Next Article in Journal
Small Non-Coding RNAome of Ageing Chondrocytes
Previous Article in Journal
Changes in Novel AKI Biomarkers after Exercise. A Systematic Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Development and Evaluation of Novel and Highly Sensitive Single-Tube Nested Real-Time RT-PCR Assays for SARS-CoV-2 Detection

by
Cyril Chik-Yan Yip
1,†,
Siddharth Sridhar
2,3,4,†,
Kit-Hang Leung
2,
Anthony Chin-Ki Ng
2,
Kwok-Hung Chan
2,3,4,
Jasper Fuk-Woo Chan
2,3,4,
Owen Tak-Yin Tsang
5,
Ivan Fan-Ngai Hung
6,
Vincent Chi-Chung Cheng
1,
Kwok-Yung Yuen
1,2,3,4,* and
Kelvin Kai-Wang To
2,3,4,*
1
Department of Microbiology, Queen Mary Hospital, Hong Kong, China
2
Department of Microbiology, The University of Hong Kong, Hong Kong, China
3
State Key Laboratory of Emerging Infectious Diseases, The University of Hong Kong, Hong Kong, China
4
Carol Yu Centre for Infection, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
5
Department of Medicine and Geriatrics, Princess Margaret Hospital, Hong Kong, China
6
Department of Medicine, The University of Hong Kong, Hong Kong, China
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Int. J. Mol. Sci. 2020, 21(16), 5674; https://0-doi-org.brum.beds.ac.uk/10.3390/ijms21165674
Submission received: 30 June 2020 / Revised: 28 July 2020 / Accepted: 5 August 2020 / Published: 7 August 2020
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)

Abstract

:
Sensitive molecular assays are critical for coronavirus disease 2019 (COVID-19) diagnosis. Here, we designed and evaluated two single-tube nested (STN) real-time RT-PCR assays, targeting SARS-CoV-2 RdRp/Hel and N genes. Both STN assays had a low limit of detection and did not cross react with other human coronaviruses and respiratory viruses. Using 213 initial respiratory specimens from suspected COVID-19 patients, the sensitivity of both the STN COVID-19-RdRp/Hel and the STN COVID-19-N assays was 100% (99/99), while that of the comparator non-nested N assay was 95% (94/99). Among 108 follow-up specimens from confirmed COVID-19 patients who tested negative by the non-nested COVID-19-RdRp/Hel assay, 28 (25.9%) were positive for SARS-CoV-2 by the STN COVID-19-RdRp/Hel or the STN COVID-19-N assay. To evaluate the performance of our novel STN assays in pooled specimens, we created four sample pools, with each pool consisting of one low positive specimen and 49 negative specimens. While the non-nested COVID-19-RdRp/Hel assay was positive in only one of four sample pools (25%), both of the STN assays were positive in two of four samples pools (50%). In conclusion, the STN assays are highly sensitive and specific for SARS-CoV-2 detection. Their boosted sensitivity offers advantages in non-traditional COVID-19 testing algorithms such as saliva screening and pooled sample screening during massive screening.

1. Introduction

The global pandemic of coronavirus disease 2019 (COVID-19) is the greatest infectious disease challenge of the 21st century [1,2,3,4]. Various non-pharmaceutical public health interventions to reduce COVID-19 community transmission have been instituted worldwide [5,6,7]. Widespread deployment of accessible and accurate COVID-19 RT-PCR tests for individuals with mild symptoms in the community is an important way to reduce COVID-19 transmission. Confirmed cases of COVID-19 may then be isolated and their close contacts quarantined to dramatically reduce the effective reproduction number [8].
There is evidence to suggest that viral loads of SARS-CoV-2, the causative agent of COVID-19, are higher in lower respiratory tract specimens than upper respiratory tract specimens [9]. However, the usual specimen types obtained from patients with suspected COVID-19 are nasopharyngeal and oropharyngeal swabs [10,11]. Poor sampling techniques can further affect the accuracy of tests run on these specimens. These factors raise the possibility of “false-negative” results from upper respiratory tract specimens. One approach to overcome this shortcoming is to maximize the analytical sensitivity of the COVID-19 reverse transcription-polymerase chain reaction (RT-PCR) assay so as to be able to detect even minute levels of SARS-CoV-2 RNA in upper respiratory tract specimens.
Nested PCR assays utilize two sets of primers (external and internal) to maximize analytical sensitivity, but the major drawback of these assays is the need to transfer amplicons from the external primer reaction to a new tube for the internal primer reaction. Furthermore, traditional nested assays rely on end-point product detection in gels and so are not amenable to quantitation. Single-tube nested (STN) real-time RT-PCR assays overcome these limitations by manipulating annealing temperatures, thereby enabling reverse transcription, external primer amplification and internal primer amplification to take place sequentially in the same tube [12]. By incorporation of fluorescent probes, these assays are also compatible with commonly used real-time PCR thermocyclers enabling relative quantitation. Recently, Wang et al. has developed SARS-CoV-2 STN RT-PCR assays based on a commercial RT-PCR kit [13], but the primer and probe sequences used were not reported. In this study, we designed novel STN real-time RT-PCR assays capable of highly sensitive detection of SARS-CoV-2 in clinical specimens.

2. Results

2.1. In Silico Analysis of Primers and Probes Used in the In-House Developed STN Real-Time RT-PCR Assays for SARS-CoV-2 Detection

To assess whether the novel STN real-time RT-PCR assays can detect globally circulating SARS-CoV-2 isolates, the primer and probe sequences were aligned with viral gene sequences that are available in NCBI GenBank (Table S1). The primers and probes showed no mismatches with SARS-CoV-2 isolates from different geographical regions, except one noted at the 5′ end of the inner reverse primer of the COVID-19-RdRp/Hel assay (Figure S1). These primer/probe sets were predicted to specifically detect SARS-CoV-2 and had no major combined homologies with human, other respiratory viruses or microbial genes on BLASTn analysis that would potentially produce false-positive test results.

2.2. Analytical Performance of the STN RT-PCR Assays for SARS-CoV-2 Detection

To determine the analytical sensitivity of the STN RT-PCR assays, the limit of detection (LOD) was evaluated by using total nucleic acid (TNA) extracted from the SARS-CoV-2 isolate. Serial 10-fold dilutions of SARS-CoV-2 TNA extracted from the viral culture isolate were prepared and tested in triplicate for each concentration in two independent runs. The LOD of both the STN COVID-19-RdRp/Hel assay and the STN COVID-19-N assay was 1.8 × 10−1 TCID50/mL (Table S2).
To determine the analytical specificity of the STN COVID-19-RdRp/Hel assay and the STN COVID-19-N real-time RT-PCR assays, we tested TNA extracted from a clinical respiratory specimen with human coronavirus HKU1 (HCoV-HKU1), and TNAs extracted from the 17 culture isolates of SARS-CoV, MERS-CoV, HCoV-OC43, HCoV-NL63, HCoV-229E, influenza A ((H1N1)pdm09 and H3N2) viruses, influenza B virus, influenza C virus, parainfluenza virus types 1–4, respiratory syncytial virus, human metapneumovirus, human rhinovirus and human adenovirus. None of the two STN assays cross reacted with other respiratory viruses, confirming that they were highly specific.

2.3. Diagnostic Performance of the STN RT-PCR Assays for SARS-CoV-2 Detection

To assess the diagnostic performance of the STN real-time RT-PCR assays in clinical specimens, a total of 213 initial respiratory specimens from suspected COVID-19 patients were subjected to SARS-CoV-2 detection by the in-house developed STN COVID-19-RdRp/Hel and STN COVID-19-N RT-PCR assays, the non-nested COVID-19-RdRp/Hel RT-PCR assay and the non-nested RT-PCR assay targeting the N gene designed by National Institute of Infectious Diseases (NIID), Japan. Among these 213 specimens, 99 were positive for SARS-CoV-2 by the two STN RT-PCR assays and the non-nested COVID-19-RdRp/Hel assay, while 94 were positive for SARS-CoV-2 by the Japanese NIID non-nested N assay (Table 1). For the five specimens that tested negative by the non-nested N assay but positive by the other three assays, the median Cp value of these specimens was 36.13 (range: 34.80–37.61) by the non-nested COVID-19-RdRp/Hel assay, which represented low viral load. Among the eight proficiency testing (PT) samples from Quality Control for Molecular Diagnostics (QCMD), the two STN RT-PCR assays gave 100% correct results. A good agreement between Cp values generated by the STN COVID-19-RdRp/Hel and STN COVID-19-N RT-PCR assays was shown by a strong correlation (Spearman’s ρ = 0.96; p < 0.0001) (Figure 1). The Cp values obtained from the two STN RT-PCR assays were also examined. The median Cp value of the STN COVID-19-RdRp/Hel RT-PCR assay (18.67, IQR 9.09–23.69) was significantly lower than that of the STN COVID-19-N RT-PCR assay (19.85, IQR 10.89–29.32) (p < 0.0001) (Figure 2).
To further determine the clinical utility of the STN RT-PCR assays, 91 follow-up respiratory specimens and 17 follow-up non-respiratory specimens from patients with laboratory-confirmed COVID-19, which tested negative for SARS-CoV-2 by the non-nested COVID-19-RdRp/Hel assay, were tested. These specimens were collected from the patients with COVID-19 between 2 and 42 days after onset of symptoms. Among the 91 respiratory specimens, 21 (23.1%) were positive by either the STN COVID-19-RdRp/Hel assay or the STN COVID-19-N assays, of which 9 (9.9%) were positive by both assays (Table S3). Among the 17 non-respiratory specimens, 7 (41.2%) were positive by either the STN COVID-19-RdRp/Hel assay or the STN COVID-19-N assays, of which 3 (17.6%) were positive by both assays (Table S3).
Simultaneously collected nasopharyngeal swab (NPS) and saliva specimens obtained from eight COVID-19 patients were available for testing. One saliva specimen (Patient H) tested negative by the non-nested COVID-19-RdRp/Hel assay was positive for SARS-CoV-2 by the two STN RT-PCR assays (Table S4).
To determine whether a positive sample with a low viral load (Cp > 31) spiked in a pool of 50 samples could be detected by the STN RT-PCR assays, 4 pooled samples (50 samples per pool) were tested (Table 2). Each pool consisted of one positive sample with high Cp values combined with 49 SARS-CoV-2-negative samples. When the Cp value of the positive sample was approximately 32, both the non-nested COVID-19-RdRp/Hel assay and the STN RT-PCR assays flagged the pool positive. However, when the positive sample had a Cp value of approximately 33, the two STN RT-PCR assays, but not the non-nested COVID-19-RdRp/Hel assay, detected SARS-CoV-2 RNA in the pool. For the pools containing a positive sample with Cp > 34, the non-nested and STN RT-PCR assays flagged the pools as negative.

3. Discussion

RT-PCR assays are the most widely performed diagnostic tests for COVID-19 (https://www.who.int/publications/m/item/molecular-assays-to-diagnose-covid-19-summary-table-of-available-protocols). Despite their reliability and impressive analytical sensitivity, their real-world diagnostic sensitivity is often limited by sampling from sites with lower viral loads or using incorrect collection techniques. In this study, we present a potential solution to this problem by maximizing the analytical sensitivity of the assay with a nested real-time RT-PCR approach. This design combines the convenience of real-time RT-PCR with the high specificity and sensitivity of nested PCR.
Our results in this study offer a proof of concept of this approach. The analytical sensitivity of the STN RT-PCR assays targeting the RNA-dependent RNA polymerase (RdRp)/Helicase (Hel) and nucleocapsid (N) genes was higher than that of their non-nested counterparts using the same inner primers. The LOD of the two STN assays was one log10 lower than that of the non-nested assays (1.8 TCID50/mL, which was determined in our previous study) [14]. The diagnostic sensitivity of the STN RT-PCR assays for initial clinical specimens from suspected COVID-19 patients was equivalent to the non-nested RdRp/Hel RT-PCR and superior to the Japanese NIID N gene RT-PCR assay. However, when we assessed follow-up specimens from COVID-19 patients containing declining viral loads, a clear pattern of the superior diagnostic sensitivity of the STN RT-PCR assays was observed. This suggests that the additional analytical sensitivity of these assays translated to higher diagnostic sensitivities when deployed in specimens with low viral load. The STN RT-PCR assays also enabled us to diagnose COVID-19 from posterior oropharyngeal saliva, which is much more economical and safe to collect compared to swab specimens [16,17].
Rapid deployment of COVID-19 testing has been one of the major hurdles to the pandemic response in countries around the world. The cost of testing is often prohibitive in resource-limited settings. Moreover, there is a possibility of the shortage of nucleic acid extraction kits due to the heavy demand on SARS-CoV-2 screening during the COVID-19 outbreaks. One of the proposed solutions has been to pool respiratory samples together for testing, followed by work up of individual samples only if the pool is positive [18]. Pooling samples reduces the analyte load and, therefore, using highly sensitive nested RT-PCR assays offers obvious advantages. In our study, we found that the two STN RT-PCR assays offered additional sensitivity over the non-nested assay when the Cp value of the positive sample in the pool was approximately 33. This finding was similar to a study showing that SARS-CoV-2 RNA could still be detected in the positive pools with the single samples having the threshold cycle value up to 34, in which each pool consisted of 30 samples [18].
To date, primers and probes used in different RT-PCR assays mainly target ORF1ab, S, E, N regions of SARS-CoV-2 [1,14,17,19,20,21,22,23,24]. Coronaviruses have a high frequency of mutations and recombination [25,26,27], which may result in mismatches with the currently used primers and probes. Based on the multiple sequence alignment we performed in this study, no mismatch was noted between the primers/probes we used in the present study and the corresponding gene regions of the SARS-CoV-2 isolates circulating globally, except one noted at the 5′ end of the inner reverse primer of the COVID-19-RdRp/Hel assay. The mismatch was intentionally made to achieve the optimal GC content and melting temperature of this primer. The position of this mismatch is unlikely to affect the sensitivity of the assay, as shown in our evaluation. However, as these assays involve an additional set of primers, regular in silico surveillance to monitor for escape variants is required.
There are several differences between our SARS-CoV-2 STN RT-PCR assays and those reported by Wang et al. [13]. First, unlike our assays, these assays required locked nucleic acids in their external primer design and their assays with internal primer sets were commercial ones, which would dramatically increase assay cost. Second, their assay also required a relatively large template volume of 20 µL, while we achieved equivalent sensitivity with a smaller template volume of 5 µL.
Although STN RT-PCR assays represent a significant improvement over traditional real-time RT-PCR assays, their high sensitivity could be a disadvantage. As infection control regulations in many countries require negative SARS-CoV-2 RT-PCR results prior to patient discharge, adopting highly sensitive RT-PCR assays would be a disadvantage due to their enhanced ability to detect non-viable viral RNA fragments. We believe their role is mainly in initial screening of clinical specimens or pooled screening, as discussed above.
A limitation of this study was that we did not perform cell culture for STN RT-PCR positive, non-nested RT-PCR-negative specimens to investigate the viability of the virus. It is also probable that the efficacy of nucleic acid extraction is a limiting factor to the diagnostic sensitivity of STN RT-PCR assays. Future studies should compare nested and non-nested RT-PCR assays using different extraction methods. The relative importance of different gene targets and the optimal target for STN RT-PCR assays also remains to be elucidated.
In conclusion, this study describes the design and evaluation of novel STN RT-PCR assays for COVID-19 diagnosis. These assays can be applied to non-traditional specimen types such as posterior throat saliva. They maximize the sensitivity of initial screening of clinical specimens from patients with suspected COVID-19.

4. Materials and Methods

4.1. Viruses, Clinical Specimens and Proficiency Testing Samples for Evaluation

SARS-CoV-2 HKU-001a (GenBank accession number MT230904) was isolated from the nasopharyngeal aspirate (NPA) of a patient with COVID-19 in Hong Kong [28]. A SARS-CoV-2 culture isolate stock (1.8 × 107 TCID50/mL) was prepared by one additional passage using VeroE6 cell lines [29,30]. For analytical sensitivity evaluation, 10-fold serial dilutions of TNA extracted from the SARS-CoV-2 culture isolate were used. For analytical specificity evaluation, TNA extracted from a clinical specimen positive for HCoV-HKU1 and 17 culture isolates of other human coronaviruses and respiratory viruses were used [19,20,31]. For diagnostic performance evaluation, 213 initial clinical specimens including NPA, NPS, throat swab or saliva collected from 213 hospitalized patients (male: female = 112: 101; median age: 48 years; range: 62 days–103 years) with suspected COVID-19 were included for SARS-CoV-2 detection. Some of these specimens were evaluated previously using our in-house RT-PCR assays for SARS-CoV-2 detection [21]. To further determine the clinical utility of our novel STN real-time RT-PCR assays, we included hospitalized patients with sequential respiratory and non-respiratory specimens sent for SARS-CoV-2 detection for whom the first specimen tested positive but subsequent specimens tested negative by our previously described validated COVID-19-RdRp/Hel real-time RT-PCR assay [14]. We also included patients who had discrepant COVID-19-RdRp/Hel RT-PCR assay results on NPS and saliva specimens collected on the same day. These specimens were evaluated by a point-of-care assay in our previous study [32]. Furthermore, we prepared four pooled samples, with each pool consisting of one SARS-CoV-2-positive specimen with low viral load and 49 SARS-CoV-2-negative specimens. These pooled samples were evaluated by the non-nested COVID-19-RdRp/Hel assay and the STN real-time RT-PCR assays. In addition to clinical specimens, eight PT samples from QCMD with various concentrations of SARS-CoV-2 or negative for SARS-CoV-2 were also evaluated. The present study has been approved by the Institutional Review Board of the University of Hong Kong/Hospital Authority Hong Kong West Cluster (UW 20–286).

4.2. Nucleic Acid Extraction

TNA extraction of clinical specimens, pooled samples, PT samples and virus culture isolates was performed on 250 μL of each sample using the NucliSENS easyMAG extraction system (bioMérieux, Marcy-l’Étoile, France), as we previously described [33]. The TNA extracts (each with 55 μL) were stored at −80 °C until use.

4.3. Primers and Probes

Primer (outer and inner) and probe sets targeting the RdRp/Hel and N gene regions of SARS-CoV-2 for in-house developed STN RT-PCR assays were designed and tested. Multiple sequence alignments using the primer/probe sequences and the gene sequences of global SARS-CoV-2 isolates downloaded from NCBI GenBank were performed using ClustalX 2.1 [34].

4.4. Real-Time RT-PCR Assays for SARS-CoV-2 RNA Detection

A non-nested COVID-19-RdRp/Hel real-time RT-PCR assay for SARS-CoV-2 RNA detection was performed using a QuantiNova Probe RT-PCR Kit (QIAGEN, Hilden, Germany), as we previously described [14]. Each 20 μL reaction mixture contained 10 μL of 2× QuantiNova Probe RT-PCR Master Mix, 0.2 μL of QN Probe RT-Mix, 1.6 μL of each 10 μM forward and reverse primer, 0.4 μL of 10 μM probe (Table 3), 1.2 μL of nuclease-free water and 5 μL of TNA. Amplification and detection were performed on a LightCycler 480 II Real-Time PCR System (Roche, Basel, Switzerland). Thermocycling conditions consisted of 10 min at 45 °C for reverse transcription, 5 min at 95 °C for PCR initial activation, and 45 cycles of 5 s at 95 °C and 30 s at 55 °C.
One of the in-house developed molecular assays listed on the World Health Organization (WHO) website (https://www.who.int/who-documents-detail/molecular-assays-to-diagnose-covid-19-summary-table-of-available-protocols) was also used for comparative evaluation in this study. The non-nested N assay was designed by NIID, Japan [15], and we used the same protocol listed on the WHO website (https://www.who.int/docs/default-source/coronaviruse/whoinhouseassays.pdf?sfvrsn=de3a76aa_2&download=true). Briefly, a one-step real-time RT-PCR was performed using QuantiTect Probe RT-PCR Kit (QIAGEN) on the LightCycler 96 real-time PCR system (Roche). Each 20 μL reaction mixture contained 10 μL of 2× Master Mix, 0.2 μL of RT mix, 1 μL of 10 μM forward primer, 1.4 μL of 10 μM reverse primer, 0.4 μL of 10 μM probe (Table 3), 2 μL of nuclease-free water and 5 μL of TNA. Thermocycling conditions consisted of 30 min at 50 °C and 15 min at 95 °C, followed by 40 cycles of 15 s at 95 °C and 1 min at 60 °C.
The STN real-time RT-PCR assays were performed using the QuantiNova Probe RT-PCR Kit (QIAGEN) on the LightCycler 480 II Real-Time PCR System (Roche). Each 20 μL reaction mixture contained 10 μL of 2× QuantiNova Probe RT-PCR Master Mix, 0.2 μL of QN Probe RT-Mix, 0.16 μL of each 10 μM outer forward and reverse primer, 1.6 μL of each 10 μM inner forward and reverse primer, 0.4 μL of 10 μM probe (Table 3), 0.88 μL of nuclease-free water and 5 μL of TNA as the template. Thermocycling conditions consisted of 10 min at 45 °C for reverse transcription, 5 min at 95 °C for PCR initial activation, followed by 20 cycles of 5 s at 95 °C and 30 s at 69 °C (for first-round amplification by external primers with higher melting temperature (Tm)), and then 40 cycles of 5 s at 95 °C and 30 s at 55 °C (for second-round amplification by inner primers with a lower Tm; with fluorescence signal detection) (Figure S2). Negative and positive controls were included in all runs to monitor assay performance. PCR data were analyzed by “Abs Quant/2nd Derivative Max” method using the LightCycler 480 II system, which generated a Cp value of 5 for the samples with a high viral load between 0 and 5 cycles under default settings.

4.5. Statistical Analysis

Kappa statistic was used to determine the agreement between an assay and the reference standard (results obtained from at least 3 of 4 assays). McNemar’s test was used to compare the performance of the assays with the reference standard. Spearman’s correlation was used to assess the relation between the Cp values of the two STN real-time RT-PCR assays. Cp values of the two STN real-time RT-PCR assays were compared using Wilcoxon signed-rank test (a Cp value of 36 was assigned to specimens that tested negative in the STN RT-PCR assays). p < 0.05 was considered statistically significant. All statistical analysis was performed using GraphPad PRISM 8 or SPSS 26.0.

Supplementary Materials

Author Contributions

Conceptualization, C.C.-Y.Y., S.S., K.-Y.Y. and K.K.-W.T.; Methodology, C.C.-Y.Y., S.S., K.-Y.Y. and K.K.-W.T.; Validation, C.C.-Y.Y., K.-H.L. and A.C.-K.N.; Formal Analysis, C.C.-Y.Y., S.S. and K.K.-W.T.; Investigation, C.C.-Y.Y., K.-H.C., J.F.-W.C. and V.C.-C.C.; Resources, O.T.-Y.T. and I.F.-N.H.; Writing—Original Draft Preparation, C.C.-Y.Y., S.S. and K.K.-W.T.; Writing—Review and Editing, K.-Y.Y.; Supervision, K.-Y.Y. and K.K.-W.T.; Funding Acquisition, K.-Y.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This study was partly supported by the donations of Richard Yu and Carol Yu, the Shaw Foundation Hong Kong, May Tam Mak Mei Yin, Michael Seak-Kan Tong, Respiratory Viral Research Foundation Limited, Hui Ming, Hui Hoy and Chow Sin Lan Charity Fund Limited, Chan Yin Chuen Memorial Charitable Foundation, Marina Man-Wai Lee, the Jessie & George Ho Charitable Foundation, Perfect Shape Medical Limited, and Kai Chong Tong; the Consultancy Service for Enhancing Laboratory Surveillance of Emerging Infectious Diseases and Research Capability on Antimicrobial Resistance for Department of Health of the Hong Kong Special Administrative Region Government and the Theme-Based Research Scheme (T11/707/15) of the Research Grants Council, Hong Kong Special Administrative Region.

Conflicts of Interest

S.S. has received speaker’s honoraria from Abbott Laboratories Limited. J.F.-W.C. has received travel grants from Pfizer Corporation Hong Kong and Astellas Pharma Hong Kong Corporation Limited, and was an invited speaker for Gilead Sciences Hong Kong Limited and Luminex Corporation. The other authors declare no conflict of interest. The funders had no role in the design of this study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

Abbreviations

BLASTnNucleotide Basic Local Alignment Search Tool
COVID-19Coronavirus disease 2019
HCoVHuman coronavirus
HelHelicase
LODLimit of detection
MERS-CoVMiddle East respiratory syndrome coronavirus
NNucleocapsid
NCBINational Center for Biotechnology Information, USA
NPANasopharyngeal aspirate
NPSNasopharyngeal swab
PTProficiency testing
QCMDQuality Control for Molecular Diagnostics
RdRpRNA-dependent RNA polymerase
RT-PCRReverse transcription-polymerase chain reaction
SARS-CoVSevere acute respiratory syndrome coronavirus
SARS-CoV-2Severe acute respiratory syndrome coronavirus 2
STNSingle-tube nested
TCID50Tissue culture infectious dose
TmMelting temperature
TNATotal nucleic acid
WHOWorld Health Organization

References

  1. Chan, J.F.; Yuan, S.; Kok, K.H.; To, K.K.; Chu, H.; Yang, J.; Xing, F.; Liu, J.; Yip, C.C.; Poon, R.W.; et al. A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: A study of a family cluster. Lancet 2020, 395, 514–523. [Google Scholar] [CrossRef] [Green Version]
  2. Lescure, F.X.; Bouadma, L.; Nguyen, D.; Parisey, M.; Wicky, P.H.; Behillil, S.; Gaymard, A.; Bouscambert-Duchamp, M.; Donati, F.; Le Hingrat, Q.; et al. Clinical and virological data of the first cases of COVID-19 in Europe: A case series. Lancet Infect. Dis. 2020, 20, 697–706. [Google Scholar] [CrossRef] [Green Version]
  3. Lewnard, J.A.; Liu, V.X.; Jackson, M.L.; Schmidt, M.A.; Jewell, B.L.; Flores, J.P.; Jentz, C.; Northrup, G.R.; Mahmud, A.; Reingold, A.L.; et al. Incidence, clinical outcomes, and transmission dynamics of severe coronavirus disease 2019 in California and Washington: Prospective cohort study. BMJ 2020, 369, m1923. [Google Scholar] [CrossRef]
  4. Zhu, N.; Zhang, D.; Wang, W.; Li, X.; Yang, B.; Song, J.; Zhao, X.; Huang, B.; Shi, W.; Lu, R.; et al. A Novel Coronavirus from Patients with Pneumonia in China, 2019. N. Engl. J. Med. 2020, 382, 727–733. [Google Scholar] [CrossRef] [PubMed]
  5. Cheng, V.C.; Wong, S.C.; Chuang, V.W.; So, S.Y.; Chen, J.H.; Sridhar, S.; To, K.K.; Chan, J.F.; Hung, I.F.; Ho, P.L.; et al. The role of community-wide wearing of face mask for control of coronavirus disease 2019 (COVID-19) epidemic due to SARS-CoV-2. J. Infect. 2020. [Google Scholar] [CrossRef]
  6. Chu, D.K.; Akl, E.A.; Duda, S.; Solo, K.; Yaacoub, S.; Schünemann, H.J. COVID-19 Systematic Urgent Review Group Effort (SURGE) study authors. Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: A systematic review and meta-analysis. Lancet 2020. [Google Scholar] [CrossRef]
  7. MacIntyre, C.R.; Wang, Q. Physical distancing, face masks, and eye protection for prevention of COVID-19. Lancet 2020. [Google Scholar] [CrossRef]
  8. Cheng, V.C.; Wong, S.C.; Chen, J.H.; Yip, C.C.; Chuang, V.W.; Tsang, O.T.; Sridhar, S.; Chan, J.F.; Ho, P.L.; Yuen, K.Y. Escalating infection control response to the rapidly evolving epidemiology of the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2 in Hong Kong. Infect. Control Hosp. Epidemiol. 2020, 41, 493–498. [Google Scholar] [CrossRef] [Green Version]
  9. Yu, F.; Yan, L.; Wang, N.; Yang, S.; Wang, L.; Tang, Y.; Gao, G.; Wang, S.; Ma, C.; Xie, R.; et al. Quantitative Detection and Viral Load Analysis of SARS-CoV-2 in Infected Patients. Clin. Infect. Dis. 2020. [Google Scholar] [CrossRef] [Green Version]
  10. LeBlanc, J.J.; Heinstein, C.; MacDonald, J.; Pettipas, J.; Hatchette, T.F.; Patriquin, G. A combined oropharyngeal/nares swab is a suitable alternative to nasopharyngeal swabs for the detection of SARS-CoV-2. J. Clin. Virol. 2020, 128, 104442. [Google Scholar] [CrossRef]
  11. Wang, X.; Tan, L.; Wang, X.; Liu, W.; Lu, Y.; Cheng, L.; Sun, Z. Comparison of nasopharyngeal and oropharyngeal swabs for SARS-CoV-2 detection in 353 patients received tests with both specimens simultaneously. Int. J. Infect. Dis. 2020, 94, 107–109. [Google Scholar] [CrossRef] [PubMed]
  12. Yuen, K.Y.; Yam, W.C.; Wong, L.P.; Seto, W.H. Comparison of two automated DNA amplification systems with a manual one-tube nested PCR assay for diagnosis of pulmonary tuberculosis. J. Clin. Microbiol. 1997, 35, 1385–1389. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Wang, J.; Cai, K.; Zhang, R.; He, X.; Shen, X.; Liu, J.; Xu, J.; Qiu, F.; Lei, W.; Wang, J.; et al. A novel one-step single-tube nested quantitative Real-Time PCR assay for highly sensitive detection of SARS-CoV-2. Anal. Chem. 2020. [Google Scholar] [CrossRef] [PubMed]
  14. Chan, J.F.; Yip, C.C.; To, K.K.; Tang, T.H.; Wong, S.C.; Leung, K.H.; Fung, A.Y.; Ng, A.C.; Zou, Z.; Tsoi, H.W.; et al. Improved Molecular Diagnosis of COVID-19 by the Novel, Highly Sensitive and Specific COVID-19-RdRp/Hel Real-Time Reverse Transcription-PCR Assay Validated In Vitro and with Clinical Specimens. J. Clin. Microbiol. 2020, 58, e00310-20. [Google Scholar] [CrossRef] [Green Version]
  15. Shirato, K.; Nao, N.; Katano, H.; Takayama, I.; Saito, S.; Kato, F.; Katoh, H.; Sakata, M.; Nakatsu, Y.; Mori, Y.; et al. Development of Genetic Diagnostic Methods for Novel Coronavirus 2019 (nCoV-2019) in Japan. Jpn. J. Infect. Dis. 2020. [Google Scholar] [CrossRef] [Green Version]
  16. To, K.K.; Tsang, O.T.; Leung, W.S.; Tam, A.R.; Wu, T.C.; Lung, D.C.; Yip, C.C.; Cai, J.P.; Chan, J.M.; Chik, T.S.; et al. Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: An observational cohort study. Lancet Infect. Dis. 2020, 20, 565–574. [Google Scholar] [CrossRef] [Green Version]
  17. To, K.K.; Tsang, O.T.; Yip, C.C.; Chan, K.H.; Wu, T.C.; Chan, J.M.; Leung, W.S.; Chik, T.S.; Choi, C.Y.; Kandamby, D.H.; et al. Consistent detection of 2019 novel coronavirus in saliva. Clin. Infect. Dis. 2020. [Google Scholar] [CrossRef] [Green Version]
  18. Lohse, S.; Pfuhl, T.; Berkó-Göttel, B.; Rissland, J.; Geißler, T.; Gärtner, B.; Becker, S.L.; Schneitler, S.; Smola, S. Pooling of samples for testing for SARS-CoV-2 in asymptomatic people. Lancet Infect. Dis. 2020. [Google Scholar] [CrossRef]
  19. Chan, W.M.; Ip, J.D.; Chu, A.W.; Yip, C.C.; Lo, L.S.; Chan, K.H.; Ng, A.C.; Poon, R.W.; To, W.K.; Tsang, O.T.; et al. Identification of nsp1 gene as the target of SARS-CoV-2 real-time RT-PCR using nanopore whole genome sequencing. J. Med. Virol. 2020. [Google Scholar] [CrossRef]
  20. Yip, C.C.; Ho, C.C.; Chan, J.F.; To, K.K.; Chan, H.S.; Wong, S.C.; Leung, K.H.; Fung, A.Y.; Ng, A.C.; Zou, Z.; et al. Development of a Novel, Genome Subtraction-Derived, SARS-CoV-2-Specific COVID-19-nsp2 Real-Time RT-PCR Assay and Its Evaluation Using Clinical Specimens. Int. J. Mol. Sci. 2020, 21, 2574. [Google Scholar] [CrossRef] [Green Version]
  21. Yip, C.C.; Sridhar, S.; Cheng, A.K.; Leung, K.H.; Choi, G.K.; Chen, J.H.; Poon, R.W.; Chan, K.H.; Wu, A.K.; Chan, H.S.; et al. Evaluation of the commercially available LightMix® Modular E-gene kit using clinical and proficiency testing specimens for SARS-CoV-2 detection. J. Clin. Virol. 2020, 129, 104476. [Google Scholar] [CrossRef] [PubMed]
  22. Chu, D.K.W.; Pan, Y.; Cheng, S.M.S.; Hui, K.P.Y.; Krishnan, P.; Liu, Y.; Ng, D.Y.M.; Wan, C.K.C.; Yang, P.; Wang, Q.; et al. Molecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia. Clin. Chem. 2020, 66, 549–555. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Corman, V.M.; Landt, O.; Kaiser, M.; Molenkamp, R.; Meijer, A.; Chu, D.K.; Bleicker, T.; Brünink, S.; Schneider, J.; Schmidt, M.L.; et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Eurosurveillance 2020, 25, 2000045. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Hung, I.F.; Cheng, V.C.; Li, X.; Tam, A.R.; Hung, D.L.; Chiu, K.H.; Yip, C.C.; Cai, J.P.; Ho, D.T.; Wong, S.C.; et al. SARS-CoV-2 shedding and seroconversion among passengers quarantined after disembarking a cruise ship: A case series. Lancet Infect. Dis. 2020. [Google Scholar] [CrossRef]
  25. Baric, R.S.; Fu, K.; Chen, W.; Yount, B. High recombination and mutation rates in mouse hepatitis virus suggest that coronaviruses may be potentially important emerging viruses. Adv. Exp. Med. Biol. 1995, 380, 571–576. [Google Scholar]
  26. Lau, S.K.; Li, K.S.; Huang, Y.; Shek, C.T.; Tse, H.; Wang, M.; Choi, G.K.; Xu, H.; Lam, C.S.; Guo, R.; et al. Ecoepidemiology and comp lete genome comparison of different strains of severe acute respiratory syndrome-related Rhinolophus bat coronavirus in China reveal bats as a reservoir for acute, self-limiting infection that allows recombination events. J. Virol. 2010, 84, 2808–2819. [Google Scholar] [CrossRef] [Green Version]
  27. Woo, P.C.; Lau, S.K.; Yip, C.C.; Huang, Y.; Tsoi, H.W.; Chan, K.H.; Yuen, K.Y. Comparative analysis of 22 coronavirus HKU1 genomes reveals a novel genotype and evidence of natural recombination in coronavirus HKU1. J. Virol. 2006, 80, 7136–7145. [Google Scholar] [CrossRef] [Green Version]
  28. Chu, H.; Chan, J.F.; Yuen, T.T.; Shuai, H.; Yuan, S.; Wang, Y.; Hu, B.; Yip, C.C.; Tsang, J.O.; Huang, X.; et al. Comparative tropism, replication kinetics, and cell damage profiling of SARS-CoV-2 and SARS-CoV: Implications for clinical manifestations, transmissibility, and laboratory studies of COVID-19: An observational study. Lancet Microbe 2020, 1, e14–e23. [Google Scholar] [CrossRef]
  29. Chan, J.F.; Zhang, A.J.; Yuan, S.; Poon, V.K.; Chan, C.C.; Lee, A.C.; Chan, W.M.; Fan, Z.; Tsoi, H.W.; Wen, L.; et al. Simulation of the clinical and pathological manifestations of Coronavirus Disease 2019 (COVID-19) in golden Syrian hamster model: Implications for disease pathogenesis and transmissibility. Clin. Infect. Dis. 2020. [Google Scholar] [CrossRef] [Green Version]
  30. Chu, H.; Chan, J.F.; Wang, Y.; Yuen, T.T.; Chai, Y.; Hou, Y.; Shuai, H.; Yang, D.; Hu, B.; Huang, X.; et al. Comparative replication and immune activation profiles of SARS-CoV-2 and SARS-CoV in human lungs: An ex vivo study with implications for the pathogenesis of COVID-19. Clin. Infect. Dis. 2020. [Google Scholar] [CrossRef] [Green Version]
  31. Chan, J.F.; Choi, G.K.; Tsang, A.K.; Tee, K.M.; Lam, H.Y.; Yip, C.C.; To, K.K.; Cheng, V.C.; Yeung, M.L.; Lau, S.K.; et al. Development and Evaluation of Novel Real-Time Reverse Transcription-PCR Assays with Locked Nucleic Acid Probes Targeting Leader Sequences of Human-Pathogenic Coronaviruses. J. Clin. Microbiol. 2015, 53, 2722–2726. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Chen, J.H.; Yip, C.C.; Poon, R.W.; Chan, K.H.; Cheng, V.C.; Hung, I.F.; Chan, J.F.; Yuen, K.Y.; To, K.K. Evaluating the use of posterior oropharyngeal saliva in a point-of-care assay for the detection of SARS-CoV-2. Emerg. Microbes Infect. 2020, 9, 1356–1359. [Google Scholar] [CrossRef] [PubMed]
  33. Yip, C.C.; Chan, W.M.; Ip, J.D.; Seng, C.W.; Leung, K.H.; Poon, R.W.; Ng, A.C.; Wu, W.L.; Zhao, H.; Chan, K.H.; et al. Nanopore Sequencing Reveals Novel Targets for Detection and Surveillance of Human and Avian Influenza A Viruses. J. Clin. Microbiol. 2020, 58, e02127-19. [Google Scholar] [CrossRef] [PubMed]
  34. Larkin, M.A.; Blackshields, G.; Brown, N.P.; Chenna, R.; McGettigan, P.A.; McWilliam, H.; Valentin, F.; Wallace, I.M.; Wilm, A.; Lopez, R.; et al. Clustal W and Clustal X version 2.0. Bioinformatics 2007, 23, 2947–2948. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Correlation of the Cp values of the specimens found positive for SARS-CoV-2 by the STN COVID-19-RdRp/Hel assay and the STN COVID-19-N assay.
Figure 1. Correlation of the Cp values of the specimens found positive for SARS-CoV-2 by the STN COVID-19-RdRp/Hel assay and the STN COVID-19-N assay.
Ijms 21 05674 g001
Figure 2. Comparison of the Cp values of the two STN RT-PCR assays in this study. A Cp value of 36 was assigned to specimens that tested negative in the STN RT-PCR assays. **** indicates p < 0.0001.
Figure 2. Comparison of the Cp values of the two STN RT-PCR assays in this study. A Cp value of 36 was assigned to specimens that tested negative in the STN RT-PCR assays. **** indicates p < 0.0001.
Ijms 21 05674 g002
Table 1. Clinical performance comparison of the in-house developed STN real-time RT-PCR assays and other validated molecular assays for SARS-CoV-2 detection.
Table 1. Clinical performance comparison of the in-house developed STN real-time RT-PCR assays and other validated molecular assays for SARS-CoV-2 detection.
Molecular AssaysReference Standard *Kappa Value (95% CI) McNemar’s Test
PositiveNegative
STN COVID-19-RdRp/Hel assay
Positive9901.00 (1.00–1.00)p = 1.000
Negative0114
STN COVID-19-N assay
Positive9901.00 (1.00–1.00)p = 1.000
Negative0114
Non-nested COVID-19-RdRp/Hel assay [14]
Positive9901.00 (1.00–1.00)p = 1.000
Negative0114
Non-nested N assay [15]
Positive9400.95 (0.91–0.99)p = 0.063
Negative5114
* The reference standard was defined as the results obtained from at least three of the above assays. CI, confidence interval.
Table 2. Evaluation of four pooled samples using the in-house developed non-nested COVID-19-RdRp/Hel and STN real-time RT-PCR assays.
Table 2. Evaluation of four pooled samples using the in-house developed non-nested COVID-19-RdRp/Hel and STN real-time RT-PCR assays.
Cp Value
Pool *Single Test (Non-Nested COVID-19-RdRp/Hel Assay)Pool Test (Non-Nested COVID-19-RdRp/Hel AssayPool Test (STN COVID-19-RdRp/Hel Assay)Pool Test (STN COVID-19-N Assay)
132.2132.6221.0324.68
233.3123.2530.25
334.80
435.76
−, negative. * 50 samples per pool (each pool with one positive sample and 49 negative samples by the non-nested COVID-19-RdRp/Hel assay).
Table 3. Primers and probes used in this study.
Table 3. Primers and probes used in this study.
Primer/ProbeSequence (5′–3′)Gene TargetReference
In-house single-tube nested real-time RT-PCR
Outer forwardAGGTATTGGGAACCTGAGTTTTATGAGGCTATGTACACACRdRp/HelThis study
Outer reverseACCTGGAGCATTGCAAACATACGGATTAACAGACAAGAC
Inner forwardCGCATACAGTCTTRCAGGCT
Inner reverseGTGTGATGTTGAWATGACATGGTC
ProbeFAM- TTAAGATGTGGTGCTTGCATACGTAGAC -lABkFQ
Outer forwardAATTGCACAATTTGCCCCCAGCGCTTCANThis study
Outer reverseTGCGTCAATATGCTTATTCAGCAAAATGACTTGATCTTTGA
Inner forwardGCGTTCTTCGGAATGTCG
Inner reverseTTGGATCTTTGTCATCCAATTTG
ProbeFAM- AACGTGGTTGACCTACACAGST -lABkFQ
In-house non-nested real-time RT-PCR
COVID-19-RdRp/Hel-FCGCATACAGTCTTRCAGGCTRdRp/Hel[14]
COVID-19-RdRp/Hel-RGTGTGATGTTGAWATGACATGGTC
COVID-19-RdRp/Hel-PFAM- TTAAGATGTGGTGCTTGCATACGTAGAC -lABkFQ
NIID_2019-n
COV_N_F2
AAATTTTGGGGACCAGGAACN[15]
NIID_2019-n
COV_N_R2
TGGCAGCTGTGTAGGTCAAC
NIID_2019-n
COV_N_P2
FAM- ATGTCGCGCATTGGCATGGA -BHQ

Share and Cite

MDPI and ACS Style

Yip, C.C.-Y.; Sridhar, S.; Leung, K.-H.; Ng, A.C.-K.; Chan, K.-H.; Chan, J.F.-W.; Tsang, O.T.-Y.; Hung, I.F.-N.; Cheng, V.C.-C.; Yuen, K.-Y.; et al. Development and Evaluation of Novel and Highly Sensitive Single-Tube Nested Real-Time RT-PCR Assays for SARS-CoV-2 Detection. Int. J. Mol. Sci. 2020, 21, 5674. https://0-doi-org.brum.beds.ac.uk/10.3390/ijms21165674

AMA Style

Yip CC-Y, Sridhar S, Leung K-H, Ng AC-K, Chan K-H, Chan JF-W, Tsang OT-Y, Hung IF-N, Cheng VC-C, Yuen K-Y, et al. Development and Evaluation of Novel and Highly Sensitive Single-Tube Nested Real-Time RT-PCR Assays for SARS-CoV-2 Detection. International Journal of Molecular Sciences. 2020; 21(16):5674. https://0-doi-org.brum.beds.ac.uk/10.3390/ijms21165674

Chicago/Turabian Style

Yip, Cyril Chik-Yan, Siddharth Sridhar, Kit-Hang Leung, Anthony Chin-Ki Ng, Kwok-Hung Chan, Jasper Fuk-Woo Chan, Owen Tak-Yin Tsang, Ivan Fan-Ngai Hung, Vincent Chi-Chung Cheng, Kwok-Yung Yuen, and et al. 2020. "Development and Evaluation of Novel and Highly Sensitive Single-Tube Nested Real-Time RT-PCR Assays for SARS-CoV-2 Detection" International Journal of Molecular Sciences 21, no. 16: 5674. https://0-doi-org.brum.beds.ac.uk/10.3390/ijms21165674

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop