Next Article in Journal
Rheological Properties, Particle Size Distribution and Physical Stability of Novel Refined Pumpkin Seed Oil Creams with Oleogel and Lucuma Powder
Next Article in Special Issue
Evaluating the Impacts of Climate Factors and Flavonoids Content on Chinese Prickly Ash Peel Color Based on HPLC-MS and Structural Equation Model
Previous Article in Journal
The Effect of Pressure–Shift Freezing versus Air Freezing and Liquid Immersion on the Quality of Frozen Fish during Storage
Previous Article in Special Issue
Glucosinolates as Markers of the Origin and Harvesting Period for Discrimination of Bee Pollen by UPLC-MS/MS
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Simultaneous Determination of Nine Quinolones in Pure Milk Using PFSPE-HPLC-MS/MS with PS-PAN Nanofibers as a Sorbent

1
College of Food Engineering, Anhui Science and Technology University, Chuzhou 233100, China
2
Anhui Guoke Testing Technology Co., Ltd., Hefei 230000, China
*
Author to whom correspondence should be addressed.
Submission received: 12 May 2022 / Revised: 11 June 2022 / Accepted: 16 June 2022 / Published: 22 June 2022
(This article belongs to the Special Issue Application of LC-MS/MS in Food Analysis and Quality Control)

Abstract

:
In this study, a packed-fiber solid-phase extraction (PFSPE)-based method was developed to simultaneously detect nine quinolones, including enrofloxacin (ENR), ciprofloxacin (CIP), ofloxacin (OFL), pefloxacin (PEF), lomefloxacin (LOM), norfloxacin (NOR), sarafloxacin (SAR), danofloxacin (DAN), and difloxacin (DIF), in pure milk, using high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). Polystyrene (PS) and polyacrylonitrile (PAN) were combined to form PS-PAN composite nanofibers through electrospinning. The nanofibers were used to prepare the home-made extraction columns, and the process was optimized and validated using blank pure milk. The analytical method showed high accuracy, and the recoveries were 88.68–97.63%. Intra-day and inter-day relative standard deviations were in the ranges of 1.11–6.77% and 2.26–7.17%, respectively. In addition, the developed method showed good linearity (R2 ≥ 0.995) and low method quantification limits for the nine quinolones (between 1.0–100 ng/mL) for all samples studied. The nine quinolones in the complex matrix were directly extracted using 4.0 mg of PS-PAN composite nanofibers as a sorbent and completely eluted in 100 μL elution solvent. Therefore, the developed PFSPE-HPLC-MS/MS is a sensitive and cost-effective technique that can effectively detect and control nine quinolones in dairy products.

1. Introduction

Milk is a nutritious liquid food produced by animals that is a key nutritional source for humans. Milk production also significantly contributes to the global economy. Antibiotic treatments protect animals from infections such as mastitis [1]. However, inappropriate use of antibiotics such as quinolones can deteriorate the quality of milk and other dairy products. Since quinolones are effectively used to resist Gram-positive and Gram-negative bacteria, they are widely applied for therapeutic purposes [2]. Animal products may contain some fractions of antibiotics due to excessive antibiotic treatment. The antibiotic remaining in the animal products can potentially have severe consequences on human health via the food chain [3]. Thus, monitoring the residues of quinolones in dairy products is vital to human health. The control of veterinary drug residues is an important measure for ensuring consumer protection [4]. Therefore, an efficient and sensitive method for detecting quinolones should be developed and validated to monitor the residues in food, ensuring the healthy consumption of dairy products.
A variety of analytical methods such as diode array UV [5,6], fluorescence [7,8], mass spectrometry (MS) [9,10,11], and capillary electrophoresis (CE) [5,12] have been applied to determine the quinolones in dairy products. Due to the complex matrices and low fluoroquinolone (FQ) concentrations in food samples, suitable sample pretreatment is usually required to remove interfering matrix components and enrich the analytes to appropriate concentrations for subsequent analysis, irrespective of the analytical method selected. To reduce matrix effects (ME), remove interferences, and improve the efficiency of the method [13], the samples are pretreated using various extraction techniques, including solid-phase extraction (SPE) [5,6,7], liquid–liquid extraction (LLE) [2], and online SPE [10], to extract target analytes with different solvents. However, conventional extraction methods such as LLE [14,15] and SPE [16] suffer from low selectivity or a long analysis time, because solvent evaporation to dryness is required. Moreover, large volumes of organic solvents are consumed, which are harmful to human health.
Packed-fiber solid-phase extraction (PFSPE), as a novel SPE technique, could simplify the process of sample preparation. Purification, concentration, and desorption could be undertaken in one step, without using a membrane filter, heating for evaporation, and drying in a nitrogen stream. In addition to the above features, electrospun nanofibers use a smaller sorbent-bed mass due to their unique physicochemical properties (such as a large surface-area-to-volume ratio), reducing the quantity of organic solvents and increasing extraction efficiencies for trace analyses [17]. Thus, electrospun nanofibers are a good potential sorbent material for SPE-based techniques [18,19]. In many research studies, polystyrene/polypyrrole (PS/PPy) nanofibers have become one of the most promising materials for potential applications [20]. PPy/PAN nanofibers have been used as extraction materials for cationic dyes in wastewater [21].
In this study, polyacrylonitrile-polystyrene (PAN-PS) composite nanofibers (a selective sorbent) were prepared and characterized. A PFSPE-based method, with PAN-PS nanofibers (as the adsorbent) and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), was used to detect nine quinolones, namely, enrofloxacin (ENR), ciprofloxacin (CIP), ofloxacin (OFL), pefloxacin (PEF), lomefloxacin (LOM), norfloxacin (NOR), sarafloxacin (SAR), danofloxacin (DAN), and difloxacin (DIF), in pure milk samples. In addition, this method was used to compare the extraction efficiencies of PAN and PAN-PS nanofibers. Other important parameters influencing the extraction efficiency, such as the concentration of eluant, the amount of adsorbent, the ionic strength, and the reusability of the PAN-PS nanofibers, were investigated and optimized. Finally, the method was used to detect nine quinolones in plain milk.

2. Materials and Methods

2.1. Materials and Reagents

Analytical grade chemicals and reagents were used. N,N-Dimethylformamide (DMF), poly-acrylonitrile (PAN, retained molecular weight: 150,000 Da), polystyrene (PS, retained molecular weight: 192,000 Da), enrofloxacin (ENR), ciprofloxacin (CIP), ofloxacin (OFL), pefloxacin (PEF), lomefloxacin (LOM), norfloxacin (NOR), sarafloxacin (SAR), danofloxacin (DAN), and difloxacin (DIF) were purchased from Shanghai Macklin Biochemical company (Shanghai, China, www.macklin.cn.qianyan.biz (accessed on: 11 May 2022)). Methanol (CH3OH, HPLC-grade), acetonitrile (CH3CN, HPLC-grade), formic acid (HCOOH, HPLC-grade), sulfuric acid (H2SO4), sodium chloride (NaCl), and EDTA–McIlvaine buffer (pH4.0) were all purchased from Aladdin company (Shenzhen, China, www.aladdin-e.com (accessed on: 11 May 2022)).
Single stock solutions of 0.1 mg/mL of the nine quinolones, namely, ENR, CIP, OFL, PEF, LOM, NOR, SAR, DAN, and DIF in methanol were separately prepared. The working mixture solutions were prepared via appropriate dilution of the stock solutions with 1.0 ng/mL, 5.0 ng/mL, 20.0 ng/mL, 50.0 ng/mL, and 100.0 ng/mL of pure water at 4 °C in a volumetric flask.

2.2. Equipment and HPLC-MS-MS Conditions

The separation of the nine quinolones from the pure milk extracts was performed using an HPLC system (Agilent 1200 Series HPLC system, Agilent Technologies, Santa Clara, CA, USA) placed in an Anhui Guoke Testing Technology Co., Ltd. (www.guoketest.com.cn (accessed on: 11 May 2022)) system consisting of a vacuum degasser, an autosampler, and a binary pump, equipped with a reversed-phase SB-C18 analytical column (2.1 × 100 mm, 2.7 μm particle size, Agilent Technologies, Santa Clara, CA, USA). The mobile phase consisted of 0.1% of formic acid in water (A) and acetonitrile (B). Gradient conditions such as 0–1.0 min (95% A), 1.1–4.0 min (2% A), and 4.1–6.0 min (95% A) were set up, and the flow rate was maintained at 0.3 mL/min.
The mass spectrometric acquisition was performed on an Agilent 6460 triple quadrupole mass spectrometer (Agilent Technologies, Palo Alto, CA, USA) equipped with an electrospray ionization source to generate positive ions [M + H]+. In order to achieve the best ionization of the nine quinolones, an ion spray voltage of 4.0 kV in the positive mode was employed. The nebulizing gas was nitrogen (99.999%), and the rate was 7.0 L/min. The temperature of the symmetrical heaters was 300 °C, and the flow rate of the sheath gas was 11 L/min. Finally, the injection volume was 2 μL. The retention time, precursor ion, ionic product, and collision energy for each analyte are listed in Table 1.

2.3. Preparation of PS-PAN Nanofibers

PS-PAN nanofibers were fabricated as follows. First, PAN (15%, w/v) solution was prepared by dissolving an appropriate amount of PAN in the DMF solvent to form a polymer solution. PS (5%, w/v) was added to the polymer solution after the PAN was completely dissolved. The mixed electrospinning solution was stirred at 6000 rpm at an ambient temperature of 23~25 °C. Then, it was loaded into the glass syringe, which was equipped with a steel needle with a tip diameter of 0.33 mm. Finally, the conditions for electrospinning were as follows: an anodic voltage of 22 kV, a distance between the tip of the needle and the collector of 15 cm, and a mixed electrospinning solution flow rate of 2.0 mL/h. The nanofibers were collected on the collector and dried at room temperature.

2.4. Characterization

The surface morphologies of the electrospun fibers were observed using a scanning electron microscope (SEM, Supra55, ZEISS, Jena, Germany) at 20 kV. The average diameter of the electrospun fibers was determined by analyzing 30 single fibers using the Nano Measurer software, version 1.2 (Nanjing, China). The molecular structure of the nanofiber membrane was confirmed using ATR-IR spectroscopy (FTIR, NicoletiS10, Thermo Fisher, Waltham, MA, USA), carried out in the 4000–500 cm−1 range. The X-ray diffraction analysis was carried out using an X-ray diffractometer (XRD, XD-3X, Persee General, Beijing, China), and the XRD spectra were recorded over a 2θ range of 5° to 60°, with a step of 0.02°.

2.5. Sample Pretreatment

Pure milk (150 mL, Yili) was purchased from a local supermarket in Chuzhou, China. According to the method described in the literature, one sample was used as the blank sample without quinolones [22]. The preparation of the milk sample included the following steps: (i) 2.0 mL milk was added into a 50 mL centrifuge tube; (ii) nine quinolones (ENR, CIP, OFL, PEF, LOM, NOR, SAR, DAN, and DIF) with appropriate concentrations (2 ng/mL, 10 ng/mL, and 25 ng/mL) were added to the sample; (iii) 10.0 mL of EDTA–McIlvaine buffer solution (pH 4.0) was added to the mixed solution; (iv) the mixture was sonicated for 20 min and centrifugated at 10,000 rpm for 30 min before the supernatant was separated; and (v) the total supernatant was transferred to a clean tube and stored at 4 °C before the pretreatment using PFSPE.
To effectively implement the extraction, 4.0 mg of nanofibers was packed into the PFSPE column at the tip end of the storage cartridge [23]. Then, the column was activated using 200 μL of methanol and 200 μL of deionized water. A 500 mL volume of supernatant was loaded into the gas-tight plastic syringe and then pushed through the sorbent under atmospheric pressure. Targets adsorbed on the nanofibers were eluted using 100 μL of eluent, as shown in Figure 1. Hence, the extraction recovery was calculated following Equation (1):
q = (A1/5/A0) × 100%
where A0 is the peak area of 10 μL of the nine quinolones standard solution and A1 is the peak area of 10 μL of the nine quinolones eluent solution.

2.6. Method Validation

Different standard solutions were prepared and verified through PFSPE-HPLC-MS/MS to validate the linearity, precision, detection limit (LOD), and quantification (LOQ) limit under optimal conditions. The linearity was determined by analyzing standard solutions ranging from 1.0 to 100 ng/mL in blank pure milk. The standard solution with the lowest concentration (2.0 ng/mL) of the nine quinolones was analyzed to obtain the LOD and LOQ, which were calculated for signal-to-noise ratios (S/N) of 3 and 10, respectively. The relative standard deviation (% RSD) was used as the precision and calculated according to the reproducibility (intra-day precision, n = 3 and inter-day precision, n = 6). In this study, the matrix-matched slope divided by the solvent-based slope equals the ME, and the formula is:
((slope matrix − matched/slope solvent) × 100).

3. Results and Discussion

3.1. Characterization of Nanofibers

Compared with PAN nanofibers, no significant morphological change was observed in the SEM images of PAN-PS nanofibers (Figure 2a,b). In addition, the rough surface of the PAN-PS nanofibers, compared with PAN nanofibers, remained unchanged. The diameter size distributions of different PAN-PS and PAN nanofibers are shown in Figure 2a’,b’. The mean diameters of the PAN and PAN-PS nanofibers were 0.6 μm and 0.9 μm, respectively. The nanofibers were uniform and dense with a network structure. However, there were few beads and several beads on PAN nanofibers and PAN-PS nanofibers, respectively.

3.2. Molecular Interactions of Nanofibers

The Fourier transform infrared spectrometry (FTIR) spectra of the PAN and PAN/PS nanofibers are shown in Figure 3. The characteristic peaks of PAN nanofibers were composed of conjugated C−N stretching at 2242 cm−1 and −CH2− stretching vibrations at 1450 cm1 and 2491 cm−1. After blending the PS, as shown in the spectrum for PAN/PS nanofibers, many new peaks appeared in the IR spectra of the PAN/PS nanofibers. The new peaks at 698 cm−1 and 756 cm−1 were absorption peaks due to C−H vibrations in the PS benzene ring. The above results indicate that the combination of PAN and PS does not produce new chemical bonds but exists as PAN/PS composite nanofibers.

3.3. X-ray Diffraction Analysis (XRD)

X-ray diffractograms of the PAN nanofibers, PS nanofibers, and PAN/PS nanofibers are shown in Figure 4. The broad diffraction peaks at 2θ = 10° and 20° are the diffraction peaks of PS nanofibers. The sharp diffraction peaks at 2θ = 16° and 26° indicate the highly crystalline nature of PAN nanofibers. The XRD pattern of PAN/PS nanofiber membranes exhibited a similar pattern to the PAN nanofibers and PS nanofibers. Sharp diffraction peaks were observed at 2θ = 16° and 26°. The broad peak at 2θ = 10°, corresponding to PS, did not appear in the XRD pattern of PAN/PS nanofibers. Moreover, the lower intensity of the peaks at 2θ = 16° and 26° suggested that the overall crystallinity of the PAN/PS nanofibers was slightly lower than that of PS but higher than that of PAN nanofibers. The results showed that pure PAN and PS particles were physically mixed and generated strong molecular interactions.

3.4. Comparison of Adsorption Efficiencies between PAN Nanofibers and PAN/PS Composite Nanofibers

First, the effect of the nanofiber characteristics on the efficiency of extraction was investigated. In this study, the extraction recoveries of the two types of nanofibers prepared with different frameworks were evaluated. The extraction recoveries of PAN/PS composite nanofibers for nine quinolones (ENR, CIP, OFL, PEF, LOM, NOR, SAR, DAN, and DIF) were 97.5%, 99.2%, 93.2%, 98.8%, 93.2%, 98.3%, 87.6%, 98.6%, and 89.1%, respectively, and these values were much higher than those for pure PAN nanofibers. The target analytes were difficult to detect due to the polymeric nature of PAN and the existence of strong chemical bonds between its molecules. Moreover, the result could be explained using the interaction mechanism between PAN-PS and the analytes, due to the conjugated π–π structure in the PS backbone, which showed a strong interaction between the analytes. A hydrogen bonding interaction could also exist between the polymer and analytes.
After extraction, quinolones were desorbed from the sorbents using eluent prior to HPLC-MS/MS analysis. To determine the optimal elution solvent, 100 μL of 70% (v/v) methanol, 80% (v/v) methanol, 90% (v/v) methanol, and 1% (v/v) sulfuric acid/70% methanol were evaluated (Figure 5b). Low recoveries were observed when the various concentrations of methanol were used, but an increase in recovery was observed after 1% sulfuric acid was added (Figure 5c). Compared with the desorption ability of 70% methanol, 1% formic acid/70% methanol exhibited higher recovery rates (82.4–100.7%).
The amount of PAN-PS nanofibers played a vital role in the recovery of the nine quinolones. If there are insufficient nanofibers, the target analytes cannot be completely adsorbed; however, excessive nanofibers may lead to incomplete elution. As shown in Figure 5d, as the amount of nanofibers increased from 3.0 mg to 4.0 mg, the recovery of the nine targets increased significantly. However, for amounts of nanofibers ranging from 5.0 mg to 8.0 mg, the elution rates of the nine targets decreased significantly. Therefore, 4.0 mg of 15% polyacrylonitrile and 5% polystyrene composite nanofibers was selected for solid-phase extraction in this study.
To explore the effect of salt addition on the extraction of the nine quinolones, different concentrations (0%, 2%, 4%, 6%, 8%, and 10.0% w/v of the analytes) were added to the samples. The addition of salt to the samples reduced the solubility of the analytes and the amount of the analytes extracted [24]. Figure 5e shows that there were no significant changes in extraction efficiency. Hence, adjustment of the ionic strength was not necessary in this study.
To exhibit the reproducibility of the synthesis of sorbent, the extraction recoveries of the nine quinolones were tested. As shown in Figure 5f, the extraction recoveries were almost the same under the same conditions of synthesis and pretreatment of the nine quinolones. The results indicate that the PAN/PS composite nanofibers exhibited good chemical and mechanical stability and reproducibility.

3.5. Method Validation

The reproducibility, linearity, and LOD were investigated under optimal conditions. Milk samples were randomly obtained from a local market in Chuzhou (China). According to the national standard method, one of the milk samples without the nine quinolones was selected as a blank for calibration and validation.
Under optimum conditions, everyday snack samples spiked with the nine quinolones were employed for analyzing the methodological parameters. As shown in Table 2, good linearity was found in the range of 1.0−100 ng/mL for the nine quinolones. The coefficients of correlation (R2) ranged from 0.9992 to 0.9999. The LODs of all analytes were in the range of 0.16–0.39 ng/mL, and the LOQs were in the range of 0.53−1.29 ng/mL, indicating that the method can effectively determine the nine quinolones in plain milk samples. As shown in Table 2 and Table 3, a high efficiency of extraction was found for all analytes in the pure milk sample. Recoveries were obtained over a reasonable range from 88.68% to 97.63% for the nine analytes in the spiked concentration samples. The intra-day range for the three spiked concentration samples was from 1.11% to 6.77%, and the inter-day RSD was in the range 2.26−7.17%. All these values are below 12%.

3.6. Matrix Effect

The extraction and analysis of the nine quinolones in pure milk could be affected by other factors. If the value of the matrix effect (ME) is 100%, this shows that there is no interference from the matrix; however, if the value is more than 100%, it shows that the ME enhances the analysis signal. Finally, if the value is less than 100%, the ME reduces the signal [25]. The results for the ME were evaluated and are summarized in Table 4. Although the ME values of the nine analytes were less than 100%, they all ranged from 94.2% to 98.3%. Therefore, the effect of matrix interference on the analysis signal of pure milk was insignificant.

3.7. Comparison of This Method with Other Measurement Methods

The advantages of the developed method for detecting the nine quinolones in plain milk are summarized in Table 5. The developed method was compared with various preparation methods in the existing literature. Firstly, the fabricated PS-PAN nanofibers were used to analyze the nine quinolones in plain milk for the first time. Secondly, the sample pretreatment required no evaporative drying with nitrogen or treatment of the filter membrane. Generally, the procedure is simplified and easy to master.

3.8. Application to Real Samples

The samples were then spiked with ENR, CIP, OFL, PEF, LOM, NOR, SAR, DAN, and DIF standards at 50 ng/mL levels, to assess the matrix effects. Nine quinolones were detected in milk samples, as shown in Figure 6. This results show that the developed method can effectively detect quinolones in samples where they cannot be detected using the standard method.

4. Conclusions

The PFSPE-based PAN-PS composite nanofibers were used as sorbents to simultaneously extract and analyze nine quinolones (ENR, CIP, OFL, PEF, LOM, NOR, SAR, DAN, and DIF) in pure milk, using HPLC-MS/MS. After the optimization of the process, the method showed good linearity, precision, LOD, and LOQ, with high accuracy, and low ME values. The analytical method showed high accuracy, with recoveries of 88.68−97.63%. Intra-day and inter-day relative standard deviations were in the ranges of 1.11−6.77% and 2.26−7.17%, respectively. In addition, the developed method showed good linearity (R2 ≥ 0.995) and low method quantification limits for the nine quinolones (between 1.0−100 ng/mL) in all samples studied. Moreover, compared with the sample pretreatment in conventional methods, the sample pretreatment in the developed method required no evaporative drying under nitrogen or filter membrane treatment. The results show that PFSPE-HPLC−MS/MS is a sensitive and cost−effective technique for detecting nine quinolones in plain milk. However, there are also some limitations. For example, the column packing is not automated. If it could be automated, the consistency of detection would be improved considerably.

Author Contributions

J.L. conceived the research. L.W. performed the research, analyzed the data, wrote the manuscript, and designed the experiments. Y.C. analyzed and interpreted the data. D.S. participated in preparing samples. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Key Research and Development Projects of Anhui Province (grant No. 202104f06020007), the Key Projects of Anhui Provincial Department of Education (grant No. KJ2021A0888), the Key Projects of Anhui Science and Technology University (grant No. 2021zrzd12), Anhui Provincial Major Science and Technology Project (18030701212), the Talent Foundation of Anhui Science and Technology University (SPYJ 202001), and the College Students’ Innovative Entrepreneurial Training Plan Program (202110879050).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data is contained within the article.

Acknowledgments

We thank Anhui Guoke Testing Technology Co., Ltd. (www.guoketest.com.cn) for preparing samples and supplying equipment.

Conflicts of Interest

Samples and equipment were provided by Anhui Guoke Testing Technology Co., Ltd. (www.guoketest.com.cn) in this study. The authors declare no conflict of interest.

References

  1. Oliveira, R.V.; Pietro, A.C.D.; Cass, Q.B. Quantification of cephalexin as residue levels in bovine milk by high-performance liquid chromatography with on-line sample cleanup. Talanta 2007, 71, 1233–1238. [Google Scholar] [CrossRef] [PubMed]
  2. Fan, Y.X.; Gan, X.; Li, S.; Qin, W.D. A rapid CE-potential gradient detection method for determination of quinolones. Electrophoresis 2007, 28, 4101–4107. [Google Scholar] [CrossRef]
  3. Xu, J.; Li, X.; Li, C.; Xiao, Y. Hexafluoroisopropanolinduced salt-free catanionic surfactant coacervate extraction method for determination of fluoroquinolones in milk samples. Food Chem. 2018, 242, 122–130. [Google Scholar] [CrossRef] [PubMed]
  4. Beucher, L.; Dervilly-Pinel, G.; Prévost, S.; Monteau, F.; Le, B. Determination of a large set of b-adrenergic agonists in animal matrices based on ion mobility and mass separations. Anal. Chem. 2015, 87, 9234–9242. [Google Scholar] [CrossRef] [PubMed]
  5. Cinquina, A.L.; Longo, F.; Anastasi, G.; Giannetti, L.; Cozzani, R. Validation of a high-performance liquid chromatography method for the determination of oxytetracycline, tetracycline, chlortetracycline and doxycycline in bovine milk and muscle. J. Chromatogr. A 2003, 987, 227–233. [Google Scholar] [CrossRef]
  6. Christodoulou, E.A.; Samanidou, V.F. Multiresidue HPLC analysis of ten quinolones in milk after solid phase extraction: Validation according to the European Union Decision 2002/657/EC. J. Sep. Sci. 2007, 30, 2421–2429. [Google Scholar] [CrossRef]
  7. Idowu, O.R.; Peggins, J.O. Simple, rapid determination of enrofloxacin and ciprofloxacin in bovine milk and plasma by high-performance liquid chromatography with fluorescence detection. J. Pharmaceut. Biomed. 2004, 35, 143–153. [Google Scholar] [CrossRef]
  8. Zheng, M.M.; Rui, G.; Xing, Z.; Feng, Y.Q. Selective sample pretreatment by molecularly imprinted polymer monolith for the analysis of fluoroquinolones from milk samples. J. Chromatogr. A 2010, 1217, 2075–2081. [Google Scholar] [CrossRef]
  9. Bogialli, S.; Curini, R.; Corcia, A.D.; Nazzari, M.; Sergi, M. Confirmatory analysis of sulfonamide antibacterials in bovine liver and kidney: Extraction with hot water and liquid chromatography coupled to a single- or triple-quadrupole mass spectrometer. Rapid Commun. Mass Spectrom. 2010, 17, 1146–1156. [Google Scholar] [CrossRef]
  10. Kantiani, L.; Farré, D.; Barceló, M. Rapid residue analysis of fluoroquinolones in raw bovine milk by online solid phase extraction followed by liquid chromatography coupled to tandem mass spectrometry. J. Chromatogr. A 2011, 1218, 9019–9027. [Google Scholar] [CrossRef]
  11. Lombardo-Agüí, M.; García-Campa, A.M.A.; Gámiz-Gracia, L.; Cruces-Blanco, C. Determination of quinolones of veterinary use in bee products by ultra-high performance liquid chromatography-tandem mass spectrometry using a QuEChERS extraction procedure. Talanta 2012, 93, 193–199. [Google Scholar] [CrossRef] [PubMed]
  12. Lombardo-Agüí, M.; Gámiz-Gracia, L.; García-Campaña, A.M.; Cruces-Blanco, C. Sensitive determination of fluoroquinolone residues in waters by capillary electrophoresis with laser-induced fluorescence detection. Anal. Bioanal. Chem. 2009, 396, 1551–1557. [Google Scholar] [CrossRef] [PubMed]
  13. González-Gómez, L.; Morante-Zarcero, S.; Pérez-Quintanilla, D.; Sierra, I. Simultaneous Determination of Furanic Compounds and Acrylamide in Insect-Based Foods by HPLC-QqQ-MS/MS Employing a Functionalized Mesostructured Silica as Sorbent in Solid-Phase Extraction. Foods 2021, 10, 1557. [Google Scholar] [CrossRef] [PubMed]
  14. Li, X.Q.; Zhang, Q.H.; Ma, K.; Li, H.M.; Guo, Z. Identification and determination of 34 water-soluble synthetic dyes in foodstuff by high performance liquid chromatography-diode array detection-ion trap time-of-flight tandem mass spectrometry. Food Chem. 2015, 182, 316–326. [Google Scholar] [CrossRef] [PubMed]
  15. Martin, F.; Oberson, J.M.; Meschiari, M.; Munari, C. Determination of 18 water-soluble artificial dyes by LC-MS in selected Matrices. Food Chem. 2016, 197, 1249–1255. [Google Scholar] [CrossRef] [PubMed]
  16. Hong, J.; Kawashima, A.; Okamoto, M.; Kanetsuki, K.; Makino, T.; Hamada, N. Fundamental study of a novel membrane filtration cleanup method for pesticide analysis in agricultural products. Food Control. 2016, 64, 1–9. [Google Scholar] [CrossRef]
  17. Chigome, S.; Torto, N. A review of opportunities for electrospun nanofibers in analytical chemistry. Anal. Chimi. Acta 2011, 706, 25–36. [Google Scholar] [CrossRef]
  18. Chigome, S.; Torto, N. Electrospun nanofiber-based solid-phase extraction. Trends Anal. Chem. 2012, 38, 21–31. [Google Scholar] [CrossRef] [Green Version]
  19. Chigome, S.; Darko, G.; Torto, N. Electrospun nanofibers as sorbent material for solid phase extraction. Analyst 2011, 136, 2879–2889. [Google Scholar] [CrossRef] [Green Version]
  20. Qi, F.; Qian, L.; Liu, J.; Li, X.; Lu, L.; Xu, Q. A high-throughput nanofibers mat based micro-solid phase extraction for the determination of cationic dyes in wastewater. J. Chromatogr. A 2016, 1460, 24–32. [Google Scholar] [CrossRef]
  21. Qi, F.; Jian, N.; Qian, L.; Cao, W.; Xu, Q.; Li, J. Development and optimization of a novel sample preparation method cored on functionalized nanofibers mat-solid phase extraction for the simultaneous efficient extraction of illegal anionic and cationic dyes in foods. Anal. Bioanal. Chem. 2017, 409, 5697–5709. [Google Scholar] [CrossRef] [PubMed]
  22. Jian, N.G.; Zhao, M.; Liang, S.H.; Cao, J.K.; Wang, C.M.; Xu, Q.; Li, J. High-Throughput and High-Efficient Micro-solid Phase Extraction Based on Sulfonated-Polyaniline/Polyacrylonitrile Nanofiber Mats for Determination of Fluoroquinolones in Animal-Origin Foods. J. Agric. Food Chem. 2019, 67, 6892–6901. [Google Scholar] [CrossRef] [PubMed]
  23. Wei, L.L.; Song, Y.; Liu, P.; Kang, X.J. Polystyrene nanofibers capped with copper nanoparticles for selective extraction of glutathione prior to its determination by HPLC. Microchim. Acta 2018, 185, 321. [Google Scholar] [CrossRef]
  24. Wang, Y.; Tong, Y.; Xu, X.; Zhang, L. Metal-organic framework-derived three-dimensional porous graphitic octahedron carbon cages-encapsulated copper nanoparticles hybrids as highly efficient enrichment material for simultaneous determination of four fluoroquinolones. J. Chromatogr. A 2018, 1533, 1–9. [Google Scholar] [CrossRef] [PubMed]
  25. Kopf, T.; Schmitz, G. Analysis of non-esterified fatty acids in human samples by solidphase-extraction and gas chromatography/mass spectrometry. J. Chromatogr. B 2013, 938, 22–26. [Google Scholar] [CrossRef] [PubMed]
  26. National Standard Method. Determination of 14 Quinolones Residues in Animal-original Food by HPLC-MS/MS. 2007. Available online: https://max.book118.com/html/2019/0617/5044013312002044.shtm (accessed on 10 May 2022).
  27. Hong, J.W.; Liu, X.M.; Yang, X.Y.; Wang, Y.S. Ionic liquid-based dispersive liquid-liquid microextraction followed by magnetic solid-phase extraction for determination of quinolones. Microchimi. Acta 2022, 153, 022003. [Google Scholar] [CrossRef]
  28. Kergaravat, S.V.; Nagel, O.G.; Althaus, R.L.; Silvia, R.H. Detection of quinolones in milk and groundwater samples using an indirect immunofluorescent magneto assay. Int. J. Environl. Anal. Chem. 2020, 1–18. [Google Scholar] [CrossRef]
  29. Ye, Z.; Huang, Y.; Luo, Q.; Wang, L.; Huang, X. Preparation of highly fluorinated and boron-rich adsorbent for magnetic solid-phase extraction of fluoroquinolones in water and milk samples. J. Chromatogr. A 2019, 1601, 86–94. [Google Scholar] [CrossRef]
  30. Wang, G.N.; Yang, K.; Liu, H.Z.; Feng, M.X.; Wang, J.P. Molecularly imprinted polymer-based solid phase extraction combined high performance liquid chromatography for determination of fluoroquinolones in milk. Anal. Methods 2016, 8, 5511–5518. [Google Scholar] [CrossRef]
  31. Liu, C.; Yang, L.Y.; Zhang, W.; Li, D.W.; Li, L.A.; Wang, H.Y.; Ma, Y.; Li, C. A magnetic nanoparticle-based lateral flow immunochromatography assay for the rapid detection of fluoroquinolones in milk. Eur. Food Res. Technol. 2021, 247, 2645–2656. [Google Scholar] [CrossRef]
  32. Zhang, X.; Wang, C.; Yang, L.; Zhang, W.; Lin, J.; Li, C. Determination of eight quinolones in milk using immunoaffinity microextraction in a packed syringe and liquid chromatography with fluorescence detection. J. Chromatogr. B 2017, 1064, 68–74. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Schematic of packed-nanofiber solid-phase extraction process.
Figure 1. Schematic of packed-nanofiber solid-phase extraction process.
Foods 11 01843 g001
Figure 2. The SEM images of (a) PAN nanofibers and (b) PAN-PS nanofibers and the size distributions of (a’) PAN nanofibers and (b’) PAN-PS nanofibers.
Figure 2. The SEM images of (a) PAN nanofibers and (b) PAN-PS nanofibers and the size distributions of (a’) PAN nanofibers and (b’) PAN-PS nanofibers.
Foods 11 01843 g002
Figure 3. FTIR spectra of PAN nanofibers and PAN/PS composite nanofibers.
Figure 3. FTIR spectra of PAN nanofibers and PAN/PS composite nanofibers.
Foods 11 01843 g003
Figure 4. XRD patterns of PAN nanofibers, PS nanofibers, and PAN/PS composite nanofibers.
Figure 4. XRD patterns of PAN nanofibers, PS nanofibers, and PAN/PS composite nanofibers.
Foods 11 01843 g004
Figure 5. (a) Adsorption efficiency of nine quinolones onto PAN and PAN-PS nanofiber extraction columns; (be) effects of methanol concentration in the eluent, sulfuric acid concentration in the eluent, the amount of nanofibers, and salt concentration on the extraction efficiency at a concentration of 50 ng/mL for nine quinolones; (f) effect of the run number for reproducibility on extraction efficiency at the concentration of 50 ng/mL for nine quinolones.
Figure 5. (a) Adsorption efficiency of nine quinolones onto PAN and PAN-PS nanofiber extraction columns; (be) effects of methanol concentration in the eluent, sulfuric acid concentration in the eluent, the amount of nanofibers, and salt concentration on the extraction efficiency at a concentration of 50 ng/mL for nine quinolones; (f) effect of the run number for reproducibility on extraction efficiency at the concentration of 50 ng/mL for nine quinolones.
Foods 11 01843 g005
Figure 6. MS/MS spectra of all analytes in a spiked pure milk sample (spike concentration: 5.0 ng/mL). * Precursor ion, ** Product ions.
Figure 6. MS/MS spectra of all analytes in a spiked pure milk sample (spike concentration: 5.0 ng/mL). * Precursor ion, ** Product ions.
Foods 11 01843 g006
Table 1. Compound-dependent MS parameters for each analyte.
Table 1. Compound-dependent MS parameters for each analyte.
AnalyteStructureFormulaPrecursor ion
(m/z)
Product ions
(m/z)
Cone Voltage
(V)
Collision Energy
(V)
Enrofloxacin
(ENR)
Foods 11 01843 i001C19H22FN3O3360.0316.2 *12020
342.120
244.940
Ciprofloxacin
(CIP)
Foods 11 01843 i002C17H18FN3O3332.1314.1 *13520
231.042
Ofloxacin
(OFL)
Foods 11 01843 i003C18H20FN3O4362.0318.1 *13015
261.126
Pefloxacin
(PEF)
Foods 11 01843 i004C17H20FN3O3334.1290.2 *13016
316.220
Lomefloxacin
(LOM)
Foods 11 01843 i005C17H19F2N3O3352.1265.1 *13020
308.110
Norfloxacin
(NOR)
Foods 11 01843 i006C16H18FN3O3320.0276.1 *13015
302.120
Sarafloxacin
(SAR)
Foods 11 01843 i007C20H17F2N3O3386.1342.1 *13015
368.120
Danfloxacin
(DAN)
Foods 11 01843 i008C19H20FN3O3358.1340.1 *14025
255.046
Difloxacin
(DIF)
Foods 11 01843 i009C21H19F2N3O3400.0356.1 *14020
382.120
* Ions used for quantification.
Table 2. Performance of the method.
Table 2. Performance of the method.
AnalyteLinearity Range
(ng/mL)
Correlation Coefficient
(R2)
LOD
(ng/mL)
LOQ
(ng/mL)
ENR1.0–1000.99990.180.59
CIP0.99940.361.20
OFL0.99960.230.76
PEF0.99960.160.53
LOM0.99970.230.75
NOR0.99940.391.29
SAR0.99960.270.91
DAN0.99920.180.59
DIF0.99980.361.19
Table 3. Absolute recoveries of nine quinolones from pure milk samples via PFSPE−HPLC−MS/MS analysis.
Table 3. Absolute recoveries of nine quinolones from pure milk samples via PFSPE−HPLC−MS/MS analysis.
AnalyteSpiked Concentration
(ng/mL)
Recovery (%) ± RSD (n = 3)
Intra−DayInter−Day
ENR292.51 ± 1.7190.64 ± 5.02
1090.94 ± 2.6188.68 ± 3.10
2595.39 ± 4.4193.25 ± 4.67
CIP297.02 ± 1.5696.72 ± 3.92
1097.27 ± 5.3895.59 ± 6.07
2593.56 ± 2.6791.30 ± 4.16
OFL297.93 ± 2.7497.64 ± 3.15
1095.53 ± 3.1594.20 ± 2.61
2594.92 ± 2.2795.94 ± 2.01
PEF293.51 ± 1.6093.12 ± 3.34
1092.60 ± 1.0890.74 ± 1.10
2589.86 ± 1.5389.10 ± 3.50
LOM294.11 ± 2.3691.12 ± 5.01
1095.78 ± 1.6893.30 ± 4.22
2592.22 ± 2.4692.84 ± 2.96
NOR291.81 ± 1.2091.49 ± 2.30
1092.28 ± 2.6692.12 ± 3.94
2595.26 ± 1.2892.86 ± 2.41
SAR290.98 ± 2.3690.86 ± 2.06
1092.06 ± 3.7791.72 ± 2.37
2591.49 ± 2.5592.04 ± 2.93
DAN296.00 ± 2.6694.39 ± 4.29
1091.32 ± 1.2590.49 ± 3.06
2597.63 ± 2.4094.96 ± 3.09
DIF295.33 ± 2.0494.11 ± 4.35
1094.61 ± 3.0594.31 ± 2.72
2595.98 ± 4.9295.04 ± 5.58
Table 4. Evaluation of matrix effect with comparison of calibration-curve slopes.
Table 4. Evaluation of matrix effect with comparison of calibration-curve slopes.
AnalyteMatrixSlopeSlope Matrix/Solvent%ME
ENRWater2040.142390.982698.3%
Milk2004.60237
CIPWater1018.391310.966196.6%
Milk983.82133
OFLWater1586.971980.978297.8%
Milk1552.37639
PEFWater2363.712960.950295.0%
Milk2246.1182
LOMWater1654.794230.953295.3%
Milk1577.41885
NORWater934.710110.979397.9%
Milk915.32412
SARWater1347.29610.967196.7%
Milk1303.02713
DANWater2089.563140.952895.3%
Milk1991.0296
DIFWater1053.19160.941694.2%
Milk991.72708
Table 5. Comparison of the selected analytical parameters using the developed method and the reported analytical methods.
Table 5. Comparison of the selected analytical parameters using the developed method and the reported analytical methods.
Extraction MethodDetection
Method
TargetRecovery Rate
(%)
LODLOQLinearity RangeReferences
HLB-SPELC-MS/MS1479.0~119.90.5~1.5 μg/kg2.0~5.0 μg/kg2.5~100.0 μg/L[26]
IL-DLLME-MSPEHPLC381.2~109.01.5 μg/L4.0~8.0 μg/L4~1000 μg/L[27]
96-well-basedIFA190.0~100.04.0 μg/L/0.01~400 μg/L[28]
MSPEHPLC-DAD778.9~119.00.010~0.046 μg/kg/0.05~200.0 μg/kg[29]
MIP-SPEHPLC476.8~97.710.0~20.0 ng/mL20.0~50.0 ng/mL20~1000 ng/mL[30]
MNPLFIA1016.47~83.671.0~2.0 ng/mL/0.2~10 µg/m[31]
IA-MEPSHPLC853.9~90.60.05~0.1 ng/g0.15~0.3 ng/g0.1~100.0 µg/mL[32]
PFSPELC-MS/MS980.64~95.260.31~0.91 ng/mL1.03~3.03 ng/mL1.0~100.0 ng/mLThis study
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Wei, L.; Chen, Y.; Shao, D.; Li, J. Simultaneous Determination of Nine Quinolones in Pure Milk Using PFSPE-HPLC-MS/MS with PS-PAN Nanofibers as a Sorbent. Foods 2022, 11, 1843. https://0-doi-org.brum.beds.ac.uk/10.3390/foods11131843

AMA Style

Wei L, Chen Y, Shao D, Li J. Simultaneous Determination of Nine Quinolones in Pure Milk Using PFSPE-HPLC-MS/MS with PS-PAN Nanofibers as a Sorbent. Foods. 2022; 11(13):1843. https://0-doi-org.brum.beds.ac.uk/10.3390/foods11131843

Chicago/Turabian Style

Wei, Lanlan, Yanan Chen, Dongliang Shao, and Jingjun Li. 2022. "Simultaneous Determination of Nine Quinolones in Pure Milk Using PFSPE-HPLC-MS/MS with PS-PAN Nanofibers as a Sorbent" Foods 11, no. 13: 1843. https://0-doi-org.brum.beds.ac.uk/10.3390/foods11131843

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop