A Wireless Gas Sensor Network to Monitor Indoor Environmental Quality in Schools

1
Laboratory for Gas Sensors, Department of Microsystems Engineering, University of Freiburg, Georges-Köhler-Allee 102, 79110 Freiburg, Germany
2
Fraunhofer Institute for Physical Measurement Techniques (IPM), Heidenhofstraße 8, 79110 Freiburg, Germany
3
Department of Computer Science, Universidad Autónoma de Madrid, Francisco Tomás y Valiente 11, 28049 Madrid, Spain
*
Author to whom correspondence should be addressed.
Submission received: 6 November 2018 / Revised: 4 December 2018 / Accepted: 6 December 2018 / Published: 9 December 2018
(This article belongs to the Special Issue Wireless Sensor Network for Air Quality Monitoring and Control)

Abstract

:
Schools are amongst the most densely occupied indoor areas and at the same time children and young adults are the most vulnerable group with respect to adverse health effects as a result of poor environmental conditions. Health, performance and well-being of pupils crucially depend on indoor environmental quality (IEQ) of which air quality and thermal comfort are central pillars. This makes the monitoring and control of environmental parameters in classes important. At the same time most school buildings do neither feature automated, intelligent heating, ventilation, and air conditioning (HVAC) systems nor suitable IEQ monitoring systems. In this contribution, we therefore investigate the capabilities of a novel wireless gas sensor network to determine carbon dioxide concentrations, along with temperature and humidity. The use of a photoacoustic detector enables the construction of long-term stable, miniaturized, LED-based non-dispersive infrared absorption spectrometers without the use of a reference channel. The data of the sensor nodes is transmitted via a Z-Wave protocol to a central gateway, which in turn sends the data to a web-based platform for online analysis. The results show that it is difficult to maintain adequate IEQ levels in class rooms even when ventilating frequently and that individual monitoring and control of rooms is necessary to combine energy savings and good IEQ.

1. Introduction

The amount of time people spend indoors exceeds 90% of the total [1,2,3] and as a consequence indoor environment quality (IEQ) is a major concern for health and well-being of the general population. The concept of IEQ entails indoor air quality (IAQ), thermal comfort, as well as light and noise levels inside buildings [4]. Because of their increased vulnerability children and young adults are particularly prone to the adverse effects of poor IEQ and especially schools, which usually feature a high occupant density, are focal point of a multitude of challenges. These include the accumulation of hazardous gases and particulate matter (PM), health risks via mold formation as well as the spreading of bacteria [5]. Additionally, thermal comfort is closely linked with the cognitive performance [6] and hence both educational success and health of pupils in schools critically hinges on IEQ. Past research has established the negative health effects originating from exposure to nitrogen dioxide (NO2), ozone (O3), carbon dioxide (CO2), carbon monoxide (CO), volatile organic compounds (VOCs) and benzene, toluene, ethylbenzene, xylenes (BTEX) in particular, radon, and PM exposure and consequently the need to monitor and control their concentrations in schools [7,8,9], so while there is a need for large scale deployment of sensor technologies to enable monitoring IEQ with high temporal and spatial resolution in schools, currently available solutions are scarce and too costly for large area installations [5]. In particular, to date all wireless gas sensor networks face a trade-off between sensor node cost and data quality because currently no suitable, low-cost technology for specific, quantitative chemical analysis is available [10]. Researchers and companies alike therefore have to revert to technologies that approximate the gaseous pollutants content instead of specifically determining the quantity of trace gas concentrations. Commercial solutions that may serve as sensor nodes include individual sensors to monitor IAQ with varying combinations of sensors for gases and particulate matter. The main obstacle is the current lack in suitable chemical analysis technologies to specifically and sensitively determine the concentration of gaseous air pollutants at low-cost, and offering long term stable detection. Past studies therefore often had to rely on logging data with low spatial and temporal resolution of several minutes [11,12,13,14] preventing real-time assessment of IEQ and limiting large scale deployment of such systems. The underlying gas sensing technologies used are often low-cost but do not allow for specific detection of trace gases. E.g., the CO2 concentration is oftentimes inferred from the reading of a metal-oxide based, total volatile organic compound (TVOC) sensor, even though the correlation between TVOC and CO2 is weak [15]. While Raman-based approaches may detect many gases simultaneously [16,17,18,19,20,21,22], techniques based on absorption spectroscopy are the most promising candidates for reliable CO2 detection. Using tunable diode laser spectroscopy a high degree of sensitivity and specific, quantitative detection can be achieved, albeit at high associated costs in terms of optical and computational infrastructure as well as maintenance [23,24]. Currently, so-called non-dispersive infrared absorption spectroscopy (NDIR) is the most popular tool for CO2 monitoring that does not require analytical grade concentration readings [25]. Commercially available sensors achieve a resolution of ±30 ppm at an optical path length of several cm. Usually thermal emitters are used as light sources and spectral filters are employed to establish a reference channel that corrects for fluctuations of the emitted light intensity using the atmospheric window around 3.95 µm and a measurement channel to probe CO2 absorption bands at 2.6 µm or 4.2 µm [26,27]. The number of optical components necessary, the thermal emitter and the optical path lengths involved make for a rather bulky and comparatively expensive design. Recently, we have presented a design that builds on the original URAS idea [28], i.e., using the photoacoustic effect to gauge the light intensity of those parts of the light spectrum that are resonant to the CO2 absorption lines. This way LED-based gas sensors that are one order of magnitude smaller than current state-of-the art NDIR setups but comparable performance may be build [29,30]. While we have also presented a method to establish a reference channel to compensate drifts in the LED’s intensity in this setup [29], our laboratory characterization results suggest the possibility to compensate intensity fluctuations using a temperature calibration. This would open up the possibility to build the most basic form an NDIR sensor consisting only of a LED, a waveguide and a detector in a miniaturized form and featuring long-term stable operation. Other, more sophisticated, photoacoustic-based approaches allow e.g., for calibration-free monitoring or drift-reduction [31,32] but for all intends and purposes of IEQ monitoring, our simple setup suffices.
In this contribution, we therefore present results achieved by this basic setup that has been integrated into a wireless sensor network and enables the deployment of sensor nodes capable of monitoring thermal comfort as well as determining the CO2 concentrations specifically and within the required concentration range from 400–5000 ppm. Using our photoacoustic NDIR setup we show that long term stable operation of a LED-based CO2 sensor without reference channel is feasible by utilizing a suitable temperature compensation scheme. This opens up the possibility to produce low-power consuming, easy to manufacture CO2 gas sensors that do not feature cross-sensitivities towards humidity. Based on the data we investigate the effect of different ventilation methods on the air quality, discuss the implications on building-wide CO2 levels, and assess the thermal comfort. Because of the small size of the sensors nodes, their wireless internet connectivity and low-cost, the system architecture may easily be adapted to different scenarios and employed on a large scale. In particular, the approach enables in-situ monitoring with high spatial and temporal resolution inside a building and to combine the data to allow for a building performance evaluation and active control of IEQ.

2. Materials and Methods

Because of its outstanding importance for indoor air quality we demonstrate a gas sensor approach for CO2 employing a concept that may easily be adapted for further gases including NO2, CO, O3, and CO [33,34]. Evidence suggests correlations between absenteeism [11], bacterial infestation [35,36], and performance [37] with the CO2 levels indoors and it also allows for determining the ventilation rate. This makes the CO2 concentration the single most important chemical parameter to assess indoor air quality. In order to enable large scale deployment of the system at low cost and small overall size, we make use of a novel, miniature photoacoustic-based, nondispersive infrared (NDIR) setup, based on the original URAS design [28], which makes it possible to construct miniature CO2 sensors with high sensitivity and without cross-sensitivities towards humidity [30]. The CO2 sensor module features a mid-infrared LED from Hamamatsu (Hamamatsu City, Japan) as light source emitting light around 4.2 µm, an aluminum waveguide realizing an optical path of 30 mm and guiding the LED radiation to a hermetically sealed, CO2 filled cell containing a SPU0409HD5H-QB MEMS microphone from Knowles (Itasca, IL, USA). To excite a sound wave inside the detector, the LED is intensity modulated at 500 Hz using a rectangular current shape with 80 mA amplitude and 50% duty cycle. Since the sound wave amplitude is directly proportional to the light intensity [38], we use its magnitude to infer the CO2 concentration. To do this the microphone signal is first converted into a digital signal using an analog-to-digital converter (ADC) from Analog Devices (Norwood, MA, USA) with 12-bit and digital I2C interface protocol operating at 2.5k samples read out rate. The sound wave amplitude is determined using the Goertzel algorithm [39] implemented on the PSoC microcontroller. Using an apparatus to simulate real-world conditions in the lab [40], we have performed a calibration of the CO2 sensor reading in dry synthetic air at 1 bar pressure. We have also checked for cross-sensitivities towards humidity as well as established the correlation between ambient temperature and sensor signal [30]. To perform temperature calibration with large temperature variations we have used a climatic chamber filled with pure dry synthetic air in the temperature range from 15 °C to 50 °C. The latter calibration is then used to correct for the influence of temperature variations during field tests. To determine ambient temperature and humidity a fully calibrated SHT21 IC sensor with low power consumption from Sensirion (Staefa, Switzerland) is connected to the microcontroller using the I2C bus. The PSoC also acts as central tool to control data transmission via a Z-Wave module, sensing data on temperature, humidity, and CO2 concentration is send every 30 s.
The sensor node design is depicted in Figure 1 and includes wireless connectivity to make it possible to monitor the pollutant exposure of children on a micro-scale, which is needed for next generation studies of the health effects of school children [41]. At the same time the data from the whole network may be fused to offer a comprehensive picture on a building-wide level. Each node is equipped with a Z-Wave module to enable transfer of the data to an internet application by means of an internet gateway. In undisturbed environments the physical range of the transmission is about 100 m. Based on the online data platform “EnControl” from Sensing and Control Systems S.L. (Barcelona, Spain) we have created a tool to determine the thermal comfort, ventilation rate, and production rate of CO2 during classes. Moreover, data on thermal comfort may be used and integrated into the heating systems in order to minimize energy expenditure during winter. Using this system we investigate the result of various ventilation methods in a school as well as infer on the development of CO2 levels in the building as a The system has been deployed at “Gymnasium Remchingen”, a secondary school in rural Germany close to the city of Karlsruhe and the location of all sensor network components is depicted in Figure 2. The building is in operation since 2004 and currently about 470 pupils are educated in 21 classes. The building features a high level of thermal insulation and interior walls made of reinforced concrete but without active ventilation control, such that ventilation is controlled manually via opening the windows and/or class room doors. For investigating the influence of ventilation on indoor environmental quality a total of 5 rooms has been monitored each equipped with one sensor node. Because of the materials deployed in the school building the Z-Wave physical range is reduced to about 20 m, which is why a total of 3 repeaters modules has been installed for reliable signal transmission. Three of the rooms are standard class rooms and two are dedicated to physics classes.
Each sensor module sent the current CO2-level, humidity as well as temperature to the cloud-based “EnControl” platform every 30 s. Outdoor conditions are monitored via two weather stations in close proximity to the school (<200 m distance) whose data is available online through the Weather Underground web portal www.wunderground.com (The Weather Company, an IBM Business). These weather stations are based on NETATMO products (www.netatmo.com).
In order to assess the air quality in the five class rooms we use the CO2 concentration as tracer gas. We use these values to calculate the ventilation rates (VR) as well as the background levels in each room. Among the diverse methods to calculate the air change rate (ACR) we have chosen the decay method according to VDI 4300 (2001) [42], which has been proved to be a feasible and effective way to determine the air change rates in scenarios like the ones explored in this work [43]. The CO2 concentration upon venting using outdoor air should converge to the global background concentration, which we assume to be 400 ppm. However, because ventilation may also be done against the air inside the school building we use the guidelines from Laussmann & Helm [43] and use the equation they derived for the temporal evolution of the CO2 concentration to determine the effective background concentration Ca and the air change rate λ using a fit function of the form:
C ( t ) = ( C 0 C a ) · e λ · t + C a ,
where C0 is the initial concentration upon start of the ventilation at t = 0 s. A nonlinear regression is applied to the measured raw data acquired in order to determine the background concentration. Based on the calculated air change rate λ we calculate the ventilation rate VR in L/s according to:
V R =   λ · V · 1 3.6 ,
where V is the room volume in m³. The generation rate V CO 2 of CO2 inside rooms by occupants during class is calculated according to the model by Persily and de Jonge [44]:
V CO 2 = R Q · B M R · M · ( T / P ) · 0.000211 ,
which takes into account the respiratory quotient ( R Q = 0.85 set as value here), the basal metabolic rate B M R   in   M J d a y , the metabolic equivalent M , temperature T in K and Pressure P in kPa. With a known occupancy of each class the value of V CO 2 may be used to determine the physical activity of pupils, or vice versa. Apart from the CO2 concentration the thermal comfort is an important factor influencing the performance at school. Oftentimes, the temperature is used as the only parameter to assess the thermal comfort. However, humidity levels also significantly affect the thermal comfort. Although there are indications that children might experience thermal comfort differently than adults [45] we use the established ASHRAE Standard 55 to define thermal comfort [46] for people wearing winter clothing. Further large-scale measurement in various schools would be necessary to establish a reliable and more precise thermal comfort model for school children. For now we refer on ASHRAE 55, where good thermal comfort is achieved when temperatures are between 20 °C and 23 °C, and at the same time the relative humidity values are between 40 and 60% as described in [46]. Temperatures lower than 18 °C or higher than 25 °C as well as humidity levels below 20% or above 70% trigger a poor thermal comfort rating according to [47]. Intermediate values of temperature and humidity indicate mediocre but acceptable thermal comfort ratings. It should be taken into account that the thermal comfort evaluation has been made for the specific climatic locations in central Europe. In this case for the winter season and with a presumption of a typical winter indoor clothing level factor is set to 1.1 clo. This comfort function is easily adaptable to different climatic zones, clothing level and seasons of the year. In order to assign an overall indoor environmental quality score we include the CO2 concentration. We use the classification from [48] to evaluate the CO2 concentration levels: Levels below 1000 ppm indicate good air quality, values between 1000 and 2000 ppm medium quality, and values exceeding 2000 ppm poor air quality. Hence good indoor environmental quality requires both the thermal comfort as well as the air quality to be good and we assign three levels of IEQ to each room and at every time, which is indicated with green, yellow, and red shading in the graphs in line with previous research results [49,50].

3. Results and Discussion

The raw data of the temperature calibration and the gas sensitive characterization of the CO2 module are shown in Figure 3. The photoacoustic amplitude excited by the LED in the absence of CO2 decreases with increasing temperature, mainly because the optical output the MID-IR decreases [29]. Increasing the temperature of the CO2 sensor module from 17 °C to 47 °C leads to a decrease in emitted power of approximately 32%. A parabolic regression for the sensor signal S of the form:
S ( T ) =   i = 0 2 α i T i ,
with T the temperature in °C and α i the regression parameters is applied to describe the dependence of the detector signal on the temperature. This function is achieved under normal operating conditions and takes into account self-heating of the LED at a duty cycle of 50% and the stated driving current of 80 mA. Changes in duty cycle or driving current would alter this function since this would impact on the LED emission. The inset of Figure 3a shows the results obtained with optimized values obtained via a Levenberg Marquart fit for which the α i values read α 0 = (1.07354 ± 0.01024), α 1 = (−31.1 ± 7.5083) × 10−4 °C−1, and α 2 = (−8.36047 × 10−5 ± 1.25458) × 10−5 °C−2, respectively.
After implementing this temperature correction a CO2 calibration is performed by determining the sensor response for different CO2 concentrations. Figure 3b shows the transient response of the gas sensor upon exposure of 9 different concentrations of CO2 in the range from 300–700 ppm in steps of 50 ppm. The inset shows the corresponding calibration curve that takes into account concentration values up to 5000 ppm. Using a cubic regression curve for the response R = S( c CO 2 = 0 ppm)/S( c CO 2 ) of the form:
R ( c CO 2 ) = i = 0 3 β i   c CO 2 i ,
with c CO 2 the CO2 concentration in ppm and β i the regression parameters yields: β 0 = 0.99742 ± 0.00197; β 1 = (−81.8975 ± 4.4699) × 10−6 ppm−1; β 2 = (9.50238 ± 1.92614) × 10−9 ppm−2; β 3 = (−6.38218 ± 2.26994) × 10−13 ppm³. Characterization of the sensor type presented in previous work has showed no cross-sensitivities to humidity [30] and a detection range between 0–7000 ppm CO2 at 1 bar pressure [51] with operating temperatures between 15 °C and 50 °C (c.f. Figure 3). The operating principle prevents cross-sensitivities to gases that to not have absorption features that overlap with those of CO2. The lifespan of this type of sensor is determined by the lifetime of the LED light source, which we estimate to be at least 2 years, based on experimental data obtained previously [29]. The signal-to-noise ratio will worsen proportionally to the diminishing LED optical output [30] and hence the precision of the CO2 sensing module is affected accordingly. To counter this type of long-term effects a self-calibration routine may be implemented in the network by using prolonged periods without use of the school building, i.e., holidays, to automatically re-set the 400 ppm reading.
After calibration all CO2 sensor modules and establishing the system at Remchingen school basic functions of the system such as ventilation rate and CO2 generation rate determination have been checked. Exemplary results for room R2.21 are shown in Figure 4 to highlight the procedure to determine λ and Ca as well as the total CO2 generation rate.
The five rooms have been continuously monitored from 19 February 2018 until 10 April 2018. In Figure 5 we show the evolution of the thermal comfort during an exemplary day at the school in a class room with north orientation.
In this particular school, the heating system automatically starts to work at 5 am without active control with the intention to provide comfortable thermal conditions by 8 am. However, due to varying outdoor conditions this usually leads to an overheating early in the day. More precisely, on all days of the study the average room temperature during the morning has exceeded 23 °C, which is why a good thermal comfort range is only achieved in the early hours of each day. Additional heat generated by the class then quickly led to mediocre thermal comfort levels. While thermal comfort depends to a large extend on the subjective preference [6] and may still be judged acceptable by the pupils during most of the time the results show that an active thermal control taking into account outdoor temperature may lead to considerable cost savings via tailored heating. Moreover, the analysis of the data taking into account the orientation of each room shows that individual control of the thermal parameters taking into account radiative heating via sunshine is necessary to achieve good thermal comfort.
The temperature data of the classroom summarizing the complete monitoring period is depicted in Figure 5b, where the average indoor temperature is plotted versus the average outside temperature on the particular day. The correlation between average outdoor temperature and average indoor temperature is more than three times stronger when comparing class rooms facing north with those facing south. A linear fit to the complete data set reveals a slope of sS = (90 ± 40) mK/K for a room facing south and sN = (28 ± 8) mK/K facing north. These results underline the necessity to individually monitor and control each room in a building according to its peculiarities.
Adding the information about the CO2 levels allows for a more comprehensive IEQ assessment and a transient, exemplary week is shown in Figure 6, using a color scheme to indicate overall IEQ.
Even though room R2.17 is the biggest room in this study in terms of volume and area it exceeds the recommended value of 1000 ppm after only about 22 min on average even when starting from the 400 ppm level. Because of noise pollution windows have to remain shut during a class and combining this with the high building standard leads to medium or poor indoor air quality even in a comparatively large room. The evolution of the CO2 level as the most important indicator for health and concentration capabilities has consequently been analyzed in more detail. To this end we have determined the background levels during the week as well as the evolution of the CO2 level within each day. In Figure 7 we present raw data and the analysis of the background concentration in the class at 7.30 am, i.e., before teacher or pupils enter the room. The transient raw data for Monday shows that CO2 levels quickly increase from background level of about 400 ppm CO2 to about 2000 ppm within 90 min. Afterwards the room is ventilated for 15 min, which leads to a drop of about 1000 ppm. Consequently, during the next class the CO2 level inevitably rises to almost 3000 ppm. School on that day has finished shortly before 2 pm and the doors are shut afterwards. Because of the high level of thermal insulation, the natural ventilation rate of the building is low, which leads to a high level of CO2 remaining in the class the next day, when classes start at about 1000 ppm background level in the first class given that day. Notably, the ventilation behavior plays a crucial role in maintaining CO2 concentrations at a reasonable level. In this regard, it is not only important to manage one class room well but because CO2 accumulated in the building as a whole, holistic strategies for CO2 management of the complete building are necessary. Even though the importance of ventilation is known in this school, the background level in class rooms not only increases during each day but also during the week. The average CO2 level in room R2.17 at 7.30 am is plotted in Figure 7b and shows that it is rising throughout the week. Thursday is an exception because the room is not used at all on Wednesdays, which leads to a drop in early morning CO2 levels consistent with natural ventilation.
We have analyzed the different types of ventilation that are applied to the rooms and the ACR can be used to identify the type of action taken by the teacher and classify it. As expected the ACR greatly depends on opening the window and the air flow. The highest ACR results from opening several windows and doors simultaneously. This method is more than two orders of magnitude faster than the natural exchange of air of the room. Based on the results regarding the ventilation and CO2 background levels we have calculated which level of air change rate would be necessary to maintain CO2 levels consistent with good IAQ for ventilation times of 5 min, 15 min, 1 h, and 16 h respectively. The results are plotted in Figure 8 and show that natural ventilation of the building is insufficient to achieve good IAQ even after 16 h.
Even more attention-grabbing, the determined average natural ventilation rate of the building is below 0.1, which means that even a weekend is not long enough to recuperate background levels of 400 ppm CO2 if teachers fail to vent the room on Friday. This ultimately leads to an accumulation of CO2 during weeks and months, if no appropriate action is taken. Also a short 5 min break in between classes is insufficient to obtain good IAQ. Only a 15 min break and maximal ventilation would allow for good IAQ after a class. As a consequence even in schools with teachers that are highly aware of IEQ issues, such as at Remchingen Gymnasium, it is highly improbable that good IEQ can be achieved at all without the help of indoor air quality indicating systems.

4. Conclusions

High building standards and good thermal insulation have led to considerable saving in energy expenditure of buildings. Here we have shown that the strong suppression of the natural ventilation of buildings makes it very difficult to maintain good IAQ without active HVAC systems. CO2 not only accumulates during each school day but also during the course of the week leading to ever poorer IAQ. Only with ideal ventilation after each class is it possible to maintain good IAQ. At the same time schools are overheated to varying degrees depending on the orientation of the room. The results also show that it is important to monitor and control rooms individually to design mitigation strategies tailored to each room. This does not take away from the fact that a building wide strategy for IAQ control is necessary if good air quality is to be achieved. Because most schools are not equipped with active environmental control systems and thermal insulation is an important cornerstone for a sustainable energy landscape, the monitoring and implementation of intelligent ventilation strategies is much in need. In this regard, wireless sensor networks are a suitable technique to provide data on various temporal and spatial scales. The limiting factor is oftentimes the cost of each individual sensing node and here we have showed that low-cost, reliable, and selective gas sensing nodes are indeed feasible.

Author Contributions

Conceptualization, A.O.P. and S.P.; methodology, A.O.P. and S.P.; software, A.O.P., B.B. and L.S.; data curation, A.O.P.; writing—original draft preparation, A.O.P. and S.P.; writing—review and editing, J.W., B.B. and L.S.; supervision, S.P.; funding acquisition, S.P.

Funding

S.P. acknowledges funding from the Community of Madrid under grant number 2016-T1/AMB-1695.

Acknowledgments

The authors wish to sincerely thank Eva Müller and Knut Unbehaun from the Gymnasium Remchingen for their help and support during planning, installation and operation of the sensor network. The authors also appreciate the support of Sensing & Control Systems S.L.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Brasche, S.; Bischof, W. Daily time spent indoors in German homes—Baseline data for the assessment of indoor exposure of German occupants. Int. J. Hyg. Environ. Health 2005, 208, 247–253. [Google Scholar] [CrossRef] [PubMed]
  2. Leech, J.A.; Nelson, W.C.; Burnett, R.T.; Aaron, S.; Raizenne, M.E. It’s about time: A comparison of Canadian and American time-activity patterns. J. Expo. Anal. Environ. Epidemiol. 2002, 12, 427–432. [Google Scholar] [CrossRef] [PubMed]
  3. Schweizer, C.; Edwards, R.D.; Bayer-Oglesby, L.; Gauderman, W.J.; Ilacqua, V.; Juhani Jantunen, M.; Lai, H.K.; Nieuwenhuijsen, M.; Künzli, N. Indoor time-microenvironment-activity patterns in seven regions of Europe. J. Expo. Sci. Environ. Epidemiol. 2007, 17, 170–181. [Google Scholar] [CrossRef] [PubMed]
  4. Al Horr, Y.; Arif, M.; Katafygiotou, M.; Mazroei, A.; Kaushik, A.; Elsarrag, E. Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature. Int. J. Sustain. Built Environ. 2016, 5, 1–11. [Google Scholar] [CrossRef]
  5. Salthammer, T.; Uhde, E.; Schripp, T.; Schieweck, A.; Morawska, L.; Mazaheri, M.; Clifford, S.; He, C.; Buonanno, G.; Querol, X.; et al. Children’s well-being at schools: Impact of climatic conditions and air pollution. Environ. Int. 2016, 94, 196–210. [Google Scholar] [CrossRef] [PubMed]
  6. Corgnati, S.P.; Filippi, M.; Viazzo, S. Perception of the thermal environment in high school and university classrooms: Subjective preferences and thermal comfort. Build. Environ. 2007, 42, 951–959. [Google Scholar] [CrossRef]
  7. Chen, L.; Jennison, B.L.; Yang, W.; Omaye, S.T. Elementary School Absenteeism and Air Pollution. Inhal. Toxicol. 2000, 12, 997–1016. [Google Scholar] [CrossRef]
  8. Noy, D.; Brunekreef, B.; Boleij, S.M.J.; Houthuijs, D.; De Koning, R. The assessment of personal exposure to nitrogen dioxide in epidemiological studies. Atmos. Environ. Part A Gen. Top. 1990, 24, 2903–2909. [Google Scholar] [CrossRef]
  9. Evrard, A.S.; Hémon, D.; Billon, S.; Laurier, D.; Jougla, E.; Tirmarche, M.; Clavel, J. Childhood leukemia incidence and exposure to indoor radon, terrestrial and cosmic gamma radiation. Health Phys. 2006, 90, 569–579. [Google Scholar] [CrossRef]
  10. Yi, W.; Lo, K.; Mak, T.; Leung, K.; Leung, Y.; Meng, M. A Survey of Wireless Sensor Network Based Air Pollution Monitoring Systems. Sensors 2015, 15, 31392–31427. [Google Scholar] [CrossRef] [Green Version]
  11. Shendell, D.G.; Prill, R.; Fisk, W.J.; Apte, M.G.; Blake, D.; Faulkner, D. Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. Indoor Air 2004, 14, 333–341. [Google Scholar] [CrossRef]
  12. Batterman, S. Review and extension of CO2-based methods to determine ventilation rates with application to school classrooms. Int. J. Environ. Res. Public Health 2017, 14, 145. [Google Scholar] [CrossRef]
  13. Gaihre, S.; Semple, S.; Miller, J.; Fielding, S.; Turner, S. Classroom carbon dioxide concentration, school attendance, and educational attainment. J. Sch. Health 2014, 84, 569–574. [Google Scholar] [CrossRef] [PubMed]
  14. Muscatiello, N.; McCarthy, A.; Kielb, C.; Hsu, W.H.; Hwang, S.A.; Lin, S. Classroom conditions and CO2 concentrations and teacher health symptom reporting in 10 New York State Schools. Indoor Air 2015, 25, 157–167. [Google Scholar] [CrossRef] [PubMed]
  15. Chatzidiakou, L.; Mumovic, D.; Summerfield, A.J. What do we know about indoor air quality in school classrooms? A critical review of the literature. Intell. Build. Int. 2012, 4, 228–259. [Google Scholar] [CrossRef]
  16. Sandfort, V.; Trabold, B.; Abdolvand, A.; Bolwien, C.; Russell, P.; Wöllenstein, J.; Palzer, S. Monitoring the Wobbe Index of Natural Gas Using Fiber-Enhanced Raman Spectroscopy. Sensors 2017, 17, 2714. [Google Scholar] [CrossRef] [PubMed]
  17. Sandfort, V.; Goldschmidt, J.; Wöllenstein, J.; Palzer, S. Cavity-enhanced raman spectroscopy for food chain management. Sensors 2018, 18, 709. [Google Scholar] [CrossRef] [PubMed]
  18. Hanf, S.; Bögözi, T.; Keiner, R.; Frosch, T.; Popp, J. Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath. Anal. Chem. 2015, 87, 982–988. [Google Scholar] [CrossRef] [PubMed]
  19. Hanf, S.; Keiner, R.; Yan, D.; Popp, J.; Frosch, T. Fiber-Enhanced Raman Multigas Spectroscopy: A Versatile Tool for Environmental Gas Sensing and Breath Analysis. Anal. Chem. 2014, 86, 5278–5285. [Google Scholar] [CrossRef]
  20. Hill, R.A.; Mulac, A.J.; Hackett, C.E. Retroreflecting multipass cell for Raman scattering. Appl. Opt. 1977, 16, 2004–2006. [Google Scholar] [CrossRef]
  21. Hippler, M. Cavity-Enhanced Raman Spectroscopy of Natural Gas with Optical Feedback cw-Diode Lasers. Anal. Chem. 2015, 87, 7803–7809. [Google Scholar] [CrossRef] [PubMed]
  22. Friss, A.J.; Limbach, C.M.; Yalin, A.P. Cavity-enhanced rotational Raman scattering in gases using a 20 mW near-infrared fiber laser. Opt. Lett. 2016, 41, 3193. [Google Scholar] [CrossRef] [PubMed]
  23. Mantz, A.W. A Review of the Applications of Tunable Diode Laser Spectroscopy at High Sensitivity. Microchem. J. 1994, 50, 351–364. [Google Scholar] [CrossRef]
  24. Scholz, L.; Palzer, S. Photoacoustic-based detector for infrared laser spectroscopy. Appl. Phys. Lett. 2016, 109, 041102. [Google Scholar] [CrossRef]
  25. Dinh, T.V.; Choi, I.Y.; Son, Y.S.; Kim, J.C. A review on non-dispersive infrared gas sensors: Improvement of sensor detection limit and interference correction. Sens. Actuators B Chem. 2016, 231, 529–538. [Google Scholar] [CrossRef]
  26. Vincent, T.A.; Gardner, J.W. A low cost MEMS based NDIR system for the monitoring of carbon dioxide in breath analysis at ppm levels. Sens. Actuators B Chem. 2016, 236, 954–964. [Google Scholar] [CrossRef] [Green Version]
  27. Hodgkinson, J.; Smith, R.; Ho, W.O.; Saffell, J.R.; Tatam, R.P. Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor. Sens. Actuators B Chem. 2013, 186, 580–588. [Google Scholar] [CrossRef]
  28. Lehrer, G.; Luft, K. Verfahren zur Bestimmung von Bestandteilen in Stoffgemischen mittels Strahlungsabsorption. DE Patent DE730478C, 9 March 1938. [Google Scholar]
  29. Wittstock, V.; Scholz, L.; Bierer, B.; Perez, A.O.; Wöllenstein, J.; Palzer, S. Design of a LED-based sensor for monitoring the lower explosion limit of methane. Sens. Actuators B Chem. 2017. [Google Scholar] [CrossRef]
  30. Scholz, L.; Ortiz Perez, A.; Bierer, B.; Eaksen, P.; Wöllenstein, J.; Palzer, S. Miniature low-cost carbon dioxide sensor for mobile devices. IEEE Sens. J. 2017, 17. [Google Scholar] [CrossRef]
  31. Wu, H.; Dong, L.; Zheng, H.; Yu, Y.; Ma, W.; Zhang, L.; Yin, W.; Xiao, L.; Jia, S.; Tittel, F.K. Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring. Nat. Commun. 2017, 8, 1–8. [Google Scholar] [CrossRef]
  32. Rey, J.M.; Sigrist, M.W. New differential mode excitation photoacoustic scheme for near-infrared water vapour sensing. Sens. Actuators B Chem. 2008, 135, 161–165. [Google Scholar] [CrossRef]
  33. Knobelspies, S.; Bierer, B.; Ortiz Perez, A.; Wöllenstein, J.; Kneer, J.; Palzer, S. Low-cost gas sensing system for the reliable and precise measurement of methane, carbon dioxide and hydrogen sulfide in natural gas and biomethane. Sens. Actuators B Chem. 2016, 236, 885–892. [Google Scholar] [CrossRef]
  34. Bierer, B.; Nägele, H.-J.; Perez, A.O.; Wöllenstein, J.; Kress, P.; Lemmer, A.; Palzer, S. Real-Time Gas Quality Data for On-Demand Production of Biogas. Chem. Eng. Technol. 2018, 41. [Google Scholar] [CrossRef]
  35. Liu, L.J.S.; Krahmer, M.; Fox, A.; Feigley, C.E.; Featherstone, A.; Saraf, A.; Larsson, L. Investigation of the concentration of bacteria and their cell envelope components in indoor air in two elementary schools. J. Air Waste Manag. Assoc. 2000, 50, 1957–1967. [Google Scholar] [CrossRef] [PubMed]
  36. Fox, A.; Harley, W.; Feigley, C.; Salzberg, D.; Sebastian, A.; Larsson, L. Increased levels of bacterial markers and CO2 in occupied school rooms. J. Environ. Monit. 2003, 5, 246–252. [Google Scholar] [CrossRef] [PubMed]
  37. Wargocki, P.; Wyon, D.P.; Sundell, J.; Clausen, G.; Fanger, P.O. The Effects of Outdoor Air Supply Rate in an Office on Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity. Indoor Air 2000, 10, 222–236. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  38. Papadopoulos, G.J.; Mair, G.L.R. Amplitude and phase study of the photoacoustic effect. J. Phys. D Appl. Phys. 1992, 25, 722–726. [Google Scholar] [CrossRef]
  39. Goertzel, G. An Algorithm for the Evaluation of Finite Trigonometric Series. Am. Math. Mon. 1958, 65, 34. [Google Scholar] [CrossRef]
  40. Kneer, J.; Eberhardt, A.; Walden, P.; Ortiz Pérez, A.; Wöllenstein, J.; Palzer, S. Apparatus to characterize gas sensor response under real-world conditions in the lab. Rev. Sci. Instrum. 2014, 85. [Google Scholar] [CrossRef]
  41. Raysoni, A.U.; Stock, T.H.; Sarnat, J.A.; Montoya, T.; Ebelt, S.; Holguin, F.; Greenwald, R.; Johnson, B. Characterization of traf fi c-related air pollutant metrics at four schools in El Paso, Texas, USA: Implications for exposure assessment and siting schools in urban areas. Atmos. Environ. 2013, 80, 140–151. [Google Scholar] [CrossRef]
  42. VDI 4300 Blatt 7, Messen von Innenraumluftverunreinigungen—Bestimmung der Luftwechselzahl in Innenräumen; Beuth Verlag: Berlin, Germany, 2001.
  43. Laussmann, D.; Helm, D. Air Change Measurements Using Tracer Gases: Methods and Results. Significance of air change for indoor air quality. In Chemistry, Emissin Control, Radioactive Pollution and Indoor Air Quality; Mazzeo, N., Ed.; InTech: Rijeka, Croatia, 2011. [Google Scholar] [CrossRef] [Green Version]
  44. Persily, A.; de Jonge, L. Carbon dioxide generation rates for building occupants. Indoor Air 2017, 27, 868–879. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  45. Teli, D.; Jentsch, M.F.; James, P.A.B. Naturally ventilated classrooms: An assessment of existing comfort models for predicting the thermal sensation and preference of primary school children. Energy Build. 2012, 53, 166–182. [Google Scholar] [CrossRef]
  46. ASHRAE. Standard 55, Thermal Environmental Conditions for Human Occupancy; ASHRAE Inc.: Atlanta, GA, USA, 1992. [Google Scholar]
  47. ISO/TC 159/SC 5. ISO 7730:2005:—Ergonomics of the Thermal Environment—Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria; ISO: Geneva, Switzerland, 2005.
  48. Umweltbundesamt. Gesundheitliche Bewertung von Kohlendioxid in der Innenraumluft, Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 2008, 51, 1358–1369. [CrossRef]
  49. Wargocki, P.; Wyon, D.P. Providing better thermal and air quality conditions in school classrooms would be cost-effective. Build. Environ. 2013, 59, 581–589. [Google Scholar] [CrossRef]
  50. Mendell, M.J.; Heath, G.A. Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. Indoor Air 2005, 15, 27–52. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  51. Scholz, L.; Perez, A.O.; Bierer, B.; Wöllenstein, J.; Palzer, S. Gas sensors for climate research. J. Sens. Sens. Syst. 2018, 7, 535–541. [Google Scholar] [CrossRef]
Figure 1. The concept of the individual sensor nodes is based on the use of micromachined sensor technology and internet connectivity in order establish a wireless network for online, in-situ indoor environmental monitoring. The CO2 concentration is determined by listening to its concentration via the photoacoustic effect. Both temperature and humidity are determined using state-of-the-art microtechnology.
Figure 1. The concept of the individual sensor nodes is based on the use of micromachined sensor technology and internet connectivity in order establish a wireless network for online, in-situ indoor environmental monitoring. The CO2 concentration is determined by listening to its concentration via the photoacoustic effect. Both temperature and humidity are determined using state-of-the-art microtechnology.
Sensors 18 04345 g001
Figure 2. Overview of the system installation at the school. Each sensor node is installed at about 1 m height above ground. To ensure reliable data transfer three signal repeaters have been installed. Area and volume of all rooms are annotated in the schematic map and the position of each sensor node is indicated above.
Figure 2. Overview of the system installation at the school. Each sensor node is installed at about 1 m height above ground. To ensure reliable data transfer three signal repeaters have been installed. Area and volume of all rooms are annotated in the schematic map and the position of each sensor node is indicated above.
Sensors 18 04345 g002
Figure 3. (a) Temperature calibration using a climatic chamber to enable corrections for changes in ambient temperature during operation of the sensor module. The blue curve shows the corrected signal. (b) Using a certified gas mixture the dependence of the sensor response on different CO2 concentrations has been established.
Figure 3. (a) Temperature calibration using a climatic chamber to enable corrections for changes in ambient temperature during operation of the sensor module. The blue curve shows the corrected signal. (b) Using a certified gas mixture the dependence of the sensor response on different CO2 concentrations has been established.
Sensors 18 04345 g003
Figure 4. (a) CO2 decay curves measured at different times in the same classroom and the nonlinear regression curves used to estimate the background concentration (Ca). The fit results are stated in the table in the inset. The inset on the right shows a logarithmic representation of the CO2 concentration values after subtraction of the background value Ca to highlight the exponential decay behavior. (b) With closed class room doors the ventilation rate may be neglected as compared to the generation rate, which is why linear models apply. It also allows for determining the level of physical activity via the generation rate of CO2 during class. Knowing the volume of the room and the number of people inside allows for estimating the activity level, which may vary according to the specific activity performed in class.
Figure 4. (a) CO2 decay curves measured at different times in the same classroom and the nonlinear regression curves used to estimate the background concentration (Ca). The fit results are stated in the table in the inset. The inset on the right shows a logarithmic representation of the CO2 concentration values after subtraction of the background value Ca to highlight the exponential decay behavior. (b) With closed class room doors the ventilation rate may be neglected as compared to the generation rate, which is why linear models apply. It also allows for determining the level of physical activity via the generation rate of CO2 during class. Knowing the volume of the room and the number of people inside allows for estimating the activity level, which may vary according to the specific activity performed in class.
Sensors 18 04345 g004
Figure 5. (a) Representation of the thermal comfort, taking into account temperature and relative humidity and its evolution during exemplary days, including a vacation day on 3 April 2018. Notably, good thermal comfort is never achieved because of too much heating during the winter season. (b) The correlation between inside and outside temperature are shown: A class room facing south (e.g., PHI) exceeds the acceptable limit of 25 °C in the majority of days, unlike class rooms facing north (e.g., R.2.21), due to more pronounced influence of heating by the sun.
Figure 5. (a) Representation of the thermal comfort, taking into account temperature and relative humidity and its evolution during exemplary days, including a vacation day on 3 April 2018. Notably, good thermal comfort is never achieved because of too much heating during the winter season. (b) The correlation between inside and outside temperature are shown: A class room facing south (e.g., PHI) exceeds the acceptable limit of 25 °C in the majority of days, unlike class rooms facing north (e.g., R.2.21), due to more pronounced influence of heating by the sun.
Sensors 18 04345 g005
Figure 6. Transient evaluation of temperature, humidity and CO2 concentration in room R2.17 in the period between 19.02.2018 and 19.03.2018. Due to overheating the thermal comfort was only medium throughout the week. The CO2 levels have been recorded to be above 2000 ppm almost every day at some point.
Figure 6. Transient evaluation of temperature, humidity and CO2 concentration in room R2.17 in the period between 19.02.2018 and 19.03.2018. Due to overheating the thermal comfort was only medium throughout the week. The CO2 levels have been recorded to be above 2000 ppm almost every day at some point.
Sensors 18 04345 g006
Figure 7. (a) Exemplary dynamics of the evolution of the CO2 level on three days of the week. Because doors and windows are closed after school finished CO2 can accumulate. (b) The accumulation leads to a constant increase in the background level of CO2, which makes it harder to maintain good CO2 levels the older the week gets.
Figure 7. (a) Exemplary dynamics of the evolution of the CO2 level on three days of the week. Because doors and windows are closed after school finished CO2 can accumulate. (b) The accumulation leads to a constant increase in the background level of CO2, which makes it harder to maintain good CO2 levels the older the week gets.
Sensors 18 04345 g007
Figure 8. Air change rate as a function of the type of ventilation as well as the threshold ventilation rate required to achieve good IAQ. The results show that a 5 minute break is not sufficient to reestablish good IAQ. Only after 15 min of ideal and strong ventilation may low CO2 levels be achieved.
Figure 8. Air change rate as a function of the type of ventilation as well as the threshold ventilation rate required to achieve good IAQ. The results show that a 5 minute break is not sufficient to reestablish good IAQ. Only after 15 min of ideal and strong ventilation may low CO2 levels be achieved.
Sensors 18 04345 g008

Share and Cite

MDPI and ACS Style

Ortiz Perez, A.; Bierer, B.; Scholz, L.; Wöllenstein, J.; Palzer, S. A Wireless Gas Sensor Network to Monitor Indoor Environmental Quality in Schools. Sensors 2018, 18, 4345. https://0-doi-org.brum.beds.ac.uk/10.3390/s18124345

AMA Style

Ortiz Perez A, Bierer B, Scholz L, Wöllenstein J, Palzer S. A Wireless Gas Sensor Network to Monitor Indoor Environmental Quality in Schools. Sensors. 2018; 18(12):4345. https://0-doi-org.brum.beds.ac.uk/10.3390/s18124345

Chicago/Turabian Style

Ortiz Perez, Alvaro, Benedikt Bierer, Louisa Scholz, Jürgen Wöllenstein, and Stefan Palzer. 2018. "A Wireless Gas Sensor Network to Monitor Indoor Environmental Quality in Schools" Sensors 18, no. 12: 4345. https://0-doi-org.brum.beds.ac.uk/10.3390/s18124345

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop