Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Effect of activation modes on the compressive strength, diametral tensile strength and microhardness of dual-cured self-adhesive resin cements
Ah-Rang KIMYong-Chan JEONChang-Mo JEONGMi-Jung YUNJae Won CHOIYong Hoon KWONJung-Bo HUH
Author information
JOURNAL FREE ACCESS

2016 Volume 35 Issue 2 Pages 298-308

Details
Abstract

The purpose of this study was to compare the compressive strength, diametral tensile strength and microhardnss of several selfadhesive resin cements (Rely-X U200, Clearfill SA Luting, G-CEM LinkAce, Maxcem Elite, PermaCem 2.0, and Zirconite) using different activation modes (self-cured, light-cured) and testing time (immediately, 24 h, thermocycling). Specimens were prepared for the compressive strength (Ø 4×6 mm) and diametral tensile strength and microhardness (Ø 6×3 mm) according to ISO standards. The strength after 24 h was higher than immediately after. In addition, G-CEM showed the highest values. In terms of the activation modes, Rely-X U200, PermaCem 2.0 had higher values in the light-curing than the self-curing. In conclusion, all cements demonstrated clinically available strength values and revealed differences in strength according to their composition, testing time and activation mode. Furthermore, correlation was found between the microhardness (degree of conversion) and mechanical strengths of the cements tested.

Content from these authors
© 2016 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top