Article

Domestic Wastewater Treatment: A Comparison between an Integrated Hybrid UASB-IFAS System and a Conventional UASB-AS System

1
Environmental Engineering Department, Faculty of Engineering, Zagazig University, Zagazig 44519, Egypt
2
Institute of Environmental Engineering, Faculty of Civil Engineering, Technical, University of Kosice, Vysokoskolska 4, 04001 Kosice, Slovakia
*
Author to whom correspondence should be addressed.
Sustainability 2021, 13(4), 1853; https://0-doi-org.brum.beds.ac.uk/10.3390/su13041853
Submission received: 22 November 2020 / Revised: 2 February 2021 / Accepted: 3 February 2021 / Published: 8 February 2021
(This article belongs to the Special Issue Sustainable Water Resources Management and Waste Water Engineering)

Abstract

:
The current study presents a detailed evaluation and comparison between two integrated anaerobic–aerobic systems for biological wastewater treatment under equal conditions in all aspects (wastewater characteristics, climatic conditions, reactor sizing, and even the measurement methods). The two examined systems are (i) a hybrid upflow anaerobic sludge blanket (hybrid UASB) coupled with integrated fixed-film activated sludge (IFAS) and (ii) a conventional UASB coupled with activated sludge (AS). The present comparative study aims to evaluate and assess the effect of adding carrier-filling media on the performance of the classical integrated UASB-AS. The two parallel pilot-scale systems, hybrid UASB-IFAS and UASB-AS, were installed and operated at a wastewater treatment plant. Three sets of experiments were conducted to examine the influence of the hydraulic retention time (HRT) on the consequent organic and hydraulic loads, temperature, and recirculation rate of the proposed systems. The main results showed that the two investigated systems had a comparably high efficiency for the removal of organic matters and ammonia. Moreover, a paired sample t-test indicated there was a statistically significant effect of the filling media, and the performance of the hybrid UASB-IFAS increased significantly compared with that of the UASB-AS system. An additional benefit of the filling media on the hybrid system was its high stability when changing the organic and hydraulic loads. The optimum HRT was 6 h, with a total chemical oxygen demand (TCOD) percentage removal of approximately 95% in both examined systems. Treatment of sewage under high and low temperatures indicated that increasing the temperature improved the efficiency of the overall process for both systems significantly.

1. Introduction

Water deficiency is a major challenge to sustainable development. This challenge is compounded by rapid population growth, urbanization, environmental pollution, and climate change [1]. It is said that a “Blue Revolution” is required to end the scarcity of water and to save water for agriculture. Presently, water shortage is a worldwide issue; almost half the world’s population suffers from water shortages [2]. Thus, there is a need to develop and improve technologies that mitigate water shortages and increase water supply, one of which is municipal wastewater treatment.
Biological wastewater treatment appears to be a promising technology. Both aerobic and anaerobic processes can be applied. The former involves the use of dissolved oxygen by microorganisms in the conversion of organic matter to biomass and CO2. The latter involves the conversion of complex organic wastes into methane, CO2, and H2O in the absence of oxygen [3].
Anaerobic treatment is a very optimal option for wastewater treatment. It has many benefits, including low energy requirements, low sludge production, and low cost of sludge treatment [4,5]. Other advantages can include the generation of renewable energy from methane, emission mitigation, and possibly hydrogen energy [6]. In this way, anaerobic wastewater treatment is an effective approach by which both energy recovery and pollution control can be achieved [7,8].
There are many configurations of anaerobic treatment systems, among which are upflow anaerobic sludge blanket (UASB) reactors. They are promising anaerobic systems, especially in the developing countries located in warm-water regions. Anaerobic technologies are widely used in warm climates for treating low-strength streams at ambient temperature. UASB reactors are systems with a highly robust rate of treatment due to their easy operation and low construction and operating costs, in addition to their efficiency, flexibility, smaller footprint, and relatively high-quality effluent [9]. However, UASB systems still have significant restrictions when used as a single treatment process. One of these constraints is the insufficient ability to remove organic matters and nitrogen, so the effluent stream cannot meet the effluent discharge standards [10].
The aforementioned limitations of UASB reactors can be reduced by improving the effluent quality using several methods, which can be classified into two main trends. The first trend is to modify the UASB reactor configuration. For instance, Musa et al. [9] enhanced a UASB’s efficiency by applying a solid separator in the upper portion slightly above the sludge blanket, which prevented washout of the sludge from the reactor.
Guiot and van den Berg [11] proposed an anaerobic hybrid UASB reactor with the following configuration: the UASB reactor was in the lower zone, while filling media was added in the upper zone to provide a surface area for additional biomass growth. Hybrid UASB has many advantages compared to classical UASB, including rapid granulation of biomass, a shorter startup period, and higher loading rates [12]. The integrated upflow anaerobic sludge blanket and anaerobic filter (UASB-AF) was recommended by many researchers who stated that adding plastic media in the top-third of the UASB reactor could enhance the efficiency of the reactor [13,14]. The hybrid UASB-AF system provides the advantages of both a UASB reactor and an anaerobic filter, so high cell concentration, good mixing, and tolerance to high loading rates are all available [15]. On the other hand, Lew et al. [16] compared hybrid UASB and the classical UASB, and concluded that both reactor designs had a similar performance at summer conditions (20–28 °C). The hybrid UASB reactor containing filter rings showed no advantage, and it performed slightly worse than the conventional UASB reactor at lower temperatures.
The second trend to achieve the desired UASB effluent standards is to select an appropriate post-treatment scheme [12]. The anaerobic effluent often contains solubilized organic matters, ammonium ions, and hydrogen sulfide. This is suitable for aerobic treatment, indicating the potential of using anaerobic–aerobic systems. Benefits of the anaerobic–aerobic process include resource recovery (biogas production), high overall treatment efficiency, less disposal of sludge, and low energy consumption [3].
A variety of aerobic post-treatment processes can be used. Results obtained from the laboratory and full-scale units in the literature demonstrated that an activated sludge (AS) reactor and a moving-bed biofilm reactor (MBBR) are very effective for post-treatment [16,17,18]. Show et al. [6] examined the feasibility of integrating a series of biological processes (anaerobic granular sludge blanket, aerobic carrier biofilm, and aerobic activated sludge processes) for the treatment of high-strength wastewater. The integrated anaerobic–aerobic system enhanced the effective overall treatment efficiency. A similar integrated system was also recommended by Allegue et al. [10].
On the contrary, the integrated fixed-film activated sludge (IFAS) reactor has been rarely studied as a post-treatment option. The difference between the MBBR and the IFAS relies on the presence of the return activated sludge (RAS). Many studies have strongly recommended the IFAS system over the AS and MBBR reactors. When a full-scale IFAS reactor equipped with plastic media was compared to AS, the applied loading to the IFAS process was approximately twice that of AS, and the TCOD removal percentage and ammonia were almost the same for both processes [19]. Through a deammonification process for treating wastewater, a higher nitrogen-removal rate was achieved by the IFAS reactor in comparison with the MBBR. This was due to the higher relative abundance of ammonium-oxidizing bacteria in suspended biomass and the increase of the total aerobic capacity of the system [20]. The IFAS system gains the advantages of the biofilm reactor and the activated sludge process. IFAS increases the sludge-retention time, enhances nitrification, improves process stability, and reduces excess sludge production with better settling characteristics. IFAS achieves a high treatment efficiency even at higher organic loads compared with the AS system. The biofilm in IFAS offers several advantages: reduced footprint, enhanced nutrients removals, and longer solid-retention time [21,22].
Previous studies indicated that applying carrier-filling media in both UASB and AS reactors can enhance their performance. Moreover, the use of the filling media is costly and requires special infrastructural facilities. The current work aims to assess the effect of adding plastic filling media on the performance of the classical integrated UASB-AS system. This is to determine whether it is a beneficial option to use this filling media for the UASB-AS system. The developed system is composed of a UASB coupled with an anaerobic filter (hybrid UASB) followed by IFAS. The two investigated systems (hybrid UASB-IFAS and classical UASB-AS), will be thoroughly compared in all conditions, and the main operating parameters of HRT, temperature, and sludge recirculation will be investigated. The experimental work was performed using pilot scale reactors installed and operated in the field (a wastewater treatment plant).

2. Materials and Methods

2.1. Wastewater Characteristics

The experimental reactors were installed and operated in the field, at the Al-Qenayat Wastewater Treatment Plant (WWTP) in Zagazig, Sharkia, Egypt. The wastewater utilized was real municipal wastewater with variable characteristics. The reactors were fed with gritted wastewater using centrifugal pumps. In order to mitigate the flow-rate variation, a constant head tank was installed ahead of the reactors. A summary of the characteristics of the influent wastewater is given in Table 1.

2.2. Reactor Setup and Operation

The experiments were carried out using two pilot-scale systems (hybrid UASB-IFAS and UASB-AS) operated in parallel. Figure 1 shows a process-flow diagram of the pilot plant. Each of the two anaerobic reactors (hybrid UASB and conventional UASB) was configured as a cylindrical tank with a 465-L volume. Samples were collected from four sampling ports placed at different heights. An inflow distributor system was installed at the bottom of the reactor to ensure influent distributions. The hybrid UASB had plastic media (500 m2/m3) filling the top part of the reactor. The media-filling ratio for the hybrid UASB was 23% of its volume.
The effluent post-treatment of the hybrid UASB reactor was done by using IFAS. The IFAS system consisted of an aerobic bioreactor with a working volume of 525 L that had a media-filling ratio of 30% and a settling tank with a volume of 150 L. Abdo et al. [23] compared the classical activated-sludge process with the IFAS system, with different filling plastic carrier media ranging from 10–70%. They recommended 30% as the optimum media-filling ratio, and concluded that the organic-removal ratio was enhanced slightly at the 10–50% filling ratio. Similarly, Waqas et al. [22] confirmed that the media-filling ratio ranges from 30% to 70%, and the average filling ratio is about 35%. For the UASB-AS reactor, post-treatment was done with the AS system. The volume of the aerobic bioreactor and settling tanks were 525 L and 150 L, respectively. The excess sludge from aeration tanks was recirculated to the bottom of anaerobic reactors.
Three sets of experiments were conducted to examine the influence of the HRT, temperature, and recirculation rate on the performance of the hybrid UASB-IFAS and UASB-AS combinations. In the first set of experiments, the two systems were operated for 186 days, divided into five time intervals: 0–42, 42–77, 77–114, 114–146, and 146–186 days at an HRT of 15, 12, 9, 6, and 3 h, respectively. The effect of temperature was studied in the second set of experiments. The reactors were operated for cold-climate conditions at a temperature range of 9–15.5 °C for 40 days, and for hot-climate conditions at 25–33 °C for 24 days. The third experimental set was conducted to examine the effect of the sludge recirculation rate from aeration reactors to anaerobic reactors. The two systems were operated with no recirculation in the first run. In the second and third runs, the recirculation from the aeration reactors was 52.5 L/day and 210 L/day, respectively. The main operational conditions are shown in Table 2. The total HRT is defined as the residence time of wastewater in the whole system, which equals the sum of retention time of the anaerobic unit and that of the aerobic unit.

2.3. Sampling and Analytical Methods

Samples of the influent and the effluents of the anaerobic and aerobic reactors were collected and analyzed. The TCOD, biological oxygen demand (BOD5), TSS, and ammonia were determined according to the standard methods [24]. The biomass concentration in the AS and IFAS expressed as solid concentration was measured and presented as a mixed liquor suspended solid (MLSS). The samples were taken twice weekly. Dissolved oxygen (DO) was measured and monitored with a digital meter. The DO, temperature, and pH were measured on site daily. Volatile fatty acids (VFA) were determined by the Kappa titration method [25].

3. Results and Discussion

A classical UASB reactor can be modified by using filling media in order to increase its efficiency and ability to withstand excessive organic and hydraulic loads. The efficiency of the AS process can also be upgraded in the same manner by adding the media. In the two systems that were chosen for the study, one of them—the hybrid UASB-IFAS—has the benefit of using media in both of its stages. On the other hand, the UASB-AS system consists of two parts, both of which follows traditional methods. The two pilot plants of the two systems were continuously operated over a period of 186 days, with different HRTs of 15, 12, 9, 6, and 3 h, and a wide range of organic loading rate (OLR) (from 1.5 to 15.4 Kg TCOD/m3.day). Many measurements and parameters were observed to clarify the differences between the two systems.

3.1. TCOD Removal

Figure 2 and Figure 3 and Table 3 illustrate the variation in the influent and the effluent TCOD and the performance of the reactors at each HRT. Due to the variance of wastewater characteristics, the organic load for each run was not constant. The results presented in Figure 3 show the effect of changing the HRTs and subsequently OLR on the TCOD removal ratio provided by the hybrid UASB-IFAS and UASB-AS systems. The COD dataset at different HRTs was statistically analyzed with a paired-sample t-test. IBM SPSS Statistics software package was used for the analysis. The paired-sample t-test can explore whether there is a statistically significant difference between the performance of the two examined systems. The results from the paired t-test showed that the arithmetic mean of the COD effluent (at all HRTs) for the hybrid UASB-IFAS equaled 42 mg/L, compared with 61.5 mg/L for the UASB-AS system. The paired t-test indicated that the t value was 7.48 (compared with the critical value (TC) of 2), at a 95% level of significance and 32 degrees of freedom. The higher t value with positive sign denoted that outlet values of the hybrid UASB-IFAS system decreased significantly if compared with the values the UASB-AS system. The comparison also indicated that the hybrid UASB-IFAS system significantly outperformed the UASB-AS system. The higher performance of the hybrid reactors could be attributed to better granulation and biofilm establishment.
TCOD values for effluent were less than 78 mg/L. These values fall under the Egyptian environmental requirements (the value of TCOD should not be more than 80 mg/L). The results revealed that the removal of TCOD in the combined hybrid UASB-IFAS system was not significantly affected by decreasing the total HRT from 15 to 12 and then to 9 h. But when the HRT was reduced to 6 h, the efficiency increased; when it reached 3 h, the TCOD removal value returned to its previous rate. The TCOD removal percent was above 92% for all the HRTs. Similar results were observed by Allegue et al. [10]. They used a pilot plant composed of a UASB followed by an IFAS system. They aimed to evaluate the feasibility of using an integrated fixed-film activated sludge (IFAS) system as a post-treatment technology, and the system achieved TCOD removal efficiencies of 92 ± 3%.
For the UASB-AS system, the same trend was observed. The removal percentage was above 88%, and the optimum removal achieved was 95% at 6 h. In general, TCOD values for the UASB-AS system effluent were less than the requirements of Egyptian environmental standards. However, some results (at HRT = 15 h for the UASB-AS system) did not match the standards because the effluent TCOD was more than 80 mg/L. However, removal ratios were still achieved at a high rate. It was noticed in this case that the anaerobic part of the system did its job well, and the shortening was associated with the aerobic part. This may be due to the low temperature. At HRT = 3 h, some TCOD results for the UASB-AS system effluent were more than 80 mg/L due to a high OLR, which was ≥11.79 kg TCOD/m3.day. These results indicated that the IFAS system was more stable and had better results than the AS system.
The experiments were done at ambient temperature and, as shown in Figure 3, began in the winter, so as the HRT changed from 15 h to 3 h, the temperature increased. This can account for the high removal efficiency at an HRT of 6 h. Because of the uncertain relation between the increase in temperature and the increase in the removal efficiency, the effect of temperature was studied later.
The obtained trend for the effect of HRT on the overall system performance was in accordance with other studies. For the treatment of wastewater containing toxic phenolics at influent TCOD of 2240 mg/L in both the hybrid UASB and the classical UASB, the TCOD removal ratios at HRTs of 18, 15.8, 9.4, and 8 h were 84.5, 84.5, 91, and 84%, respectively in the hybrid UASB, in comparison with 83.5, 84.4, 90, and 83%, respectively, in the UASB reactor [26]. The hybrid UASB achieved a 4.5% removal ratio, higher than for the UASB at an HRT of 6 h. These results are in line with those obtained by Elmitwalli et al. [27], who compared the performances of a hybrid UASB and a UASB reactor for pre-settled sewage treatment at 13 °C and an HRT of 8 h. The hybrid UASB filter reactor reached 64% of total TCOD removal, a 4% higher removal than the classical UASB.

3.2. BOD5 Removal

The performance data of the hybrid UASB-IFAS system shown in Figure 4 and Figure 5 and Table 4 revealed that the high total BOD5 removal ranged from 96% at HRT = 15 h to 92% at HRT = 3 h, with a peak value of 98% at HRT = 6 h. On the other hand, the BOD5 removal from the outlet of the hybrid UASB unit ranged from 62% to 83%. For the UASB-AS system, the BOD5 removal ranged from 94% at HRT = 15 h to 91% at HRT = 3 h, with a peak value of 97% at HRT = 6 h. These results indicated that the decrease in the total HRT did not have a significant effect on the total removal efficiency of BOD5 in both systems. The reduction of the HRT led to a decrease in the BOD5 removal efficiency of the anaerobic reactors. However, the aerobic process was able to overcome the load increase, and the final effluent quality was not significantly affected. BOD5 values for effluent were less than the Egyptian environmental requirements, which require a value of BOD5 no more than 60 mg/L. The BOD dataset at different HRTs was statistically analyzed. The results from the paired t-test showed that the BOD removal for the two examined systems had the same trend as the COD, and the hybrid UASB-IFAS system significantly outperformed the UASB-AS system.

3.3. Ammonia Removal

Figure 6 and Table 5 show the variations in the influent and effluent concentration of ammonia in the two systems at different HRTs. The results show that decreasing the HRT from 15 to 12 h and from 12 to 9 h, then to 6 h, did not significantly affect the efficiency of the overall system, as reflected in the residual ammonia values. Ammonia values for the effluent were less than the Egyptian environmental requirements, which require a value of ammonia no more than 3 mg/L. When the HRT was reduced to 3 h, the remaining ammonia increased and the efficiency decreased significantly. The values of the ammonia effluent were less than 1.3 for the hybrid UASB-IFAS system and 0.7 mg/L for the UASB-AS system in all phases, except the value of 8 mg/L obtained at a 3 h HRT. The good behavior of the two systems was also shown in terms of the removal efficiency. The removal efficiencies of ammonia for the hybrid UASB-IFAS and the UASB-AS systems had values higher than 90% and 94%, respectively, except the value obtained at an HRT of 3 h. It was noticed that both systems failed to maintain their stabilities for the higher hydraulic loading rate (HLR). Recorded values for removal efficiency were 51% for the hybrid UASB-IFAS and 47% for the UASB-AS system, obtained at an HRT of 3 h. The ammonia dataset at different HRTs was statistically analyzed. The paired t-test indicated that the t value was −1.5 (compared with the critical value (TC) of −2.06), at a 95% level of significance and 25 degrees of freedom. The higher t value with a negative sign denoted that the increase of outlet values for the hybrid UASB-IFAS system was not significant if compared with the values the UASB-AS system.
For higher HLR and OLR, the results of the present study indicated that the two systems failed to maintain a higher removal ratio for ammonia. It can be concluded that the decrease in the ammonia removal rate was because the HRT was too short to complete the nitrification process. An increase in the carbon loading, due to a short HRT, can lead to an increase in the heterotrophic bacteria numbers in both the attached and suspended biomass, and therefore to a decrease in nitrifier numbers, as there is more competition for space, oxygen, and substrate for the heterotrophic bacteria [28]. In this context, Moawad et al. [29] concluded that complete nitrification of ammonia was achieved after 5 h of aeration. Similar results were observed by Allegue et al. [10], who observed ammonium removal efficiencies of around 57 ± 16% throughout the entire operation.

3.4. Total Suspended Solid (TSS) Removal

The results shown in Table 6 and Figure 7 and Figure 8 revealed that the percentage of TSS removal was almost the same in the anaerobic and post-treatment steps despite changing the HRT. For the hybrid UASB-IFAS, the effluent TSS was 160, 162, 143, 154, and 142 mg/L for the hybrid UASB, and 25, 25, 24, 25, and 21 mg/L for the IFAS reactor, at HRTs of 15, 12, 9, 6, and 3 h, respectively. For the UASB-AS, the effluent TSS was 164, 171, 147, 162, and 146 mg/L for the anaerobic reactor and 30, 29, 27, 28, and 27 mg/L for the aerobic reactor at HRTs of 15, 12, 9, 6, and 3 h, respectively. The overall removal rate was between 91.3–93.0% and 90.1–91.2% for the hybrid UASB-IFAS and the UASB-AS, respectively. For both systems, an almost constant removal rate above 90% and an average effluent concentration of less than 30 mg/L were observed despite changing the HRT. The TSS concentration in the influent and final effluent of the pilot-scale reactors varied from 273 to 319 mg/L and from 21 to 30 mg/L, respectively. This corresponds to a 90–93% reduction in the TSS. The obtained results indicated that the removal of TSS in the two combined systems was independent on the total HRT.

3.5. Other Performance Parameters of the Examined Systems

Table 7 shows other performance parameters for the experimental investigated systems, including pH, DO, MLSS, VFAs, and alkalinity.
As indicated in Table 7; the pH measurements were neutral for the wastewater at all stages, and ranged from 6.8 to 8. The two investigated systems achieved high VFA removal.
The DO level inside the aeration tank for the AS and IFAS systems was maintained above 2 mg/L. This was higher than the value of 1.3 mg/L recommended by Khayi [30], who evaluated the UASB reactor by integrating it with the IFAS to find the optimal aeration DO level that could achieve the maximum nitrogen efficacy. The MLSS inside the aeration tank was variable according to the different operational conditions, and ranged from 2000 to 5180 mg/L.

3.6. Effect of Climate Temperature Fluctuations

The effect of climate temperature fluctuations on the performance of the hybrid UASB-IFAS and UASB-AS was monitored for the treatment of domestic wastewater at two different operational temperatures (9–15.5 °C and 25–30 °C) and a total HRT of 15 h. The performance of the reactors is shown in Figure 9. It is clear that the increase of temperature improved the efficiency of the overall system for both TCOD and BOD5 by about 3–8%. The effect of temperature on the anaerobic stages accounted for about 6–17% removal enhancement. The dataset for cold and hot climate conditions was statistically analyzed. The paired t-test indicated that the temperature enhanced the overall performance of both examined systems significantly. These findings are in agreement with the results of other studies. Liu and Tay [31] argued that high temperatures enhance methanogenesis. Rizvi et al. [32] reported that there was an increase in the efficiency of the UASB reactors with an increase in the temperature; in their study, the TCOD removal efficiency of the UASB reached 62, 68, and 77% at 17, 20, and 25 °C, respectively. The removal ratio for ammonia in anaerobic reactors for both systems in a cold climate was very low, while the overall removal efficiency for the two investigated systems was affected slightly. The average percentage removal of TSS was also enhanced as the temperature increased.

3.7. Effect of Activated Sludge Recirculation Rate

One of the biggest advantages of the UASB reactor is the production of stabilized sludge. The excess sludge from the aeration tank was returned to the UASB reactor. The effect of the activated sludge recirculation rate, from the aerobic reactor to the anaerobic reactor, was investigated. Three experimental runs of the two systems were studied and a mixed liquor from the IFAS and AS was recirculated to the hybrid UASB and UASB at a rate of 0, 52.5, and 210 L/day and an overall HRT of 3 h. Sludge wastage in the first run was accomplished by wasting mixed liquor suspended solid (MLSS) from the aerobic reactor. In the second and third runs, the sludge was wasted from the anaerobic unit. This resulted in a sludge retention time (SRT) in the aeration tank of 10 day in the first and second runs and 2.5 day in the third run. Figure 10 depicts the TCOD, BOD5, ammonia, and TSS removal efficiencies for both systems.
For the hybrid UASB-IFAS system, the overall TCOD removal efficiency was 93% for the first run and 92% for the second and third runs, and was not significantly affected by recirculation rate. As for the UASB-AS system, the overall TCOD removal efficiency was 91% and 89% in the first and second runs, respectively (SRT = 10 day), and decreased to 85% in the third run (SRT = 2.5 day). Similar behavior was observed for the two anaerobic reactors, with a removal ratio of 68% for the first run, 60% for the second run, and 62% for the third run.
The dataset at low and high circulation rates was statistically analyzed and compared with that of no circulation, at a 95% level of significance and 4 degrees of freedom. The statistical comparison indicated that the effect of the sludge circulation rate was not significant for the hybrid UASB-IFAS. The paired t-test also indicated that the low-rate circulation effect was not significant for the UASB-AS system, while the high rate reduced the performance significantly.
The results shown in Figure 10 revealed that the removal of BOD5 in the combined systems was not significantly affected by the recirculation rate. The major part of BOD5 was removed in the anaerobic reactor, and little additional removal occurred in the aerobic reactor. At recirculation rates of 0, 52.5, and 210 L/day, the overall percentage removal values for the hybrid UASB-IFAS were 93, 92, and 90%, respectively. At a recirculation rate of 0, 52.5, and 210 L/day, the overall percentage removal values for the UASB-AS were 92, 91, and 90%, respectively. This indicated that the removal of organic matter and suspended solids was independent from the recirculation ratio.
These results are in agreement with those of Pontes et al. [33], who investigated the performance of an integrated UASB and trickling filter (TF) system using domestic sewage, and studied the effect of recirculation of excess sludge produced from TF on the performance. No detrimental effect was observed due to feeding of aerobic excess sludge to the UASB reactor.
The results show that the ammonia removal improved slightly when the recirculation ratio was high, at 210 L/day. The improvement of nitrogen removal in an integrated system (consisting of anaerobic and aerobic reactors) may occur by using the anaerobic reactor for the denitrification process, as described by several researchers. Huang et al. [34] studied a combined system consisting of an UASB reactor and an AS reactor with a recycle ratio to influent of 1, 2, and 3 for the treatment of low-strength synthetic wastewater, and concluded that a higher recycle ratio resulted in an increase in the total nitrogen removal efficiency.

4. Conclusions

The aim of our study was to evaluate the effect of carrier-filling media on the performance of a classical integrated UASB-AS system, to determine whether it is a beneficial option to apply this filling media in UASB/AS systems, because the use of the filling media is cost-intensive and requires special infrastructure. The comparison between the conventional UASB-AS integrated system and the hybrid UASB-IFAS modified reactors demonstrated that both systems have comparably high efficiencies in organic matter removal (attained > 95%). Statistical analysis indicated that the carrier-filling media enhanced the efficiency significantly. An additional observed benefit of the carrier-filling media on the hybrid system was its high stability when changing the organic and hydraulic loads. For both examined systems, the results indicated that a large part of the organic matter was removed in the anaerobic reactors, and little additional removal occurred in the aerobic units. As for the ammonia, residuals values were in the accepted range for both systems at all HRTs except 3 h. Also, the results showed that nitrogen removal was very low or absent in the anaerobic units. Treatment of sewage by hybrid UASB-IFAS or UASB-AS reactors, under high and low temperatures, indicated that an increase in temperature improves the efficiency of the overall system significantly, especially the anaerobic reactors. There was a not significant change in the removal ratios of TCOD and BOD5, as the recirculation ratio of the activated sludge, from the aeration tank to the anaerobic unit, increased. On the contrary, the removal ratio of ammonia improved slightly when the recirculation ratio increased.

Author Contributions

Conceptualization, A.A. and M.Z.; methodology, I.H.; software, I.H.; validation, A.M.D.; formal analysis, M.Z.; investigation, A.M.D.; resources, A.A. and M.Z.; data curation, A.M.D. and A.A.; writing—original draft preparation, A.M.D. and I.H.; writing—review and editing, A.A., and M.Z.; visualization, I.H. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data available on request due to restrictions privacy.

Acknowledgments

The authors express their gratitude to the staff of the Environmental Engineering Laboratory, Faculty of Engineering, Zagazig University. This work was supported by the project of the Ministry of Education of the Slovak Republic VEGA 1/0308/20—Mitigation of hydrological hazards—floods and droughts—by exploring extreme hydroclimatic phenomena in river basins; and the project of the Slovak Research and Development Agency APVV-18-0360—Active hybrid infrastructure towards a sponge city.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Liu, W.; Song, X.; Huda, N.; Xie, M.; Li, G.; Luo, W. Comparison between aerobic and anaerobic membrane bioreactors for trace organic contaminant removal in wastewater treatment. Environ. Technol. Innov. 2020, 17, 100564. [Google Scholar] [CrossRef]
  2. Nisar, M.B.; Shah, S.A.R.; Tariq, M.O.; Waseem, M. Sustainable wastewater treatment and utilization: A conceptual innovative recycling solution system for water resource recovery. Sustainability 2020, 12, 10350. [Google Scholar] [CrossRef]
  3. Chan, Y.J.; Chong, M.F.; Law, C.L.; Hassell, D.G. A review on anaerobic–aerobic treatment of industrial and municipal wastewater. Chem. Eng. J. 2009, 155, 1–18. [Google Scholar] [CrossRef]
  4. Mrowiec, B.; Suschka, J. Anaerobic Wastewater Treatment Process. In Research and Application of New Technologies in Wastewater Treatment and Municipal Solid Waste Disposal in Ukraine, Sweden, and Poland; Plaza, E., Lewin, E., Eds.; KTH: Stockholm, Sweden, 2010; pp. 177–184. [Google Scholar]
  5. Chong, S.; Sen, T.K.; Kayaalp, A.; Ang, H.M. The performance enhancements of Upflow Anaerobic Sludge Blanket (UASB) reactors for domestic sludge treatment—A state-of-the-art review. Water Res. 2012, 46, 3434–3470. [Google Scholar] [CrossRef]
  6. Show, K.Y.; Yan, Y.; Zhao, J.; Shen, J.; Han, Z.; Yao, H.Y.; Lee, D.J. Laboratory trial and full-scale implementation of integrated anaerobic-aerobic treatment for high strength acrylic acid wastewater. Sci. Total Environ. 2020, 738, 140323. [Google Scholar] [CrossRef] [PubMed]
  7. Abdelgadir, A.; Chen, X.; Liu, J.; Xie, X.; Zhang, J.; Zhang, K.; Wang, H.; Liu, N. Characteristics, Process Parameters, and Inner Components of Anaerobic Bioreactors. BioMed. Res. Int. 2014, 2014, 841573. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  8. Hluštík, P.; Zeleňáková, M. Risk Analysis of Failure in Sewer Systems in Czech Municipalities. Pol. J. Environ. Stud. 2019, 28, 4183–4190. [Google Scholar] [CrossRef]
  9. Musa, M.A.; Idrus, S.; Man, H.C.; Daud, N.N.N. Performance Comparison of Conventional and Modified Upflow Anaerobic Sludge Blanket (UASB) Reactors Treating High-Strength Cattle Slaughterhouse. Wastewater Water 2019, 11, 806. [Google Scholar] [CrossRef] [Green Version]
  10. Allegue, T.; Carballo-Costa, M.N.; Fernandez-Gonzalez, N.; Garrido, J.M. Simultaneous nitrogen and dissolved methane removal from an upflow anaerobic sludge blanket reactor effluent using an integrated fixed-film activated sludge system. J. Environ. Manag. 2020, 263, 110395. [Google Scholar] [CrossRef]
  11. Guiot, S.R.; van den Berg, L. Performance of an upflow anaerobic reactor combining a sludge blanket and filter treating sugar waste. Biotechnol. Bioeng. 1985, 27, 800–806. [Google Scholar] [CrossRef]
  12. Khan, A.A.; Gaur, R.Z.; Tyagi, V.K.; Khursheed, A.; Lew, B.; Mehrotra, I.; Kazmi, A.A. Sustainable options for post treatment of UASB effluent treating sewage: A review. Resour. Conserv. Recycl. 2011, 55, 1232–1251. [Google Scholar] [CrossRef]
  13. Shivayogimath, C.B.; Ramanujam, T.K. Treatment of distillery spentwash by hybrid UASB reactor. Bioprocess Eng. 1999, 21, 255–259. [Google Scholar] [CrossRef]
  14. Mendonça, H.V.; Ometto, J.P.H.B.; Otenio, M.H.; Delgado Dos Reis, A.J.; Marques, I.P.R. Bioenergy recovery from cattle wastewater in an UASB-AF hybrid reactor. Water Sci. Technol. 2017, 76, 2268–2279. [Google Scholar] [CrossRef] [PubMed]
  15. Ayati, B.; Ganjidoust, H. Comparing the Efficiency of UAFF and UASB with Hybrid Reactor in Treating Wood Fiber Wastewater. J. Environ. Health Sci. Eng. 2006, 3, 39–44. [Google Scholar]
  16. Lew, B.; Tarre, S.; Belavski, M.; Green, M. UASB reactor for domestic wastewater treatment at low temperatures: A comparison between a classical UASB and hybrid UASB-filter reactor. Water Sci. Technol. 2004, 49, 295–301. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  17. Luostarinen, S.; Rintala, J. Anaerobic on-site black water and kitchen waste treatment using UASB-septic tanks at low temperatures. Water Sci. Technol. 2006, 54, 143–149. [Google Scholar] [CrossRef] [PubMed]
  18. Cao, Y.; Ang, C.M. Coupled UASB-activated sludge process for COD and nitrogen removals in municipal sewage treatment in warm climate. Water Sci. Technol. 2009, 60, 2829–2839. [Google Scholar] [CrossRef] [PubMed]
  19. Rosso, D.; Lothman, S.E.; Jeung, M.K.; Pitt, P.; Gellner, W.J.; Stone, A.L.; Howard, D. Oxygen transfer and uptake, nutrient removal, and energy footprint of parallel full-scale IFAS and activated sludge processes. Water Res. 2011, 45, 5987–5996. [Google Scholar] [CrossRef]
  20. Malovany, A.; Trela, J.; Plaza, E. Mainstream wastewater treatment in integrated fixed film activated sludge (IFAS) reactor by partial nitritation/anammox process. Bioresour. Technol. 2015, 198, 478–487. [Google Scholar] [CrossRef]
  21. Kwon, S.; Kim, T.S.; Yu, G.H.; Jung, J.H.; Park, H.D. Bacterial community composition and diversity of a full-scale integrated fixed-film activated sludge system as investigated by pyrosequencing. J. Microbiol. Biotechnol. 2010, 20, 1717–1723. [Google Scholar]
  22. Waqas, S.; Bilad, M.R.; Man, Z.; Wibisono, Y.; Jaafar, J.; Mahlia, T.M.I.; Khan, A.L.; Aslam, M. Recent progress in integrated fixed-film activated sludge process for wastewater treatment: A review. J. Environ. Manag. 2020, 268, 110718. [Google Scholar] [CrossRef]
  23. Abdo, A.; Nagy, N.; Nagieb, A.; Hendy, I. Calibration and Identification of Activated Sludge Model No. 1 (ASM1) for Modeling and Simulation of Egyptian Wastewater Treatment Plants. Ph.D. Thesis, Zagazig University, Ash Sharqiyah, Egypt, 2017. [Google Scholar]
  24. American Public Health Association (APHA). Standard Method for Examination of Water and Wastewater, 21st ed.; APHA, AWWA, WPCF: Washington, DC, USA, 2005. [Google Scholar]
  25. Buchauer, K. A comparison of two simple titration procedures to determine volatile fatty acids in influents to waste-water and sludge treatment processes. Water SA 1998, 24, 49–56. [Google Scholar]
  26. Ramakrishnan, A.; Surampalli, R.Y. Comparative performance of UASB and anaerobic hybrid reactors for the treatment of complex phenolic wastewater. Bioresour. Technol. 2012, 123, 352–359. [Google Scholar] [CrossRef] [PubMed]
  27. Elmitwalli, T.A.; Zandvoort, M.H.; Zeeman, G.; Bruning, H.; Lettinga, G. Low temperature treatment of domestic sewage in upflow anaerobic sludge blanket and anaerobic hybrid reactors. Wat. Sci. Technol. 1999, 39, 177–185. [Google Scholar] [CrossRef]
  28. Wijeyekoon, S.; Mino, T.; Satoh, H.; Matsuo, T. Effects of substrate loadings rate on biofilm structure. Water Res. 2004, 38, 2479–2488. [Google Scholar] [CrossRef]
  29. Moawad, A.; Mahmoud, U.F.; El-Khateeb, M.A.; El-Molla, E. Coupling of sequencing batch reactor and UASB reactor for domestic wastewater treatment. Desalination 2009, 242, 325–335. [Google Scholar] [CrossRef]
  30. Khayi, N. Deammonification Efficiency in Combined UASB and IFAS System for Mainstream WWT. Master’s Thesis, KTH, Stockholm, Sweden, 2017. [Google Scholar]
  31. Liu, Y.; Tay, J.H. State of the art of biogranulation technology for wastewater treatment. Biotechnol. Adv. 2004, 22, 533–563. [Google Scholar] [CrossRef]
  32. Rizvi, H.; Ahmad, N.; Yasar, A.; Bukhari, K.; Khan, H. Disinfection of UASB-treated municipal wastewater by H2O2, UV, ozone, PAA, H2O2/sunlight, and advanced oxidation processes: Regrowth potential of pathogens. Pol. J. Environ. Stud. 2013, 22, 1153–1161. [Google Scholar]
  33. Pontes, P.P.; Chernicharo, C.A.L.; Frade, E.C.; Porto, M.T.R. Performance evaluation of an UASB reactor used for combined treatment of domestic sewage and excess aerobic sludge from a trickling filter. Water Sci. Technol. 2003, 48, 227–234. [Google Scholar] [CrossRef]
  34. Huang, J.; Huang, H.; Chiang, C. Effect of recycle-to-influent ratio on activities of nitrifiers and denitrifiers in a combined UASB-activated sludge reactor system. Chemosphere 2007, 68, 382–388. [Google Scholar] [CrossRef]
Figure 1. Schematic drawing of the pilot plant.
Figure 1. Schematic drawing of the pilot plant.
Sustainability 13 01853 g001
Figure 2. Variations in the influent and effluent TCOD during the HRT study.
Figure 2. Variations in the influent and effluent TCOD during the HRT study.
Sustainability 13 01853 g002
Figure 3. Effects of HRT on the TCOD removal ratio.
Figure 3. Effects of HRT on the TCOD removal ratio.
Sustainability 13 01853 g003
Figure 4. Variations in the influent and effluent BOD5 during the HRT study.
Figure 4. Variations in the influent and effluent BOD5 during the HRT study.
Sustainability 13 01853 g004
Figure 5. Effects of HRT on the BOD5 removal ratio.
Figure 5. Effects of HRT on the BOD5 removal ratio.
Sustainability 13 01853 g005
Figure 6. Variations in the influent and effluent ammonia during the HRT study.
Figure 6. Variations in the influent and effluent ammonia during the HRT study.
Sustainability 13 01853 g006
Figure 7. Variations in the influent and effluent TSS during the HRT study.
Figure 7. Variations in the influent and effluent TSS during the HRT study.
Sustainability 13 01853 g007
Figure 8. Effects of HRT on the TSS removal ratio.
Figure 8. Effects of HRT on the TSS removal ratio.
Sustainability 13 01853 g008
Figure 9. Average removal in hot and cold climates for (a) TCOD; (b) BOD5; (c) ammonia; (d) TSS.
Figure 9. Average removal in hot and cold climates for (a) TCOD; (b) BOD5; (c) ammonia; (d) TSS.
Sustainability 13 01853 g009
Figure 10. Effect of the recirculation rate on (a) TCOD; (b) BOD5; (c) ammonia; (d) TSS.
Figure 10. Effect of the recirculation rate on (a) TCOD; (b) BOD5; (c) ammonia; (d) TSS.
Sustainability 13 01853 g010
Table 1. Influent wastewater characteristics.
Table 1. Influent wastewater characteristics.
ParameterpHTCOD (mg/L)BOD5 (mg/L)NH3 (mg/L)TSS (mg/L)VFA (mg/L)Alkalinity (mg/L)
Mean values7635 305 1631084 251
Standard deviations(0.5)(195)(101)(9)(67)(128)(107)
Table 2. Operational conditions of the tested systems.
Table 2. Operational conditions of the tested systems.
Total HRT (h)Anaerobic HRT (h)Aerobic HRT (h)Flow Rate (m3/day)
15781.61
125.56.52
9452.9
62.73.34
31.41.68
Table 3. TCOD results for the two investigated systems.
Table 3. TCOD results for the two investigated systems.
ParameterInfluentTemperatureAnaerobic EffluentAerobic Effluent
(°C)Hybrid UASBUASBIFASAS
HRT = 15 h
Mean711121972034978
Median700 2022075080
Standard error279 80731314
Removal ratio 72.371.593.189.1
HRT = 12 h
Mean540171811984466
Median567 1551754165
Standard error158 494786
Removal ratio 66.563.391.887.8
HRT = 9 h
Mean546251761884253
Median586 1841953152
Standard error170 62631711
Removal ratio 67.865.692.390.3
HRT = 6 h
Mean646261752042432
Median572 1902112130
Standard error242 544854
Removal ratio 72.968.496.395.1
HRT = 3 h
Mean658312512645173
Median612 2542555171
Standard error150 45511815
Removal ratio 61.859.892.388.9
Table 4. BOD5 results for the two investigated systems.
Table 4. BOD5 results for the two investigated systems.
ParameterInfluentTemperatureAnaerobic EffluentAerobic Effluent
(°C)Hybrid UASBUASBIFASAS
HRT = 15 h
Mean3331255591419
Median321 47531118
Standard error97 2228811
Removal ratio 83.482.295.994.3
HRT = 12 h
Mean2331786931217
Median244 89901417
Standard error63 223053
Removal ratio 63.160.194.792.8
HRT = 9 h
Mean224257986912
Median228 8587812
Standard error50 21922
Removal ratio 64.961.496.294.6
HRT = 6 h
Mean29426103104610
Median270 1099369
Standard error118 253311
Removal ratio 65.164.697.996.7
HRT = 3 h
Mean282311071132225
Median290 1241202120
Standard error65 2630109
Removal ratio 61.96092.291.1
Table 5. Ammonia results for the two investigated systems.
Table 5. Ammonia results for the two investigated systems.
ParameterInfluentTemperatureAnaerobic EffluentAerobic Effluent
(°C)Hybrid UASBUASBIFASAS
HRT = 15 h
Mean912890.40.2
Median8 9100.20.2
Standard error4.5 3.45.00.30.1
Removal ratio 12.9-95.197.5
HRT = 12 h
Mean171715.717.91.30.5
Median20 11.917.21.60.6
Standard error10.0 9.59.90.60.2
Removal ratio 7.4-92.497
HRT = 9 h
Mean20.82521.81910.3
Median29.5 24.720.31.00.3
Standard error14.0 17.511.50.70.2
Removal ratio -8.595.398.5
HRT = 6 h
Mean11.3261110.41.10.7
Median10.4 10.79.71.10.7
Standard error7.7 6.07.50.50.4
Removal ratio 2.58.390.294.2
HRT = 3 h
Mean1631171788
Median17.2 16.616.56.58.0
Standard error6.2 6.15.72.51.6
Removal ratio --51.447.9
Table 6. TSS results for the two investigated systems.
Table 6. TSS results for the two investigated systems.
ParameterInfluentTemperatureAnaerobic EffluentAerobic Effluent
(°C)Hybrid UASBUASBIFASAS
HRT = 15 h
Mean319121601642530
Median311 1571662530
Standard error41.5 18.614.62.21.6
Removal ratio 49.948.79290.6
HRT = 12 h
Mean306171621712529
Median289 1621672528
Standard error73.2 24.224.72.44.7
Removal ratio 46.944.191.890.4
HRT = 9 h
Mean273251431472427
Median258 1421432326
Standard error69.9 34.229.13.03.4
Removal ratio 47.546.391.390.1
HRT = 6 h
Mean310261541622528
Median280 1501472528
Standard error85.4 42.342.42.54.6
Removal ratio 50.547.792.191
HRT = 3 h
Mean307311421462127
Median296 1461512226
Standard error36.8 13.510.14.48.3
Removal ratio 53.852.29391.2
Table 7. Other performance parameters for the investigated systems.
Table 7. Other performance parameters for the investigated systems.
ParameterRawAnaerobic UnitAerobic Unit
Hybrid UASBUASBIFASAS
HRT = 15 h
pH7.27.47.57.77.5
DO (mg/L) 0.20.34.45.2
MLSS (mg/L) 4200700051803445
VFA (mg/L)20101055
Alkalinity (mg/L)265272280185190
HRT = 12 h
pH6.87.17.27.57.6
DO (mg/L) 0.30.33.13.5
MLSS (mg/L) 3400362042252650
VFA (mg/L)11207.51.23.3
Alkalinity (mg/L)275340330215180
HRT = 9 h
pH77.27.47.87.7
DO (mg/L) 0.30.223
MLSS (mg/L) 2670401536003560
VFA (mg/L)67383255
Alkalinity (mg/L)313365335265245
HRT = 6 h
pH6.87.27.37.67.7
DO (mg/L) 0.30.322.7
MLSS (mg/L) 3050232535504800
VFA (mg/L)3339331416
Alkalinity (mg/L)335350345220180
HRT = 3 h
pH78888
DO (mg/L) 0.20.21.82.5
MLSS (mg/L) 2820278020002500
VFA (mg/L)432520105
Alkalinity (mg/L)315290290230260
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Dohdoh, A.M.; Hendy, I.; Zelenakova, M.; Abdo, A. Domestic Wastewater Treatment: A Comparison between an Integrated Hybrid UASB-IFAS System and a Conventional UASB-AS System. Sustainability 2021, 13, 1853. https://0-doi-org.brum.beds.ac.uk/10.3390/su13041853

AMA Style

Dohdoh AM, Hendy I, Zelenakova M, Abdo A. Domestic Wastewater Treatment: A Comparison between an Integrated Hybrid UASB-IFAS System and a Conventional UASB-AS System. Sustainability. 2021; 13(4):1853. https://0-doi-org.brum.beds.ac.uk/10.3390/su13041853

Chicago/Turabian Style

Dohdoh, Ayman M., Ibrahim Hendy, Martina Zelenakova, and Ahmed Abdo. 2021. "Domestic Wastewater Treatment: A Comparison between an Integrated Hybrid UASB-IFAS System and a Conventional UASB-AS System" Sustainability 13, no. 4: 1853. https://0-doi-org.brum.beds.ac.uk/10.3390/su13041853

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop