Next Article in Journal / Special Issue
A New Approach to Visual-Based Sensory System for Navigation into Orange Groves
Previous Article in Journal
Bromocresol Green/Mesoporous Silica Adsorbent for Ammonia Gas Sensing via an Optical Sensing Instrument
Previous Article in Special Issue
Three-Dimensional Modeling of Tea-Shoots Using Images and Models
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Determination of Moisture Content in Oil Palm Fruits Using a Five-Port Reflectometer

1
Department of Electrical and Electronic Engineering, Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, 53300 Setapak, Kuala Lumpur, Malaysia
2
Department of Physics, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
3
Radio Communication Engineering Department (RaCED), Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
4
School of Mechatronic Engineering, University Malaysia Perlis, Ulu Pauh Campus, 02600 Arau, Perlis, Malaysia
*
Author to whom correspondence should be addressed.
Submission received: 8 March 2011 / Revised: 5 April 2011 / Accepted: 5 April 2011 / Published: 6 April 2011
(This article belongs to the Special Issue Sensors in Agriculture and Forestry)

Abstract

: This paper presents the development of a PC-based microwave five-port reflectometer for the determination of moisture content in oil palm fruits. The reflectometer was designed to measure both the magnitude and phase of the reflection coefficient of any passive microwave device. The stand-alone reflectometer consists of a PC, a microwave source, diode detectors and an analog to digital converter. All the measurement and data acquisition were done using Agilent VEE graphical programming software. The relectometer can be used with any reflection based microwave sensor. In this work, the application of the reflectometer as a useful instrument to determine the moisture content in oil palm fruits using monopole and coaxial sensors was demonstrated. Calibration equations between reflection coefficients and moisture content have been established for both sensors. The equation based on phase measurement of monopole sensor was found to be accurate within 5% in predicting moisture content in the fruits when compared to the conventional oven drying method.

1. Introduction

The principle of the six-port reflectometer for measuring reflection coefficients was introduced by Engen [1] in 1977. Since then, many papers have been published to simplify or extend the application of the instrument [26]. An interesting variant of the six-port unit is provided by the five-port reflectometer where the reflection coefficient of the device under testing can be determined by using only three power detectors [5,6].

Previously, we proposed the use of an open ended coaxial sensor to determine moisture content in oil palm fruits [7] by measuring the reflection coefficient with a Vector Network Analyzer (VNA). In this paper, we present an extension of the technique by measuring the reflection coefficient of the fruits using both open ended coaxial and monopole sensors with a five port reflectometer without requiring the use of VNA.

2. Five Port Reflectometer

2.1. Measurement Setup

The measurement setup, shown in Figure 1, consists of a PC, five-port circuit, a 16 bits Analog/Digital converter PICO ADC16 and a continuous wave signal source (NovaSource M2 NS2-1700104) with a constant 10 dBm output power at 2 GHz. The signals reflected from the sensor are measured using diode detectors (D1, D2, D3) at each output port P1, P2 and P3. The detectors were MIDISCO MDC1087-S Zero Bias Schottky diodes having ±0.5 dB flatness, max VSWR 1.2:1 with an SMA input and a BNC output. The sensors used in this work were the open ended coaxial and monopole sensor [7,8] constructed from an RG 402 semi-rigid cable.

2.2. The Five-Port Circuit Configuration

The five-port circuit shown in Figure 2 was designed at 2 GHz using Microwave Office software version 4.3. The permittivity and thickness of the substrate were ɛr = 2.2 and 1.5748 mm, respectively.

The widths of each arm and ring of the five-port were w1 = 1.008 mm and w2 = 1.272 mm. The radius of the ring was r = 16.968 mm. The components SLIN, SSUB, STEE and SCURVE in Figure 1(b) represent the microstrip line, substrate, T junction and bend, respectively.

2.3. Calibration Procedure

The relationship between the complex reflection coefficient Γ of the unknown load and the power ratios wi can be written in the form [5,6]:

| Γ q i | 2 = | w i | 2
where:
Γ = x + j y
q i = u i + jv i
| w i | 2 = P i / k i
with i = 1, 2 and 3. Pi are the powers measured by the three detectors, ki are the unknown constants to be determined from the calibration procedure and qi are the values of the calibration standards. The four calibration standards used in this work to determine the unknown constant ki, xi, and yi were a precision 50 Ω load, standard open standard, offset 120° and offset 240° open calibration standards. Assuming perfect matched load and open standards, we obtained from Equations (14):
P i k i = u i 2 2 u i x i + x i 2 + v i 2 2 v i y i + y i 2

At port 1 (I = 1):

P 1 k 1 = u 1 2 2 u 1 x 1 + x 1 2 + v 1 2 2 v 1 y 1 + y 1 2

After some algebraic manipulation of Equation (6), the unknown values k1, x1, and y1 for port 1 can be determined from the linear equations system of Equation (7) by measuring the the four calibration standards:

( P 1 open ( 0 ) P 1 m 2 ( u 1 open ( 0 ) u 1 m ) 2 ( v 1 open ( 0 ) v 1 m ) P 1 open ( 120 ) P 1 m 2 ( u 1 open ( 120 ) u 1 m ) 2 ( v 1 open ( 120 ) v 1 m ) P 1 open ( 240 ) P 1 m 2 ( u 1 open ( 240 ) u 1 m ) 2 ( v 1 open ( 240 ) v 1 m ) ) ( 1 k 1 x 1 y 1 ) = ( u 1 open ( 0 ) 2 + v 1 open ( 0 ) 2 u 1 m 2 v 1 m 2 u 1 open ( 120 ) 2 + v 1 open ( 120 ) 2 u 1 m 2 v 1 m 2 u 1 open ( 240 ) 2 + v 1 open ( 240 ) 2 u 1 m 2 v 1 m 2 )

The same procedure can similarly be used to determine other ki, xi, and yi values for ports 2 and 3.

2.4. Determination of the Reflection Coefficient of Device under Test

From Equation (5), the power ratios at port 1, 2 and 3 can be written in the form:

P 1 k 1 = u 1 2 2 u 1 x 1 + x 1 2 + v 1 2 2 v 1 y 1 + y 1 2
P 2 k 2 = u 2 2 2 u 2 x 2 + x 2 2 + v 2 2 2 v 2 y 2 + y 2 2
P 3 k 3 = u 3 2 2 u 3 x 3 + x 3 2 + v 3 2 2 v 3 y 3 + y 3 2

For the device under test, u1 = u2 = u3 = u and v1 = v2 = v3 = v can be obtained from the following matrix:

( 2 x 1 + 2 x 2 2 y 1 + 2 y 2 2 x 2 + 2 x 3 2 y 2 + 2 y 3 ) ( u v ) = ( P 1 k 1 P 2 k 2 x 1 2 + x 2 2 y 1 2 + y 2 2 P 2 k 2 P 3 k 3 x 2 2 + x 3 2 y 2 2 + y 3 2 )

A computer program has been developed to control, acquire, and save data using the Agilent VEE version 7.0 graphical programming software. The program was also used to implement all the calibrations and calculations of the reflection coefficients. As an example, the ADC 16 data acquisition module is illustrated in Figure 3(a). In the final form, all the VEE objects are hidden and only the panel view of the Five-Port Reflectometer in run-time mode as shown in Figure 3(b) is accessible to the end user.

3. Results and Discussion

3.1. Reflectometer Performance

The performance of the five-port reflectometer was tested by comparing reflection coefficient S11 values of eight different offset shorts using both the reflectometer and a commercial VNA. The results are listed in Table 1.

The mean error in magnitude between the reflectometer and VNA measurements was 0.0202, whilst the phase mean error was 1.91°. The accuracy of the reflectometer was further tested by comparing the reflection coefficient S11 measurement results between the reflectometer and the VNA for several well known materials using both the monopole and open ended coaxial sensors. Again good agreement between the reflectometer and VNA results were obtained for all the materials listed in Tables 2 and 3 for the monopole and open ended coaxial sensors, respectively. The maximum errors between the VNA and reflectometer when using the open ended coaxial sensor were 0.0318 and 3.89° (or 3.18% and 1.08%) for magnitude and phase, respectively. The corresponding errors were 0.0304 and 3.14° (or 3.04% and 0.87%) for the monopole sensor.

3.2. Determination of Moisture Content in Oil Palm Fruits

More than 100 fruits in various stages of fruit ripeness were measured using both the coaxial and monopole sensors in conjunction with the five-port reflectometer. Abnormal, not fully developed, dry, and rotten fruits were not considered. The surface of the fruit was wiped dry to free excess surface moisture. All the reflection coefficient S11 measurements of the fruit samples using the five-port reflectometer were done at 26 °C. The samples were then dried in a forced-air oven for four days at 105 °C for moisture content determination on a wet basis [7].

The variations in the magnitude and phase of S11 with moisture content in oil palm fruits are shown in Figures 4 and 5 for the open ended coaxial and monopole sensors, respectively. It can be clearly seen from Figure 4 that both magnitude and phase of the reflection coefficient generally decrease with increasing moisture content in the range between 21% and 75% for the open ended coaxial probe.

However, for the monopole sensor shown in Figure 5, only the phase showed a tendency to decrease with increasing moisture content, whilst the magnitude values were randomly scattered with variation in moisture content. The equation and the determination coefficient R2 shown in each graph were obtained by applying regression analysis. The determination coefficients for both magnitude and phase methods of the open ended coaxial sensor were almost similar. As expected, the highest correlation was obtained from phase measurements using monopole sensor. The phase of S11 is highly sensitive not only to the length of the extended the inner conductor of the monopole sensor but also sensitive to small variation in the complex permittivity of the samples due to different percentages of moisture content. The weak correlation for the magnitude measurement using monopole sensor was due to multiple wave reflection between the extended inner conductor and fruit.

A computer program was developed using the Agilent VEE software to predict moisture content in oil palm fruits by applying inverse relationships to the equations in Figures 4 and 5. A panel view of the program is illustrated in Figure 6.

The results for a different batch of 100 samples of oil palm fruits using open ended coaxial and monopole sensors are compared with the actual values of moisture content obtained using standard oven drying method in Figures 7 and 8, respectively. The phase measurement of the monopole is the most accurate technique to predict the moisture content in oil palm fruits. In contrast, the magnitude of monopole is saturated and has a complex relationship with moisture content. The strong saturation effect in Figure 8(a) was due to fringing fields created by the interaction between the monopole back lobe radiation and the sample. A ground-plane flange is required to minimize the influence of this external noise and can also be used to increase the directivity of the monopole sensor. However, because of its size, a ground-plane flange monopole sensor is not suitable for small samples such as the oil palm fruits. The mean absolute errors were 6.78% and 5.95% when using the magnitude and phase equations of the open ended coaxial sensor, respectively. The lowest absolute mean error was 3.73% when using phase method with the monopole sensor. However, as expected from Figure 5(a), the monopole sensor also recorded the highest absolute mean error (11.32%) when using the magnitude method. This was due to multiple reflection along the interface between the extended inner conductor and fruit.

4. Conclusions

The five-port reflectometer represents a simple, cheap and efficient microwave network analyzer solution to determine reflection coefficients which in turn can be used directly to determine the moisture content in fruits. The reflectometer is especially useful for in-situ determination of the quality of fruits in the field. The detailed calibration procedure has been described. The five port reflectometer circuit was designed and tested against several known standards. The measured reflection coefficient results were in good agreement with the results obtained using a commercial network analyzer. A computer program has also been developed to perform the calibration and calculate the reflection coefficients, which in turn were used to determine moisture content in the oil palm fruits. A prototype of a general five-port reflectometer has been developed and tested for the determination of moisture content in oil palm fruits by using monopole and coaxial sensors. The predicted moisture content based on magnitude and phase measurements of the two sensors were compared with actual moisture content obtained from a standard oven drying method. The phase method of the monopole sensor showed the highest accuracy, with a mean absolute error 3.73%.

References

  1. Engen, GF. The Six-Port Reflectometer: An Alternative Network Analyzer. IEEE Trans. Microwave Theory Tech 1977, 25, 1075–1080. [Google Scholar]
  2. Ball, JAR; Horsfield, B; Holdem, JR; Keam, RB; Holmes, WS; Green, A. Cheese Curd Permittivity and Moisture Measurement Using a 6-Port Reflectometer. Proceedings of Asia Pacific Microwave Conference, Hong Kong, 2–5 December 1997.
  3. Urbanec, T; Svacina, J. Software Support for Six-Port Measurement System. Meas. Sci. Rev 2004, 4, 22–26. [Google Scholar]
  4. Ganouchi, FM; Bosisio, RG. The Six Port Reflectometer and its Complete Calibration by Four Standard Terminations. IEEE Proc 1988, 135, 285–289. [Google Scholar]
  5. Hansson, ERB; Riblet, GP. An Ideal Six-Port Network Consisting of a Matched Reciprocal Lossless Five-Port and a Perfect Directional Coupler. IEEE Trans. Micro. Theory Techn 1983, 31, 284–288. [Google Scholar]
  6. Chahine, SA; Huyart, B; Osman, Z. Performance Comparison Between Six Port and Five-Port Reflectometer. Proceedings of NRSC 2003: The Twentieth National Radio Science Conference, Cairo, Egypt, 18–20 March 2003; pp. 1–6.
  7. Abbas, Z; Yeow, YK; Shaari, AH; Khalid, K; Hassan, J; Saion, E. Complex Permittivity and Moisture Measurements of Oil Palm Fruits Using an Open-Ended Coaxial Sensor. IEEE Sens. J 2005, 5, 1281–1287. [Google Scholar]
  8. Durney, CH; Iskander, MF. Antennas for Medical Application. In Antenna Handbook; Van Nostrand Reinhold: New York, NY, USA, 1993; Chapter 24. [Google Scholar]
Figure 1. Five-port reflectometer. (a) five-port reflectometer measurement setup; (b) photo of five-port reflectometer; (c) five-port reflectometer main components.
Figure 1. Five-port reflectometer. (a) five-port reflectometer measurement setup; (b) photo of five-port reflectometer; (c) five-port reflectometer main components.
Sensors 11 04073f1a 1024Sensors 11 04073f1b 1024
Figure 2. Five-port circuit. (a) Fabricated circuit; (b) Microwave Office Workspace.
Figure 2. Five-port circuit. (a) Fabricated circuit; (b) Microwave Office Workspace.
Sensors 11 04073f2a 1024Sensors 11 04073f2b 1024
Figure 3. Five-port reflectometer software. (a) Data acquisition module; (b) Panel view.
Figure 3. Five-port reflectometer software. (a) Data acquisition module; (b) Panel view.
Sensors 11 04073f3 1024
Figure 4. Variation in magnitude and phase of S11 with moisture content using open ended coaxial sensor. (a) Magnitude; (b) Phase.
Figure 4. Variation in magnitude and phase of S11 with moisture content using open ended coaxial sensor. (a) Magnitude; (b) Phase.
Sensors 11 04073f4 1024
Figure 5. Variation in magnitude and phase of S11 with moisture content using monopole sensor. (a) Magnitude; (b) Phase.
Figure 5. Variation in magnitude and phase of S11 with moisture content using monopole sensor. (a) Magnitude; (b) Phase.
Sensors 11 04073f5 1024
Figure 6. Panel View of VEE Program to determine moisture content in oil palm fruits.
Figure 6. Panel View of VEE Program to determine moisture content in oil palm fruits.
Sensors 11 04073f6 1024
Figure 7. Comparison between predicted and actual moisture content. (a) Magnitude; (b) Phase methods using coaxial sensor.
Figure 7. Comparison between predicted and actual moisture content. (a) Magnitude; (b) Phase methods using coaxial sensor.
Sensors 11 04073f7 1024
Figure 8. Comparison between predicted and actual moisture content. (a) Magnitude; (b) Phase methods using monopole sensor.
Figure 8. Comparison between predicted and actual moisture content. (a) Magnitude; (b) Phase methods using monopole sensor.
Sensors 11 04073f8a 1024Sensors 11 04073f8b 1024
Table 1. Magnitude and phase of reflection coefficient measured using reflectometer and commercial VNA.
Table 1. Magnitude and phase of reflection coefficient measured using reflectometer and commercial VNA.
StandardVNAReflectometerDeviation
MagnitudePhaseMagnitudePhaseMagnitudePhase
Std 10.9860−30.300.9931−31.220.00710.92
Std 20.9990−69.611.0070−72.130.00802.52
Std 30.9860−138.931.0210137.400.03501.53
Std 41.0042−105.501.0200107.200.01581.70
Std 51.0030180.001.0410177.100.03802.90
Std 60.9950129.500.9850131.400.01001.90
Std 70.991052.600.975050.200.06602.40
Std 80.02009.670.00278.250.01731.42
Mean0.02021.91
Table 2. S11 of several known materials using monopole sensor.
Table 2. S11 of several known materials using monopole sensor.
VNAReflectometer
MagnitudePhaseMagnitudePhase
Air0.9845−30.000.9637−33.72
Water0.9050−173.530.8980−169.77
Ethanol0.4712−80.530.5078−81.96
Propanol0.7257−49.560.6939−52.15
Methanol0.6773−154.560.7040−150.67
Table 3. S11 of several known sample using open ended coaxial.
Table 3. S11 of several known sample using open ended coaxial.
VNAReflectometer
MagnitudePhaseMagnitudePhase
Air0.9829138.530.9582141.29
Water0.884157.550.914358.50
Ethanol0.8091127.240.8093130.04
Propanol0.740390.510.770190.40
Methanol0.8939133.080.8890136.22

Share and Cite

MDPI and ACS Style

Yee, L.K.; Abbas, Z.; Jusoh, M.A.; Yeow, Y.K.; Meng, C.E. Determination of Moisture Content in Oil Palm Fruits Using a Five-Port Reflectometer. Sensors 2011, 11, 4073-4085. https://0-doi-org.brum.beds.ac.uk/10.3390/s110404073

AMA Style

Yee LK, Abbas Z, Jusoh MA, Yeow YK, Meng CE. Determination of Moisture Content in Oil Palm Fruits Using a Five-Port Reflectometer. Sensors. 2011; 11(4):4073-4085. https://0-doi-org.brum.beds.ac.uk/10.3390/s110404073

Chicago/Turabian Style

Yee, Lee Kim, Zulkifly Abbas, Mohamad Ashry Jusoh, You Kok Yeow, and Cheng Ee Meng. 2011. "Determination of Moisture Content in Oil Palm Fruits Using a Five-Port Reflectometer" Sensors 11, no. 4: 4073-4085. https://0-doi-org.brum.beds.ac.uk/10.3390/s110404073

Article Metrics

Back to TopTop