Reliability & linearity of an electronic body protector employed in taekwondo games: a preliminary study

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/30255
Información del item - Informació de l'item - Item information
Título: Reliability & linearity of an electronic body protector employed in taekwondo games: a preliminary study
Autor/es: Tasika, Niki
Palabras clave: EBP | TKD | Scoring | WTF
Área/s de conocimiento: Educación Física y Deportiva
Fecha de publicación: 2013
Editor: Universidad de Alicante. Área de Educación Física y Deporte
Cita bibliográfica: TASIKA, Niki. “Reliability & linearity of an electronic body protector employed in taekwondo games: a preliminary study”. Journal of Human Sport and Exercise [en línea]. Vol. 8, No. 3Proc (2013). ISSN 1988-5202, pp. S622-S632. http://www.jhse.ua.es/jhse/article/view/527 [consulta: 4 sept. 2013]
Resumen: An official electronic body protector (EBP) requires both, the necessary degree of accuracy and consistency in securing the same result under similar conditions. The purpose of this study was to assess the repeatability and linearity of a taekwondo EBP. A commercially available EBP that registers the energy (E) of a hit in Joules was placed unfolded on a hard non-deformable surface. Ten potential "hit" areas were marked on the EBP's surface. To simulate kicking conditions a 4 kg iron shot attached to a switch operated electromagnet was systematically released against the EBP from three randomly selected heights (1.78m, 1.92m, and 2.00m). The shot was released 5 times repeatedly from each height on each of the 10 areas. The procedure was repeated after a 30min interval. Reliability was assessed by the test-retest method using Chronbach's alpha, Guttman split half and ICC, and the coefficient of variation (%CV). The overall (10 sites pooled together) CV was 4.8%. Τhe CV’s for the three heights of release were 5.47%, 4.77%, and 4.18%, respectively. For the 10 separate analyses (one for each of the 10 EBP sites) CV ranged from 2.5% to 11.6%. For the 10 separate analyses (one for each of the 10 trials) CV ranged from 6.8% to 11.6%. The overall reliability between the 30 trials (across the three heights of release) was: Chronbach's α = 0.979, single measure ICC = 0.572, average measure ICC = 0.976 (p<0.001). Testing revealed that the inter-trial and inter-site reliability of the EBP is poor. Further research is required in testing the reliability of a variety of body protectors used in official competitions today so as to assure fairness among contestants.
URI: http://hdl.handle.net/10045/30255
ISSN: 1988-5202
DOI: 10.4100/jhse.2013.8.Proc3.08
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: Licencia Creative Commons Reconocimiento-NoComercial-SinObraDerivada 3.0
Revisión científica: si
Versión del editor: http://dx.doi.org/10.4100/jhse.2013.8.Proc3.08
Aparece en las colecciones:Journal of Human Sport and Exercise - 2013 - Performance Analysis WORKSHOP, Alicante, 2-5 April 2013

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnailjhse_Vol_8_N_proc3_622-632.pdf1,41 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons