Next Article in Journal
A New BAT and PageRank Algorithm for Propagation Probability in Social Networks
Next Article in Special Issue
CORSIA—A Feasible Second Best Solution?
Previous Article in Journal
Forecasting the Future Excellence: 30 Years of Evaluating Service Organizations in Slovakia
Previous Article in Special Issue
Climate Impact Reduction Potentials of Synthetic Kerosene and Green Hydrogen Powered Mid-Range Aircraft Concepts
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Parametric Approach for Conceptual Integration and Performance Studies of Liquid Hydrogen Short–Medium Range Aircraft

1
Department of Civil and Industrial Engineering, University of Pisa, Via G. Caruso 8, 56122 Pisa, Italy
2
SkyBox Engineering, Via G. Caruso 8, 56122 Pisa, Italy
*
Author to whom correspondence should be addressed.
Submission received: 22 June 2022 / Revised: 28 June 2022 / Accepted: 2 July 2022 / Published: 6 July 2022
(This article belongs to the Special Issue Climate Impact of Aviation)

Abstract

:
The present paper deals with the investigation, at conceptual level, of the performance of short–medium-range aircraft with hydrogen propulsion. The attention is focused on the relationship between figures of merit related to transport capability, such as passenger capacity and flight range, and the parameters which drive the design of liquid hydrogen tanks and their integration with a given aircraft geometry. The reference aircraft chosen for such purpose is a box-wing short–medium-range airplane, the object of study within a previous European research project called PARSIFAL, capable of cutting the fuel consumption per passenger-kilometre up to 22%. By adopting a retrofitting approach, non-integral pressure vessels are sized to fit into the fuselage of the reference aircraft, under the assumption that the main aerodynamic, flight mechanic, and structural characteristics are not affected. A parametric model is introduced to generate a wide variety of fuselage-tank cross-section layouts, from a single tank with the maximum diameter compatible with a catwalk corridor to multiple tanks located in the cargo deck, and an assessment workflow is implemented to perform the structural sizing of the tanks and analyse their thermodynamic behaviour during the mission. This latter is simulated with a time-marching approach that couples the fuel request from engines with the thermodynamics of the hydrogen in the tanks, which is constantly subject to evaporation and, depending on the internal pressure, vented-out in gas form. Each model is presented in detail in the paper and results are provided through sensitivity analyses to both the technologic parameters of the tanks and the geometric parameters influencing their integration. The guidelines resulting from the analyses indicate that light materials, such as the aluminium alloy AA2219 for tanks’ structures and polystyrene foam for the insulation, should be selected. Preferred values are also indicted for the aspect ratios of the vessel components, i.e., central tube and endcaps, as well as suggestions for the integration layout to be adopted depending on the desired trade-off between passenger capacity, as for the case of multiple tanks in the cargo deck, and achievable flight ranges, as for the single tank in the section.

1. Introduction

According to ACARE ([1]) and European Commission ([2]), the main milestones of the path towards sustainable aviation are a significant reduction in CO 2 (−75%) and NO X (−90%) emissions by 2035, and the total decarbonisation within 2050. To achieve these goals, the second one in particular, the synergy between two or more of the following enabling technologies would be needed: ultra-efficient airframes, full or hybrid–electric propulsion, and sustainable drop-in or non-drop-in fuel, as, for example, hydrogen. The low energy density of batteries makes electric propulsion suitable for aircraft up to the regional category, whereas drop-in and non-drop-in fuel may be adopted in Short-to-Medium Range (SMR) aircraft, in particular those meeting the ICAO Aerodrome Reference Code element 2 “C” (e.g., Airbus 320, Boeing 737, etc.). Adopting hydrogen as fuel is among the promising ways to achieve the decarbonisation goal ([3,4,5]), since it has very high energy density and its combustion does not produce CO 2 . On the other hand, embarking gaseous hydrogen is not feasible, since it would require tanks about 3000 times larger than current ones; therefore, hydrogen needs to be stored in liquid conditions by means of a proper combination of cryogenic temperature and high pressure.
From the decarbonisation point of view, hydrogen is to be considered more as an energy storage than as fuel since there are no direct natural sources on Earth. The hydrogen can be obtained by processing various sources, such as hydrocarbons, biomass, and water. These processes have their own CO 2 emission levels, which should be considered in the total emissions balance. However, this estimation is dependent on the energetic policy and infrastructure of the nation in which the aircraft is operated; moreover, although hydrogen combustion does not release CO 2 , it generates water and NO x , whose effects on climate change are under study. Another important point about the application of this technology is the impact on airport infrastructure, as well as the choice of generating hydrogen on-site or not. For the reasons above, an estimation of the direct and non-direct emission is omitted in this paper, which should be regarded as a feasibility study of the application of the hydrogen propulsion technology to aircraft.
The storage system for liquid hydrogen, hereafter indicated as LH 2 , is thus made of large tanks with appropriate thermal insulation, whose integration with the aircraft raises questions about the effective achievable benefits under given operational constraints, as, for example, the minimum number of passengers and flight range. This aspect opens to new research opportunities which touches the aforementioned ultra-efficient airframes, i.e., aircraft architectures, different than the conventional tube-and-wing one, that can boost the adoption of new technologies leveraging on their higher aerodynamic efficiency. In fact, since the conventional tube-and-wing architectures are mature and modifying the geometries of fuselage or wings would move the design far from the current optimal solutions, considering different architectures can facilitate the introduction of LH 2 propulsion technologies from the very early stages of the design.
A previous example of addressing a similar research question is given by the European project PARSIFAL ([6,7,8,9]), in which a box-wing aircraft designed for the SMR category (Figure 1a) has been assessed under the operational and environmental standpoints.
Assuming adoption of conventional turbofan engines, results have shown a potential of reducing fuel burnt by 22% per seat-kilometres, with an impact on both CO 2 and non- CO 2 emissions, hence on short-term and long-term global warming and temperature change potential ([10]). The box-wing aircraft investigated in PARSIFAL is the result of a design strategy that exploits the superior aerodynamic performance of the box-wing, known since the first studies carried out by L. Prandtl in the early 1920s ([11]). In PARSIFAL, the higher span efficiency of the box-wing is exploited to significantly increase the number of passengers while keeping the wingspan below 36 m; thus, placing the aircraft in the same segment of the aircraft compliant with the ICAO Aerodrome Reference Code element 2 “C”. This competitive advantage is obtained by designing a larger fuselage, with a double aisle and 8-seats abreast cabin, which increases the maximum number of passengers from less than 190 to more than 300 (see Table 1 for details).
Can this increase in the internal volume facilitate the integration of LH 2 tanks, without significant penalisation of transport capabilities? The present paper aims to assess the potential given by the synergy between the LH 2 propulsion and the box-wing architecture by means of a retrofitting approach. This means that the box-wing aircraft described in Table 1, and more in detail in Section 2.6.1, is modified at a conceptual level to integrate cylindrical LH 2 tanks in the fuselage and then the whole system is analysed to define the overall aircraft performance. The retrofitting approach does not bring optimal solutions since it does not allow to modify the external shape of the aircraft, but it allows to obtain results relying on well-studied aerodynamics, flight mechanics, and structural characteristics ([8,12]), which—at least for this conceptual level of investigation—can be considered as not affected by the tank integration. Among the hypothesis concerning flight mechanics, it is assumed that the Static Stability Margin varies within the interval estimated for the reference aircraft.
The paper is organised as follows: Section 1 introduces the scope of this work and state of the art about studies dealing with the design of aircraft with LH 2 propulsion; Section 2 provides both an overview of the retrofitting approach adopted for the analysis and details about the implemented models, focusing on geometric, structural, and thermodynamic ones; Section 3 presents the results of sensitivity analyses carried out against the design parameters recognised as most relevant; Section 4 summarises the main outcomes and indicates some possible paths to improve the research. Finally, an Appendix provides supplementary information about the discussed topics.

1.1. Scope of the Work

The scope of this work is to identify of the most significant design parameters governing the design of LH 2 tanks and their integration within the aircraft, considering only the volumes available inside the fuselage, in order to avoid any variation in the shape of the reference aircraft. In order to implement standard methods for structural design and thermodynamic analysis, non-integral metallic tanks are considered assuming the typical shapes of pressure vessels. Different solutions based on integral tanks and/or composite materials are not considered because of the limitations of the structural model adopted here.
Tanks–fuselage integration is then parametrised through a set of variables which affect tanks geometry, structural behaviour, and thermodynamic performance. Time-marching simulations are then performed considering the thermodynamic conditions of hydrogen, which is stored in cryogenic conditions and thermally insulated with a passive system, such as one or more insulant layers covering the whole internal or external tank surface. This implies that the LH 2 is subject to a continuous heat exchange with the external environment, which causes an evaporation process resulting in an increase in the internal pressure. When this latter reaches a preassigned value, said venting pressure, gaseous hydrogen is vented-out to avoid internal pressure increase. Moreover, venting stops only if the flow of LH 2 towards the engines is strong enough to determine a net reduction in the internal pressure. This introduces an additional mechanism leading to LH 2 depletion, which can be properly evaluated only by coupling the mission simulation with the thermodynamic analyses.

1.2. State of the Art

Studies on the use of hydrogen for the aircraft propulsion started around 1950, inside programs aimed at the introduction of new fuels to extend the range and ceiling of military spy planes, trying to avoid combustion shortcomings of traditional JP fuels at high altitudes. One of these projects is the NACA “Project Bee” ([13]), which developed a notable series of reports around 1956 ([14,15,16,17]). Later, in the 1970s, in response to oil crises, NASA commissioned studies for the replacement of conventional aviation fuel: the candidates were hydrogen and methane. The main U.S. aircraft manufacturers proposed a wide range of aircraft designs, ranging from short-haul to intercontinental jets ([18,19,20]), along with airport integration feasibility studies ([21]) and plans for development programs. In 1988, a USSR project developed the TU-155 testbed, which used hydrogen and other gasses for the turbojet feeding.
In more recent years, the European Union gave a new motivation to the research about hydrogen as an energy vector, setting up dedicated research programs, such as CRYOPLANE ([22]) and CHATT ([23]). The aim of these studies is the decarbonisation of the transport industry, the development of a more sustainable energetic market, and an improvement in the EU energetic independence ([1,2]).
Concerning the aircraft design perspective, reference works are [18,19,20,24,25] and [26]. In such studies, the influence of the hydrogen storage state, engine technology, and tank–aircraft configuration integration are studied. Specific information about engines can be found in [15,17,27,28], with different engine architecture options aiming to enhance performance or to minimise the changes from current technology. Tank design is studied in [14,16,25,29,30,31,32], where the problems of the insulation, structural design, and thermodynamic state simulation are addressed. The level of detail of the aforementioned studies is summarised in Table 2.

2. Overall Analysis Approach and Implemented Methods

2.1. Data and Assumptions on L H 2 Technology

As reported in [18,19,20,22,24,25,26,30,32], LH 2 propulsion technology brings significative changes in aircraft design; they mainly concern the turbofan engines and the LH 2 storage, as shown in the following paragraphs.

2.1.1. LH2 Turbofan Engines

The use of H 2 as fuel in the combustion chamber of a turbomachinery has been studied in [17,19,22,25,27,28]. The combustion of H 2 is possible in a wider range of pressures and fuel/air mixtures than those allowed by JP4 (Figure 4 in [17]). Therefore, it is possible to convert ordinary turbofans to run on H 2 , or design new engines for new operative conditions ([19]). In this work, the engine design has been preserved, following the “retrofit” approach proposed in [27], in order to minimise engine modifications.
Despite the marginal variation in the engine design, there is the need of a heat exchanger (HE), in order to shift the hydrogen state from storage conditions to combustion chamber injection conditions. In [22,27], some HE options have been proposed; however, in order to minimise the changes to the engine and the airframe, in this work, the HE will be considered located after the Low Pressure Turbine. For an engine with this configuration, delivering the same thrust of a JP4 fuelled engine, in [27] the authors indicate that the SFC decreases by 64.71% and Turbine Entry Temperature decreases by 31.5 K, with a significant improvement in engine life. The weight of the engine itself is the same as a conventional one, but the HE adds 1% to the overall engine weight ([27]).

2.1.2. LH2 Storage

The most relevant change introduced by the LH 2 propulsion is the need for a new kind of tank. A hydrogen tank should guarantee thermal insulation and pressurisation in order to preserve the storage state of the hydrogen. Furthermore, in the case of tank cracks or failures, a proper level of pressurisation is needed to prevent oxygen from entering the tank, which can lead to explosive mixtures ([25,33]). The hydrogen storage state is an important point of discussion, since it influences the hydrogen density and the tank structural design; the main options are the three blue areas highlighted in Figure 2, taken from [34].
Most of the studies ([14,16,18,19,20,22,24,25,26,29,31,32,34,35]) concern tanks at storage states close to region 1 (see Figure 2), where the hydrogen is in a saturated liquid form ( LH 2 ), the pressure varies between 0.1 and 0.4 MPa and temperatures are lower than 30 K. In region 3, gaseous hydrogen ( H 2 ) is stored at a higher density (+33%) but the storage pressure is considerably higher (50–100 MPa), which leads to heavier tanks and safety issues, since the pressure rises faster under incoming heat flux [24]. Storage solutions in region 2 exhibit the lowest density, hence larger tanks which are difficult to integrate with the aircraft.
For the reasons above, in this work the hydrogen is considered stored in a state close to the region 1. In such state, both liquid and gaseous phases are present (biphasic saturated state), hence, LH 2 cannot fill the total internal volume of the tank. Liquid and gaseous saturated phases are at equilibrium and show the same temperature and the same pressure; therefore, they constitute a saturated liquid–gas mixture. In saturation state, the gas law is no more valid, and pressure and temperature of the mixture show a bijective relation not dependent on other variables (Figure 3). For the purposes of this work, the physical properties of the two phases were taken from [36] and used in the form of lookup tables for data interpolation.
Since the heat flux directed from the external environment towards the tank causes a pressure raise ([31]), tanks need a venting valve which avoids the internal pressure overcoming the maximum design pressure. The venting of H 2 represents a loss of fuel and leads to a reduction in the aircraft flight range; therefore, an insulation system is required to minimise the heat exchange and thus the pressure increase. For any assigned reference internal pressure, the internal volume cannot be completely filled with LH 2 , because in the case of pressure rise there would not be H 2 to be vented and pressure could not be lowered. Anyway, when considering a partial filling, it must be verified that the stored LH 2 does not expand (Figure 3b) to the maximum capacity of the tank when it reaches the venting pressure. For the reasons above, the authors of [24,25,26] studied pressure levels and filling volumes in order to have a reasonable fuel density, while considering a minimum pressure to avoid contamination. The heat flux across the tank walls depends on three main thermal exchange stages: convection and radiation with the external environment, conduction across the tank insulant and structures, and the heat exchange inside the fluid ([24,25]).
There are different ways to guarantee the insulation of the tank; the simplest is to use a thick layer of insulating material ([14,16]), such as closed cells foams; other methods use open cell foams and a mylar liner ([24,25]) or a double-walled tank, with vacuum between the walls and multi-layer insulation on each side of the vacuum jacket, in order to prevent thermal exchange by radiation ([34]). In this work, simple closed cell insulation foams are considered. The types are a polystyrene foam, a polymethacrylimide foam, and a polyurethane foam, with the characteristics summarised in Table 3. Data regarding polystyrene foam are taken from [16], whereas data about polymethacrylimide and polyurethane foams are from [25]. Thermal conductivity data about foams are taken from [16,25] and reported in Figure 4. It can be noted that, for this kind of material, the thermal conductivity strongly depends on the temperature.
As in [24], in order to keep the design of aircraft-borne LH 2 tanks as general as possible and applicable to different integration solutions, non-integral tanks with inner metallic structural vessel and external foam insulation were taken into account. Since more tanks can be installed in the same fuselage portion, the thermodynamic analysis should take their mutual interaction into account. To reduce the computational time, this problem was simplified assuming that each tank is thermodynamically isolated from the others and that the foam insulation is in contact with the air flowing at the aircraft flight speed. This means that the insulation effect of the calm air inside the fuselage as well as the additional thermal resistance of the fuselage skin are neglected, leading to an overestimation of the heat exchange and providing conservative results on aircraft performance.
Concerning the structural materials, three metal alloys were considered: the stainless steel grade 301 (SS301), the aluminium alloy 2219 (AA2219), and the titanium alloy Ti-5Al-2.5Sn. The mechanical characteristics at cryogenic temperature conditions (20 K) were extrapolated from [37] and are here summarised in Table 4. These materials have been considered in several of the studies cited in the present section, and details are not reported for sake of conciseness.

2.2. Overview of the Analysis Method

The analysis method adopted here aims at defining the relevant parameters for the integration of hydrogen tanks into the fuselage of an SMR aircraft with assigned shape and aerodynamic characteristics, previously determined considering turbofan engines propelled with kerosene. Therefore, the present method is based on the main assumption that, at a conceptual level, a LH 2 transport aircraft sharing the same external shape of a conventional Jet A fuel aircraft, can be studied modifying the characteristic of this latter, once the volume, structural mass, and insulation foam mass needed for tanks is estimated. Moreover, it is assumed that each tank is a non-integral vessel with a circular cross-section, composed of a cylindrical central tube and semi-ellipsoidal endcaps, with a structure made of unstiffened shells covered by a uniform layer of insulation foam (see Figure 7 Section 2.3). For a better understanding, an artistical representation of tank–fuselage integration layouts is given in Figure 5, which shows both solutions aiming at maximising the available internal volume while keeping continuity between fore and aft fuselage through a “catwalk” (Figure 5a,c), and solutions which limit the tanks’ impact on the fuselage design as in Figure 5b. The parametric description of all these geometries is provided in Section 2.3.
The analysis method is represented in Figure 6 and implemented as follows:
  • The available fuselage section is approximated as an elliptic area, hence the tanks’ layout and the external radius of each of them are parameterised as functions of a single variable;
  • It is assumed the insulation foam is the outermost layer of the tank, hence once its thickness is given, the external radius of each tank structure can be calculated;
  • The ASME Boiler and Pressure Vessel Code ([38,39]) are then adopted to the define the structural thickness of each tank, considering the load conditions defined in [26]. The structural sizing takes both the insulation foam mass and the internal volume occupied by LH 2 into account; therefore, at the end of this step the tanks’ groups are fully defined in terms of geometries, masses, and internal volumes;
  • The aircraft empty weight is updated and, for those cases in which tank installation causes limitations of the cabin length available for passengers, the same is completed for payload;
  • Once the aircraft take-off weight is updated and the initial embarked LH 2 is known, a time-marching simulation of the flight mission is performed considering that at each time step all the non-empty tanks contribute equally to feed the engines;
  • The time-marching simulation is coupled at each timestep with thermodynamic analyses that evaluates, for each tank, masses, pressures, temperatures, etc., of both liquid and gaseous hydrogen. These analyses allow to estimate the mass flow of evaporated hydrogen to be expelled in the atmosphere through the venting valve;
  • By summing up the LH 2 flow going to the engines and the vented gaseous hydrogen flow, the hydrogen consumption is simulated through the following flight phases: preparation for flight (holding time between LH 2 fuelling and engine start), taxi-out, take-off run, take-off path, climb, and cruise. The mission ends once one of the following conditions is reached:
    The total amount of LH 2 in all the tanks is lower than the fuel needed for the remaining flight phases (descent, diversion, approach, and landing) and for reserve;
    The internal pressure of all the tanks is lower than an assigned threshold value.
  • If the cruise is successfully completed, the considered tank layout is associated to a set of output data including flight range, maximum number of passengers, aircraft empty weight, burnt and vented LH 2 .
The following paragraphs provide a detailed description of all the above-mentioned steps and their implementation in a MATLAB code with most relevant results.

2.3. Parametric Definition of Tanks Geometry

The geometry of a generic longitudinal section of any of the tanks is defined as in Figure 7, for which it assumed that the thickness of insulation foam ( t i n s ), central walls ( t c ), and endcap walls ( t e ) are uniform.
The other relevant parameters indicated in Figure 7 are:
  • R : external radius of the tank;
  • R s t r : external radius of the structural part, same for both central tube and endcaps;
  • R c i n t : internal radius of the cylindrical tube;
  • R e i n t : internal radius of endcaps measured at the junction with the cylindrical tube;
  • L : length of the cylindrical tube;
  • L e n d : longitudinal dimension of the semi-ellipsoidal endcap, whose ratio versus R s t r , also called endcaps aspect ratio and indicated as f e n d , is given in Equation (1);
    f e n d = L e n d R s t r
  • L t o t : total length of the tank, for which the relation in Equation (2) stands:
    L t o t = L + 2 · R s t r · f e n d + 2 · t i n s
  • d s u p p : distance between supports providing the structural connection between the tank and the fuselage.
The parametric description of tanks’ geometry was focused on the description of the space occupied by the tanks within the fuselage cross-section, and it was conceived to handle a high number of tank layouts using a small number of parameters. The input needed by the parametric model is the dimensions of the available fuselage section and the position of the main tank in the fuselage cross-section. These inputs can be provided in a different manner, depending on the desired layout:
  • Full-section layout: a set of tanks properly sized to occupy the elliptic cross-section of the fuselage, hence reducing the space available for passengers and containers;
  • Part-section layout: a set of tanks properly sized to occupy only the parts of the fuselage cross-section below and/or above an assigned height, hence not reducing the space available for passengers;
In addition, the presence of “catwalks”, i.e., corridors which allow crews and passengers to walk through the portion of fuselage occupied by the LH 2 tanks, and multiple groups of tanks (both with full-section and part-section layout) can be specified.
Since space constraints are given through section borders, all the considered layouts are conceived for fuselage parts that can be approximated as cylindrical, as the central ones, whereas fore and aft fuselage volumes are not considered as available for tank integration in this study.

2.3.1. Full-Section Layout

The design concept behind a full-section layout consists of embarking large quantities of LH 2 by replacing the fuselage volume occupied by passengers and containers with fuel tanks. Such a solution has the potential advantage of allowing long-range flights, with a penalisation in terms of maximum transportable payload.
The full-section layout is defined for an elliptic fuselage internal section, whose width and height are given by the semi-major axis ( w ) and the semi-minor axis ( h ), respectively. These parameters also determine the aspect ratio f , according to Equation (3).
f = h w
Normalising the semi-major axis ( w = 1 ), the following analytical treatment can refer to non-dimensional variables.
The space available for the main tank (or “Tank 0”) is defined as the biggest circle ( 0 ) inscribed in the ellipse, fulfilling the condition of tangency in the point T 0 ( c o s   t 0 , f · s i n   t 0 ) , where t 0 is the arbitrary chosen polar coordinate indicated in Figure 8a. The picture provides the graphical representation of 0 , showing its symmetry to the horizontal axis. The centre of 0 has coordinates C 0 ( x 0 ,   y 0 ) given by Equation (4), whereas the radius r 0 is given by Equation (5).
C 0 :   { x 0 = c o s   t 0 · ( 1 f 2 ) y 0 = 0
r 0 = f f 2 · c o s 2 t 0 + s i n 2 t 0
The space available for side tanks, “Tank 1” and “Tank 2”, is then defined setting the conditions that describe the circles 1 and 2 , respectively, at left and right of 0 as Figure 8b shows. As Equations (6)–(9) show, once 0 is known, 1 and 2 centres and radii can be defined univocally.
C 1 :   { x 1 = m i n ( x 0 r 0 1 2 , f 2 1 ) y 1 = 0
r 1 = m i n ( x 0 r 0 + 1 2 , f 2 )
C 2 :   { x 2 = m a x ( x 0 + r 0 + 1 2 , 1 f 2 ) y 2 = 0
r 2 = m i n ( 1 x 0 r 0 2 , f 2 )
The following two steps consist of defining the space available for two additional couples of tanks (“Tanks 3” and “Tanks 4”) through the construction of the circles 3 (Figure 8c) and 4 (Figure 8d), which are tangent to the ellipse and to 0 as well as to 1 , if in the case of 3 , or 2 , if in the case of 4 .
Considering the 3 circle belonging to the upper semi-plane, its centre C 3 ( x 3 ,   y 3 ) and radius r 3 can be found by solving the system given by Equation (10), in which the first line introduces the condition of tangency of 3 to both 0 and 1 as a constraint for r 3 , the second line constrains the centre C 3 to belong to the line perpendicular to the ellipse in an unknown point defined by the polar coordinate t 3 , and the third line sets the tangency of 3 to the ellipse through an additional constraint for r 3 . Equation (10) was solved numerically using the MATLAB vpasolve function and an analogous system was solved to determine 4 centre and radius.
{ r 3 = ( x 3 x 0 ) 2 + ( y 3 y 0 ) 2 r 0 = ( x 3 x 1 ) 2 + ( y 3 y 1 ) 2 r 1   s i n   t 3 · ( x 3 c o s   t 3 ) f · c o s   t 3 ·   ( y 3 f · s i n   t 3 ) = 0 ( x 3 x 0 ) 2 + ( y 3 y 0 ) 2 r 0 = ( x 3 c o s   t 3 ) 2 + ( x 3 f · s i n   t 3 ) 2
The procedure here described constitutes an algorithm which allows to define the layout of a large number of tanks by varying just one parameter, t 0 , in the range [ 0 ,     π ] . The choice of limiting the maximum number of tanks to 7 was set for practical reasons, both related to the technological limitations in manufacturing and using vessels with small radii, and to the computation time of the coupled mission–thermodynamic simulation, which is almost proportional to the number of tanks.
By implementing this algorithm in a MATLAB code, some geometric performance analyses were carried out varying the t 0 parameter, in order to assess the capability of covering the available area while limiting the external perimeter, since it affects the heat exchange between the LH 2 at cryogenic temperature and the external atmosphere. For this purpose, two geometric performance indicators were defined: e a , the fraction of area covered by all the circles ( A T O T ) defined with respect to the ellipse area as shown in Equation (11), and e p , the normalised area–perimeter ratio defined as in Equation (12), where the denominator is A / p 2 for the circle, i.e., the maximum achievable value for a plane figure.
e a = A T O T π f
e p = A T O T / p T O T 2 1 / ( 4 π )
Figure 9 shows the results of e a and e p calculated for f = 0.75 and various t 0 values, both for the ideal case of no constraints to the minimum external radius R (a) and for the case in which the minimum value was set to 10% of the fuselage half-width (b). Figure 10 provides some examples of cross-sections to better visualise the configurations.
Whereas in Figure 9a each configuration with t 0 0 is composed of 7 tanks (see Figure 11), the minimum radius constraint reduces this number to 4 for a significant part of t 0 range. Understandably, further increasing the radius threshold extends the reduced tanks region and can bring to configurations with only 1 or 2 tanks.
Considering the trends shown in Figure 9, the main remarks concern:
  • The low sensitivity of e a to t 0 , for which the best solution is given by the case at t 0 = 90° ( e a = 85.7 % ) but lower angles show a small reduction in e a hence still providing a good area coverage (see Figure 12a for an example);
  • The previous observation is valid both with and without the minimum radius constraint;
  • e p is quite insensitive to t 0 if the minimum radius constraint is not applied;
  • The suppression of small tanks due to the minimum radius constraint causes better values of e p .

2.3.2. Part-Section Layout

Part-section layouts are defined with algorithms similar to the full-section one by adding upper and/or lower constraints along the y direction to the available space and removing the symmetry conditions with respect to the horizontal axis.
Figure 11 shows the two possible options in which tanks are installed in the upper part of the fuselage (a), for cases in which the space above the cabin might be sufficient for tank installation, or in the lower part of the fuselage (b), which represents the case in which the lower deck is used for LH 2 storage with a partial or total reduction in the volume assigned to containers. It is worth mentioning that these layouts have the possible advantage of avoiding the reduction in cabin space, hence number of transported passengers, but at the same time can embark smaller LH 2 quantities, hence shorter flyable ranges, if compared to full-section solutions.
In the case depicted in Figure 11a, where the available space is designated through the constraint y y U , up to 5 circles can be constructed starting from the circle 0 U which depends on the tangent point belonging to the ellipse T 0 U , whose position can be defined using the polar coordinate t 0 U which is analogous the full-section parameter t 0 . Then, 0 U radius ( r 0 U ) and centre C 0 U ( x 0 U ,   y 0 U ) can be defined using Equations (13) and (14).
C 0 U :   { x 0 U = c o s   t 0 U + f · c o t   t 0 U · ( y 0 U f · s i n   t 0 U ) y 0 U = y U + f · s i n   t 0 U ( f · c o t   t 0 U ) 2 + 1 1 + ( f · c o t   t 0 U ) 2 + 1
r 0 U = ( x 0 U c o s   t 0 U ) 2 + ( y 0 U f · s i n   t 0 U ) 2
Once 0 U is known, 1 U and 2 U are the defined setting of the tangent conditions to the ellipse, the line y = y U and to 0 U . The same procedure is then perfromed to define 3 U and 3 U , using the tangent condition to 1 U and 2 U , respectively. An as example, Equation (15) shows the system used for the construction of 1 U , whose solution was found numerically using MATLAB vpasolve function. As in Equations (13) and (14), the first two lines set the tangency to the ellipse and to the line y = y U , the third equation sets the tangency to 0 U , and the fourth line specifies on which side of 0 U this condition has to be obtained. Similar systems of equations can be written to define the remaining circles.
{ x 1 U = c o s   t 1 U + f · c o t   t 1 U · ( y 1 U f · s i n   t 1 U ) y 1 U = y U + f · s i n   t 1 U ( f · c o t   t 1 U ) 2 + 1 1 + ( f · c o t   t 1 U ) 2 + 1 ( x 1 U x 0 U ) 2 + ( y 1 U y 0 U ) 2 r 0 U = ( x 1 U c o s   t 1 U ) 2 + ( y 1 U f · s i n   t 1 U ) 2 t 1 U > t 0 U
For the case given in Figure 11b, i.e., considering as constraint y y L , the procedure for defining the circles is analogous to the one here presented.

2.3.3. Presence of Catwalk

The presence of a catwalk is needed to avoid physical separation between pilots’ cabin and any part of passenger decks. This option was implemented only for the full-section layout since it is the only case for which the installation of tanks generates a physical barrier.
The catwalk option has the effect of suppressing only the circle 1 (or 2 ), in order to leave enough space for a side corridor and limiting the reduction in area occupied by the main circle 0 . The algorithm is conceived to suppress 1 (or 2 ) only after the definition of the 3 (or 4 ) couple, in order to use as much as possible of the available section area. As shown in Figure 12, the possibility to use the space assigned to 3 circles, when compatible with minimum radius constraints, allows to partially compensate for the loss of available area due to the introduction of the catwalk.

2.3.4. Multiple Groups of Tanks

The possibility to define more than one group of tanks was implemented in order to simulate the case in which the LH 2 tanks are installed in distinct fuselage compartments with the aim of providing a better mass balance and centre of gravity management. The comparisons were performed under the constraint of keeping the total LH 2 embarked mass unvaried, which is obtained by adapting the length of the central tube of the derived tanks ( L ^ ) according to the approximated relation given by Equation (16), where n t g is the number of tank groups.
L ^ D s t r = L n t g · D s t r 2 3 · n t g 1 n t g · f e n d
The study of the impact of LH 2 tanks on longitudinal equilibrium and stability is out of the scope of the present paper; therefore, this option was introduced only for assessing benefits and drawbacks of dividing the same quantity of embarked LH 2 between more identical tank groups. This option can be used for both full-section and part-section layouts and with any combination of catwalk presence and minimum radius.

2.4. Structural Sizing

The structural sizing of a generic non-integral unstiffened tank is performed combining the approach described by [26], based on Federal Aviation Regulation (FAR) Part-25 ([40]), and the ASME Boiler and Pressure Vessel Code [38]. According to this latter, the allowable tensile stress of the material ( σ a l l ) can be calculated as in Equation (17), in which σ y is the yielding strength and σ u is the ultimate strength of the material, both depending on the operating temperature T .
σ a l l = m i n [ σ y ( T ) 1.5 ;   σ u ( T ) 3.5 ]
Since Equation (17) frames the structural design in the elastic stress–strain interval, only limit conditions prescribed by FAR Part-25 were considered. They are:
  • Difference between internal pressure and external pressure at limit condition ( Δ p ) calculated as in Equation (18):
    Δ p = ( k v e n t · p i n t p c r ) · R F
    where:
    p i n t is the vessel internal pressure, whose reference value is set to 144.8 kPa (21 psi) according to the general conclusions drawn in [26];
    k v e n t is the ratio between the venting pressure ( p v e n t ), i.e., the maximum value that internal pressure reaches during normal operations, and p i n t . According to [26], a typical value of k v e n t is 1.1;
    p c r is the atmospheric pressure at cruise, calculated using the ICAO International Standard Air model for the desired cruise altitude;
    R F is the relief valve tolerance, set to 1.1 according to FAR Part-25 and also adopted in [26].
  • Inertial loads due to flight manoeuvres or gusts at the following (not combined) limit load factors, derived dividing by 1.5 the ultimate values prescribed by FAR Part-25:
    Equal to 3 in the radial direction ( n r ), referred to the most critical case for loads acting in the cross-section plane, i.e., downward loads (ultimate n z = +4.5);
    Equal to 6 in the axial direction ( n x ).
Thermal loads were not considered, since it is assumed the whole metallic structure of the tank, being thermally isolated from the external atmosphere by the insulating layer, is at a constant temperature, hence there are no gradients causing additional stress. In addition, it is assumed that the supporting frames are designed to allow the thermal contraction of the tank structure, which avoids the local introduction of additional loads.
The structural design is then implemented through the following procedure:
  • Given the insulation material thickness ( t i n s ) as an input, the internal radius of the central part of the vessel ( R c i n t ) is initialised with the external radius value R s t r = R t i n s (see Figure 7);
  • The thickness of the vessel cylindrical part ( t c ) is calculated considering welded joints, longitudinal or circumferential, as the most critical areas in which the static strength needs to be verified; therefore, both longitudinal and hoop stresses are calculated and compared to admissible values of the given material and type of joint. The adopted formulas are given in Equation (19), where the first and second expressions provide the thickness resulting from a design for circumferential and longitudinal stress, respectively, whereas the third term is the minimum thickness imposed by [39]. In Equation (19), η w is the welding efficiency as defined in [38], which for butt joints is set to 1 if full radiographic examinations are carried out, 0.85 in the case of spot examinations, and 0.7 otherwise. For the present study, a prudential value of 0.85 was chosen.
    t c = m a x ( Δ p · R c i n t σ a l l · η w 0.6 · Δ p ;   Δ p · R c i n t 2 · σ a l l · η w + 0.4 · Δ p ;   1.6   mm )
The internal radius is updated with the value resulting from R c i n t = R s t r t c and Equation (19) is applied iteratively until t c converges within an assigned threshold.
  • Similarly, the thickness of vessel endcaps ( t e ) is calculated according to [38] using the formula in Equation (20), in which the function k ( f e n d ) is defined in Equation (21) and the second term is introduced to guarantee the applicability of the first expression.
    t e = m a x [ k ( f e n d ) · Δ p · R e i n t σ a l l · η w 0.1 · Δ p ;   5 · 10 4 · L   ; 1.6   mm ]
    k ( f e n d ) = { 2 + f e n d 2 6 1   for   0.0005 t e / L < 0.002 t e / L 0.002  
At the first step it is assumed that R e i n t = R c i n t , then the internal radius is updated with the value resulting from R e i n t = R s t r t e and Equation (20) is iterated until the convergence of t e ;
  • The obtained thickness values allow to calculate the longitudinal mass distributions as well as the total mass of the tank, taking the structure, the insulation layer, and assuming the whole internal volume can be filled with LH 2 ;
  • Given the mass distribution, it is possible to calculate both the maximum (tensile) and minimum (compressive) axial local stress and perform the verifications given in Equation (22). In this latter, the first line is the comparison between the limit longitudinal tensile stress, resulting from both the internal pressure (first term in brackets) and the bending moment, and the strength of the welded material, whereas the second line is the local buckling verification for the cylindrical part of the vessel at ultimate load factors. For buckling design, a null value was assigned to Δ p since a positive value reduces the compressive stress in tanks’ shells. This assumption is conservative, since a minimum Δ p of about 20% of external atmospheric pressure is constantly kept by means of check valves that prevent the inversion of mass flow in the outlets. Column buckling verification was implemented too, but it is not reported here for conciseness, since local bucking is more critical in most of the observed cases.
    { ( Δ p · R c i n t 2 · t c 0.2 · Δ p ) + n r B m a x · R s t r I σ a l l · η w m a x [ 1.5 · n r B m a x · R s t r I c ; 1.5 · n x N m a x π ( R s t r 2 R c i n t 2 ) ] Δ b ( L D s t r , d s u p p L ,   t e ) · 0.125 F S · E · t c R s t r
    The variables in Equation (22) not yet introduced are:
    B m a x , the maximum bending moment, calculated considering both the longitudinal mass distribution varying along the tank and the distance between the supporting frames ( d s u p p );
    N m a x , the maximum compressive axial load;
    I c , the inertia moment of the central tube;
    F S , a design factor defined depending on the ratio between the predicted buckling stress ( σ b ) and the yielding stress as in Equation (23);
    F S = { 2   2.407 0.741 σ b σ y 1.667     for   σ b 0.55 · σ y 0.55 · σ y < σ b < σ y   σ b σ y  
    E , the modulus of elasticity of the structural material;
    Δ b , a correction function, depending on the length-to-diameter ratio ( L / D s t r ), the nondimensional distance between supports ( d s u p p / L ), and endcap wall thickness ( t e ), derived from FEM analyses as described in Section 2.4.1.
The buckling strength, i.e., the terms on the right-hand side of the Equation (22) second and third lines, is derived from the design-by-formula approach given by the “Alternative Rules” of ASME Boiler and Pressure Vessel Code [39] and is the most recurring formula for the tank geometries considered here. The whole set of formulas obtained by varying geometric parameters, such as thickness-to-radius and length-to-radius ratios, was implemented in the design procedure but is not reported here for the sake of conciseness; the reader interested in such details can refer to Section 4.4.12 of [39].
  • If any of the previous verifications is not fulfilled, the thickness t c is recalculated within an iterative loop in which masses and inertial loads are updated at each step.
The following aspects are worth mentioning:
  • Equation (19) as well as the first line of Equation (22) are valid for cylindrical tubes with thickness-to-radius lower than 0.5, whereas Equation (17) is valid for endcaps with thickness-to-radius lower than 0.356. The fulfilment of these constraints is checked at the end of the sizing procedure;
  • The third line of Equation (22) is valid for values of R s t r t c 1000 ([39]), higher values require a design-by-analysis approach to assess adequate protection against buckling;
  • A buckling verification for endcaps was not implemented since they are not subject to compression, as usually happens for tanks that undergo external pressure loads;
  • According to [26], hydrogen tanks need to be verified also at the burst condition, defined as a load case in which only a pressure load equal to twice the limit design pressure ( Δ p ) is applied. In such condition, it is required that the tank can carry the load without catastrophic failures. In the procedure adopted here, Equation (17) introduces a safety factor of 3.5 between the maximum allowable stress and the ultimate strength of the material, hence burst condition is self-verified;
  • For the case of aluminium alloy AA2219, the authors of [26] report a fatigue analysis for a LH 2 -propelled transport aircraft assuming 50,000 service hours corresponding to 10,000 ground–air–ground cycles. For such case, a 172 MPa limitation to circumferential stress of a tank’s skin results in a life reduction factor of 4, i.e., a fatigue life of 40,000 cycles. In the case considered here, taking AA2219 data in Table 4 into account, the allowable value resulting from Equation (17) is 145 MPa, well below the limit indicated above.

2.4.1. Validation of the Structural Model with FEM Analyses

The results of the analytical structural model presented in Section 2.4 were compared with FEM analyses considering the two test cases presented in Table 5, where the last row indicates the value of the correction function Δ b introduced in Equation (22). This was obtained by means of FEM analyses aiming to compare the critical load obtained for buckling eigenvalue equal to unity with the estimation provided by the right-hand term in the 2nd line of Equation (22) without any correction. The FEM simulation campaign was carried out using the two test cases reported in Table 5 as baseline configurations, and varying the parameters that it depends on, in order to cover a wide range of cases of interest.
The two test cases were created in order to underline the differences between structural sizing dominated by tensile or buckling strength. In fact, the 1st case is a tank with a shorter cylindrical part and a higher internal pressure, whereas the 2nd tank is longer and has a larger unbraced length; hence, the design of the 1st cylinder is driven by the circumferential stress acting on welded joints, whereas the 2nd cylinder is designed to withstand buckling loads.
The finite element mesh of each tank is made up of shell elements only; non-structural elements, such as hydrogen and the insulation layer, were modelled as non-structural masses. Different loading conditions were considered as combinations of inertial and pressurisation loads for static sizing verifications. For the bending-induced buckling analyses, only the ultimate downward inertial load was considered; thus, ignoring the beneficial effect of pressurisation on critical load evaluations; the latter was predicted by means of an eigenvalue analysis, according to Equation (24), where P d e a d is a pre-existing applied load (preload or dead load) and ΔP is the perturbation load introduced in the buckling analysis step. For these analyses, a null preload and a perturbed load equal to the ultimate downward inertial load were considered. Normally, the lowest positive eigenvalue is of interest.
P c r = P d e a d + λ i · Δ P
For all the analyses, the structural connections between the tank and the fuselage were modelled as multi-point constraints. In details, at the two sections where the structural supports are located, the points on the longitudinal axis were designated as “master nodes” and multi-point constraint relationships were created with the “slave nodes” located on the cylindrical surface. For one of the master nodes the degrees of freedom associated to radial, azimuthal, and axial displacements are inhibited, whereas the other one differs from the previous only for the axial displacement, which is allowed. Torsion is inhibited by having imposed zero rotation with respect to the longitudinal axis at these points. The system so defined is, thus, isostatic.
The obtained results are summarised in terms of safety factors for both tensile and buckling strength, with a good accordance between the model implemented and FEM analyses (see Table 6). In addition, looking at the values assumed by the safety factors, it can be observed how the design test case #1 is dominated by the strength criterion, whereas test case #2 is driven by buckling.
Figure 13 shows the lowest buckling modes for both test cases; the effective length of the column is comparable to the distance between supports. For the shorter tank, the buckling eigenvalue is about 2.55, whereas for the longer one it is about 1.35; this confirms what was said previously, that the test case 1 is dominated by static sizing, whereas for test case 2 bending-induced buckling is dominant.

2.5. Thermodynamic Analyses

The tank thermodynamic analysis was carried out according to the procedure presented in [24]. The thermodynamic analysis objective is to determine weight, volume, and pressure of the LH 2 contained in the tank, at each point of the mission. This computation is not as simple as for the traditional fuel, since the density of the saturated H 2 is variable with the tank state, and because of the eventuality of venting in case of overpressure. In addition, the analysis needs to check that the H 2 pressure never falls under the minimum pressure to avoid contamination from atmospheric oxygen ([25,33]).

2.5.1. Tank Thermal State Dynamics

Since the H 2 cryogenic storage condition was considered, the internal tank temperature is always lower than the environmental one. This fact generates a heat flux from the environment to the stored H 2 , which leads to a variation in temperature and pressure of the fluid. The laws governing the pressure variation over time in a saturated H 2 homogeneous fluid, in the presence of a heat flux, are reported in [31]. The present paper assumes that the “Passive thermodynamic venting system” case is valid (formula n. 8 in [31]). However, for the sake of simplicity, it is assumed that only the gaseous phase is vented, hence neglecting the refrigeration effect due the vented liquid phase. Therefore, the aforementioned formula is simplified in Equation (25).
d P d t = 2 Φ V [ Q m o ( h g h l ) ( X o + ρ g ρ l ρ g ) ]
m o = m f u e l + m v e n t
X o = m v e n t m o
Φ = 1 ρ ( u P ) ρ
In Equation (25), Q is the heat flux toward the H 2 , V is the tank volume, h g and h l represent the unit mass enthalpy of the gaseous and liquid phase, respectively, whereas ρ g and ρ l are the respective densities.
Because of the presence of the venting valve, the outgoing mass flow ( m o , [kg/s]) is represented by the sum of the mass flow of the liquid phase, headed to the engines ( m f u e l ), and the mass flow of the gaseous phase, expelled by the venting valve ( m v e n t ), as reported in Equation (26). The quality of the outgoing mass flux ( X o ) is the ratio between the gaseous phase mass flow and the total outgoing mass flow (Equation (27)).
According to [25,31], Equation (25) shows a factor 2, in order to take the fluid stratification into account, which is present if proper fluid mixing devices are omitted. The fluid stratification leads to higher pressure variations for a given energy input, if compared to a case in which homogeneous fluid is assumed.
The term Φ in Equation (25) is the “energy derivative”, defined as in Equation (28). More details about its estimation are reported in Appendix A.
The pressure variation inside the tank is determined using Equation (25) in a Eulerian integration in parallel with the mission analysis simulation, as explained in Section 2.6. The mission simulation determines the environmental conditions and the fuel flow ( m f u e l ).
The venting valve mass flow ( m v e n t ) in Equation (25) is determined for the three conditions summarised in Equation (29):
  • While the tank pressure is lower than the venting pressure P < P v e n t , m v e n t is set to zero.
  • When P P v e n t , the venting valve is activated. In this paper, the venting valve mass flow ( m v e n t ) is considered variable in such way that the pressure inside the tank is kept constant. The computation of m v e n t is completed imposing d P / d t = 0 in Equation (25), obtaining the second case of Equation second case of Equation (29) (details in Appendix B). By substituting the computed m v e n t in Equation (25)), the pressure will be kept constant over time.
  • While P P v e n t , an increase in fuel consumption, or a decrease in environmental temperature, will cause a pressure decrease; however, since d P / d t was set to zero, this condition leads to a solution where m v e n t < 0 . In this condition, the computed mass flow is clearly non-physical, since the venting valve is a one-way item. For a correct consideration of this last case, when simultaneously P P v e n t and m v e n t 0 , m v e n t is set to zero:
    m v e n t = { 0 ( b + b 2 4 a c )   / ( 2 a ) 0   i f   P < P v e n t P P v e n t   and   m v e n t > 0 P < P v e n t   and   m v e n t 0
    where:
    a = 1 + ρ g ρ l ρ g  
    b = m f u e l + 2 m f u e l ρ g ρ l ρ g   Q h g h l  
    c = m f u e l 2 ρ g ρ l ρ g   m f Q h g h l  

2.5.2. Tank Heat Flow

The heat flow across the tank walls ( Q in Equation (25))) is computed considering three main thermal exchange stages: the external heat exchange, the heat conduction across the tank insulation, and the heat exchange inside the fluid.
For the sake of simplicity, the following assumptions were introduced:
(a)
Each tank has the same structure shown in Figure 7 and it is assumed that the foam insulation is in direct contact with the external air, which flows at the aircraft flight speed.
(b)
The heat exchange across the tank bulkheads occurs in the same way as for the external diameter. This assumption is less conservative, because the temperature inside the fuselage, in cruise, could be higher than the external one (non-conservative). Moreover, the heat exchange phenomena at the boundary of the insulation inside the fuselage is natural convection, that is different from the forced convection occurring at the boundary with the external environment (conservative). The heat exchange across the bulkheads, however, is strongly dependent upon the passenger compartment wall design, which is out of the scope of this work, so the assumption is considered valid.
(c)
The computation of thermal exchange surfaces was simplified, assuming that the boundaries of every heat exchange phenomenon have the shape of a cylinder of the same overall length of the tank with plane bulkheads.
The external heat exchange is characterised by forced convection and thermal radiation between the external skin of the insulation and the environment; these phenomena are considered by means of the equations reported in [25]. For the convection, we have:
N u = h c o n v · L k a i r = 0.03625 · P r 0.43 · R e 0.8
P r = μ a i r · C p K a i r  
R e = μ a i r · v · L K a i r  
where N u , P r , and R e are the Nusselt, Prandtl, and Reynolds number typical of this phenomenon, h is the heat transfer coefficient [W/(m2 K)], L is the tank length, k a i r is the air thermal conductivity, μ a i r is the dynamic viscosity of the air, C p is the air specific heat at constant pressure, and v is the airspeed.
The radiation to the environment is characterised by the following formula [25,41]:
h r a d = σ   ε ( T s k i n 2 + T a t m 2 ) ( T s k i n + T a t m )  
where h r a d is the heat transfer coefficient of the phenomenon, T s k i n is the aircraft skin temperature, T a t m is the environment temperature, σ is the Stefan–Boltzmann constant, and ε is the emittance of the radiating surface, which is set to 0.95, corresponding to a white painted surface [25]. As for the assumptions (a), (b), and (c), the total external resistance is computed as in Equation (37), where S e x t is the total external surface of the tank at the external foam interface.
T R e x t = 1 S e x t   ( h c o n v + h r a d   )
The thermal resistance of a cylindrical foam layer T R i n s (tube-like problem) is given by the Equation (38), as reported in [25,42]:
T R i n s = 1 2 π l l n ( r o r i ) K i n s  
where r i and r o are the foam internal and external radius, respectively, l is the cylinder length, and K i is the thermal conductivity of the foam. Equation (38) assumes that the foam thermal conductivity is constant along the radius, but this condition is not verified due to the thermal gradient inside the foam, and the foam’s thermal conductivity dependence upon temperature. Because of this fact, it is necessary to split the foam thickness into a number of concentric shells which were set to 40, according to [25]. The heat exchange inside the fluid is characterised by the natural convection in the liquid and gaseous phases. For the liquid phase, the following equations were considered:
N u = 0.0605   R a   1 / 3
R a = g   β   Δ t   H 3   P r ν  
P r = μ   C p   K  
h l = N u   K H l  
where all quantities are relative to the liquid phase, N u , R a , P r , are the Nusselt, Raleigh, and Prandtl numbers for the natural convection inside the liquid H 2 , h l is the heat transfer coefficient of the phenomenon, H l is the level of the liquid part inside the tank, expressed as height from the bottom of the tank, K , C p , β , and ν are, respectively, the thermal conductivity, the specific heat at constant pressure, the coefficient of volumetric thermal expansion, and the cinematic viscosity of the liquid H 2 , whereas Δ t is the temperature difference between the tank wall and the bulk of the liquid H 2 . β was derived as reported in Appendix C. For the gaseous phase the following equations were considered ([25]):
N u = 17  
h g = N u   K H g
where all quantities are relative to the gaseous phase, N u is the Nusselt number for the natural convection inside the gaseous H 2 , h g is the heat transfer coefficient of the phenomenon, H g is the level of the gas inside the tank, expressed as distance from the top of the tank, and K is the thermal conductivity of the gaseous phase. As for assumptions (a), (b), and (c), the total internal thermal resistance is computed as in Equation (45), where S l and S g are the tank surfaces in contact with the liquid and gaseous phase, respectively.
T R int = 1 S l   h l + S g h g    
The heat flow ( Q ) evaluation is computed using the method reported in [24]. The method assume that all the above-mentioned thermal resistances are in series, so the heat flow that crosses each resistance is the same. It is possible to write a linear system of equations in the form A X + B = 0 , as in Equation (46), in order to determine Q and all the temperatures at each tank thermal stage interface:
( 1 0 0   T R e x t 1 1 0 T R i n s 1 0 1 1 T R i n s 2 0 0 1 T R i n t   ) ( T s k i n T i n s 1 T i n s 2 Q     ) + ( T e x t 0 0 T h 2     ) = 0
Since the thermal resistance T R of each thermal stage is dependent upon the temperatures at the thermal stage interfaces, the system is solved with an iterative procedure. It starts with temperature initialisation values identical to the environmental one, and lasts until the convergence on the temperatures at the outer skin and LH 2 interfaces, with a tolerance of 0.5 K.

2.6. Mission Analyses

2.6.1. Reference Aircraft and LH 2 Aircraft Derivation

The box-wing aircraft used as a baseline reference for the study of integration of hydrogen propulsion is one of the results of the European project PARSIFAL ([6,7,8,9,10]). Carried out between 2017 and 2020, PARSIFAL has been funded under the Horizon 2020 programme, with the goal of studying the adoption of box-wing aircraft in the medium-range air transport sector, assessing its operational and environmental impact. One of the objectives of PARSIFAL was to exploit the theoretical aerodynamic superiority of the box-wing lifting system to increase the number of passengers with respect to direct competitors, i.e., Airbus 320 or Boeing 737 family craft, while complying with the same airport constraints and, above all, reducing the fuel consumption per passenger-kilometre ([43]). The designed aircraft has a box-wing architecture with the following main features: a number of passengers equal to 308, 66% more than the conventional competitor; a wingspan equal to 36 metres, and compatible with ICAO category ‘C’ airport aprons ([44]); and a maximum reduction in block fuel per passenger-kilometre equal to 22% compared to the conventional competitor ([45]). Figure 1 presents the final configuration of the PARSIFAL box-wing aircraft, whereas its main characteristics are reported in Table 7; for further details on the study and design of the box-wing aircraft developed within the PARSIFAL project, please refer to [12,43,45].
Table 7, in addition to reporting the main characteristics of the box-wing aircraft used as a baseline for this LH 2 propulsion integration study, also reports how this integration was achieved by modifying the reference aircraft. It should be underlined that the strategy to develop the LH 2 aircraft used in this research is based on the retrofit of the baseline aircraft; this involves a number of constrained design choices that are described hereafter. First, the shape of the aircraft and its main structure are kept the same as that of the baseline. This implies two major effects on the overall aircraft design: firstly, the mass of the main structures of the aircraft, i.e., lifting system, fins, landing gear, and fuselage, is the same as that of the baseline aircraft. Regarding the fuselage structure, the following assumption is made in this study: at this preliminary level it is assumed that the mass of structural components removed to allow the LH 2 tank installation (e.g., floor beams and trusses in the case of the full-section layout) is compensated by the introduction of new structures, such as the frames needed to support the tanks; in other words, the mass balance resulting from the installation of tanks inside the fuselage is almost zero. Secondly, since the external shape of the aircraft is the same as the baseline, the aerodynamic performance is also the same as calculated for the PARSIFAL box-wing aircraft. As the LH 2 tanks are located inside the fuselage, no modifications to the aircraft shape are foreseen; therefore, no new calculations are needed to evaluate the aircraft aerodynamics. All the results on aerodynamic performance were taken from [43].
Concerning the retrofit of the propulsion system, as mentioned in Section 2.1.1, the assumption made is that the turbofan engine of the retrofitted aircraft is the same as the baseline aircraft, except for the introduction of a dedicated heat exchanger.
The main modifications with respect to the baseline box-wing aircraft concern the internal design of the fuselage. In fact, as already explained in Section 2.1.2 and Section 2.3, the cylindrical tanks employed in this study are placed inside the fuselage; this is completed at the expense of the internal volume available to house the payload. This aspect, in addition to the demonstrated larger aerodynamic efficiency of the box-wing architecture, was decisive in the choice of the baseline aircraft to retrofit. Indeed, the PARSIFAL fuselage was designed with a different shape compared to conventional competitors [43]; in particular, the cabin section is enlarged to accommodate 8 passengers per row, and the aft section is designed to maximise the internal volume. Thanks to this fuselage design, it is possible to achieve the above-mentioned payload increase obtained with the PARSIFAL aircraft. The large internal volume provided by this new fuselage design can enable the installation of the required number of tanks in the fuselage, without resulting in compromising penalties in terms of reduction in the number of passengers or in the maximum range. In fact, it is well known that a major drawback of LH 2 tanks is related to the high volume required, and excessive reductions in payload and/or range could jeopardise the effectiveness of the introduction of the LH 2 propulsion system. In order to evaluate the operational capabilities of the retrofitted LH 2 box-wing aircraft, extensive sensitivity studies have been carried out on the number and size of on-board tanks, and on the related impact in terms of payload and range reductions, as reported in detail in Section 3.
The possibility of reducing the number of passengers and/or containers to provide internal fuselage volume to house the LH 2 tanks, involves the need to re-evaluate the weight of some on-board systems and operating items that are directly correlated to the number of passengers. In particular, with respect to the baseline aircraft, for each value of number of passengers evaluated for the retrofitted aircraft, the masses of the interior furnishings, the cabin crew, the seats, the galleys and toilets, the cabin air conditioning system, and the cargo containers, were re-evaluated, as indicated in [46].
The main constraint resulting from the choice to retrofit a baseline aircraft is imposed on the MTOW. Since the main structure of the lifting system and of the fuselage was sized considering the maximum take-off weight calculated in PARSIFAL [47], it is necessary to maintain the same limit on the maximum take-off weight also in this study.

2.6.2. Mission Description and Simulation

This reference mission used to assess the performance of the box-wing aircraft was divided into segments with their own characteristics, as described in the following and schematically shown in Figure 15:
  • Ground holding: is a 30 min standby phase carried out with the engines switched off, which is necessary for fuelling and for other aircraft preparation operations ([24]).
  • Taxi-out: it is conducted according to the Landing and Take-off (LTO) cycle specifications defined by ICAO ([48]); its duration is equal to 13 min, half of the total taxi in and out duration, in which the engine power setting is set to 7% of maximum thrust, corresponding to the idle condition.
  • Take-off: as for the taxi-out phase, the take-off was also computed by using the ICAO engine emissions database specifications; specifically, the duration of the manoeuvre is set to 0.7 min in which the engine power setting is 100%.
  • Take-off path: this segment of the mission acts as a link between the on and off ground mission stages; the take-off flight path starts 35 ft above the ground and ends when the height of 1500 ft is reached. In this stage, the aircraft is configurated for starting the climb ([43]).
  • Climb: this stage is divided into three main phases in which the aircraft accelerates and gains altitude, as suggested by the flight programme described in [49]; the climb ends as the altitude of the cruise condition is reached.
  • Cruise: this segment is performed with a constant speed–constant altitude flight programme; the reference cruise condition is h c r = 11,000 m and M c r = 0.79.
  • Descent: the descent is performed with an imposed speed profile and a constant rate of descent, as described in [43].
The phases outlined above represent what is known as standard mission. In this study, the standard mission was simulated by time-integrating the equations of motion of the aircraft by means of the Euler algorithm, as reported in [45].
In addition to the standard mission, there is a further part of the mission that must be considered when designing an aircraft; this additional phase, called diversion, takes off-design situations, such as weather or technical emergencies, into account. Therefore, diversion is supposed to start after an emergency occurring close to the planned landing and it is meant to divert the aircraft to a new airport, defined as the alternate. Thus, the diversion phase consists of a climb, a cruise at diversion altitude, a descent, a holding phase of 40 min and a landing. An amount of reserve fuel, equal to 5% of the calculated total fuel, is then added at the end of the mission analysis.
In this study, the diversion is not simulated as done for the standard mission phases, and the fuel consumption during the diversion phase is estimated on the basis of the performance data available for the baseline box-wing aircraft ([43]). This simplification was introduced to reduce the simulation time, which for a LH 2 -propelled aircraft is longer than that for a conventional propulsion aircraft, since at each time step both the fuel flow and the state dynamics of the hydrogen inside the tanks vary.
More in detail, the amount of fuel required to perform the descent and diversion, as well as for reserve, is calculated a priori by interpolating the available data of the reference box-wing ([43]) on input values related to the LH 2 aircraft under investigation. Such amount of fuel sets a minimum threshold for the LH 2 to be contained in the tanks at the end of cruise phase. Therefore, the standard mission is simulated until the total fuel in the tanks reaches such threshold value, then the simulation stops and the aircraft performance, such as the flight distance, is obtained in output without the need to iterate.
It is worth remembering that the LH 2 consumption during flight takes both the consumption needed to feed the engines and the amount of H 2 expelled by venting into account, as described in detail in Section 2.4.1. In addition, the mission simulation is prematurely stopped if the pressure inside the tanks drops below the minimum safety pressure.
This coupled mission–thermodynamic analysis depends on the strategy which defines the fuel flow supplied by each tank. For example, venting and pressure drop could be actively contrasted implementing a flow control law depending on the instantaneous internal pressure. For the sake of simplicity and to save computational time, in this preliminary study the same fuel flow value m ˙ f t was assumed for all the active tanks, i.e., those in which LH 2 is not depleted. At each time step, m ˙ f t is calculated as in Equation (48), where m ˙ f e is the fuel flow requested from all the engines and n a t is the number of active tanks. This latter is updated at each time step comparing the quantity of LH 2 left in each tank with a minimum threshold value (70 kg, corresponding to 1 m3).
m ˙ f t ( t ) = m ˙ f e ( t ) n a t ( t )

3. Discussion of Results from Sensitivity Analyses

The following sections report the results of several sensitivity analyses carried out under an aircraft performance-oriented perspective, i.e., using in most of the cases the mission range as the main figure of merit.

3.1. Studies Concerning Tank Materials and Technologies

3.1.1. Sensitivity to Structural Materials

The effects of the several design parameters on the structural design of non-integral tanks made of unstiffened shells LH 2 as the one depicted in Figure 2, were investigated through the sizing procedure described in the previous section considering the different materials reported in Table 4. The figure of merit considered here is the structural mass fraction ( μ s t r ) defined in Equation (48), where M s t r is the total mass of the tank’s walls, V i n t is the gross internal volume of the tank, and ρ L H is the density of the LH 2 .
μ s t r = M s t r V i n t · ρ L H
Figure 16 shows the results of the sensitivity analysis for assigned values of external diameter of the tube, D s t r   = 3 m, and thickness of the insulation layer, t i n s = 0.1 m, which contributes to the inertial loads acting on the structure. The parameters considered are:
  • f e n d , the aspect ratio of endcaps (Figure 16a);
  • L / D s t r , the aspect ratio of the cylindrical tube (Figure 16b);
  • d s u p p / L , the ratio of distance between supports and tube length (Figure 16c);
  • p i n t / p r e f , the ratio between the internal pressure and the reference value of 144.8 kPa (Figure 16d);
  • In each chart, the points highlighted in black indicate the values assigned to the parameters when they are not the object of sensitivity analyses. As a first general comment.
Figure 16 highlights how, in most of the cases, the lower density of the aluminium alloy makes this latter a better compromise than steel or titanium alloy. More in detail, the following remarks can be pointed out:
  • Concerning f e n d , for each selected material it is possible to prescribe a minimum value that avoid the increase in μ s t r . In fact, at low values the endcaps get thicker (see the f e n d effect in Equation (20)) and a snowball effect is produced on the structural mass, as the increase in associated inertial loads pushes towards greater tube thickness to avoid buckling conditions. If, instead, higher f e n d values are considered, endcaps walls do not grow in thickness, but the contained LH 2 mass grows linearly with f e n d , which determines higher inertial loads and eventually produces a slight but constant increase in tube thickness;
  • For L / D s t r , values close to 1 minimise μ s t r , whereas higher values amplify the inertial loads, causing the increase in tube thickness as previously explained. For lower values, the slight increase in μ s t r is only due the reduction in internal volume available for LH 2 mass.
  • The effect of increasing d s u p p / L , visible only for aluminium and titanium alloys, is a higher peak value of the compressive axial load ( N m a x ), which is one of the inputs of the buckling verification in Equation (22). Values of d s u p p / L larger than 1 are possible, meaning that the supporting frames are connected to the endcaps.
Considering p i n t / p r e f , for any of the structural material there are no benefits in increasing the internal pressure, since the main effect would be a reduction in LH 2 density (see Figure 3), hence an increase in μ s t r . The dashed vertical line in Figure 16d indicates the constraint resulting from setting the minimum value of Δ p to 20% of external atmospheric pressure.
Therefore, the present analysis allows to draw some design guidelines:
  • It is suggested to prefer the aluminium alloy AA2219 as structural material;
  • A f e n d value greater than 0.4 should be chosen. In this study, the value 0.6 was selected in accordance with [26], where a value of 1/1.6 is suggested to minimise Direct Operating Costs;
  • A L / D s t r value outside the (1, 1.5) interval should be selected, moving towards higher or lower values depending on the required amount of LH 2 . In the following cases, a value of 1.5 was adopted;
  • A d s u p p / L value lower than 0.8 should be considered. In the following cases, a value of 0.8 has been adopted.
Additional observations can be made for the welding efficiency ( η w ) and the operating temperature, which are both expected to influence the design according to Equations (17), (19) and (20). Results of the analyses, not reported here for brevity, indicate that the effect of η w in the range [0.7, 1] is negligible for all the structural materials considered, whereas the variation in mechanical characteristics with temperatures between 20 and 280 K is barely observable only for the case of AA 2219 above 100 K, well away the cryogenic conditions. Such a low sensitivity is mainly due the adoption of a minimum value for the thickness of tank walls, as prescribed by [39].

3.1.2. Sensitivity to Insulation Materials

As completed for the structural materials, the present section shows the effects of varying the material selected for the insulation layer and t i n s , considering a tank made of AA2219 with L / D s t r = 1.5, d s u p p / L = 0.8, and f e n d = 0.6. Since insulant density influences the structural sizing, the figure of merit considered here is the empty mass fractions μ t a n k , defined according to Equation (49), which is the sum of structural and insulant mass fractions. As can be recognised, lower μ t a n k values are expected to provide better aircraft performance.
μ t a n k = M s t r + M i n s V i n t · ρ L H
A range comparison is provided to evaluate the possible effects on aircraft performance; hence, the external tank radius is adapted as t i n s varies to keep the same V i n t value. Results depicted in Figure 17a show that polystyrene foam (PS), given its lower density, performs better in terms of μ t a n k . Less obvious are the results in terms of flight range given by Figure 17b, which underlines that different insulation foams provide similar range performance, and that this latter improves significantly only up to t i n s values around 100 mm. This indicates that, increasing t i n s above this value, a balance is reached between the reduction in vented LH 2 and the increase in LH 2 consumption due to the overall weight increase.
The constant volume assumption has no practical applications, since if t i n s is increased, the internal radius (hence V i n t ) has to be reduced to keep the compatibility with the section dimensions. Therefore, the following results refer to the same tank considered in the previous analysis, described in Table 8, in which the maximum available radius refers to the PARSIFAL case (Table 1) and insulant material is the polystyrene foam.
The iso-range curves shown in the charts of Figure 18 show that for any value of L / D s t r , longer ranges are achievable if t i n s is close to 50 mm. A possible explanation is that moving from any point of the charts to lower t i n s values, the inertial loads due to the insulant are smaller and lead to thinner tank structures. The lower the thickness of these two layers, the larger the internal radius, which allows to embark the same amount of LH 2 with a shorter tank.
At the same time, reducing t i n s increases the heat exchange, hence a larger fraction of LH 2 is vented-out and a longer tank is needed to compensate this loss. These two opposite effects drive the shape of the iso-range curves shown in the following charts, determining an optimal value of t i n s , that, for the materials’ properties considered here, is around 50 mm. Moreover, this optimality condition is more evident as L / D s t r increases.
Figure 18a indicates that, for an assigned value of t i n s , μ t a n k reaches the lowest values as L / D s t r approaches 1.5, which confirms the choices described at the end of Section 3.1.1. From Figure 18b, it is possible to observe that the gradient of iso- LH 2 curves is well-aligned with the gradient of the iso-range curve only for high values of t i n s , meaning that as this latter decreases the mass of LH 2 is not useful to extend the flight range, i.e., the vented fraction increases. As already observed in Figure 17b, for L / D s t r = 1.5 this alignment is reached when t i n s approaches 100 mm.

3.2. Tanks–Fuselage Integration Studies Based on Full-Section Layouts

3.2.1. Sensitivity to t 0 and t i n s under Different Layout Constraints

The results presented in this section were obtained using the data in Table 8, assigning to t i n s a variable value and setting as a constant the tube length L = 5.9 m (which provides L / D s t r = 1.5 for the main tank, Tank#0). The number of tanks in the section was not fixed a priori and 3 possible conditions were considered: no constraints on the R m i n value (Figure 19a), R m i n = 0.5 m (Figure 19b), and R m i n = 0.5 m with a 0.8-m-wide catwalk (Figure 19c). Some examples of cross-sections are illustrated in Appendix D, for t i n s = 50 mm.
The grey areas in Figure 19 charts indicate that the ( L / D s t r , t i n s ) pair is not able to fulfil the minimum internal pressure requirement for the whole mission duration; therefore, the solution is indicated as not feasible for safety reasons. A possible countermeasure to this problem would be the implementation of a specific pressure-dependent strategy to control the LH 2 outflow from each tank, whereas in this preliminary study a constant LH 2 flow was considered for all the non-empty tanks.
The main observations concerning the results shown in Figure 19 are:
  • The need to define a proper R m i n value is not only related to manufacturability but derives from thermodynamic reasons too. In fact, too small LH 2 volumes are affected by minimum internal pressure problems which lead to a wide unfeasible region (Figure 19a);
  • When the R m i n constraint is introduced, the solutions which maximise the ranges and minimise LH 2 per pax-km consumption, are in the neighbourhood of t 0 = 90° and t i n s = 50 mm and are characterised by only 1 tank in the section (Figure 19b). In this case, the seat capacity is 204;
  • The introduction of the catwalk breaks the symmetry of the solution, moving the optimum far away from the configuration with t 0 = 90°. In the case at hand, the optimal condition is reached for t 0 close to 80°, without any effects on seat capacity.
The LH 2 per pax-km consumption is slightly affected by different number of passengers, which vary because t i n s has a weak but not null effect on tanks’ total lengths, according to Equation (2). The seat capacity of the previous cases can be increased by 1 row for several ( L / D s t r , t i n s ) combinations, whereas few cases allow to add 2 rows.

3.2.2. Sensitivity to L / D str

The results given in this section were obtained considering the data in Table 9, set as reference for a single tank/full section configuration with a catwalk, and assigning L / D s t r the role of variable. The case with the catwalk was selected since it does not introduce a physical interruption in the cabin, hence it is more in line with today’s regulations.
Figure 20a shows the effects of tank’s length on number passengers and range, providing the input to find a trade-off condition.
Although the latter depends on the desired market placement of the aircraft, Figure 20b can support the trade-off study providing relevant information from the environmental impact point of view, such as the consumption per pax-km and the vented LH 2 mass fraction. Figure 20a also shows that if target range is set to equal the harmonic range of the reference aircraft (5722 km, see Table 7), the maximum passenger capacity would be reduced from 308 to 164 units (18 seat rows less). It is worth underlining that the impact of range extension on passenger capacity is actually milder, since for short ranges (<1000 km) there is an initial loss of 56 passengers (7 rows).

3.2.3. Multiple Groups of Tanks

To evaluate pros and cons of using multiple groups of tanks, comparisons with the single tank cases given in Table 8 were performed. For each ( L / D s t r , t i n s ) pair, 2 groups of single tanks were derived, under the constraint of keeping the total LH 2 embarked mass unvaried (Equation (16)).
With 2 tanks, the number of endcaps is doubled, hence the fuselage portion that needs to be transformed from the passenger cabin into the tank bay is longer. For the cases at hand, such difference leads to a reduction in 2 or 3 seat rows (16–24 passengers), depending on t i n s value, which leads to take-off weight reduction (2%, on average).
Figure 21a shows that the double tank solution exhibits lower μ t a n k values as t i n s decreases, and in most cases, it also reduces the vented hydrogen amount. The weight reduction, as well as the advantages introduced in structural and thermodynamic behaviour, determine an increase in flight range, which as Figure 21b shows, is more significant as t i n s is reduced.
By setting L / D s t r = 2.5 and t i n s = 50 mm, it was observed that, compared to the case of a single group, the range increases of 6% and 10% for 2 and 3 groups of tanks were observed, respectively, whereas there is a penalisation in terms of passenger capacity (−10% and −20% approximatively). It is worth mentioning that a multiple tank solution allows to deal with other aspects not faced in the present work, such as aircraft balancing, stability, and control, with more flexibility.

3.3. Tanks–Fuselage Integration Studies Based on Part-Section Layouts

The part section layout has the advantage of avoiding the reduction in passenger capacity, since tanks can be located under the cabin floor, although this would limit the volume available for freight and checked baggage.
In this section, results of achievable performance refer to the data reported in Table 10, in which 2 tank groups were considered in order to increase the embarked LH 2 .
As Figure 22a shows, the maximum range is close to 3800 km which is about 65% of the reference aircraft harmonic range. Such solution, characterised by high aspect-ratio tanks ( L / D s t r = 2.5) with thin insulation layers (<50 mm), allows also to reach LH 2 per pax-km consumption values as low as 5 g/pax/km.
In addition, the total length of both the tanks’ groups is close to 10 m (Figure 22b), which appears to be compatible with the fuselage dimensions. The white areas in Figure 22 refer to cases in which the tank volume is not sufficient to complete the mission.

4. Conclusions

The present paper illustrates a parametric approach for the investigation, at conceptual level, of the performance of short–medium-range aircraft with hydrogen propulsion. Aiming at assessing the impact of introducing LH 2 propulsion systems on aircraft performance, a retrofitting approach focused on effect of cryogenic tanks integration in given aircraft geometries was adopted. LH 2 tanks were modelled as non-integral pressure vessels, composed of a central tube and semi-ellipsoidal endcaps, and were sized to fit into the fuselage of a reference aircraft, under the assumption that its main aerodynamic, flight mechanic and structural characteristics were not affected. The chosen reference aircraft for such purpose is a box-wing short–medium-range airplane, resulting from a previous European research project called PARSIFAL, which has been proven to cut the fuel consumption per passenger-kilometre up to 22%, with similar benefits on CO 2 emissions and global warming potential. This is the result of exploiting the superior aerodynamic efficiency of the box-wing systems to design a wider fuselage, increasing the 6-seat abreast of conventional comparable aircraft to 8, while keeping the wingspan within the same limit of 36 m. Therefore, the combination of available internal volume and high aerodynamic performance given by the box-wing architecture represents the scientific foundation of this study, aiming at a first assessment of the operational capacity given by the LH 2 propulsion.
By acting on few geometric parameters, the approach allows to define a wide variety of fuselage-tank cross-section layouts, with the possibility of varying the number, size, and position of tanks. In addition, it is possible to introduce a catwalk constraint, which allows to create a corridor next to the tanks, and to multiply the number of tank groups along the fuselage axis. An assessment workflow was also implemented to perform the structural sizing of the tanks and analyse their thermodynamic behaviour during the mission.
The structural model, based on the ASME Boiler and Pressure Vessel Code, was calibrated by means of FEM analyses mostly devoted to estimating the buckling resistance, since it is the sizing criterion for most of the tanks with a length-to-diameter ratio ( L / D s t r ) higher than 1. Sensitivity analyses were performed varying the structural materials, selected among typical metallic alloys used for cryogenic applications, and observing that the lighter material, i.e., the aluminium alloy AA2219, although the lower mechanical characteristics minimise the structural mass fraction of tanks. The structural analyses also provided a set of guidelines to assign a value to geometric parameters such as the endcaps aspect ratio ( f e n d > 0.4), length-to-diameter ratio ( L / D s t r > 1.5), and non-dimensional distance between supports ( d s u p p / L < 0.8).
The LH 2 present in the tank is constantly subject to evaporation and, depending on the internal pressure, it is expelled in gas form; therefore, its depletion depends both on the fuel request and to these venting mechanics, which both have an influence on flight range. Therefore, this latter was estimated by simulating the flight missions with a time-marching approach that couples the fuel request from engines with the thermodynamics of the LH 2 in the tanks, whose surface is completely covered by an insulation layer. Therefore, sensitivity analyses of flight range to insulant material and its thickness were performed, indicating that better performance is achieved using polystyrene foam with thickness around 50 mm. This latter optimal condition is more evident as L / D s t r increases.
Given such preliminary results concerning the tanks’ shape and their technological aspect, the focus of the study was moved towards the possible fuselage–tank cross-section layouts. Part-section layouts, with tanks located under the cabin floor, do not affect passenger capacity and allow to achieve flight ranges up to 4000 km (about 65% of the reference aircraft harmonic range). For longer ranges, a full-section layout, provided with a catwalk corridor for safety reasons, is required. These solutions are designed to maximise the embarked LH 2 in the given fuselage cross section but leads to a reduction in passenger capacity proportional to tanks’ lengths. In fact, in the range interval between 4000 and 6000 km, the number of passengers reduces from 196 to 164, against 308 of the part-section layouts. Figure 23 summarises the most relevant results in terms of transport capabilities, i.e., passenger capacity and harmonic range, compared to the reference aircraft. As shown, aiming at a high passenger capacity goal, a part-section layout is preferable, whereas the full-section layout, with the LH 2 mass stored in more than one group of tanks, is a better solution to cover longer flight ranges. In addition, multiple tanks allow more flexibility in dealing with aircraft balancing, stability, and control, which are not faced in this work and should be part of future investigations. Since each solution is associated to different tanks’ lengths, any choice needs to be verified with respect to the actual availability of fuselage volume.
Concerning open problems and possible further development paths for this research, it is worth mentioning the implementation of a flow control strategy, depending on internal pressure and capability of limiting both venting and minimum pressure problems, the integration of constraints about flight mechanics (e.g., effects of longitudinal trim and stability at each time step), the implementation of a thermodynamic model capable of taking the mutual interaction between tank installed in the same fuselage portion into account, as well as more detailed studies about the structural connection between the tanks and the fuselage, with the implementation of a higher fidelity model to estimate the aircraft empty weight.

Author Contributions

Conceptualization, V.C. and D.Z.; Data curation, V.C., D.Z. and V.B.; Formal analysis, V.C., D.Z. and V.B.; Methodology, V.C., D.Z., K.A.S. and V.B.; Software, V.C., D.Z., K.A.S., V.B. and G.P.; Supervision, V.C.; Validation, V.C., D.Z. and V.B.; Visualization, V.C., D.Z. and V.B.; Writing—original draft, V.C., D.Z. and K.A.S.; Writing—review & editing, V.C., D.Z., K.A.S., V.B. and G.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A. Energy Derivative

The term Φ in Equation (25) is the “energy derivative” and is defined in Equation (28), according to [31]. This term is non-dimensional; however, its interpretation is easier if represented with the units of [Pa/(J/m3)]. These units identify the energy derivative as the pressure rise per unit energy input in a unit volume [25]. It is worth noting that the energy derivative is defined for the homogeneous fluid and not on specific phase quantities, and that is variable during the mission.
The energy derivative relative to a state can be computed starting from Equation (28), considering a closed rigid tank of unit volume, with the same homogeneous fluid pressure P and density ρ (or specific volume v ) of the considered state. The computation is completed according to the following the steps:
  • In the fluid reference condition (state 1), is possible to determine the quality X (Equation (A1)), deriving it from the properties of the saturated H 2 liquid and gaseous phases [40], since they are directly linked to the current pressure.
  • Knowing the quality of the fluid X and the internal energies of each phase ( u g ,   u l again directly determined by the current pressure), it is possible to compute the homogeneous fluid’s overall internal energy ( u ) according to Equation (A2).
  • Adding an arbitrary pressure increase to the tank, the overall density will not change, since it is a closed system. The pressure increase, however, will change the properties of the liquid and gaseous phases (state 2), leading to a variation in the quality X and internal energy u , which can be computed for the new state, again using Equations (A1) and (A2).
  • The part of Equation (28) corresponding to d u / d P can be approximated by Equation (A3). d u / d P is computed at constant overall density, as required by Equation (28), due to the closed tank assumption.
  • Φ can be finally computed by Equation (28) considering the state 1 density
    X = v v l v g v l  
    u = u l + X ( u g u l )  
    Δ u Δ P = u 2 u 1 P 2 P 1  
Figure A1 shows the comparison of the estimation of the energy derivative computed with this method with the graphs reported in [31].
Figure A1. Energy derivative estimation comparison with [31].
Figure A1. Energy derivative estimation comparison with [31].
Applsci 12 06857 g0a1

Appendix B. Venting Mass Flow Computation

When P P v e n t , the venting valve is activated. The venting valve mass flow ( m v e n t ) is considered variable in such way that the pressure inside the tank is kept constant. The computation of m v e n t is completed imposing d P / d t = 0 in Equation (25) as in the following formulas (Equation (A5)).
d P d t = 2 Φ V [ Q m o ( h g h l ) ( X o + ρ g ρ l ρ g ) ] = 0
A = ρ g ρ l ρ g
m o ( X o + A ) = Q h g h l
( m v + m f ) ( m v m v + m f + A ) = Q h g h l
m v 2 m v + m f + m v m f m v + m f + m v A + m f A Q h g h l = 0
B = m f A Q h g h l
m v 2 + m v m f + m v 2 A + m v m f A + m v B + m f B = 0
Since m f is known from the mission analysis, Equation (A10) is a second-grade equation in the venting mass flow m v , which can be solved with the standard second-grade equations solution formula. The solution gives two values of m v , generally one positive and one negative, the correct solution to take is the positive one.

Appendix C. Liquid Hydrogen Thermal Expansion Coefficient Computation

The LH 2 volumetric thermal expansion coefficient knowledge is necessary to estimate the natural convection inside the liquid phase of the saturated H 2 . Unfortunately, this characteristic is not present in the H 2 properties database [36]; however, it is possible to derive it from other properties. The volumetric thermal expansion coefficient β is defined as follows:
V 2 = V 1 + Δ V = V 1 ( 1 + β   Δ T )  
where V 1 and V 2 are the substance volumes before and after a temperature change and Δ T = T 2 T 1 is the difference between the final temperature and the initial one. Equation (A11) could be rearranged as in Equation (A12), considering that temperature increase is acting on the same unit mass of fluid ( M = ρ 1   V 1 = ρ 2 V 2 ).
β = 1 Δ T ( V 2 V 1 1 ) = 1 Δ T ( ρ 1 ρ 2 1 )
By applying Equation (A12) between two arbitrary temperatures, it is possible to determine the volumetric thermal expansion coefficient of the saturated LH 2 , since the density data are known from [36].

Appendix D. Fuselage–Tank Sections of the Full Section Layout Configurations

Figure A2. Fuselage and tank cross-sections: (a) without R m i n constraint; (b) with R m i n = 0.5 m; (c) with R m i n = 0.5 m and catwalk width = 0.8 m.
Figure A2. Fuselage and tank cross-sections: (a) without R m i n constraint; (b) with R m i n = 0.5 m; (c) with R m i n = 0.5 m and catwalk width = 0.8 m.
Applsci 12 06857 g0a2

References

  1. ACARE (Advisory Council for Aviation Research and Innovation in Europe). Strategic Research and Innovation Agenda (SRIA); ACARE: Brussels, Belgium, 2017; Volume 1. [Google Scholar]
  2. European Commission. Flightpath 2050: Europe’s Vision for Aviation. European Commission, Directorate General for Research and Innovation, Directorate General for Mobility and Transport; European Commission: Brussels, Belgium, 2011.
  3. Thomson, R.; Weichenhain, U.; Sachdeva, N.; Kaufmann, M. Hydrogen: A Future Fuel for Aviation? Roland Berger GmbH: Munich, Germany, 2020. [Google Scholar]
  4. Clean Sky 2 JU and FCH 2 JU Report. Hydrogen-Powered Aviation: A Fact-Based Study of Hydrogen Technology, Economics, and Climate Impact by 2050; McKinsey & Company for European Commission: Brussels, Belgium, 2020.
  5. Verstraete, D.; Hendrick, P.; Pilidis, P.; Ramsden, K. Hydrogen fuel tanks for subsonic transport aircraft. Int. J. Hydrogen Energy 2010, 35, 11085–11098. [Google Scholar] [CrossRef]
  6. PARSIFAL Project: “Prandtlplane ARchitecture for the Sustainable Improvement of Future AirpLanes”. EU Horizon 2020, 2017–2020 (GA. 723149). Available online: https://perma.cc/5ULW-HCP4 (accessed on 1 July 2022).
  7. Abu Salem, K.; Binante, V.; Cipolla, V.; Maganzi, M. PARSIFAL project: A breakthrough innovation in air transport. Aerotec. Missili Spaz. 2018, 97, 40–46. [Google Scholar] [CrossRef] [Green Version]
  8. Cipolla, V.; Frediani, A.; Abu Salem, K.; Picchi Scardaoni, M.; Nuti, A.; Binante, V. Conceptual design of a box-wing aircraft for the air transport of the future. In Proceedings of the AIAA Aviation Forum, 2018 Aviation Technology, Integration, and Operations Conference, Atlanta, GA, USA, 25–29 June 2018. [Google Scholar] [CrossRef]
  9. Cipolla, V.; Abu Salem, K.; Picchi Scardaoni, M.; Binante, V. Preliminary design and performance analysis of a box-wing transport aircraft. In Proceedings of the AIAA SciTech 2020 Forum, Orlando, FL, USA, 6–10 January 2020. [Google Scholar] [CrossRef]
  10. Tasca, A.L.; Cipolla, V.; Abu Salem, K.; Puccini, M. Innovative box-wing aircraft: Emissions and climate change. Sustainability 2021, 13, 3282. [Google Scholar] [CrossRef]
  11. Prandtl, L. NACA-TN-182. Induced Drag of Multiplanes; NACA: Cleveland, OH, USA, 1924. [Google Scholar]
  12. Carini, M.; Méheut, M.; Kanellopoulos, S.; Cipolla, V.; Abu Salem, K. Aerodynamic analysis and optimization of a boxwing architecture for commercial airplanes. In Proceedings of the AIAA SciTech 2020 Forum, Orlando, FL, USA, 6–10 January 2020. [Google Scholar] [CrossRef]
  13. NASA Project Bee (B57-B). 1965. Available online: https://www.grc.nasa.gov/WWW/portal/apps/naca/ (accessed on 1 July 2022).
  14. Reynolds, T.W. NACA-RM-E56K08a. Experimental Study of Foam-Insulated Liquified-Gas Tanks; NACA: Cleveland, OH, USA, 1957. [Google Scholar]
  15. Fleming, W.A. NACA-RM-E56E14. Turbojet Performance and Operation at High Altitudes with Hydrogen and JP4; NACA: Cleveland, OH, USA, 1956. [Google Scholar]
  16. Reynolds, T.W. NACA-RM-E55F22. Aircraft-Fuel-Tank Design for Liquid Hydrogen; NACA: Cleveland, OH, USA, 1955. [Google Scholar]
  17. Silverstein, A. NACA-RM-E55C28a. Liquid Hydrogen as a Jet Fuel for High-Altitude Aircraft; NACA: Cleveland, OH, USA, 1955. [Google Scholar]
  18. Berry, W. NASA-CR-112204. A Fuel Conservation Study for Transport Aircraft Utilizing Advanced Technology and Hydrogen Fuel; NASA: Hampton, VA, USA, 1972. [Google Scholar]
  19. Brewer, G.D. NASA-CR-132559. Study of the Application of Hydrogen Fuel to Long Range Subsonic Transport Aircraft; NASA: Burbank, CA, USA, 1975; Volume 2. [Google Scholar]
  20. Snow, D.B. NASA-TM-X-71994. A Study of Subsonic Transport Aircraft Configurations Using H2 and CH4; NASA: Hampton, VA, USA, 1974. [Google Scholar]
  21. Brewer, G.D. NASA CR-2700. LH2 Airport Requirements Study; NASA: Burbank, CA, USA, 1976. [Google Scholar]
  22. CRYOPLANE-Liquid Hydrogen Fuelled Aircraft—System Analysis. Final Technical Report (Published Version), Contract G4RD-CT-2000-00192. Project GRD1-1999-10014; Airbus Deutschland GmbH: Hamburg, Germany, 2003.
  23. Sippel, M.; Kropp, A.; Mattson, D.; Freund, J.; Tapeinos, I.; Koussios, S. Final Results of Advanced Cryo-Tanks Research Project CHATT. In Proceedings of the 6th EUCASS Conference, Krakau, Poland, 29 June–3 July 2015. [Google Scholar]
  24. Winnefeld, C.; Kadyk, T.; Bensmann, B.; Krewer, U.; Hanke-Rauschenbach, R. Modelling and Designing Cryogenic Hydrogen Tanks for Future Aircraft Applications. Energies 2018, 11, 105. [Google Scholar] [CrossRef] [Green Version]
  25. Verstraete, D. The Potential of Liquid Hydrogen for Long Range Aircraft Propulsion. Ph.D. Thesis, Cranfield University, Cranfield, UK, 2009. [Google Scholar]
  26. Brewer, G.D. Hydrogen Aircraft Technology; CRC Press: London, UK, 1991. [Google Scholar]
  27. Corchero, G.; Montanes, L. An approach to the use of hydrogen for commercial aircraft engines. J. Aerosp. Eng. 2005, 219, 35–44. [Google Scholar] [CrossRef] [Green Version]
  28. NACA. NACA-RM-E57D23. Hydrogen for Turbojet and Ramjet Powered Flight; NACA: Cleveland, OH, USA, 1957. [Google Scholar]
  29. Gomez, A.; Smith, H. Liquid hydrogen fuel tanks for commercial aviation: Structural sizing and stress analysis. Aesrospace Sci. Technol. 2019, 95, 105438. [Google Scholar] [CrossRef]
  30. Prewitz, M.; Bardenhagen, A.; Beck, R. Hydrogen as the fuel of the future in aircrafts–challenges and opportunities. Int. J. Hydrogen Energy 2020, 45, 25378–25385. [Google Scholar] [CrossRef]
  31. Lin, C.S. NASA-TM-104409. A Pressure Control Analysis of Cryogenic Storage Systems; NACA: Cleveland, OH, USA, 1991. [Google Scholar]
  32. Mital, S.K. NASA-TM-2006-214346. Review of Current State of the Art and Key Design Issues with Potential Solutions for Liquid Hydrogen Cryogenic Storage Tank Structures for Aircraft Applications; NACA: Cleveland, OH, USA, 2006. [Google Scholar]
  33. Verfondern, K.; Cirrone, D.; Molkov, V.; Makarov, D.; Coldrick, S.; Ren, Z.; Wen, J.; Proust, C.; Friedrich, A.; Jordan, T. Handbook of Hydrogen Safety. Chapter on LH2 safety (Project PRESLHY); Karlsruher Institut fuer Technologie: Karlsruhe, Germany, 2021. [Google Scholar]
  34. Kuhn, M. Storage Density of Hydrogen; Institute of Air Handling and Refrigeration (ILK): Dresden, Germany, 2015; Available online: https://commons.wikimedia.org/wiki/File:Storage_Density_of_Hydrogen.jpg (accessed on 1 July 2022).
  35. Arnold, S.S.; Bednarcyk, B.A.; Collier, C.S.; Yarringhton, P.W. Spherical Cryogenic Hydrogen Tank preliminary Design Trade Studies, AIAA 2007-2290. In Proceedings of the 48th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference, Honolulu, HI, USA, 23–26 April 2007. [Google Scholar]
  36. National Institute of Standards and Technology. Thermophysical Properties of Fluid Systems; National Institute of Standards and Technology: Boulder, CO, USA, 2007. Available online: http://webbook.nist.gov/chemistry/fluid/ (accessed on 1 July 2022).
  37. Schwartzberg, F.R.; Osgood, S.H.; Keys, R.D.; Kiefer, T.F. Cryogenic Materials Data Handbook; PB 171809; AFRL: Patterson Air Force Base: Dayton, OH, USA, 1966. [Google Scholar]
  38. ASME Boiler and Pressure Vessel Code, Rules for Construction of Pressure Vessels. Section VIII, Division 1; American Society of Mechanical Engineers: New York, NY, USA, 2017.
  39. ASME Boiler and Pressure Vessel Code, Rules for Construction of Pressure Vessels (Alternative Rules). Section VIII, Division 2; American Society of Mechanical Engineers: New York, NY, USA, 2017.
  40. Federal Aviation Regulation, Title 14, Chapter I, Subchapter C, PART 25. Airworthiness Standards: Transport Category Airplanes. Available online: https://www.ecfr.gov/current/title-14/chapter-I/subchapter-C/part-25 (accessed on 1 July 2022).
  41. Rohsenow, W.M.; Hartnett, J.R.; Young, I.C. Handbook of Heat Transfer, 3rd ed.; McGraw-Hill: New York, NY, USA, 1998. [Google Scholar]
  42. Lienhard, J.H., IV; Lienhard, J.H., V. A Heat Transfer Textbook, 3rd ed.; Phlogiston Press: Cambridge, MA, USA, 2008. [Google Scholar]
  43. Abu Salem, K. Development of Design Tools and Methods for Box-Wing Airplanes and Application of the PrandtlPlane Concept to a Short-Medium Range Aircraft. Ph.D. Thesis, University of Pisa, Pisa, Italy, 2021. Available online: https://etd.adm.unipi.it/ (accessed on 1 July 2022).
  44. International Civil Aviation Organization. Aerodromes: Volume I—Aerodrome Design and Operations. International Standards and Recommended Practices; ICAO Annex 14: Montréal, QC, Canada, 2009. [Google Scholar]
  45. Abu Salem, K.; Cipolla, V.; Palaia, G.; Binante, V.; Zanetti, D. A physics-based multidisciplinary approach for the preliminary design and performance analysis of a medium range aircraft with box-wing architecture. Aerospace 2021, 8, 292. [Google Scholar] [CrossRef]
  46. Beltramo, M.; Trapp, D.L.; Kimoto, B.W.; Marsh, D.P. NASA CR151970. Parametric Study of Transport Aircraft Systems Cost and Weight; NASA: Moffett Field, CA USA, 1977.
  47. Cipolla, V.; Abu Salem, K.; Palaia, G.; Binante, V.; Zanetti, D. A DoE-based approach for the implementation of structural surrogate models in the early stage design of box-wing aircraft. Aerosp. Sci. Technol. 2021, 117, 106968. [Google Scholar] [CrossRef]
  48. International Civil Aviation Organization. ICAO Aircraft Engine Emissions Databank. 2019. Available online: https://www.easa.europa.eu/easa-and-you/environment/icao-aircraft-engine-emissions-databank (accessed on 1 July 2022).
  49. Airbus. Getting to Grips with Aircraft Performance; Airbus SAS: Leiden, The Netherlands, 2002; Available online: https://perma.cc/FQ9P-FET4 (accessed on 1 July 2022).
Figure 1. PARSIFAL project: (a) artistic representation of the box-wing aircraft object of study; (b) comparison between cabin cross-sections for conventional (top) and PARSIFAL cases (bottom).
Figure 1. PARSIFAL project: (a) artistic representation of the box-wing aircraft object of study; (b) comparison between cabin cross-sections for conventional (top) and PARSIFAL cases (bottom).
Applsci 12 06857 g001
Figure 2. Storage density of hydrogen for different pressure and temperature conditions ([34]).
Figure 2. Storage density of hydrogen for different pressure and temperature conditions ([34]).
Applsci 12 06857 g002
Figure 3. Temperature–pressure (a) and density–pressure (b) relations for saturated H 2 .
Figure 3. Temperature–pressure (a) and density–pressure (b) relations for saturated H 2 .
Applsci 12 06857 g003
Figure 4. Thermal conductivity of insulation foams.
Figure 4. Thermal conductivity of insulation foams.
Applsci 12 06857 g004
Figure 5. Illustration of possible tanks–fuselage integration layouts: (a) full-section with “catwalk”, (b) part-section with cargo deck occupation, (c) multiple groups of tanks (full-section case).
Figure 5. Illustration of possible tanks–fuselage integration layouts: (a) full-section with “catwalk”, (b) part-section with cargo deck occupation, (c) multiple groups of tanks (full-section case).
Applsci 12 06857 g005
Figure 6. Scheme of the analysis method workflow.
Figure 6. Scheme of the analysis method workflow.
Applsci 12 06857 g006
Figure 7. Longitudinal section of a generic hydrogen tank composed of a cylindrical central part and two semi-ellipsoidal endcaps, both covered by an external layer of insulation material (in blue).
Figure 7. Longitudinal section of a generic hydrogen tank composed of a cylindrical central part and two semi-ellipsoidal endcaps, both covered by an external layer of insulation material (in blue).
Applsci 12 06857 g007
Figure 8. Full-section layout: steps for definition of the space available for the tanks within the fuselage cross-section: (a) definition of the main tank cross-section, (b) introduction of mid-size side tanks, (c) introduction of an additional couple of tanks on the left-side, (d) introduction of an additional couple of tanks on the right-side.
Figure 8. Full-section layout: steps for definition of the space available for the tanks within the fuselage cross-section: (a) definition of the main tank cross-section, (b) introduction of mid-size side tanks, (c) introduction of an additional couple of tanks on the left-side, (d) introduction of an additional couple of tanks on the right-side.
Applsci 12 06857 g008aApplsci 12 06857 g008b
Figure 9. Geometric performance of full-section layout for f = 0.75 and various t 0 values: (a) no constraints on minimum radius values, (b) minimum radius set to 10% of fuselage half-width.
Figure 9. Geometric performance of full-section layout for f = 0.75 and various t 0 values: (a) no constraints on minimum radius values, (b) minimum radius set to 10% of fuselage half-width.
Applsci 12 06857 g009
Figure 10. Examples of full-section layouts without minimum radius constraints for three different t 0 values: (a) 0°, (b) 70°, (c) 90°.
Figure 10. Examples of full-section layouts without minimum radius constraints for three different t 0 values: (a) 0°, (b) 70°, (c) 90°.
Applsci 12 06857 g010
Figure 11. Part-section layouts: (a) available space in the upper part of the cross-section; (b) available space in the lower part of the cross-section.
Figure 11. Part-section layouts: (a) available space in the upper part of the cross-section; (b) available space in the lower part of the cross-section.
Applsci 12 06857 g011
Figure 12. Examples of full-section layout for t 0 = 40°: (a) without catwalk ( e a = 83%; e p = 31%), (b) with catwalk ( e a = 67%; e p = 45%), (c) with catwalk and minimum radius constraint ( e a = 56%; e p = 100%).
Figure 12. Examples of full-section layout for t 0 = 40°: (a) without catwalk ( e a = 83%; e p = 31%), (b) with catwalk ( e a = 67%; e p = 45%), (c) with catwalk and minimum radius constraint ( e a = 56%; e p = 100%).
Applsci 12 06857 g012
Figure 13. Visualisation of buckling analysis results for test cases #1 (a) and #2 (b) under ultimate downward inertial loads ( n r = 4.5 ).
Figure 13. Visualisation of buckling analysis results for test cases #1 (a) and #2 (b) under ultimate downward inertial loads ( n r = 4.5 ).
Applsci 12 06857 g013
Figure 14. Drag polar curve of the box-wing aircraft studied in the project PARSIFAL ([45]).
Figure 14. Drag polar curve of the box-wing aircraft studied in the project PARSIFAL ([45]).
Applsci 12 06857 g014
Figure 15. Standard mission simulation scheme.
Figure 15. Standard mission simulation scheme.
Applsci 12 06857 g015
Figure 16. Structural mass fraction ( μ s t r ) for different materials and design parameters: (a) f e n d , (b) L / D s t r , (c) d s u p p / L , and (d) p i n t / p r e f .
Figure 16. Structural mass fraction ( μ s t r ) for different materials and design parameters: (a) f e n d , (b) L / D s t r , (c) d s u p p / L , and (d) p i n t / p r e f .
Applsci 12 06857 g016aApplsci 12 06857 g016b
Figure 17. Influence of insulant material selection and layer thickness ( t i n s ) on empty mass fraction μ t a n k (a) and range flown (b), assuming the same internal volume available for LH 2 .
Figure 17. Influence of insulant material selection and layer thickness ( t i n s ) on empty mass fraction μ t a n k (a) and range flown (b), assuming the same internal volume available for LH 2 .
Applsci 12 06857 g017
Figure 18. Sensitivity to length-to-diameter ratio ( L / D s t r ) and insulant thickness ( t i n s ) with indication of flight range: (a) empty mass fraction ( μ t a n k ) and (b) embarked LH 2 mass.
Figure 18. Sensitivity to length-to-diameter ratio ( L / D s t r ) and insulant thickness ( t i n s ) with indication of flight range: (a) empty mass fraction ( μ t a n k ) and (b) embarked LH 2 mass.
Applsci 12 06857 g018
Figure 19. Sensitivity of number of tanks (left) and burnt LH 2 per pax-km (right) to t 0 and t i n s , with range indication: (a) without R m i n   constraint; (b) with R m i n = 0.5 m; (c) with R m i n = 0.5 m and catwalk width = 0.8 m.
Figure 19. Sensitivity of number of tanks (left) and burnt LH 2 per pax-km (right) to t 0 and t i n s , with range indication: (a) without R m i n   constraint; (b) with R m i n = 0.5 m; (c) with R m i n = 0.5 m and catwalk width = 0.8 m.
Applsci 12 06857 g019aApplsci 12 06857 g019b
Figure 20. Sensitivity to L / D s t r : (a) range and seat capacity, (b) burnt LH 2 per pax-km and vented mass fraction.
Figure 20. Sensitivity to L / D s t r : (a) range and seat capacity, (b) burnt LH 2 per pax-km and vented mass fraction.
Applsci 12 06857 g020
Figure 21. Comparison between 2 tanks and 1 tank configurations with the same embarked LH 2 : (a) relative μ t a n k and vented LH 2 variations, (b) relative range variation (reference values: 1 tank).
Figure 21. Comparison between 2 tanks and 1 tank configurations with the same embarked LH 2 : (a) relative μ t a n k and vented LH 2 variations, (b) relative range variation (reference values: 1 tank).
Applsci 12 06857 g021
Figure 22. Part-section layout (cargo deck) with 2 groups of tanks: (a) sensitivity of burnt LH 2 per pax-km to L / D s t r and t i n s , (b) total length of tanks (2 groups).
Figure 22. Part-section layout (cargo deck) with 2 groups of tanks: (a) sensitivity of burnt LH 2 per pax-km to L / D s t r and t i n s , (b) total length of tanks (2 groups).
Applsci 12 06857 g022
Figure 23. Summary of transport capabilities for some of the investigated LH 2 aircraft configurations compared to the reference aircraft (308 pax, 5722 km), for both part-section (PS) and full-section (FS) integration layouts.
Figure 23. Summary of transport capabilities for some of the investigated LH 2 aircraft configurations compared to the reference aircraft (308 pax, 5722 km), for both part-section (PS) and full-section (FS) integration layouts.
Applsci 12 06857 g023
Table 1. Main characteristics of the box-wing aircraft studied in the project PARSIFAL.
Table 1. Main characteristics of the box-wing aircraft studied in the project PARSIFAL.
ParameterBox-Wing Aircraft
Aircraft overall length44.32 m
Aircraft overall height9.43 m
Fuselage internal height (max.)4.05 m
Fuselage internal width (max.)5.40 m
Fuselage cross-section aspect ratio (height/width)0.75
Cabin layoutDouble aisle, 2-4-2 abreast
Seat pitch0.744 m
Maximum seat capacity308
Table 2. Level of detail of most relevant studies reported in state-of-the-art analyses.
Table 2. Level of detail of most relevant studies reported in state-of-the-art analyses.
StudyField of StudyLevel of Detail
[17,18,19,20,24,25]Aircraft designConceptual, aircraft level
[26]Aircraft designConceptual, aircraft and systems level
[15,28]EngineExperimental
[27]EngineConceptual
[14]TankExperimental
[16,31,32]TankConceptual
[29]TankConceptual and FEM analysis
Table 3. Properties of insulant materials.
Table 3. Properties of insulant materials.
Material ρ i ,   Density   [ kg / m 3 ] K i ,   Conductivity   [ W / ( m   K ) ]  
Polystyrene foam (PS)25.60.015–0.045
Polymethacrylimide foam (PMI)51.10.005–0.037
Polyurethane foam (PRU)32.00.005–0.025
Table 4. Properties of structural metallic materials at cryogenic conditions (T = 20 K), for 1.6-mm-thick sheets ([37]).
Table 4. Properties of structural metallic materials at cryogenic conditions (T = 20 K), for 1.6-mm-thick sheets ([37]).
Material Treatmentsσy, Yielding Strength at T = 20 K
[MPa (103 psi)]
σu, Ultimate Tensile Strength at T = 20 K
[MPa (103 psi)]
E, Modulus of Elasticity at T = 20 K
[GPa (106 psi)]
ρs, Density [kg/m3]
Stainless steel grade 301 (SS301)Tempered (3/4 hardened) 1585 (230)2000 (290)207 (30)7890
Aluminium alloy 2219 (AA2219)Heat-treated, cold worked, then artificially aged (T8) 448 (65)655 (95)76 (11)2825
Titanium alloy
Ti-5Al-2.5Sn
Extra-low interstitial grade, annealed1344 (195)1655 (240)124 (18)4480
Table 5. Input and output of the analytical model for two test cases.
Table 5. Input and output of the analytical model for two test cases.
InputTest Case #1Test Case #2
D s t r [m]3.003.00
L / D s t r [−]1.002.00
f e n d [−]0.600.60
d s u p p / L [−]0.700.90
p i n t / p r e f   ( p r e f = 144.8 kPa)1.401.00
t i n s [mm]100100
Structural material and characteristics AA 2219 (Table 4)AA 2219 (Table 4)
Insulation material and characteristicsPolystyrene foam (Table 3)Polystyrene foam (Table 3)
OutputTest Case #1Test Case #2
t c [mm]2.12.4
t e [mm]1.73.0
Tube structural mass [kg]166383
Endcaps (2) structural mass [kg]97175
Total insulant mass [kg]132207
Total tank empty mass [kg]395765
Internal volume [m3]29.650.7
Allowable tensile stress on welded joints [MPa]159159
Nominal buckling strength (long cylinders) [MPa]6.67.6
FEM derived correction factor Δ b [−]0.500.83
Table 6. Safety factors calculated for the structural test cases.
Table 6. Safety factors calculated for the structural test cases.
Safety FactorsTest Case #1Test Case #2
ASME ([38,39])FEMASME ([38,39])FEM
Tube—longitudinal tensile stress [−]1.992.033.183.18
Tube—circumferential tensile stress [−] 1.001.001.691.67
Endcap—tensile stress [−]1.000.982.662.55
Tube Buckling Buckling stress [−]1.811.821.321.35
1st Eigenvalue [−] -2.55-1.35
Table 7. Characteristics of the LH 2 aircraft derived by the reference aircraft.
Table 7. Characteristics of the LH 2 aircraft derived by the reference aircraft.
ParameterReference Aircraft
(PARSIFAL)
Retrofit Methodology LH 2   Aircraft
Passenger capacity308Full-section: depending on tanks’ length
Part-section: unchanged
Full-section: variable (≤308)
Part-section: 308
Cabin crew7Depending on passenger capacityVariable (≤7)
Number of containers12Depending on tank lengthVariable (≤12)
Empty mass [kg]
  • Overall engine mass
13,676Increased by 1% (see Section 2.1.1)13,813
  • Structural mass
30,996Unchanged30,996
  • System mass
9466Depending on passenger capacity (according to [46])Variable (air conditioning, containers)
  • Operating mass
14,180Depending on passenger capacity (according to [46])Variable
  • Tanks and fuel system mass
548Increase in total empty mass of LH 2 tanksVariable
Fuel mass [kg]27,000 (Kerosene)CalculatedVariable ( LH 2 )
Max. take-off weight [kg]125,126CalculatedVariable (≤125,126)
SFC [kg/kg/s]1.39 × 10−4Decreases by 64.71% (see Section 2.1.1)4.87 × 10−5
Drag polar curveSee Figure 14UnchangedSee Figure 14
Harmonic range [km]5722 kmCalculatedVariable
Table 8. Data on the reference single tank/full section configuration.
Table 8. Data on the reference single tank/full section configuration.
ParameterValueCross-Section (Example)
Maximum tank radius (R) [m]2.02 Applsci 12 06857 i001
Tank layoutFull-section
Number of tanks in the section1
N. of tank groups ( n t g ) 1
R m i n [m]0.50
Catwalk width [m]Not present
t 0 90°
t i n s [mm]Variable
L / D s t r Variable
D s t r [m]Variable
d s u p p / L 0.80
f e n d 0.60
Table 9. Data on the reference single tank/full section configuration with a catwalk.
Table 9. Data on the reference single tank/full section configuration with a catwalk.
ParameterValueCross-Section (Example)
Maximum tank radius (R) [m]2.02 Applsci 12 06857 i002
Tank layoutFull-section
Number of tanks in the section1
N. of tank groups ( n t g ) 1
R m i n [m]0.50
Catwalk width [m]0.80
t 0 80°
t i n s [mm]50
L / D s t r Variable
D s t r [m]3.94
d s u p p / L 0.80
f e n d 0.60
Table 10. Data on the reference multi tank/part-section configuration (cargo deck).
Table 10. Data on the reference multi tank/part-section configuration (cargo deck).
ParameterValueCross-Section (Example)
Maximum tank radius (R) [m]2.02 Applsci 12 06857 i003
Tank layoutPart-section ( y L = −0.50 m)
Number of tanks in the sectionVariable
N. of tank groups ( n t g ) )2
R m i n [m]0.25
Catwalk width [m]Not present
t 0 −90°
t i n s [mm]Variable
L / D s t r Variable
D s t r [m]Variable
d s u p p / L 0.80
f e n d 0.60
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Cipolla, V.; Zanetti, D.; Abu Salem, K.; Binante, V.; Palaia, G. A Parametric Approach for Conceptual Integration and Performance Studies of Liquid Hydrogen Short–Medium Range Aircraft. Appl. Sci. 2022, 12, 6857. https://0-doi-org.brum.beds.ac.uk/10.3390/app12146857

AMA Style

Cipolla V, Zanetti D, Abu Salem K, Binante V, Palaia G. A Parametric Approach for Conceptual Integration and Performance Studies of Liquid Hydrogen Short–Medium Range Aircraft. Applied Sciences. 2022; 12(14):6857. https://0-doi-org.brum.beds.ac.uk/10.3390/app12146857

Chicago/Turabian Style

Cipolla, Vittorio, Davide Zanetti, Karim Abu Salem, Vincenzo Binante, and Giuseppe Palaia. 2022. "A Parametric Approach for Conceptual Integration and Performance Studies of Liquid Hydrogen Short–Medium Range Aircraft" Applied Sciences 12, no. 14: 6857. https://0-doi-org.brum.beds.ac.uk/10.3390/app12146857

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.