Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 Cp810 Sound Processor

Experimental Audiology, ENT Department, University Hospital Zurich, Zurich, Switzerland
*
Author to whom correspondence should be addressed.
Submission received: 2 February 2015 / Revised: 20 July 2015 / Accepted: 21 August 2015 / Published: 7 October 2015

Abstract

The Nucleus® 5 System Sound Processor (CP810, Cochlear, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom Sound Processor (Cochlear) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of –8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.
Keywords: Cochlear implant; speech perception; noise; beamformer Cochlear implant; speech perception; noise; beamformer

Share and Cite

MDPI and ACS Style

Dillier, N.; Lai, W.K. Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 Cp810 Sound Processor. Audiol. Res. 2015, 5, 132. https://0-doi-org.brum.beds.ac.uk/10.4081/audiores.2015.132

AMA Style

Dillier N, Lai WK. Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 Cp810 Sound Processor. Audiology Research. 2015; 5(2):132. https://0-doi-org.brum.beds.ac.uk/10.4081/audiores.2015.132

Chicago/Turabian Style

Dillier, Norbert, and Wai Kong Lai. 2015. "Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 Cp810 Sound Processor" Audiology Research 5, no. 2: 132. https://0-doi-org.brum.beds.ac.uk/10.4081/audiores.2015.132

Article Metrics

Back to TopTop