacuator or saliva ejector, measured in 3 areas and the analysis of variance and post-hoc test (multiple comparisons using the Tukey test).
Place of MeasurementExhaustionTest Result
Saliva EjectorHigh Volume Evacuator
Manikin34.2 ± 2.829.7 ± 1.40.005
Operator32.5 ± 2.328.4 ± 1.20.003
Assistant31.0 ± 1.629.6 ± 0.60.079
ANOVA p0.0720.139
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Matys, J.; Grzech-Leśniak, K. Dental Aerosol as a Hazard Risk for Dental Workers. Materials 2020, 13, 5109. https://0-doi-org.brum.beds.ac.uk/10.3390/ma13225109

AMA Style

Matys J, Grzech-Leśniak K. Dental Aerosol as a Hazard Risk for Dental Workers. Materials. 2020; 13(22):5109. https://0-doi-org.brum.beds.ac.uk/10.3390/ma13225109

Chicago/Turabian Style

Matys, Jacek, and Kinga Grzech-Leśniak. 2020. "Dental Aerosol as a Hazard Risk for Dental Workers" Materials 13, no. 22: 5109. https://0-doi-org.brum.beds.ac.uk/10.3390/ma13225109

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop